The World’s Most Reliable Air Sampling Pumps. Introduction to Gilian Gilian air sampling pumps are manufactured by Sensidyne in Clearwater, Florida. Product.

Slides:



Advertisements
Similar presentations
SPOTLIGHT ON THE SKC AIRCHEK® XR5000 PUMP
Advertisements

Catalyst Chemical Injection Systems. Catalyst System Family.
An innovative tool for the review of health and safety work practices and the implementation of effective controls of particulate exposures.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
… for Combustible Gas Detection S4000C Intelligent Sensors..
Cyclones A CENTRIFUGAL FORCE IN AIR SAMPLING
Gilian Air Sampling Pump Field Calibration
SPOTLIGHT ON THE LELAND LEGACY ® PUMP FROM THE LELAND LEGACY PUMP Provides answers to particulate sampling problems. High flow rates + 24-hr run times.
SPOTLIGHT ON THE SKC AIRCHEK ® XR5000 PUMP. THE SUPERCHARGED SKC AIRCHEK XR5000 The FIRST personal sampling pump with a lithium-ion battery option. Experience.
Acculab „Exceleron“ Acculab “Exceleron “ Series Multi-functional Industrial Scale Line Multi-function Industrial Scale.
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
QuadMode SM Simultaneous Sampling. Reliable Performance & Innovative Features for Dependable Results  High performance – cc/min flow range.
OSHA Personal Air Sampling Presented By: Joseph Cantone Industrial Hygienist/Project Manager.
= ( es ) 2 energy savings. 53% SAVINGS* THAN OTHER LEADING INVERTERS! Best Energy Savings! High 11+ EER CASSETTE INVERTER FLOOR STANDING INVERTER HIGH.
Trimble TS600 Series Total Stations
1 Evaluation of Historical Methods for Determination of Total Volumes Collected in RETS/REMP Air Monitoring Applications with Currently Available Technology.
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
Gas Detector Tubes Low-cost Detection of Hazardous Gases & Vapors.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
New Gilian LPM Air Sampling Pump. Gilian 5000 Features Our most powerful 5 LPM pump Digital flow display with 30-day calibration Meets EN 1232.
Gilian Air Sampling Pumps If they were any tougher they would beat you up and take your lunch money.
Smart battery technology for a global environment Louie Lane #104 Reno, Nevada
Representative Sampling By Chuck Abbott. Automatic Samplers.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Geotechnical Services With Gilian/Sensidyne
Component Rebuilds John Richards Cashman Product Support Representative Lyle Kibbe Cashman Service Supervisor A Guided Tour Through Cashman Equipment.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
CONTENT S ⅠⅠ Characteristics of CANDU Reactor & Tritium ⅡⅡ Tritium Measurements ⅢⅢ Needs of the equipment development ⅣⅣ Automatic Multiple Tritium Sampler(AMTS)
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
Presented to: Name of Customer Enhanced MET ONE 3400 Series Portable Airborne Particle Counters.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Antek 6200 ® Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation.
The New Adventurer Pro Is Here!. What’s New? Bright alphanumeric dual line display Better weighing cell and weighing performance 7 application modes Better.
Gilian Air Sampling Pumps The World’s Most Reliable Air Sampling Equipment.
Quality assurance of sampling and analytical instruments
Introduction to BGI Instruments
High Sensitivity Smoke Detection
SPT-Soft Pack Technology. Produce the best HPLC columns !
Calibration Savvy. Calibration and Conformance  Calibration: Check a measurement against a known universally recognized standard to determine any deviation.
Measurement of total mass concentration. 1. Sampling probe - Isokinetic or sampling from still air 2. Flow rate - Rotameter or digital flowmeter 3. Filter.
Continuous Particulate Training Workshop
NAVIGATOR™ Portable Balances
Ultra Sonic 2001 Touch Free Car Wash RYKO Manufacturing Company.
WBEA Passive Sampler Validation Study for NH3 and HNO3 Operation of the dual-channel Annular Denuder System (ADS)
Houston Material Handling Society October 2008 Baghouse Cleaning Control Presented by: T.J. Winalski.
AJ5812 ENTERAL FEEDING PUMP
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
Constant Flow Pumps. Pump is an “air-mover” used to draw air Pump is an “air-mover” used to draw air  Through filter medium(ex. impinger)  Into collection.
IH&S 725 Dr. Myers, C.I.H. Quality assurance of sampling and analytical instruments Lecture Notes.
Challenger NIST Traceable Air flow Calibrator. Features Dry air flow calibrator No moving parts NIST Traceable Actual & Standard Conditions 1 LPM to 30.
SKC Inc. The Basics of Air Sampling Step-by-Step.
Personal Air Sampling for Crystalline Silica Exposure
E VERY L IFE H AS A P URPOSE… Instrument Selection.
It’s…….
C1300 advanced circular chart recorder
Filter Media-PVC.
SPOTLIGHT ON THE LELAND LEGACY® PUMP FROM
IN SAMPLE PUMP INNOVATION
IS FOR HAZARDS AT HOSPITALS
Instrument Maintenance
-By Maniks
Pulse valve manufactured by Maniks
Dust Collector Valve for Dust Collection System - Maniks
The FG series of explosive and toxic gas detectors and panels
SKC IS PROUD TO INTRODUCE A NEW LOW FLOW SAMPLING PUMP
SKC IS PROUD TO PRESENT SAMPLE PUMPS FOR A NEW GENERATION
IN SAMPLE PUMP INNOVATION
SKC CHEK-MATE CALIBRATOR
Presentation transcript:

The World’s Most Reliable Air Sampling Pumps

Introduction to Gilian Gilian air sampling pumps are manufactured by Sensidyne in Clearwater, Florida. Product line includes personal and area air sampling pumps for the evaluation of worker exposure to airborne hazards during the work shift.

Air Sampling Introduction Air sampling pumps draw air through collection media for the evaluation of worker exposure to a targeted substance during the work shift. Samples are collected using a filter cassette or sorbent tube then later analyzed in a lab.

Meet the Gilian Family

Gilian 3500 Constant flow LPM Low flow cc/min High back pressure capability NiMH battery Digital live flow display Intuitive operation with lock out code Intrinsically safe certified ATEX and UL

Gilian 5000 Constant flow: cc/min Low flow: cc/min Highest backpressure capability Memory free NiMH battery Programmable functionality –Four stage program with repeat cycling –Allows scheduled sampling or intermittent duty cycles –Programmable delayed start Digital live flow display En1232 Compliant – 3rd party verified Intuitive operation with lock out Intrinsically safe certified

Gilian 5000 Constant Flow Gilian 5000 Gilian 3500 GilAir-3 GilAir-5 HFS inches H2O 35 inches H2O 20 inches H2O* 37 inches H2O 40 inches H2O * Spec at 2.5 LPM Compare at 2 LPM

Gilian 5000 Back Pressure Gilian 5000 Gilian GilAir-5 Gilian HFS-513 SKC AirChek XR-5000 Casella APEX Pro Buck VSS-5 20 inches H2O 10 inches H2O 15 inches H2O 10 inches H2O Free flow 2 inches H2O Capability at 5 LPM

Gilian GilAir-3 Constant flow: cc/min Low flow: cc/min Rechargeable battery pack Built-in rotameter & flow adjust Multiple sorbent tube capability Programmable LCD timer Instant-fault function Compact, lightweight, & quiet UL listed intrinsically safe ATEX & CE approved

Gilian GilAir-5 Constant flow: cc/min Low flow: cc/min Rechargeable battery pack Built-in rotameter & flow adjust Multiple sorbent tube capability Programmable LCD timer Instant-fault function Compact, lightweight, & quiet UL listed intrinsically safe ATEX & CE approved

Gilian LFS-113 Constant flow: cc/min Multi-tube flow: cc/min Elapsed time clock Built-in sorbent tube breaker Multi-tube sorbent tube sampling capability Suction and Bag Filling sampling Instant-fault functions Battery check LEDs Rechargeable Battery Pack

Gilian BDX-II Low-cost designed for use with asbestos and lead sampling Flow: cc/min Rechargeable battery pack Built-in rotameter & flow adjust Compact, lightweight, & quiet Meets NIOSH 7400, 7082, 7105 and 7300 specifications Full one-year warranty

Gilian AirCon-2 Constant flow: 2-30 LPM DC or AC Powered Fully programmable for custom and unattended sampling Touchpad & LCD display Instant fault function Instant pressure check Charges battery while in AC operation

High Flow vs. Low Flow High Flow Flow rates from 1 - 4LPM Examples: –Lead –Asbestos –Dust Accessories –Filters –Cyclones –Impingers Low Flow Flow Rates from cc/min Examples: –Hydrocarbon Solvents (Benzene) –Chlorinated Solvents (Methylene Chloride) –Alcohols Accessories –Sorbent Tubes –Charcoal Tubes

Low Flow Adapter Provides constant low flow for GilAir-3 & GilAir-5 Maintains low flow within ± 5% of set flow Single samples, adjust flow on the module.

Multi-flow Low Flow Pumps Constant Pressure control allows two to four simultaneous samples using special manifolds. Constant (NEG) Pressure (-18” +/-3”) is maintained in the tubing. Flow rate is controlled with a needle valve on each tube holder.

Cyclone Samplers Impingers Charcoal Tubes Filter Cassettes Air Sampling Accessories Inhalable Collectors Bag Filling

Gilian Gilibrator-2 True Primary Standard NIST traceable Easy Set-Up and Operation Microprocessor Controlled Field Portable Low Maintenance Alphanumeric Display Built-in RS-232 Port Auto Averaging of readings Battery or AC operation

Measuring Back Pressure

Back Pressures of Popular Filters

Use This Tool To Sell The Gilian Diagnostic Panel shown built into the rear of a Gilibrator kit, is an essential tool to confirm Gilian performance Reveal failures of customers’ existing pumps

Gilian Diagnostic Panel Lab Stand “The Panel” alone may be used to illustrate Gilian performance and discredit performance specifications claimed by other competitors The panel is a useful tool in any repair lab. Serious Gilian Sales Partners own and use the GDP

The LFS Pump is adjusted to desired flow rate e.g. 70cc/mn, the needle valves V3 or V4 are adjusted to desired starting back pressure representing sample start with clean sorbent tube or media. Flow stabilizes as read on the flowmeter and Gilibrator, and is recorded. Then the technician slowly adjusts V3 or V4 increasing back pressure to replicate a loaded filter and end of the day buildup. The Flow is then checked again and verified to be within +/- 5% of initial flow setting. This is testing constant flow!

Gilian Challenger Dry Calibrator No moving parts 1 LPM to 30 LPM Fast setup and use Portable and light weight High accuracy: +/ % Actual & standard conditions NIST traceable with certificate

The Gilian Family

Key Markets Refineries Chemical plants Utilities Construction sites Foundries Lead & asbestos abatement Insurance Companies Consultants

/