Circular Dichroism.

Slides:



Advertisements
Similar presentations
The electromagnetic radiation The electromagnetic radiation is a complex wave form that can be considered to behave as two simple wave motions at right.
Advertisements

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
X-Ray Crystallography
SPECTROSCOPY.
Molecular Fluorescence Spectroscopy
Spectrophotometry Chapter 17, Harris
Characterization of Protein- & Biomolecule-based Biointerfaces
Light and Matter Tim Freegarde School of Physics & Astronomy University of Southampton Controlling light with matter.
c = km/sec I F = I 0 x (cosθ) 2.
Fiber-Optic Communications James N. Downing. Chapter 2 Principles of Optics.
Circular Dichroism Part I. Introduction.
Introduction to Spectrophotometry
Part 2.3: Dipole Moments and Optical Activity 1. Nonaxial (no rotation) - C 1, C s, C i Cyclic (rotational) -C n, C nv, C nh, S n Dihedral ( ⊥ C 2 ) -
Spectroscopy of Proteins. Proteins The final product of the genes, translated form genes (mutation in gene leads to a mutated protein) Made of a verity.
Electromagnetic spectrum Visible range: = nm Ultra-violet: = nm Low energyHigh energy.
Time out—states and transitions Spectroscopy—transitions between energy states of a molecule excited by absorption or emission of a photon h =  E = E.
Lecture 2a Optical Purity.
Bios 532 Circular Dichroism. Circular dichroism is a form of chiroptical spectroscopy. Chiroptical spectroscopy uses circularly polarized light, and commonly.
Introduction to Instrumental Analysis - Spectrophotometry
Review: Laws of Reflection and Refraction
ΔA(λ) = A(λ)LCPL - A(λ)RCPL
BCHM 313 – Physical Biochemistry
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Absorption Spectroscopy See you on the Dark Side of Biochemistry.
CIRCULAR DICHROISM SPECTROSCOPY structural analysis of nmol samples of macromolecules Prof. Eric Wickstrom.
Proteins: Secondary Structure Alpha Helix
Determination of Dynein Light Chain LC7 Stability and Folding using Circular Dichroism Rachel Rasberry HHMI Summer 2010 Working with Dr. Elisar Barbar.
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
1 Spectroscopic ANALYSIS Part 5 – Spectroscopic Analysis using UV-Visible Absorption Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett.
PHYS 252 / 2021 PHYS 252 & PHYS 202 Polarization Scattering Absorption.
EM waves are periodic changes of electric and magnetic fields in space and time. EM waves is transverse waves.
Applications of UV/VIS
States and transitions
Spectrophotometry.
Lecture 6c. Introduction Electromagnetic spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
LIGHT ABSORPTION SPECTROSCOPY colorimetric analysis of nmol samples of macromolecules Prof. Eric Wickstrom.
Asa Arjoon U6 Chemistry Presentation on Visible and Ultraviolet Spectroscopy Name : Form : Subject :
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
7.4 Properties of Chiral Molecules: Optical Activity.
SPECTROPHOTOMETRY. Spectrophotometry Determines concentration of a substance in solution –Measures light absorbed by solution at a specific wavelength.
Waves, Light & Quanta Tim Freegarde
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
UV SPECTROSCOPY Absorption spectra.
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Title: Lesson 5 B.7 Analysis of Proteins (SL and HL) Learning Objectives: – Describe methods to identify amino acid composition of an isolated protein.
Structural Analysis of Protein Structure
Proteomics 2015 蛋白質體學 Protein Analysis 陳威戎
CHIRALITY IN BIOMOLECULES SYMMETRY AND ASYMMETRY IN NATURE
An introduction to Spectrometric Methods. Spectroscopy Definition Spectroscopy is a general term for the science that deal with the interactions of various.
Hale COLLAGE (CU ASTR-7500) “Topics in Solar Observation Techniques” Lecture 3: Basic concepts in radiative transfer & polarization Spring 2016, Part 1.
Infrared (IR) Spectroscopy for Structural Analysis Ridwan Islam.
What spectroscopy for? By using different parts of the electromagnetic spectrum (different types of light) we can “see” separate details.
Proteomics 2013 蛋白質體學 Protein Analysis (II) 陳威戎
Circular Dichroism Part I. Introduction. Circular Dichroism Part I. Introduction.
Introduction to Spectrophotometry
Principles and practice of Spectrophotometer
Introduction to Spectrophotometry
Introduction to Spectrophotometry
Absorption Spectroscopy
Circular Dichroism Spectroscopy
Optical Spectroscopy: UV/Vis
UV SPECTROSCOPY Absorption spectra.
UV-VISIBLE SPECTROSCOPY Dr. R. P. Chavan Head, Department of Chemistry
-Primary and Secondary Structure-
CHM 5681 Circular Dichroism Source Detector Sample.
Absorption Spectroscopy
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Introduction During the last years the use of Fourier Transform Infrared spectroscopy (FTIR) to determine the structure of biological macromolecules.
Determination of Protein concentration by Ultraviolet spectroscopy Presented By Mr. Halavath Ramesh 16-MCH-001 Department of Chemistry Loyola College University.
Spectrophotometric Analysis
Presentation transcript:

Circular Dichroism

Circular Dichroism? 원편광 이색성 분광학 (Spectroscopy) CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed polarized light which arise due to structural asymmetry 분광학 (Spectroscopy) 물질과 전자기파(빛)의 상호작용을 연구, 물질에서 방출되거나 물질에 흡수되는 스펙트럼을 분석하여 물질을 분석

Circular Dichroism? 단백질 거울상(chiral) 이상질체인 D form과 L form으로 구성 D/ L form이 동일한 양으로 구성된 화합물을 Racemic mixture 편광된 빛이 asymmetric medium을 통과하면 optical rotation과 polarization loss 일어남 Ellipticity(loss)를 측정하여 ellipticity 크기와 경향을 diagram으로 나타낸 것이 Circular Dichroism

Light As an electromagnetic wave Direction Electrical component Magnetic component Direction Two component는 서로 수직 빛의 진행방향에도 서로 수직

Polarization(편광) 진행방향에 대해 수직으로 진동 = 횡파의 특성 횡파의 경우, 진동방향이 파동의 진행방향의 수직인 평면상에 놓여있게 되어 벡터의 성격을 갖게됨 편광 = 파동의 진동이 그 평면상의 특정 방향으로 놓이게 되는 것 편광방향 = 진동방향(물질에 더 큰 영향을 주는 전기장의 진동방향)

Polarization(편광) 빛은 짧은 길이의 무수히 많은 파동줄기(wave train)가 모여서 형성된 것이므로 하나하나의 편광상태가 어떻게 집합되어 있는가를 고려해야 하므로 통계적인 처리가 필요 빛은 물질과 반응하여 편광상태가 바뀔 수 있음

Polarization(편광) 선형편광 = 편광방향이 바뀌지 않음 전기장이 x 방향으로 진동하는 경우를 x 선형편광, y 방향 진동의 경우 y 선형편광 x, y 선형편광을 적절히 조합하면 임의의 방향의 선형편광이나, 원형편광도 만들어 낼 수 있다.

Polarization(편광) 전기장의 방향은 나선 형태로 계속 변함

Polarization

Dichroism The difference between the absorption of left and right handed circularly-polarized light is measured as a function of wavelength

Principle of CD Chiral molecules은 좌원편광, 우원편광 된 빛을 다르게 흡수 -> CD spectrum Chiral molecules은 optical active Optical activity = 편광 된 빛이 물질을 통과할 때 편광 면을 회전시키는 성질

(a) (b) (a) Linear polarized light can be viewed as a superposition of opposite circular polarized light of equal amplitude and phase (b) Different absorption of the left- and right hand polarized component leads to ellipticity (CD) and optical rotation (OR)

 is therefore the angle between the initial plane of polarization and the major axis of the ellipse of the resultant transmitted light A quantity  is defined such that tan  is the ratio of the major and minor axis of the ellipse of the transmitted light ’ approximates the ellipticity When expressed in degrees, ’ can be converted to a specific ellipticity [] or a molar ellipticity [] CD is usually plotted as []

스펙트럼 자외선 가시광선에 의해 분자나 원자가 에너지를 흡수하여 전이를 일으켜 발생 흡수된 빛의 파장은 낮은 에너지준위의 전자를 높은 에너지 준위로 이동시킬 수 있는 에너지가 있음

전자전이 결합분자 궤도 함수(bonding moleculer orbital):  ,  (에너지 준위가 낮음) 반 결합 분자궤도 함수(antibonding moleculer orbital):  *, * (에너지 준위가 높음) 비결합 전자 (nonbonding electron): n 전자 (유기 화합물 중 O, N, S 및 할로겐 원자) 전자의 전이는 전자가 결합성 궤도 함수(bonding orbital)에서 반결합성 궤도 함수(anti-bonding orbital)로 옮아가는 것을 의미함

Application Near UV CD (250 - 350 nm) Near-UV CD spectroscopy is dominated by Phe, Tyr, Trp and disulfides When an aromatic residue is held rigidly in space, its environment is asymmetric, and it will exhibit CD

Application Far UV CD (180 - 250 nm) The amide group is the most abundant CD chromophore in proteins In secondary structure conformations, the backbone and the amide bond chromophores are arranged in regular, organized, asymmetric patterns

Application n -> π* centered around 220 nm n -> π* involves non-bonding electrons of O of the carbonyl π -> π* centered around 190 nm π -> π* involves the π-electrons of the carbonyl The intensity and energy of these transitions depends on φ and ψ (i.e., secondary structure)

Application Far UV-CD of random coil: Far UV-CD of β-sheet: positive at 212 nm (π->π*) negative at 195 nm (n->π*) Far UV-CD of β-sheet: negative at 218 nm (π->π*) positive at 196 nm (n->π*) Far UV-CD of α-helix: Exciton coupling of the π->π* transitions leads to positive (π->π*)(perpendicular) at 192 nm and negative (π->π*)(parallel) at 209 nm negative at 222 nm is red shifted (n->π*) 엑시톤 exciton 반도체나 절연체 속에서 전도전자(傳導電子)와 양공(陽孔)의 쌍이 결합하여 한 중성입자를 형성한 것. 전류를 통하지 않는 비금속의 고체(절연체)에서는 전자가 모두 원자에 강하게 속박되어 고체 안을 이동할 수 없다. 이러한 고체에 빛을 쬐면 전자가 빛에너지를 흡수하여 원자에서 튀어나와 고체 안을 돌아다니게 된다. 흡수하는 에너지가 불충분할 때 전자는 원자에서 떨어질 수 없으므로 원자안의 에너지가 높은 상태로 들뜨게 된다. 그러나 들뜬 전자는 언제까지나 그 상태로 있을수는 없다. 전자는 주위의 원자에 속박된 전자와 서로 힘을 미치기 때문에 그들 전자의 하나에 에너지를 주고 자기는 본래의 상태로 돌아간다. 이렇게 하여 전자에 주어진 에너지는 원자에서 원자로 잇따라 전해진다. 전자는 이동하지 않고 들뜸〔勵起〕만이 마치 한개의 입자처럼 고체 안을 돌아다닌다. 이러한 들뜸을 엑시톤 또는 여기자(勵起子)라 한다. 엑시톤의 존재는 절연체의 빛 흡수로 나타난다. (즐거운 과학세상 사이언스올 http://www.scienceall.com)

Application Determination of secondary structure of proteins that cannot be crystallized Investigation of the effect of e.g. drug binding on protein secondary structure Studies of the effects of environment on protein structure Study of ligand-induced conformational changes

Application 광우병 진단 정상적인 cellular prion protein 의 경우, 단백질의 2차 구조가 대부분 alpha-helix로 이루어져 있다. 반면, 광우병에 걸린 scrapie prion protein은 beta structure 가 대부분의 2차 구조 구성 성분으로 변하게 된다. Alpha helical structure 에서 beta-structure 로의 변화를 CD를 통해 확인할 수 있고, 광우병의 발병유무를 측정가능하다.

Sample Preparation Additives, buffers and stabilizing compounds: Any compound which absorbs in the region of interest (250 - 190 nm) should be avoided. A buffer or detergent or other chemical should not be used unless it can be shown that the compound in question will not mask the protein signal.

Sample Preparation Protein solution: From the above follows that the protein solution should contain only those chemicals necessary to maintain protein stability, and at the lowest concentrations possible. Avoid any chemical that is unnecessary for protein stability/solubility. The protein itself should be as pure as possible, any additional protein or peptide will contribute to the CD signal.

Sample Preparation Contaminants: Unfolded protein, peptides, particulate matter (scattering particles), anything that adds significant noise (or artifical signal contributions) to the CD spectrum must be avoided. Filtering of the solutions (0.02 um syringe filters) may improve signal to noise ratio. Data collection: Initial experiments are useful to establish the best conditions for the "real" experiment. Cells of 0.5 mm path length offer a good starting point.

Sample Preparation Nitrogen purging: the function of purging the CD instrument with nitrogen is to remove oxygen from the lamp housing, monochromater, and the sample chamber. The reason for removing oxygen is that oxygen absorbs deep UV light, thus reducing the light available for the measurement.

Sample Preparation Typical Initial Concentrations: Protein Concentration: 0.5 mg/ml Cell Path Length: 0.5 mm Stabilizers (Metal ions, etc.): minimum Buffer Concentration : 5 mM or as low as possible while maintaining protein stability Need very little sample: 0.1mg

Advantage Simple and guick experiment No extensive preparation Measurements on solution phase Relatively low concentrations/amounts of sample Microsecond time resolution Any size of macromolecule

Disadvantage Difficult to quantitate similarity or differences Certain buffer components absorb strongly in Far-UV & can cause interference

Conclusion Near UV CD (250 - 350 nm) 편광된 빛이 asymmetric medium을 통과하면 optical rotation과 polarization loss 일어남 Ellipticity(loss)를 측정하여 ellipticity 크기와 경향을 diagram으로 나타낸 것이 Circular Dichroism Near UV CD (250 - 350 nm) Near-UV CD spectroscopy is dominated by Phe, Tyr, Trp and disulfides

Conclusion Far UV CD (180 - 250 nm) In secondary structure conformations, the backbone and the amide bond chromophores are arranged in regular, organized, asymmetric patterns Random coil, β-sheet, α-helix