ANALYTICAL METHODS FOR AIRBORNE HEXAVALENT CHROMIUM Kevin Ashley, Ph.D. U.S. Department of Health and Human Services Centers for Disease Control and Prevention.

Slides:



Advertisements
Similar presentations
Oxidation-Reduction: A Reaction
Advertisements

CE 541 Complex Formation.
Speciation of Chromium. Research Project: Assessing the Impact of Chromium in the Environment Funding provided by Florida Department of Environmental.
A galvanic cell is made from two half cells. In the first, a platinum electrode is immersed in a solution at pH = 2.00 that is M in both MnO 4 -
Research on the Speciation of Chromium as Relates to CCA.
Review of Analytical Methods for Nutrient Parameters focusing on Nitrates An Overview By Michael Jackman Chemistry Expert.
Chromates (Hexavalent Chromium) ASSE ASSE Region III Professional Development Conference Austin, Texas August 7, 2006 Frank M Parker, III CIH, CSP, PE,
THE CAROLINA DEPOT 5/3/2015Kathryn Stepp Ver.1 Vacuum Assisted Tools and Glove Bags Reduce Chromium VI Exposure During Aircraft Corrosion Control Work.
Review of Chromium Speciation Research. Research Project: Assessing the Impact of Chromium in the Environment Assessing the Impact of Chromium in the.
Aqueous Ionic Solutions and Equilibrium Chapter 19.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
14 th Arab International Cement Conference November - Cairo Determination and Reduction of Cr(VI) in cement Davide Padovani & Matteo Magistri.
As and Cr Speciation of New & Weathered CCA-Treated Wood.
Ramesh Chawla and Jacob Mlusu Department of Chemical Engineering
Development of an Automated, Pyridine Free Method for Aerosol Cyanide Compounds and Hydrogen Cyanide. An Alternative to NIOSH LeRoy Dobson, Chemist.
Hazards of Hexavalent Chromium in the Workplace. Disclaimer This material was produced under grant number SH F-54 from the Occupational Safety.
Separation and Identification of the Group II Hydroxides in an Unknown
The K sp of chromium (III) iodate in water is 5.0 x Estimate the molar solubility of the compound. Cr(IO 3 ) 3 (s)  Cr 3+ (aq) + 3 IO 3 - (aq)
Reduction and oxidation
REDOX CLASSIFICATION OF NATURAL WATERS
Remediation of Mixed Chromium and TCE Releases
EXTRACTION OF BROMINE FROM SEA WATER
Consensus Standards, Method Uncertainty and Quality Assurance in Analytical Chemistry Curricula Kevin Ashley, Ph.D. U.S. Department of Health and Human.
Determination of Metals
Occupational Exposure to Metalworking Fluids Occupational Exposure to Metalworking Fluids Presented at the Occupational Hygiene Association of Ontario.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Size-segregated analysis of PM10 at a tandem urban – rural site combination J. K. Gietl 1*, T. Tritscher 1,2, and O. Klemm 1 1 University of Münster, Institute.
Coulometric Methods A.) Introduction:
Parts per Million Concentration. Parts per Million (ppm) is the ratio of the number of grams of solute for every one million grams of solution. parts.
Chemical Treatment Precipitation and Reduction/Oxidation (Section 9-4)
ANALYTICAL CHEMISTRY CHEM201/212/213. ANALYTICAL CHEMISTRY (16 ANALYTICAL CHEMISTRY (16 Lectures + 6 Tutorials) Statistical tests and error analysis:
DEVELOPMENT OF A RP-HPLC METHOD FOR THE DETERMINATION OF METFORMIN IN HUMAN PLASMA.
INTRODUCTION AND OBJECTIVES COMPARATIVE DETERMINATION OF ZINC IN PHARMACEUTICAL PRODUCTS CORCIOVĂ ANDREIA, CIOBANU CONSTANTIN “Grigore T. Popa” University.
Starter 2. Complete the electronic arrangement of the Co 2 + ion. (1 mark) [Ar] 3. Explain why complex ions with partially filled d sub-levels are usually.
Chromium Team Ken Andrzejewski Ye Eun Oh Jasmine Podell
REDOX TITRATIONS. REDOX Titrations A redox titration is used to determine the concentration of an oxidizing or reducing agent. The reaction needs to have.
1 Analytical Methods for Perchlorate: Current Technology and Possibilities for the Future David J. Munch Daniel P. Hautman Office of Ground Water and Drinking.
Applications of Redox Electrochemistry. Review Oxidation reduction reactions involve a transfer of electrons. OIL-RIG Oxidation Involves Loss Reduction.
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
1 Gravimetric Analysis. 2 Gravimetric analysis is the quantitative determination of analyte concentration through a process of precipitation of the analyte,
Chapter 16 Lesson 2 Solubility and Complex Ion Equilibria.
CHEM 100 Chemistry and Society Winter Quarter 2008 SCCC Lecture 38 In all the hurry to revise don’t forget to do a good job on lab reports….
Sampling and Analysis of Isocyanates Used in Paints Robert P. Streicher National Institute for Occupational Safety and Health Publications of the U.S.
Analyzing SPARTAN filters with an Aerosol Mass Spectrometer Rachel O’Brien, Kelsey Ridley, Jesse Kroll Department of Civil and Environmental Engineering,
Complex Ion Equilibria and Solubility A complex ion can increase the solubility of a salt. Ag + (aq) + 2 NH 3 (aq) Ag(NH 3 ) 2 + (aq) K f = [Ag(NH.
Environmental Bio-Systems, Inc.
MIRAN Gas Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting personal.
Health Hazards!!! Introduction:
Department of Defense Voluntary Protection Programs Center of Excellence Development, Validation, Implementation and Enhancement for a Voluntary Protection.
AIR SAMPLING APRIL NEWSWORTHY TOPICS IN AIR SAMPLING 1. Hydrogen Peroxide-New OSHA Method 2. Total Particulates-New NIOSH Method 3. Elements (Metals)-New.
Professor: 莊順興 Presenter: 李謙詳 2016/01/04. * Unlike physical separation processes that merely concentrate or change the phase of hazardous wastes. * chemical.
Motivation Chemiluminescence Method Heteropoly Blue Results Due to the harmful health effects of respirable crystaline silica, the National Institute of.
William L Masterton Cecile N. Hurley Edward J. Neth cengage.com/chemistry/masterton Edward J. Neth University of Connecticut Chapter 4 Reactions in Aqueous.
AIR SAMPLING HEADLINES IN HYGIENE APRIL 2016.
M. M. Khalil, S. M. Mostafa, and A. A. Masoud  Scholars Report 
Optimizing the Sensitivity of Particulate Silica Quantification by Molybdenum Blue Absorbance Spectrometry John Tum*, Ethan Fuhrman*†, Emily Wagner*†,
PH and Buffers.
Electrochemistry Review
Stack Sampling.
Introduction 3. Instrumentation 2. Objectives 4. Results
Is it just another employee complaint?
Technical Sales & Support Chemist
Hydride Generation–AFS for Arsenic Speciation in Food
Chapter 12 EDTA Titrations
Increasing TKN Sample Determinations Through Automation
The Solubility Product Constant, Ksp
Professional Organizations
Good Practice Sheet for Uses of Chromium Trioxide
Gravimetric Analysis.
Presentation transcript:

ANALYTICAL METHODS FOR AIRBORNE HEXAVALENT CHROMIUM Kevin Ashley, Ph.D. U.S. Department of Health and Human Services Centers for Disease Control and Prevention National Institute for Occupational Safety and Health Cincinnati, OH 45226

INTRODUCTION New Analytical Methods for Cr(VI) in Workplace Air: –NIOSH 7605 (draft) Revised lab method –NIOSH 7703 (draft) New field method –OSHA ID-215 New lab method

INTRODUCTION (continued) To be presented: –Overview of the three analytical methods for Cr(VI) –Need for updating: increased sensitivity –Advantages and limitations

INTRODUCTION (continued) –Comparison of the performance of the 3 methods OSHA vs. NIOSH lab vs. NIOSH field –Field studies – On-site method (NIOSH 7703 [draft]) –Examples from aircraft painting/ maintenance

LABORATORY METHOD FOR Cr(VI) 1.Sample onto PVC filters] 2.Hot plate extraction using pH ~8 buffer 3.Ion chromatography to isolate Cr(VI) 4.Post-column derivatization with 1-5 Diphenylcarbazide 5.Visible detection of Cr-DPC complex

ISSUES: Reduction of Cr(VI) to Cr(III) during sampling/extraction: –Use of PVC filter (rather than MCE) –Acid mist & iron in aerosol problematic –Base treatment of filter to stabilize Cr(VI) –pH ~8 buffer stabilizes Cr species in solution

ISSUES: Oxidation of Cr(III) to Cr(VI) during extraction: –Minimize by using slightly basic buffer –OSHA uses precipitation agent to cause Cr(III) 9 Cr(III)/Cr(VI) redox equilibrium during extraction: –Ammonium sulfate buffer prevents Cr(III) : Cr(VI)

FIELD METHOD FOR Cr(VI) 1.Sample onto PVC;[ MCE or PTFE ok if analyzed promptly.] 2.Ultrasonic extraction 3.SAE-SPE to isolate Cr(VI) 4.Elute, acidify, and react Cr(VI) with DPC 5.Measure Cr-DPC complex with portable UV/Vis

Cr(VI) REACTION WITH DPC: NH-NH-C 6 H 6 / O=C+ Cr(VI) \ NH-NH-C 6 H 6 Diphenylcarbazide 9 9 N - N - C 6 H 6 // * C-O-Cr (H 2 O) 4 \ ! N = N - C 6 H 6 Diphenylcarbazone - Cr(III) complex DPC Cross-reactants: Mo, Mg, Hg, V

Cr(VI) ANALYTICAL METHODS COMPARISON ______________________________________________ Parameter Lab Methods Field Method Extraction:NaOH/Na 2 CO 3 *(NH 4 ) 2 SO 4 /NH 4 OH HotplateUltrasonic bath Cr(VI) sep’n.:Ion chromatographySPE Eluent:(NH 4 ) 2 SO 4 /NH 4 OH(NH 4 ) 2 SO 4 /NH 4 OH Detection:Cr-DPC (540 nm)Cr-DPC (540 nm) LOD/LOQ:0.02/0.07 F g/m /0.30 F g/m 3 ___________________________________________ *NIOSH: degas; OSHA: ppt’n. for Cr(III) º Cr(VI)

METHOD PERFORMANCE– IRMM CRM 545 ( Cr[VI] in welding fume on filters) _____________________________________________ Analytical Method n % Recovery (+/-RSD) NIOSH 7605(lab) OSHA ID-215 (lab) NIOSH 7703 (field) _____________________________________________

Cr(VI) METHOD CRITERIA Analytical Figures of Merit: –LODs <10x planned OSHA PEL % –Lab & field methods meet NIOSH accuracy criteria % Costs: –Lab method estd. $50 per sample (by contract lab) –Field method estd. < $15 per sample (excl. labor) –Lab equipment >> field equipment –Field method throughput < lab method

Cr(VI) METHOD CRITERIA (Lab method vs. field method, cont’d.) Advantages: –Lab method high throughput, automated –Lab method alleviates need for extra field person –Field method results in ~ hrs. –Field method alleviates sample instability problems

Cr(VI) METHOD CRITERIA (Lab method vs. field method, cont’d.) Drawbacks: –Lab results not timely (note construction appls.) –High maintenance on equipment for lab method –Field method more hands-on –More work for IH or need for extra body

SUMMARY Successful methods for speciation of Cr. –Lab and field methods available –Comparison between methods good –Field method field tested –To be published in NMAM

SUMMARY (cont’d.) Sampling remains problematic. –Reduction of Cr(VI) during sampling of certain aerosols –New strategies & further study needed –ISO lab draft standard based on NIOSH draft lab method.

ACKNOWLEDGMENTS CDC/NIOSH U.S. Air Force Jin Wang Ellen England Jim Boiano David Marlow Marjorie Wallace Karl Sieber Jensen Groff

y = x r 2 = Cr VI Concentration (  g /m 3 ) OSHA ID-215 Cr VI Concentration (  g/m 3 ) NIOSH 7605 Facility 1 Facility 2 The slope is not significantly different from unity Comparison of Hexavalent Chromium Concentrations by Sample Cluster: OSHA ID-215 and NIOSH 7605

y = x r 2 = Cr VI Concentration (  g/m 3 ) NIOSH 7605 Cr VI Concentration (  g/m 3 ) NIOSH 7703 Facility 1 Facility 2 The slope is not significantly different from unity Comparison of Hexavalent Chromium Concentrations by Sample Cluster: NIOSH 7605 and 7703