Accuracy of the FreeStyle Navigator ™ Continuous Glucose Monitor Diabetes Research in Children Network Larry Fox, 1 Roy Beck, 2 Stuart Weinzimer, 3 Katrina.

Slides:



Advertisements
Similar presentations
Independent Project HCAI 5221 Evaluation of Point of Care Bedside Glucose Monitors for Use in a Specialty & Transplant Hospital Mary A. Weidner, BS, MT(ASCP)
Advertisements

Down Alert Function of the GlucoWatch® G2 TM Biographer (GW2B) During Insulin- induced Hypoglycemia in Children Eva Tsalikian 1, Craig Kollman 2, Rosanna.
INTRODUCTION TO CONTINUOUS GLUCOSE MONITORS
Diabetes Self-Management Profile- Revised for Conventional and Flexible Insulin Regimens Wysocki, T. 1, Xing, D. 2, Fiallo-Scharer, R. 3, Doyle, E. 4,
ABSTRACT CONCLUSIONS BACKGROUND Heart Rate Recovery: An Indicator of Fitness Among Middle School Children Daniel Simhaee, Roopa Gurm, Susan Aaronson, Jean.
Continuous Glucose Monitoring. Diabetes Management Evolution Insulin Delivery Glucose Monitoring 2000 First CGM system 2006 Paradigm REAL- Time, combining.
1 GLUCOWATCH ® G2™ BIOGRAPHER H. PETER CHASE, MD I)INTRODUCTION II)ACCURACY DATA III) HOME PILOT TRIAL IV) DIRECNET STUDY GROUP V) SUMMARY.
Continuous Glucose Monitoring
Ambulatory Blood Pressure Profiles in Adolescents with Type 1 Diabetes Andrew J. Ellis 1,2, B.A.; David M. Maahs 2, M.D. Ph.D.; Franziska K. Bishop 2,
Diabetes Control in Youth: The American Experience Georgeanna J. Klingensmith, MD Keystone Colorado July 2008.
DAVID C KLONOFF, MD Medical Director Dorothy L. and James E. Frank Diabetes Research Institute of Mills-Peninsula Health Services Clinical Professor of.
1 INTRODUCTION TO CONTINUOUS GLUCOSE MONITORS H. Peter Chase, MD Vicky Gage, RN, CDE Laurel Messer, RN, CDE Susie Owen, RN, CDE Sally Sullivan, RN, CDE.
1 Progress Towards an Artificial Pancreas for T1D WILLIAM TAMBORLANE, MD Chief of Pediatric Endocrinology, Yale University, Deputy Director, Yale Center.
Suhyla Alam (Eastern Virginia Medical School), Amy West, Maura Downey, Jane EB Reusch, Kristen Nadeau University of Colorado Denver and Children’s Hospital.
Diabetes Research in Children Network (DirecNet) Outpatient Pilot Study to Evaluate the GlucoWatch® G2 TM Biographer in the Management of Type 1 Diabetes.
Accuracy of the A1cNow ® in Children with T1D. Diabetes Research in Children Network Larry Fox, 1 Dongyuan Xing, 2 Katrina Ruedy, 2 Roy Beck, 2 Craig Kollman,
Limitations of Statistical Measures of Error in Assessing the Accuracy of Glucose Sensors Craig Kollman1, Darrell Wilson2, Tim Wysocki3, Rosanna Fiallo-Scharer4,
Practical Aspects of Continuous Glucose Monitoring 2008 Rosanna Fiallo-Scharer, MD Laurel Messer, RN, BSN, CDE Barbara Davis Center for Childhood Diabetes.
ABSTRACT CONCLUSION RESULTSBACKGROUND Decreased High Density Lipoprotein Cholesterol in a Cohort of 6th-grade Children: Association with Cardiovascular.
Diabetes Research in Children Network (DirecNet) Outpatient Pilot Study to Evaluate the Feasibility of Computer-Based Data Acquisition and Transmission.
A 5-center CRC-based Study of the Accuracy of the GlucoWatch® G2 TM Biographer in Children and Adolescents with Type 1 Diabetes Darrell Wilson 1, Bruce.
Diabetes Technology Update
Mealtime Glycemic Excursions in Pediatric Subjects with Type 1 Diabetes: Results of the Diabetes Research in Children (DirecNet) Accuracy Study Study Group.
Chronic Diabetes Case F Gestational Diabetes Mellitus (GDM) Clinical Pathology B Hoa Nguyen Tuan Anh Tran Thi Thuy Duong Trang.
Closed-Loop Insulin Delivery in Children
L.M. Fisk, A.J. Le Compte, G.M. Shaw, S. Penning, T. Desaive, J.G. Chase Pilot Trial of STAR in Medical ICU INTRODUCTION Background: Accurate glycemic.
Abstract Background: As part of a study to evaluate the accuracy of the GlucoWatch ® G2 TM Biographer and the Continuous Glucose Monitoring System (CGMS.
Diabetes Control and Complications Trial (DCCT) Results indicate that most youth with T1DM should be treated intensively in order to reduce the risk of.
Background: DirecNet Diabetes Research in Children Network NIH funded collaborative study group 5 clinical centers, central laboratory, coordinating center,
Making the Most of Continuous Glucose Monitoring Gary Scheiner MS, CDE Owner & Clinical Director Integrated Diabetes Services LLC Wynnewood, PA AADE 2014.
Diabetes Research in Children Network Pilot Study of the Navigator TM Continuous Glucose Monitoring System in Children with Type 1 Diabetes: Safety, Tolerability,
Journal Club 埼玉医科大学 総合医療センター 内分泌・糖尿病内科 Department of Endocrinology and Diabetes, Saitama Medical Center, Saitama Medical University 松田 昌文 Matsuda, Masafumi.
Event-Based Assessments of Sensor Accuracy during Exercise-Induced Reductions in Glucose in Children with Type 1 Diabetes Craig Kollman, 1 Darrell Wilson,
Impact of Exercise on Overnight Glycemic Control in Children with Type 1 Diabetes (T1DM) Eva Tsalikian 1 ; Roy Beck 2 ; Peter Chase 3 ; Tim Wysocki 4 ;
Corticosteroid dosing in the treatment of acute exacerbations of COPD Kurt A. Wargo, Pharm.D., BCPS, Takova D. Wallace, Pharm.D. Candidate 2014, Ryan E.
Internet-based pilot study comparing low fat with high fat evening snacks in children and adolescents with Type 1 Diabetes using continuous glucose monitoring.
Use of The FreeStyle Navigator TM Continuous Glucose Monitoring System in Children on Glargine- based Multiple Daily Injection Therapy Stuart Weinzimer.
Use of the FreeStyle Navigator ™ Continuous Glucose Monitoring System in Children with Type 1 Diabetes Diabetes Research in Children Network L. A. Fox,
ABSTRACT Diabetes is a public health issue of growing magnitude. It currently ranks among the top ten leading causes of death in the United States. To.
Lack of Effectiveness of the GlucoWatch Biographer (GW2B) in Altering Glycemic Control in Children with Type 1 Diabetes H. Peter Chase 1, Roy Beck 2, William.
A Comparison of the Original vs. Modified Continuous Glucose Monitoring System (CGMS™) Sensor During Hypoglycemia in the Diabetes Research in Children.
Utility of CGMS as a Measure of Glycemic Control in Children with Type 1 Diabetes (T1DM) Rosanna Fiallo-Scharer, MD for.
Reliability of two indices of the biologic variability in glycosylation among children and adolescents with T1DM Darrell M Wilson 1, Rosanna Fiallo-Scharer.
Effectiveness of Early Intensive Therapy On β-Cell Preservation in Type 1 Diabetes Featured Article: Bruce Buckingham, M.D., Roy W. Beck, M.D., P.H.D.,
1 Part 2 Routinely Identifying Postprandial Hyperglycemia - Challenges & Tools An Educational Service from G LYCO M ARK G LYCO M ARK is a registered trademark.
Evaluation of Factors Affecting CGMS Calibration Bruce Buckingham, 1 Craig Kollman, 2 Roy W Beck, 2 Andrea Kalajian, 2 Rosanna Fiallo-Scharer, 3 Michael.
Accuracy Study of the Medtronic Minimed Continuous Glucose Monitoring System (CGMS) and GlucoWatch® G2TM Biographer (GW2B) in Children with Type 1 Diabetes.
Overnight Closed-Loop Insulin Delivery in Young People With Type 1 Diabetes: A Free- Living, Randomized Clinical Trial Featured Article: Roman Hovorka,
Alterations in White Matter Structure in Young Children With Type 1 Diabetes Featured Article: Naama Barnea-Goraly, Mira Raman, Paul Mazaika, Matthew Marzelli,
Performance of the DCA 2000 ® + Analyzer for Measurement of Hemoglobin A1 c Levels in Children with T1DM in a DirecNet Outpatient Clinical Trial.
The Diabetic Retinopathy Clinical Research Network Effect of Diabetes Education During Retinal Ophthalmology Visits on Diabetes Control (Protocol M) 11.
Achieving Glycemic Control in the Hospital Setting (Part 2 of 4)
Actigraphy Assessment of Mother’s Sleep : 6, 12 & 18 weeks postpartum Introduction: Janelle MacKenzie, Kerry Armstrong & Simon Smith Method: Results: Conclusion:
DirecNet Study of the Accuracy of the Navigator Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes Darrell Wilson 1,
The Physiological Variations of Plasma Glucose Concentrations in Healthy, Non-Diabetic Children: Use of Continuous Glucose Sensors Nelly Mauras, Roy Beck,
Special Situations In The Management Of In-Patient Hyperglycemia
TEMPLATE DESIGN © CONTINUOUS GLUCOSE MONITORING, ORAL GLUCOSE TOLERANCE, AND INSULIN – GLUCOSE PARAMETERS IN ADOLESCENTS.
Daniel A. Baur, Fernanda S. Vargas, Jordan A. Garvey, Christopher W. Bach, and Michael J Ormsbee, FACSM Institute of Sports Sciences and Medicine, Department.
Lauren M. Huyett, Eyal Dassau, and Francis J. Doyle III Department of Chemical Engineering University of California Santa Barbara Santa Barbara, CA
Glycemia Treatment Strategies Used In ACCORD
Making the Most of Continuous Glucose Monitoring
A Growth Curve Analysis Participant Baseline Characteristics
FreeStyle Libre Glucose Monitoring System
Management of Type II Diabetes
Volume 375, Issue 9716, Pages (February 2010)
Campbell FM, et al. Pediatr Diabetes. 2018;19(7):1294–1301
Baroreflex function measured by the modified Oxford method during baseline euglycemia (circles) and hypoglycemia (triangles). Baroreflex function measured.
Meal control achieved in the five meals of the study (the first dinner was handled in open-loop mode, and all other meals were handled by closed-loop).
Intranasal Glucagon Investigators
in Youth With Type 1 Diabetes
Presentation transcript:

Accuracy of the FreeStyle Navigator ™ Continuous Glucose Monitor Diabetes Research in Children Network Larry Fox, 1 Roy Beck, 2 Stuart Weinzimer, 3 Katrina Ruedy, 2 Craig Kollman, 2 Dongyuan Xing, 2 William Tamborlane, 3 Darrell Wilson, 4 Peter Chase, 5 Michael Tansey, 6 and the Diabetes Research in Children Network (DirecNet) Study Group. 1 Jacksonville, FL; 2 Tampa, FL; 3 New Haven, CT; 4 Stanford, CA; 5 Denver, CO; 6 Iowa City, IA Supported by NIH/NICHD Grants HD041919,HD041915,HD041890,HD041918,HD041908, HD041906; GCRC Grants RR00069,RR00059,RR06022,RR The FreeStyle Navigator™ is an investigational device only.

Abstract The Freestyle Navigator™ Continuous Glucose Monitoring System ("Navigator"; Abbott Diabetes Care, Alameda, CA) is a small, subcutaneous glucose sensor with wireless transmission to a monitor designed for continuous use. We evaluated the accuracy of the Navigator in 30 children (mean age 11 years) with T1DM in inpatient/outpatient settings. During a 24h CRC admission, subjects used 2 Navigators and prior to and after the admission used a single Navigator at home. Inpatient sensor values (N=1811) were paired with reference values (analyzed at a central laboratory) obtained every 30 minutes. Outpatient sensor values (N=6819) were paired with noncalibration glucose values obtained with a Freestyle® Flash™ (Abbott Diabetes Care, Alameda, CA). For inpatient use, the median absolute difference during hypoglycemia (≤70 mg/dL) was 14 mg/dL and the median relative absolute difference [RAD] was 13% during euglycemia ( mg/dL) and 10% during hyperglycemia (>180 mg/dL). Corresponding values for outpatient use were 15 mg/dL, 14% and 12%. In the inpatient setting, the median RAD was 15% in daytime versus 11% in nighttime, 11% during the first day versus 11% during the fifth day, and 11% with an arm insertion versus 12% with a hip and 13% with abdomen insertion. The median RAD comparing the two simultaneous sensors was 13%. In conclusion, these data indicate that Navigator sensor accuracy and precision are sustained for up to 5 days, are not degraded overnight and are similar in different insertion locations. Randomized controlled studies are needed to evaluate the clinical usefulness of this promising device in the management of children with T1DM.

Background The need for frequent blood glucose monitoring remains a barrier to achieving excellent diabetes control. An accurate, real-time continuous glucose sensor would provide valuable information in assessing postprandial excursions and changes in blood sugars during exercise.

FreeStyle Navigator ™ Continuous Glucose Monitoring System Measures interstitial glucose. Requires calibration using fingerstick blood glucose at 10, 12, 24 and 72 hours after sensor insertion. After a 10-hr warm-up, provides glucose readings every 60 seconds for up to 120 hours. Values range from 20 to 500 mg/dL. Displays trend arrow indicating glucose rate of change.

Study Aim This pilot study was designed to… Assess the accuracy of the FreeStyle Navigator™ Continuous Glucose Monitoring System (Abbott Diabetes Care, Alameda, CA) in inpatient and outpatient settings. Assess Navigator accuracy during exercise and during a missed bolus meal test.

Methods 30 children with T1D (4-17 yr old) were admitted to one of the 5 DirecNet clinical research centers (CRC). Outpatient accuracy was assessed before and after CRC admission. Two simultaneous devices were placed during the inpatient stay for assessment of precision; one device was inserted for subsequent outpatient data collection. Venous blood was obtained every 30 minutes during the CRC stay for sensor-reference comparisons.

Methods (cont’d) For some subjects, inpatient sensor glucose values were also compared with reference values obtained for ~2 hours during and following an exercise session and every 10 minutes for 1 hour following missed bolus breakfast test. Inpatient sensor glucose values were compared with reference values performed at the DirecNet central laboratory, using a hexokinase enzymatic method. Outpatient sensor data were paired with noncalibration glucose values obtained with the FreeStyle glucose meter built into the Navigator.

Methods (cont’d) The following differences between sensor and reference values were calculated: –median absolute difference (MAD) –median relative absolute differences (MRAD) The frequency of sensor values meeting ISO criteria was also assessed: –with reference glucose ≤75 mg/dL, sensor value within ±15 mg/dL –with reference glucose value >75 mg/dL, sensor value within ±20%

Results No effect of gender or BMI on inpatient or outpatient sensor accuracy (tables 2 & 3). Sensor accuracy was better for adolescents during home use (table 3) but was not affected by age during inpatient analysis (table 2). Inpatient and outpatient accuracy measures improved using a 10-minute sensor lag (tables 2 & 3).

Results (cont’d) No effect of sensor location or sensor age (up to 5 th day of use) on sensor accuracy during inpatient analysis (tables 4 & 5). Inpatient and outpatient sensor accuracy decreased with lower reference glucose values (tables 4 & 5). Sensor accuracy was better at night than during the day during inpatient and outpatient analyses (tables 4 & 5).

Results (cont’d) MRAD was slightly higher during exercise (17% vs. 12%), but this likely reflects the lower blood sugars rather than sensor inaccuracy (table 4). Tables 6 and 7 show inpatient and outpatient sensitivity and specificity of the sensor during hypoglycemia and hyperglycemia. 70% of the missed bolus breakfast glucose levels met ISO criteria, vs. 58% during exercise and 74% at other times.

Table 1. Demographics of study subjects* N30 Age11.2 ± 4.1 yr Female12 (40%) Caucasian28 (93%) HbA1c7.1 ± 0.6% T1D duration5.8 ± 3.0 yr *Age, HbA1c and T1D duration are mean ± S.D.

Table 2. Inpatient sensor accuracy: effect of age, gender, BMI, and lead/lag times. NMedian Diff.Median RADP value (RAD) % ISOP value (ISO) Overall1,811−212% 74% Age <11574−912%74% 11-< %73% 14-<18679−112%74% Gender Female 671−711%80% Male1, %70% BMI Percentile <50 th percentile119−29%92% 50 th -<75 th %71% ≥75 th percentile1,241−312%73% Lead/Lag Times<0.001* 20 min lead1,880016%61% 10 min lead1,853−114%67% No lead/lag1,811−212%74% 10 min lag1,861−311%78% 20 min lag1,874−411%77% 30 min lag1,915−413%71% * No lag vs. 10 min lag comparison

Table 3. Outpatient sensor accuracy: effect of age, gender, BMI, and lead/lag times. NMedian Diff.Median RADP value (RAD) % ISOP value (ISO) Overall863914% 66% Age < %65% 11-< %62% 14-< %70% Gender Female %67% Male %65% BMI Percentile <50 th %69% 50 th -<75 th %67% ≥75 th %65% Lead/Lag Times<0.001* 20 min lead %54% 10 min lead862417%59% No lead/lag863914%66% 10 min lag866013%70% 20 min lag %67% 30 min lag %58% * No lag vs. 10 min lag comparison

Table 4. Inpatient sensor accuracy: effect of reference glucose, sensor age, time of day and sensor location. Exercise test and meal challenge results are also shown. N Median Diff. Median RAD P value (RAD)% ISO P value (ISO) Reference Glucose ≤70 mg/dL %55% mg/dL1, %72% >180 mg/dL585−1910%81% Sensor Age <24 hours750011%78% 24-<48 hours395−812%77% 48-<72 hours326−817%61% 72-<96 hours %68% ≥96 hours156−211%81% Time of Day < daytime599014%67% nighttime1,212−211%77% Sensor Location Arm %77% Hip653−312%74% Abdomen571−413%72% Exercise Test %58% Meal Challenge293−2915%70%

Table 5. Outpatient sensor accuracy: effect of reference glucose, sensor age and time of day. N Median Diff. Median RAD P value (RAD)% ISO P value (ISO) Reference Glucose <0.001 ≤70 mg/dL %51% mg/dL %64% >180 mg/dL %74% Sensor Age <24 hours %62% 24-<48 hours %67% 48-<72 hours %66% 72-<96 hours159115%66% ≥96 hours %67% Time of Day <0.001 daytime %64% nighttime %68%

Table 6. Inpatient analysis of sensitivity and specificity of sensor during hypoglycemia and hyperglycemia. Sensitivity a False Positive Rate b Reference Events# EvaluableReference Value Hypoglycemia ≤70 N=47 ≤60 N=22 ≤50 N=1>70>80>90 60 mg/dL35%41%NA2335%22%13% 70 mg/dL49%55%NA3537%21%15% Hyperglycemia>200 N=145 >250 N=100 >300 N=55 <200<180< mg/dL97%100% 9125%16%5% 200 mg/dL83%100% 8818%9%4% a Percentage of hypo- or hyperglycemic events defined by the reference glucose for which sensor alarmed within ±30 minutes. b Percentage of hypo- or hyperglycemic events defined by the Navigator with reference value within ±30 minutes above or below the threshold level denoted in column heading and >10 mg/dL discrepant from the concurrent Navigator reading.

Table 7. Outpatient analysis of sensitivity and specificity of sensor during hypoglycemia and hyperglycemia. Sensitivity a False Positive Rate b Reference Events# EvaluableReference Value Hypoglycemia ≤70 N=911 ≤60 N=452 ≤50 N=148>70>80>90 60 mg/dL39%45%51%37527%17%12% 70 mg/dL62%70%81%64228%17%11% Hyperglycemia>200 N=2,279 >250 N=1,317 >300 N=674 <200<180< mg/dL93%96%97%52518%11%2% 200 mg/dL87%93%96%57112%4%1% a Percentage of hypo- or hyperglycemic events defined by the reference glucose for which sensor alarmed within ±30 minutes. b Percentage of hypo- or hyperglycemic events defined by the Navigator with reference value within ±30 minutes above or below the threshold level denoted in column heading and >10 mg/dL discrepant from the concurrent Navigator reading.

NavigatorReferenceMAD Baseline glucose 161 (118, 220)172 (122, 239)23 (17, 36) Glucose nadir 82 (41, 101)86 (51, 113)17 (8, 28) Minutes to nadir 100 (70, 110)75 (55, 78)22 (13, 42) Rate of change 0.8 (0.5, 1.1)1.4 (0.7, 1.8)0.4 (0.2, 0.8) * Values are median (25th, 75th percentile). Rate of change is mg/dL/min; MAD = Median Absolute Difference (Navigator – reference value). Table 8. Blood glucose levels during exercise * (N=19)

Figure 1. Navigator vs. laboratory measured drops in glucose (mg/dL) during exercise. Reference Navigator

Figure 2. Navigator vs. laboratory rate of change in glucose (mg/dL/min) during exercise. Reference Navigator

Conclusion Navigator accuracy is similar during inpatient use and when used at home. The Navigator sensor is accurate during exercise and during a missed bolus postprandial state. Navigator sensor accuracy is sustained for up to 5 days, and is similar in different insertion locations. Randomized controlled studies are needed to evaluate the clinical usefulness of this promising device in the management of children with T1DM.

Barbara Davis Center –H. Peter Chase –Rosanna Fiallo-Scharer –Laurel Messer –Barbara Tallant University of Iowa –Eva Tsalikian –Michael Tansey –Linda Larson –Julie Coffey –Joanne Cabbage Nemours Children’s Clinic –Tim Wysocki –Nelly Mauras –Larry Fox –Keisha Bird –Kim Englert Stanford University –Bruce Buckingham –Darrell Wilson –Jennifer Block –Paula Clinton Yale University –William Tamborlane –Stuart Weinzimer –Elizabeth Doyle –Heather Mokotoff –Melody Martin –Amy Steffen Jaeb Center for Health Research –Roy Beck –Katrina Ruedy –Craig Kollman –Dongyuan Xing –Cynthia Stockdale