C LIMATE C ORPS B AY A REA 2012 T RAINING Kif Scheuer.

Slides:



Advertisements
Similar presentations
Gorokan Public School Energy Saving Plan Put your school logo here March 2010 These Stage 3 students conducted an energy use audit.
Advertisements

Exploring Energy Management
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2F: Lighting.
Saving Energy 3. Energy Choices 4. Taking Action 5. Efficiency Tricks Energy Sources.
Step Up Payback Proposal Program “How-To” 9/4/07.
VampirePowerAKA Standby Power Phantom Load Phantom Load or or Leaking Electricity.
AP ENVIRONMENTAL SCIENCE
Non-Res Lighting Subcommittee Retrofit Lighting Standard Protocol Review 10/23/13.
Energy Assessment Spreadsheet Ashok Kumar Somik Ghose Rahul Pendse Charanya Varadarajan.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
LED Case Lighting With and Without Motion Sensors Michele Friedrich – Sr. Engineer PECI 1/5/2010.
Your School Energy Saving Plan Put in photos of people who did the audit on this slide Put your school logo here Date.
Circuit Design Magic of Electrons © 2011 Project Lead The Way, Inc.
2009 CAMPUS LIGHTING RETROFIT FORUM Laboratory Lighting Controls Upgrade New Laboratory Building Biological Sciences 3 Beat Title 24 Energy Standard by.
SNAP CIRCUITS INSTRUCTIONS 1.Make sure ALL parts are in place before beginning 2.Follow the Projects in order, starting with #1 3.The BLACK numbers show.
DEVELOPING AN ENERGY AND SUSTAINABILITY POLICY FOR HARNETT COUNTY SCHOOLS.
10.2: Electricity and Electric Circuits. Static vs. Current Electricity Static Electricity: charges build up in one location Current Electricity: electrons.
Who Says Energy Efficiency Can’t be Sexy? About Us Energy + Environment  Since 1999  Decades of experience in energy efficiency  We create jobs, lower.
April, 2002Energy Audits1 Heating Degree Days The difference between the base temperature (balance point) and the mean ambient temperature for the day.
Electrical Energy.  Electrical energy is the energy transferred to an electrical device by moving electrical charges. The energy used at home is measured.
E NERGY S TAR  Purchasing Save Money Lower Energy Bills Reduce Air Pollution.
LED Case Lighting in Vertical and Semi-Vertical Open Refrigerated Cases Eric Mullendore – Energy Analyst PECI 6/29/2010.
Electrical Circuits. A path where electric charges move along (through wires).
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Smart Power Strips in Commercial Office Applications RTF October 4, 2011.
C LIMATE C ORPS B AY A REA 2012 T RAINING Day 3. C LIMATE C ORPS B AY A REA 2012 T RAINING Questions from yesterday Logistics for today.
NOTES 17 - Circuits What is a circuit? Circuit – a pathway for electric current to travel through.
Energy Management in Buildings Tony Golding. IMPLEMENTATION OF ENERGY MANAGEMENT Appointment of an energy manager (engineer) Production of an energy management.
Day 10 Environmental Systems I Daylight as a primary lighting source Artificial lighting as a secondary source Room 102 Architecture Building.
IMPORTANT ELECTRONIC TERMS. Voltage "V" A measure of electrical potential, it is measured in volts A measure of the pressure under which electricity flows.
Energy Conservation Initiatives Joan Kowal Energy Manager, UMCP May 1, 2008.
Demand Side Energy Management & Conservation Lighting Retrofits The University of Texas at Austin.
Lighting and Electricity By: Allie Sirrine, Apoorva Vijayakumar, Chris Jellison and Gary Lorden.
Why should we save energy? Americans now spend over $700 billion on energy Americans now spend over $700 billion on energy Energy demand is expected to.
T12 to HPT8 Change-outs Small/Rural request for development May 15, 2012.
Learning about Electrical Components
EXPLORING ENERGY MANAGEMENT. PROJECT TITLE What is Energy Management? Energy management is doing more with the same amount of energy or less energy. Energy.
Advanced Energy Engineering Technology Modeling Building Energy Systems Session 7: Lighting and daylighting.
SNAP CIRCUITS INSTRUCTIONS 1.Make sure ALL parts are in place before beginning 2.Follow the Projects in order, starting with #1 3.The BLACK numbers show.
 Phantom Load: The power used by something while turned off Another word for phantom load is standby power.
Lighting Efficiency. Lighting Efficiency Problem Suppose that 25 incandescent light bulbs rated at 100 Watt are replaced by 25 fluorescent lamps rated.
Lighting Beyond the Bulb LED Lighting and Lighting Management Solutions Todd Smith
Lighting facts.  Lighting can be a big energy consumer in offices and production areas and experience shows that energy savings may be achieved - often.
Section 7.3 Electrical Energy Circuits are pathways for electricity to flow. – Unlike static electricity, which is short-lived and fast, current flowing.
Forging new generations of engineers. USING THE STRESS ANALYSER FOR TENSILE TESTING.
Circuits Chapter 17.3 Notes. What are circuits? An electric circuit is a set of electrical components connected such that they provide one or more complete.
Energy Conservation. What is a Watt? Unit of measurement for power Amount of energy per time Used to measure amount of energy used Usually measured in.
Cost of lighting Facts $14B in Rate Freezes expiring now National Average nearing 10¢ kwh Lighting Represents % of Utility Bills Investment required.
Central High School Green Team The Lauderdale County School System is partnering with The Alliance to Save Energy out of Washington, D.C. and.
Energy Efficiency & Pollution Prevention Opportunities April 2016 Cheryl Eakle, CEM Sr. Sustainability Engineer.
Combination Artificial & Daylighting
Eco Friendly Television
Circuit Design Circuit Design Gateway To Technology®
CAPE & OUR PPN HISTORY IN BUSINESS SINCE 1953, PPN MEMBER SINCE 2014
Electric Circuits (12.2).
Electric Circuits (12.2).
Basic Electrical Circuits
SNC1D PHYSICS THE CHARACTERISTICS OF ELECTRICITY
Exploring Energy Efficiency & Conservation
Circuit Design Circuit Design Gateway To Technology®
Electric circuits Charge and Current.
Exploring Energy Management
Energy Consumption at Home
Exploring Energy Efficiency & Conservation
Exploring Energy Efficiency & Conservation
Electrical Quantities
Exploring Energy Management
Exploring Energy Efficiency & Conservation
Exploring Energy Management
Putting Energy Into Education
Basic Electrical Circuits
Presentation transcript:

C LIMATE C ORPS B AY A REA 2012 T RAINING Kif Scheuer

C LIMATE C ORPS B AY A REA 2012 T RAINING Types of Linear Fluorescent Light Fixtures

C LIMATE C ORPS B AY A REA 2012 T RAINING Components of Fluorescent Lighting System Lamps Ballast Light Fixture

C LIMATE C ORPS B AY A REA 2012 T RAINING Types of Linear Fluorescent Lamps Source: T12 T8 T5 T2

C LIMATE C ORPS B AY A REA 2012 T RAINING T8 Lamps Lamp Type fixture Watts 24" T8 1 lamp 15 24" T8 2 lamp 28 24" T8 3 lamp 41 24" T8 4 lamp 57 36" T8 1 lamp23 36" T8 2 lamp 42 36" T83 lamp62 36" T8 4 lamp 84 48" T8 1 lamp 25 48" T8 2 lamp 54 48" T8 3 lamp73 48" T8 4 lamp94 T8/U-bend 1 lamp27 T8/U-bend2 lamp52 T12 Lamps Lamp Type fixture watts 24" T12 1 lamp28 24" T12 2 lamp56 24" T12 3 lamp62 24" T12 4 lamp112 36" T121 lamp 32 36" T12 2 lamp 65 36" T12 3 lamp " T124 lamp " T12 1 lamp 40 48" T12 2 lamp 72 48" T12 3 lamp112 48" T124 lamp 142 T12/U-bend1 lamp34 T12/U-bend2 lamp66

C LIMATE C ORPS B AY A REA 2012 T RAINING Spin the flicker checker Choppy, checkered pattern= magnetic ballast = T12 lamp Concentric, gray rings = electronic ballast = T8 lamp

C LIMATE C ORPS B AY A REA 2012 T RAINING T12 vs T8 Activity Activity Instructions : Break up into teams of 3-4, grab a flicker checker, and select a specific site to conduct a linear fluorescent light audit, specifically looking at existing T12/T8 lamps in the building. Use the worksheet provided to collect information on the study site’s existing lighting condition. Calculate the potential electricity, cost, and GHG savings associated with upgrading the existing lighting conditions, if an upgrade is needed.

C LIMATE C ORPS B AY A REA 2012 T RAINING Energy Audit #3 - Delamping: What is it, and why is it important?

C LIMATE C ORPS B AY A REA 2012 T RAINING Source: Illuminating Engineering Society Developed by the Illuminating Engineering Society

C LIMATE C ORPS B AY A REA 2012 T RAINING How To Use It Make sure the sensor is covered. Check that the “Range” switch is selected to A Turn on the “Power” button. Remove the sensor cover. Read the lighting level. Readings should be taken at the level where the work occurs. Make sure user does not cover the sensor How To Use It Make sure the sensor is covered. Check that the “Range” switch is selected to A Turn on the “Power” button. Remove the sensor cover. Read the lighting level. Readings should be taken at the level where the work occurs. Make sure user does not cover the sensor

C LIMATE C ORPS B AY A REA 2012 T RAINING Layout of room: Sample light levels collected from room: 3 linear fluorescent fixtures Light Meter Activity Conduct a light analysis of the room/building you are in. Example:

C LIMATE C ORPS B AY A REA 2012 T RAINING Light Meter Activity Activity Instructions : Break up into teams of 3-4, grab a light meter, select a specific site to conduct a light meter analysis in the building. Draw a floor plan of the study site as shown in the previous slide, and write down different light meter levels (foot-candles). Collect at least 6 light meter levels in different parts of the room. Based on the recommended lighting level, assess if there is too much/too little light in the study site, and what next steps you would recommend to the facilities staff to help them save energy.

C LIMATE C ORPS B AY A REA 2012 T RAINING What’s a plug load ? Plug loads make up about 4% of all electricity use in the US What’s a run watt ? Power drawn by a plug load while in operation What’s a phantom load? Aka energy vampires, standby loads U.S. consumption of phantom loads = electricity use of Greece, Peru, and Vietnam, combined. Phantom load on this printer is 2.8 watts. This translates into _______kWh a year.

C LIMATE C ORPS B AY A REA 2012 T RAINING

Activity Instructions: Break up into teams of 3-4 and pick at least one plug load and one watt meter. Using the handout, calculate the run watts and the phantom load (if any), along with the associated annual energy use, cost, and GHG emissions. Handout: