EPOCH 1000 Series Procedure Custom PA Probe-Wedge Definition.

Slides:



Advertisements
Similar presentations
EPOCH 1000 Series Software Feature AWS D1.1/1.5
Advertisements

EPOCH 1000 Series Procedure Conventional Straight Beam Calibration
EPOCH 1000 Series Procedure Conventional Angle Beam Calibration
EPOCH 1000 Series Software Update New Features - March 2010.
When the Easy Fridge/Freezer Alarm is plugged into the wall it will ‘boot up’ and display the System Setup Menu Parameter menu will appear where you will.
September, 2004Patient Care Inquiry PCI - Customizing Your Patient ID Menu.
PRESS C7000/C7000P/C6000 Color Density Control Color Balance
Page and Section Breaks, Word 2000
 novel gmbh 2001 April 2001novel projects 9.3 novel projects novel gmbh Ismaninger Straße Munich Germany
EPOCH 1000 Series Procedure Multi-Angle Feature. Feature Overview and Activation.
Copyright Albion Devices, Inc., Demonstration of MicroComp micro-computer gaging system from Albion Devices, Inc.
EPOCH 1000 Series Procedure Phased Array DGS/AVG
EDSM II Training. EDSM II EDSM II (Enhanced Digital Select Module) is a hand held program module used to program Atlas laundry dispensers –Recommended.
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
Guide to Oracle10G1 Introduction To Forms Builder Chapter 5.
This presentation contains the following: -the availability and need menu options -the add option Mark Smith.
A Guide to Oracle9i1 Introduction To Forms Builder Chapter 5.
Customizing Word Microsoft Office Word 2007 Illustrated Complete.
XP New Perspectives on Microsoft Office Word 2003 Tutorial 1 1 Microsoft Office Word 2003 Tutorial 1 – Creating a Document.
Training Guide. The Punch Out Catalog System The Punch Out shopping catalog for West Press takes the user directly into the vendor’s website and online.
XP 1 Microsoft Office Word 2003 Tutorial 1 – Creating a Document.
EPOCH 1000 File Management Data Logging and Reporting
20 February Set Up Access Groups. 20 February Access Group Definition Combines time zones and doors into groups of where and when access can.
Navigation 1 GPS for ICS Navigation 1 Objectives:  Set up a Garmin GPS III Plus for inputting coordinates.  Manually enter three sets of coordinates.
Plex Training. 2 Course Objectives Learn how to Log on and Change Passwords in Plex Learn the Common Functions on the Control Panel Learn how to Log into.
Setting up the NICO monitor to measure pulmonary dead space fraction (V d /V t )
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
Click to edit Master title style A tool designed to provide useful information and assist Propex Plus Partners!
EPOCH 1000 Series Software Update New Feature Overview - February 2011.
EPOCH 1000 Series Software Update New Feature Overview July 2012.
APOLLO GX50/55 GPS Basic Operations. Introduction  This presentation is designed to introduce the basics of the GX50/55 GPS  Focus will be placed on.
Microsoft Office Word 2003 Tutorial 1 Creating a Document.
Using the Georgia Online Assessment System(OAS) We will lead the nation in improving student achievement. Kathy Cox, State Superintendent of Schools.
FROST I Site Initiation Visit version 1.4. IVTM System.
EPOCH 1000 Series Procedure Linear Scan and C-scan.
1 ADVANCED MICROSOFT EXCEL Lesson 9 Applying Advanced Worksheets and Charts Options.
GCS 300 System Operation Application – Level 1.
TxEIS Security A role-based solution October 2010.
Data entry: Validation
© 2010 South-Western / Cengage Learning Century 21 Keyboarding  Cycle 1  Office Features 1.
Background Due to the way that the Echelon console calculates watts, it is possible that physical differences between bikes will result in differences.
© 2008 The McGraw-Hill Companies, Inc. All rights reserved. ACCESS 2007 M I C R O S O F T ® THE PROFESSIONAL APPROACH S E R I E S Lesson 2 – Viewing and.
1 Extend is a simulation tool to create models quickly, with all the blocks you need and without even having to type an equation. You can use a series.
EPOCH 1000i Feature Overview Weld Overlay. Weld Overlay Display Feature.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
COMPREHENSIVE Access Tutorial 12 Managing and Securing a Database.
® Microsoft Access 2010 Tutorial 12 Managing and Securing a Database.
ResponseCard XR Answering Questions. Polling The host computer must be able to receive your responses, but it can only do so when the polling is open.
6 th Annual Focus Users’ Conference 6 th Annual Focus Users’ Conference Import Testing Data Presented by: Adrian Ruiz Presented by: Adrian Ruiz.
ResponseCard XR User Data. Press the MENU button ResponseCard XR.
ResponseCard XR User Data Version 1.0 ®. Press the MENU button. ResponseCard XR.
Training Presentation
Fall 2003Sylnovie Merchant, Ph.D. ACCESS Tutorial Note: The purpose of this tutorial is to provide an introduction to some of the functions of ACCESS in.
Features and Specs 512 Channels 32 Groups of 16 Channels High/Low Power 5 Watts High 2 Watts Low Multi-line Alphanumeric Display 3 year warranty.
Entering your user ID into the NXT Clicker *Your User ID is your Netpass username.
WinMax Tool & Material Library Overview Mike Cope August 2007 Updated November 2007 by Robert Gorgol 1.
Online Catalog Tutorial. Introduction Welcome to the Online Catalog Tutorial. This is the place to find answers to all of your online shopping questions.
STEP BY STEP INSTALLATION By Eng. BASSEM ALSAID. Step 1: Boot from windows server 2008 installation DVD, windows will load needed files for starting installation.
PestPac Software. Leads The Leads Module allows you to track all of your pending sales for your company from the first contact to the close. By the end.
EPOCH 1000 Series Procedure Phased Array DAC/TVG.
Installation and Operation for the EPOCH 600
Tunner / Halvorsen Parts Order Guide
Course Topics Course Topics ECARS Enhancements
Pico Pico LAB#1 Starting & Stopping Motors.
Setup Guide - DeviceNet Communication AC1314 with RSNetworx
The intended use and features of Room Four Database
Microsoft Access Validation Rules, Table Relationships And
1 Word Processing Part I.
Tutorial 12 Managing and Securing a Database
Presentation transcript:

EPOCH 1000 Series Procedure Custom PA Probe-Wedge Definition

Custom Phased Array Probe/Wedge Definitions The EPOCH 1000i comes loaded with preset phased array probe and wedge definitions for the most common probes and wedges used with this instrument. These include the A10P, AWS1, and DGS1 series probes and associated wedges. The EPOCH 1000i can be used with other phased array probes and wedges. This requires that the user input a custom set up of the probe and/or wedge characteristics into the probe database onboard the instrument prior to use. This simple procedure allows compatibility with existing probes in the market that are not listed in the standard database.

Custom Probe-Wedge Definition u To begin defining a custom probe or wedge, use the PA Probe group menu and select P2 (EDIT) u Use the down arrow to select either Probe ID or Wedge ID to define a new probe or wedge u NOTE: The EPOCH 1000i features automatic probe parameter recognition for all Olympus NDT OmniScan compatible probes by reading this probe data from the information stored in the probe connector. In most cases, the user will not need to define a custom Probe. It is always recommended that the user verify the information read from the probe.

Custom Wedge Add and Naming u After verifying the probe information is correct, use the down arrow to highlight Wedge ID u Press P1 (Add) to add a new wedge to the instrument’s probe-wedge database u Enter the wedge ID name using the adjustment knob (to select characters) and the F1 key (to accept the highlighted character) u Once the wedge ID name is enter properly, press the CHECK key to accept the name Note: If a wedge or probe is entered incorrectly, highlight the Probe ID or Wedge ID and press P7 (Delete) to remove it from the database.

Custom Wedge Parameter Adjustment u Once the proper wedge name is entered, use the down arrow to highlight each wedge characteristic and adjust to the proper value –Note: To adjust values, use the adjustment knob or left/right arrow keys. Values can be adjusted in coarse or fine increments by pressing the Check key u The wedge is now stored in the instrument probe-wedge database u To use this probe and wedge combination, enter the Beam setup menu, select the new wedge ID from the wedge ID list, and continue normal beam setup and calibration procedures

Custom Probe and Wedge Linking u To enhance usability, the EPOCH 1000i allows the user to link a custom probe and wedge together. This means that when the custom PA probe is attached to the instrument and the user enters the BEAM setup menu, only the linked custom wedge will be available in the Wedge ID list. –This expedites selection of the wedge by not requiring the user to scroll through every available wedge. u In the Edit menu, press P1 (Link) to open the link menu u Use the down arrow to highlight the desired probe u Use the right arrow to enter the Wedge ID list u Use the CHECK key to highlight each wedge to associate with the highlighted probe u Press ESC to complete and exit

Custom Probe-Wedge Linking (cont.) u In the BEAM setup menu, selecting the defined custom probe now only allows the user to select the linked wedges during setup