1 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Objectives By end of this module you should able to: Know What Really.

Slides:



Advertisements
Similar presentations
Cabling system components
Advertisements

Cable Management.
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
Telecom Cabling Grounding and bonding.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
Condensation Piping and Installation Drain Pans
Guide to Network Cabling Fundamentals
Telecommunications cable types
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Classes of transmission media
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
Electrical Power Systems
Electrical Principles and Wiring Materials
1 Telecom Cabling CATV systems and coax cable. 2 Telecom Cabling Community antenna TV is covered in the NEC article 820, and is covered in a limited capacity.
Router. Switch Repeater Cable is the medium through which information usually moves from one network device to another. It used to connect one network.
1 INTRUSION ALARM TECHNOLOGY CABLING FOR BURGLAR ALARMS.
 Volt- Is the measurement unit of the electrical potential.  Electrical Potential- The difference of voltage between two points in a circuit. It is.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Electrical Installation II
Electrical Principles and Wiring Materials
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
INTRUSION ALARM TECHNOLOGY
Technician License Course Chapter 5 Amateur Radio Equipment Lesson Plan Module 12: Power Supplies and Batteries & RF Interference (RFI)
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Communication channels and transmission media
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Electrical Installation 2
Physical Transmission
Electrical Principles and Wiring Materials Unit #31.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
Electricity By: Mr. Brock. Electrical Safety 1) Always disconnect the circuit to be worked on before anything else and lock the cover to the SEP when.
Electrical Principles and Wiring Materials
 Cables  Network Interface Card (NIC)  Repeaters  Hubs  Switches  Routers  Gateways  Bridges.
COMMUNICATIONS AND CONTROL SYSTEMS. Interior Designer must know: Client’s priorities How space will be used Where equipment is located Location of phones,
Ag. Mechanics for Beginning Teachers
Network Media. Copper, Optical, Fibre (Physical Layer Technologies) Introduction to Computer Networking.
Variable Frequency Drive (VFD) Cable VFD Cable Solutions.
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
ELECTRICAL WIRE- ARTICLE  Electrical wire in a term used to describe insulated conductors employed to deliver electricity. The.
Cable 101 The basics of wire & cable ©Copyright 1997, Belden Inc.
Official Association Sponsor
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Electrical Wire Identification
NICET Fire Alarm Tech Level 1 Practice Test # 6
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Agricultural Systems Technology II
NEMA RV 3 Application & Installation Guidelines For Flexible & Liquid Tight Flexible Metal Conduits
Engineering Project Cable Management.
NICET Fire Alarm Tech Level 1 Practice Test # 10
Overcurrent Protection— Fuses and Circuit Breakers
MTW Rated Wire and Cable
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
POWER SYSTEM-II (III-1)
ELECTRICAL INSTALLATION
Electrical Principles and Wiring Materials
Presentation transcript:

1 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Objectives By end of this module you should able to: Know What Really Matters in Selecting the RIGHT Fire Alarm Cable… Identify the application. Know your cable ratings and where will the cable be installed. Fire alarm cable requirements – NEC Article 760 Cable substitutions Understand the type of system - EMI & RFI sensitivity. Identify the CCI Fire Alarm Cable Needed Plenum, Riser or General Purpose Shielded or Unshielded Determine the CCI part# for your application

2 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Identify the Application Fire Alarms Fire Detection & Alarm Notification Guard’s Tour Sprinkler Water Flow or Sprinkler Supervisory Systems

3 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Fire Alarm Cables NEC Article 760 (Fire Alarm Systems) Applies to the installation of wiring & equipment of the fire alarm systems including all circuits controlled and power by the fire alarm system. Ratings FPLP – (Plenum Rated) For use within buildings in ducts, plenums or other environmental air spaces. FPLR – (Riser Rated) For use in within buildings in vertical shafts FPL - General use in buildings KNOW YOUR LOCAL AND NATIONAL ELECTRICAL CODES!

4 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Article 760 Cable Substitutions Type CM – Communications wire & cable Type FPL – Power-limited fire alarm cable Cable A shall be permitted to be used in place of B For example, a CMR cable can be substituted for a FPLR cable, but a FPLR cable can not be substituted for a CMR cable. Cable Substitution Hierarchy

5 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Plenum vs. Riser Plenum Plenum spaces are defined as any space used as a return passage for environmental air. The wiring is not required to go through conduit – (unless Chicago or New York) Fire resistant and low smoke producing characteristics “Non-Plenum” does not necessarily mean “Riser,” some low-end products are also not riser. Access Shaft Floor Structural Support Air Return Suspended Ceiling Air Supply Duct Plenum Air Handling Space Plenum Cables Riser (or Plenum) Cable

6 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE FPLP – Plenum Rated For use in Plenums, ducts, or other environmental spaces Anywhere a building cavity is used as air return The wiring is not required to go through conduit (unless Chicago/New York) Fire resistant, low smoke producing Most preventative in spread of fire from floor to floor Must meet NEC Article 760 Must pass UL test 1424 and UL tunnel test 910 Most commonly used in commercial installations Low flame spread, low smoke producing characteristics FPLP rated cables can be used in general purpose, riser or plenum applications Using riser rated cables in plenum applications is prohibited

7 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Type of System Is the system microprocessor based and therefore sensitive to EMI and RFI? If EMI and RFI are not a concern… If the system is computer based, signal interference will be a concern… SHIELDED cables will protect the circuits from this outside interference and keep the signal constant. UNSHIELDED cable are suitable. ***For compatibility verification of the cable type, refer to the equipment manufacturer’s recommendations.

8 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Shielded vs. Unshielded Unshielded Cables Cost effective for areas where interference (EMI) is not a concern Shielded Cables Offers excellent protection against RFI & EMI RFI – Radio Frequency Interference (such as cell phones, radio towers or garage door openers) EMI – Electro Magnetic Interference (caused by electric motors, ballasts, & other high voltage currents) Shielded cables should be used when installing near dimmer panels, light switches, in parallel runs, near neon or fluorescent lights and near power cables

9 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Cabled vs. Straight Lay Cabled Reduces crosstalk interference from other signals (inside or outside the cable) Also referred to as “twisted” cables Most commonly used in fire alarm systems The majority of CCI products are cabled to cover a wide range of applications and prevent having to stock/manage duplicate sku’s Straight Lay Cost effective for areas where interference is not a concern Also referred to as “parallel” cables

10 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Stranded vs. Solid Stranded More flexible Reduces potential conductor breakage from repeated flexing Solid Industry standard for most fire alarm cable Easier to terminate Easier to solder Lower cost Less attenuation / signal loss

11 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Distance & Capacitance Distance cable will run Voltage drop should be calculated or refer to equipment manufacturer’s recommendations Knowing the distance the cable will run also helps identify the right gauge size cable to select. Larger gauge for longer runs Capacitance The capacity of the insulation to hold an electric charge Often, lower capacitance (Picofarrads/foot = pF/ft) translates to a higher performance cable May need to meet requirements for specific hardware systems.

12 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Fire Alarm Cable Requirements All installations must follow guidelines established by the National Electric Code. Below are some basic practices to remember when installing power-limited fire alarm systems. For a more in-depth review of requirements and installation guidelines, refer to the NEC Code Book. 1.All cables must be listed by a Nationally Recognized Testing Lab (UL, ETL, CSA, etc). Check all cables for the proper markings. Refer to NEC Article Comply with local wiring requirements. 3. Only use conductors made of copper. 4. Test wiring for grounds, short circuits, and open faults before the system is placed in operation. 5. Always use the proper gauge of wire to avoid signal loss. 6. Avoid interference when routing wire. 7. Installation shall be made to prevent the spread of fire from floor to floor. 8. A minimum of 6 inches of free conductor is required in each electrical box to facilitate termination. 9. All wiring must be terminated with listed devices.

13 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Fire Alarm Cable Construction LEGEND These 4 must appear on all cables Nationally Recognized Testing Lab Standard DRAIN WIRE Included on all shielded constructions, used to ground the shield. JACKET PVC Plenum cables are constructed with low-smoke PVC Tubed or Extruded Jacket INSULATION PVC Polypropylene SHIELDING Aluminum Backed Mylar Size Conductors Listing Agency Mfg. ID NEC Rating Mfg Date Part# Footmarking Mfg.

14 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Brand Recognition Coleman Cable’s brand Leader in Security, Sound and Fire industries for more than 20 years Manufacturing Capabilities Coleman Cable’s Electronic Cables are produced in our ISO 9001:2000 Certified facilities Product Differentiation Dual Rated Polypropylene Insulation Rip cord for ease of stripping Sequential footage marking to eliminate guess work Rabbit Pull – High Speed Dispensing System Market Position Strength/Position with Electrical Contractors and Security Installers Why Signal for Fire Alarm?

15 of 15 Coleman Cable, Inc. Copyright © 2006 All Rights Reserved. FIRE ALARM CABLE Congratulations! Congratulations! You should able to: Know what really matters in selecting the RIGHT fire alarm cable. Identify the CCI fire alarm cable needed Select the CCI part# needed for your application