Approved for Public Release

Slides:



Advertisements
Similar presentations
Alternator Protection for Emergency Standby Engine Generators
Advertisements

New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
BIOPOTENTIAL AMPLIFIERS
Lesson 38 Shipboard Power
Lecture 19 Dimitar Stefanov Powered Wheelchairs 1940s – first powered wheelchairs, standard manual wheelchairs adapted with automobile starter motors.
DOD Microgrids The Missing Link: Microgrid Applications Michael Dempsey P.E. Burns & McDonnell June 12, 2013 © 2013 Burns & McDonnell. All Rights Reserved.
Power System Fundamentals
EUT 1040 Lecture 10: Programmable Logic Controllers.
LHC UPS Systems and Configurations: Changes during the LS1 V. Chareyre / EN-EL LHC Beam Operation Committee 11 February 2014 EDMS No /02/2014.
Aidan Tuohy Technical Leader/Project Manager, EPRI ERCOT Emerging Technology Working Group (ETWG) 09/24/2014 Transmission System Considerations for Integrating.
Shipboard Electrical Distribution …“Shifting the Electric Plant to a Normal Full Power Lineup.”
Chapter 1 Aircraft Electrical System. Chapter 1 Aircraft Electrical system Electrical component Storage Battery DC & AC Generator Control and Protection.
Data Processing Equipment
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
PARMENANT MAGNET SYNCHRONOUS GENERATOR BY JA’FAR R.A. AZIM Assem M.A. Al ighrair.
Three-Phase ac Voltage Generation
Chapter 7 SYSTEM PROTECTION
13-15 March 2002 Power Systems Conference 2002 Impact of Distributed Generation 1 Harmonic and Distributed Generation Interaction Issues in the U.S. Navy.
Confidential & Proprietary. What happens when Wind /Solar do not meet requirements? What next?
Discussion #27 – MotorsECEN 3011 Faith and Works James 2: Even so faith, if it hath not work, is dead, being alone. 18 Yea, a man may say, Thou.
THE TRES AMIGAS SUPERSTATION Southwest Renewable Energy Conference Santa Fe, NMSeptember 16 th 2010 UNITING THE NATION’S ELECTRIC POWER GRID.
Shipboard Electrical Distribution References Required Introduction to Naval Engineering – Ch 17.
Inductive Power System for Autonomous Underwater Vehicles
Applying the Distribution System in Grid Restoration/NERC CIP-014 Risk Assessment Srijib Mukherjee, Ph.D., P.E. UC Synergetic.
 Interconnecting DER With Electric Power Systems POWER SYSTEM 2002 CONFERENCE -- IMPACT OF DISTRIBUTED GENERATION Image.
Energy Storage and Renewable Integration. 2 Dynapower Dynapower Corporation Dynapower Corporation is the world’s leading Independent manufacturer of standard.
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
IMPROUVEMENT OF COMPUTER NETWORKS SECURITY BY USING FAULT TOLERANT CLUSTERS Prof. S ERB AUREL Ph. D. Prof. PATRICIU VICTOR-VALERIU Ph. D. Military Technical.
Lecture 11 Electrical Networks 1. Lecture 12 A Question Can you point out different types of electrical or electronic equipments, devices in this classroom?
Overview of Distributed Generation Applications June 16, 2003 Harrisburg, PA Joel Bluestein Energy and Environmental Analysis, Inc.
1 TRANSMISSION SYSTEM OVERVIEW NETWORK OPERATING COMMITTEE April 17, 2007 New Mexico Transmission System Overview.
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
Introduction to Power Supplies
1 Distributed Generation and Power Quality-Continued.
Steady State Analysis Of A Microgrid Connected To A Power System
Ship Design Exercise: 10,000 ton, 100 MW, 20kVDC Surface Combatant ESRDC.
Brandon Halleran.  The power supply for your personal computer gives your machine all the different voltages it needs to operate properly. It is able.
DESIGN OF MONO-AXIS SOLAR TRACKING SYSTEM USING MICROCONTROLLER BASED STEPPER MOTOR KAMAL J K KOUSHIK VENKATRAMAN N PREM M PRASANTH K Guidance: Mrs.Kavitha.
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
MIT Contribution to ESRDC Effort Chryssostomidis Hover Karniadakis Kirtley Leeb Triantafyllou Chalfant Marden Prempraneerach
UH-60 IPC/MOI CW2 JAMES THOMAS.
WELCOME.
MVDC Collaboration MVDC Issues and Viability of Red Demo in Philadelphia.
1 40 MW 20 MW 15 MW 11 MW5 MW HFAC Baseline Architecture: modeling status R. Hebner A. Ouroua Center for Electromechanics The University of Texas at Austin.
1 PEBB-based Power Electronic Systems to Support MVDC Studies Herbert L. Ginn III, Mississippi State University.
1 Meeting of Red Team – Purple Team Ship Design Process and Model Development Arlington VA August 20, 2010.
MVDC & MVAC Baseline Architecture Models in RTDS and ESRDC’s VV&A Process Michael “Mischa” Steurer Grant No. N Discussion at RedTeam Meeting.
Purpose Discuss and identify areas of collaboration on the NGIPS MVDC system architecture Understanding areas of risk in the MVDC architecture Perform.
Automatic Transfer Switches
v1/2011 Strikesorb Protection Solutions
Electrification of the Future US Navy Warships
PCIM Europe 2016 Power Conversion and Intelligent Motion
Modular Power Conversion Cabinet for Future Warships
ESRDC Overview for Load Management
Introduction to Global AC Power
IG BASED WINDFARMS USING STATCOM
Computational tools for early-stage ship design: UT Activities
IMPEDENCE - SOURCE INVERTER FOR MOTOR DRIVES
Shipboard Electrical Distribution
Ship Electric Power Systems: Activities at MIT
Wen Cai Supervisor: Dr. Babak Fahimi December 04, 2015
THREE-PHASE GROUND-FAULT BASICS
Anna Brinck, M.S. Student Robert Cuzner, Assistant Professor
Willy Sedano, Graduate Student - University of Wisconsin-Milwaukee
Electrical Distribution System Basics
CDR Stephen Markle USN (ret)
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Presentation transcript:

Approved for Public Release The Road to MVDC ASNE ISS 2015 Philadelphia, PA May 20-21, 2015 Dr. Norbert Doerry Dr. John Amy 4/15/2015 Approved for Public Release

Approved for Public Release 4/20/2017 Setting the Scene “In FY2030, the DON plans to start building an affordable follow-on, multi-mission, mid-sized future surface combatant to replace the Flight IIA DDG 51s that will begin reaching their ESLs [Estimated Service Life] in FY2040.” Report to Congress on the Annual Long-Range Plan for Construction of Naval Vessels for FY2015 Big differences from DDG 51: High-energy weapons and sensors Flexibility for affordable capability updates According to Long Range Shipbuilding Plan, DDG 51 replacement will be awarded in 2030 DDG 51 has been an outstandingly successful design, but two factors will drive it’s replacement: First is that sensors and weapons are coming online that overtax the current electrical plant. Second is that tight budgets mean that the Navy will need long service lives from new designs, and they must be affordable to adapt to evolving threats and missions. Photo by CAPT Robert Lang, USN (Ret), from site http://www.public.navy.mil/surfor/swmag/Pages/2014-SNA-Photo-Contest-Winners.aspx 4/15/2015 Approved for Public Release

Increasing Electrical Power Demands 4/20/2017 Increasing Electrical Power Demands 2022+ 2022 20-30 MW 20 MW 0.4 MW 0.7 MW 2020 2018 Free Electron Laser Available Power (Electric Power Installed) Electro- Magnetic Rail Gun Solid State Laser We’re entering a new age of high-powered weapons and sensors. This chart show how mission system electrical loads have grown historically, and what we project for the future. USS Trenton, 1877 Active Denial System 1877 Today Sensor and Weapon System Power demands will soon rival Propulsion Power demands 4/15/2015 Approved for Public Release

High Energy Mission Systems Integration Challenge Radar Understanding how the combined load stresses the power system is essential to prevent system failure or failure at one of the loads SSL Combined Load Challenge Power Source ? SEWIP In addition to high-energy weapons, radars and electronic countermeasures are growing far more powerful with each generation in order to pace rapidly evolving threats Combination of large “spikey” loads can overwhelm today’s electrical systems Power quality Mechanical components can’t keep up System damage possible Challenge is to engineer ship power systems to seamlessly handle these large, unpredictable loads Ships cannot support High Power Systems without modifications to the ships Electric Power System and other ship systems 4/15/2015 Approved for Public Release

Future Operational Mode 4/20/2017 Future Operational Mode Peaky Loads Multi-Device Energy Storage Sized for Peak and Continuous Ride Through Adv. Energy Storage Mil Std Power Quality + Taming the large power demand spikes that the new high-energy mission systems will bring will require new system architectures Energy storage Distribution systems Efficient power generation Controls Continuous Generator loading Power Generation Free to Operate at Most Fuel Efficient, Reliable Level Generator Load Profile Optimize storage buffering prime movers to enable continuous DEW operations with minimal effect on engine mechanicals and power quality… 4/15/2015 Approved for Public Release

Why Medium Voltage DC? Decouple prime mover speed from power quality Minimize energy storage Power conversion can operate at high frequency – Improve power density Potentially less aggregate power electronics Share rectification stages Cable ampacity does not depend on power factor or skin effect Power Electronics can control fault currents Use disconnects instead of circuit breakers Acoustic Signature improvements Easier and faster paralleling of generators May reduce energy storage requirements Ability to use high speed power turbines on gas turbines Affordably meet electrical power demands of future destroyer An AC Integrated Power System would likely require future destroyer to displace greater than 10,000 mt 4/15/2015 Approved for Public Release

Candidate MVDC Reference Architecture Bus Node AC LC PCM SP PCM 1A PCM 1A PCM 1A AC LC AC LC PMM IPNC IPNC IPNC EMRG PGM PGM PGM PGM IPNC IPNC IPNC PMM AC LC AC LC PCM 1A PCM 1A AC LC PCM 1A PCM SP 4/15/2015 Approved for Public Release

Bus Nodes Segment MVDC Bus Isolate loads Isolate sources Possibly integrated with PCM 1A and PGM Segment MVDC Bus Disconnects Isolate loads Isolate sources Breaker Disconnect if Breaker functionality in source Establishes Ground Reference for MVDC Bus If functionality not provided in source Ground Reference Device Next Zone Next Zone Multi-Function Monitor (MFM) If needed for fault management Disconnect if Functionality integrated with PCM 1A and PGM PGM PCM 1A MVDC Load 4/15/2015 Approved for Public Release

Approved for Public Release PCM-1A Bus Node PCM-1A I-module I-module Internal DC Bus ESM O-module IPNC O-module loads ESM = Energy Storage Module IPNC = Integrated Power Node Center I-module = Input Module O-module = Output Module O-module Protects the MVDC bus from in-zone faults Provides hold up power while clearing faults on the MVDC Bus If desired, provides hold up power while standby generator starts If desired, contributes to energy storage for pulse power loads Provides conditioned power to loads Provides power to loads up to several MW (Lasers, Radars, Electronic Warfare) Provides power to “down-stream” power conversion (IPNC) Near term applications could use I-modules with AC inputs in “Energy Magazine” configuration 4/15/2015 Approved for Public Release

Approved for Public Release Load Centers Next Zone LC PCM 1A Traditional 450 VAC switchgear May need modification for limited fault current Normally powered by PCM 1A. Breaker to next zone Load Center (LC) normally open Upon loss of PCM 1A Machinery Control System switch source to the next zone’s LC May require load shedding Provide alternate source to IPNC for uninterruptible loads Casualty Power Riser Enables interconnection of LC to jumper over damaged zones. Possibly use 450 VAC shore power connectors Non Vital Loads Alt Source for IPNC Casualty Power Riser Vital Loads 4/15/2015 Approved for Public Release U.S. Navy: 120110-N-DR144-521

Compartment Level Survivability May employ more than 1 AC Load Center (AC LC) in a zone Physically separated to minimize probability that multiple LC are lost at same time due to battle damage Careful routing of feeder cables required to maximize survivability Provide multiple methods of routing power from in-zone PCM 1A and adjacent zone PCM 1A Use Controllable Bus Transfer (CBT) for Emergency Loads not physically near an AC LC (or if powered by an IPNC, not physically near the IPNC) Normally only power loads in a zone from the in-zone PCM 1A. 440 VAC Emergency Load AC LC PCM 1A CBT AC LC IPNC CBT AC LC IPNC PCM 1A 440 VAC Emergency Load AC LC Normally open 4/15/2015 Approved for Public Release

Integrated Power Node Center (IPNC) Update MIL-PRF-32272 Include 1000 VDC input modules Include provision for energy storage for ~1 second allow 450 VAC LCs in zone and in adjacent zone to reconfigure. Zone may have multiple IPNCs Supply Un-interruptible loads Supply loads with special power needs. 400 Hz. VSD motor loads Perhaps Low voltage DC Loads 4/15/2015 Approved for Public Release

Power Generation Modules IEEE 1826 “Overlay Zone” Split Windings Reduced Impact on prime mover due to fault on one MVDC bus Simplifies “odd number of generators” dilemma May enable reducing ampacity of MVDC bus Consider Fuel Cells in the future To Bus Node Rectifier Normally open Gen PM Rectifier Generator has 2 independent sets of windings To Bus Node PGM may include circuit breaker functionality and ground reference device functionality 4/15/2015 Approved for Public Release

Propulsion Motor Modules Typically two motors for reliability May share housing Normally powered by both MVDC busses Requires control interface for load management Consider contra-rotating propellers for fuel efficiency and minimizing installed electrical power generation capacity To Bus Node Drive Normally open Motor Motor Drive To Bus Node 4/15/2015 Approved for Public Release

Electromagnetic Railgun To Bus Node PCM-1B similar to PCM-1A 10’s of MW vice 1’s of MW Powers Mount equipment in addition to Pulse Forming Networks (PFN) Normally powered by both MVDC busses Requires control interface for load management Launcher PCM 1B PFN Normally open Mount PCM 1B PFN To Bus Node 4/15/2015 Approved for Public Release

MVDC Voltage Standards Proposed MVDC nominal voltages based on IEEE 1709 6000 VDC 12000 VDC 18000 VDC Current levels and Power Electronic Devices constrain voltage selection 4000 amps is practical limit for mechanical switches Power electronic device voltages increasing with time (SiC will lead to great increase) For now, 12000 VDC appears a good target … 4000 amps per bus enables 96 MW on 2 busses Power Quality requirements TBD 4/15/2015 Approved for Public Release

Issues needing resolution Power Management Energy Storage / Energy Management System Stability Bus Regulation Prime Mover Regulation Fault Detection, Localization and Isolation System Grounding Magnetic Signature Affordability Need resolution by 2025 to support 2030 Lead Ship Contract Award 4/15/2015 Approved for Public Release

Approved for Public Release Summary Power and energy density needs of a future destroyer with large pulse loads suggest a preference for MVDC An MVDC system must be affordable A number of technical issues need to be resolved in the next decade 4/15/2015 Approved for Public Release