Dose Reduction in Interventional Radiology and Cardiology

Slides:



Advertisements
Similar presentations
TRAINING COURSE ON X-RAY FOR GP
Advertisements

Technique Guidance Systems
International Atomic Energy Agency Example of Practice of Radiation Protection L 9.2.
FPS HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENTFPS PUBLIC HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENT Medical Imaging Federal initiative Dr Aldo Perissino.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Calibration of the DAP-meter
RAD309 Patient Dose.
IAEA International Atomic Energy Agency Responsibility for Radiation Safety Day 8 – Lecture 4.
Business: Cell/Text: Presented by: Thomas J. LaRocca, M.S., D.A.B.R. Medical Physicist
International Atomic Energy Agency Angiography Equipment L 4.
CVT 102.  Time  Distance  Shielding.
Establishment of a Training Dosimetry Laboratory in Cairo University Dr. Hassan Fathy for NSPA.
11 April th International High-Energy Physics Technical Safety Forum 1 Radiation Protection and Safety in High-Energy Physics Kenneth R. Kase, Ph.D.
Prelim 11/14/11. 2 nd Semester, 3 rd Year Level  The Early 1900’s, With The Work Of An Industrial Engineer Named Frederick Winslow Taylor.  “Father.
Radiation Safety Training for Industrial Radiography IAEA Technical Meeting Vienna, June 2014 Richard van Sonsbeek
Occupational exposure and protective devices
Standards and Guidance
ICRP Publication 117 Authors on behalf of ICRP M.M. Rehani, O. Ciraj-Bjelac, E. Vano, D.L. Miller, S. Walsh, B.D. Giordano, J. Persliden.
PART IX: EMERGENCY EXPOSURE SITUATIONS Module IX.1: Generic requirements for emergency exposure situations Lesson IX.1-2: General Requirements Lecture.
Talking about Radiation Dose
Personal Radiation and Occupational Safety – CT Policy This policy is in both paper form in the lab’s compliance manual, and on a Power Point presentation.
Radiation Protection - Eyes 4 Imaging Solutions, LLC Mark Struthers BBA, BSRT (R)(MR), CMRT, CIIP.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Radiation Protection in Paediatric Radiology
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
Radiation Protection of Patients Unit
Standards and Guidance
Radiation Protection in Paediatric Radiology
International Atomic Energy Agency Can cardiac procedures be graded in complexity and related with dose? L 8.3.
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
CT physics and instrumentation
MEASURING PEAK SKIN DOSE John H. O’Connell Adela Salame-Alfie, Ph.D. NYSDOH David F. Lewis, Ph.D. Poppy Pattanayak International Specialty Products.
BEIR VII Implications of the Report for the Future of Medical Imaging G. Donald Frey, Ph.D. Department of Radiology Medical University of South Carolina.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
Prime Responsibility for Radiation Safety
Dose Audit in Fluoroscopy Colin Martin and David Sutton.
IAEA Feedback – day 3 Thanks again for the many positive comments Again country presentations were appreciated And now a few specifics:
Radiation Sources in medicine diagnostic Radiology
IAEA International Atomic Energy Agency Regulations Part III: Radiation Protection Performance Requirements Day 8 – Lecture 5(3)
Energy Georgi Simeonov European Commission DG ENER, Radiation Protection Unit (D3) Justificação e Optimização das Exposições Médicas a Radiações Ionizantes.
Diagnostic reference levels in Medical Imaging. Concept and practice
Radiation Sources in medicine diagnostic Radiology
Cumulative dose and skin damage
VIII.3. Optimization of Protection for Medical Exposures in Nuclear Medicine. 4. Guidance levels Postgraduate Educational Course in Radiation Protection.
International Atomic Energy Agency Medical exposure in radiology: Scope and responsibilities Module VIII.1 - Part 2 : Training.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Technical Services.
Examples of Good & Bad Practice: Effect of the wedge filter and field size in the skin dose distribution L 9.1.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY L13: Occupational Radiation Protection IAEA Training.
Doses in Fluoroscopy factors influencing patient doses Colin Martin and David Sutton.
Radiation Safety Regulations
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
IAEA International Atomic Energy Agency Radiation protection of the public IAEA Regional Training Course on Radiation Protection of patients for Radiographers,
فرهاد نعلینی. رادیولوژیست. دانشگاه علوم پزشکی کرمانشاه.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Need for a Regulatory program.
ICRP Publication 120 ICRP, Radiological Protection in Cardiology. ICRP Publication 120. Ann. ICRP 42 (1): Authors on behalf of ICRP C. Cousins,
Skin doses in cardiac intervention at St. Olav`s hospital Norway
Christian Lefuare John Croft CEPN NRPB
CURRENT TRENDS AND LIMITATIONS IN ESTABLISHING DIAGNOSTIC REFERENCE LEVELS FOR RADIOLOGICAL EXAMINATIONS IN NIGERIA The 48th Annual Conference and.
Optimisation of Patient Protection for Radiography
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
David Sutton or Colin Martin But Borrowed from Jerry Williams
PRACTICAL APPLICATION OF Diagnostic Reference Levels
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Diagnostic Reference Levels (DRLs) in Medical Imaging
REGULATORY IMPLICATIONS OF THE NEW DOSE LIMIT FOR LENS OF THE EYE
Fig 1. Proposed Diagnostic Reference Levels for 3  Common Cardiac Interventional Procedures: an all-Ireland Investigation  Collaborative project between.
Presentation transcript:

Dose Reduction in Interventional Radiology and Cardiology Renato Padovani ICTP, Trieste, Italy

The fact Interventional radiology & cardiology are hospital fluoroscopy guided practices with the highest radiological workload Annual workload of fluoroscopy guided practices R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Instruments to monitor exposures and practices Dose indexes: Patient doses (KAP, CK, PSK, …) related to: procedure and, complexity Staff doses (effective dose, over/under apron dose, hand/eye dose) related to: Operator task No. procedure and type and complexity Procedure protocols Audits R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Variability in patient doses R. Padovani, Dose Management in Interventional Radiology Variability in patient doses PTCA survey in a sample of European hospitals: FT: median values in a range from 5 to 13 (factor 2.5) KAP: median values in a range from 35 to 85 (factor 2.5) Great variability of KAP values, not correlated with procedure complexity (fluoroscopy time) SENTINEL project survey (2007) IAEA Training Course, March 2009, Udine (Italy)

Variability in staff doses 20 hospitals in 15 countries: annual doses and individual workload (2010) Interventional Cardiologists: Over apron and effective dose versus no. of IC procedures performed in a year (triangle: staff in training) Great variability, high doses and number of unrealistic zero values ISEMIR (IAEA) project survey (2011) R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Optimisation of radiation protection in interventional radiology From 1975, new technologies and materials for interventional devices have been developed enabling new and complex procedures High doses can be delivered with reported: skin injuries to patients eye lens opacities of operators Optimisation of IR practices are mandatory to reduce un-necessary exposures. Four central issues have been identified: Equipment Quality management Operator training Occupational radiation protection D.L. Miller, Efforts to optimize radiation protection in interventional fluoroscopy. Health Phys, 2013 Nov; 105(5):435-44 R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Equipment for IR: example of setups and performances R. Padovani, Dose Management in Interventional Radiology Equipment for IR: example of setups and performances Entrance surface air kerma rate In image acquisition (cine) modes Entrance surface air kerma rate In fluoroscopy modes - fluoro low: up to 25 mGy/min (ratio max/min 7) fluoro medium: up to 50 mGy/min (max/min 5) fluoro high: up to 80 mGy/min (max/min 7) Large variability in equipment set-up and performances: - cine low: ratio max/min 4 cine normal : ratio max/min 4 SENTINEL project survey (2007) 7 IAEA Training Course, March 2009, Udine (Italy)

Equipment set up ICRP 120 (223) .... With digital imaging detectors, it is possible to select a wide range of dose values to obtain the required level of quality in the images. Cardiologists, radiographers, the medical physicist and the industry engineer should set the fluoroscopic system doses to achieve the appropriate balance between image quality and dose. R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Example of reference levels for angiography equipment dose rates SENTINEL proposed reference levels for entrance air kerma rates for cardiac interventional procedures Recommendations to set-up equipment dose rates for the different clinical tasks are necessary SENTINEL project survey (2007)

Quality management: assess and use of DRLs in IR R. Padovani, Dose Management in Interventional Radiology Quality management: assess and use of DRLs in IR The concept of diagnostic reference level (DRL) refers to “common examinations” done in a relatively standardized manner. Extending this concept to fluoroscopically guided interventions raises several problems: In addition to technical variables procedures are usually non-standard for clinical reasons The complexity of a procedure is affected by the patient’s anatomy and to the severity of the treated pathology. Dose Management in Interventional Radiology IAEA Training Course, March 2009, Udine (Italy)

Example of DRLs for IC DIMOND and SENTINEL projects proposed reference levels for dose rates for cardiac procedures Other studies have been then undertaken to assess DRLs in cardiac procedures with values in a range of a factor not more than 2 DIMOND & SENTINEL projects survey (2003 & 2007)

DRLs for Interventional Radiology Type of examination Reference levels Fluoroscopy time (min) Number of images KAP (Gy cm2) Transjugular intrahepatic portosystemic shunt creation 60 300 525 Biliary drainage 30 20 100 Nephrostomy for obstruction 15 12 40 Nephrostomy for stone access 25 14 Pulmonary angiography 10 215 110 Inferior vena cava filter placement 4 Renal or visceral angioplasty without stent 210 200 Renal or visceral angioplasty with stent 250 Iliac angioplasty without stent Iliac angioplasty with stent 350 Bronchial artery embolisation 50 450 240 Hepatic chemoembolisation 400 Uterine fibroid embolisation 36 Other tumor embolisation 35 325 390 Gastrointestinal hemorrhage localization and treatment 425 520 Embolisation in the head for AVM 135 1,500 550 Embolisation in the head for aneurysm 90 1,350 360 Embolisation in the head for tumor 1,700 Vertebroplasty 21 120 Pelvic artery embolisation for trauma or tumor Embolisation in the spine for AVM or tumor 130 950 DL. Miller, D. Kwon, GH. Bonavia. Reference levels for patient radiation doses in interventional radiology – Proposed initial values for US practice. Radiology, 253: 3, 2009. R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

… on DRLs in IR There is today a general consensus that DRLs : can be assessed and used in IR should be proposed as a set of parameters: fluoroscopy time, no. images, KAP and CK at IRP can allow to identify non acceptable practices and to initiate an optimisation process How to manage the complexity of procedures? How to manage the high skin doses delivered in non-optimised, high dose and/or repeated procedures? R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

DRLs vs complexity of PTCA procedures R. Padovani, Dose Management in Interventional Radiology DRLs vs complexity of PTCA procedures IAEA study (2006) More 1000 PTCA procedures analysed Anathomical and pathology determinants for complexity of procedures identified Reference levels assessed as a function of complexity Anatomical and pathology data can be difficult to collect in the large sample of procedures necessary to identify complexity factors Dose Management in Interventional Radiology IAEA Training Course, March 2009, Udine (Italy)

Complexity of IR procedures An alternative method not requiring complexity information (NCRP 110): To collect dose data from every cases for a number of facilities to compensate for the large variability in patient doses (ADS, Advisory Data Set) This data set is compared with the Facility Data Set (FDS): Median (not mean) FDS is compared with DRL Also, the two distributions are compared Analysis should be performed in the presence of important differences between the distributions (for high and low doses) R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Complexity of IR procedures Recommended investigations: Low doses: if the FDS median is below the 10th percentile (IAEA, 2009) or the 25th percentile (NCRP, 2010) of the ADS. Low radiation usage might be attributable to inadequate image quality, mix of low clinical complexity, or superior dose management. High doses: presence of a higher percentage of high doses compared to the ADS High doses might be attributable to a too high image quality, mix of high clinical complexity, or poor dose management R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Management of tissue effects (skin burns) NCRP 168 defines a potentially high-dose procedure as one where more than 5 % of cases result in CK exceeding 3 Gy or KAP exceeding 300 Gycm2 The trigger level (TL) is proposed as a dose level aiming to alert the interventionalist when skin dose can be comparable to a threshold for tissue effects. Trigger levels are usually expressed in term of CK (or KAP), when its relationship with the peak skin dose has been assessed. When skin dose maps are available on modern equipment, TL can be expressed in term of peak skin dose (PSD) Clinical follow-up is recommended for patients exceeding TL R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Quality management When dose reports from the angiographic equipment (private or DICOM RDSR) and dose archives are available, more detailed analysis are possible and easier to perform like: Cumulative patient dose assessment Repeated procedures Peak skin dose assessment To address clinical follow-up Procedure protocol Operator behaviour R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Example of operator’s behavior 3 interventionalists are working in the same hospital with the same equipment on a similar mix of procedures average KAP for fluoro and cine modes IC-A/IC-B = 3 R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Quality management: dose tracking tools These necessary analysis require an easy collection of procedure parameters and dose data IEC, DICOM and IHE have developed standards supporting these needs (with AAPM and EFOMP) … today, patient dose tracking tools are becoming available representing an important step in the quality management of the IR practice Reports should be easy to read for all the IR staff, they should not be a MP tool ! REGISTRATION DISTRIBUTION ARCHIVE IHE Radiation Exposure Monitoring Profile (REM) R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Occupational radiation protection 20 hospitals in 15 countries: annual doses and individual workload (2010) Interventional Cardiologists: Over apron and effective dose versus no. of IC procedures performed in a year (triangle: staff in training) Great variability, high doses and number of unrealistic zero values. Do we know actual staff exposures in IR ? ISEMIR (IAEA) project survey (2011) R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Occupational radiation protection The present poor situation of staff monitoring, mainly in IC, is quite unexpected ... after 50 years of regulations, dosimetry techniques developments, personal monitoring experience and training R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Personal monitoring habits Interventional cardiologists: 76% claimed that they always used their dosimeter 45% stated they always used 2 dosimeters 50% in Healthcare Level I countries 24% in other countries Results from the survey probably give an over-optimistic picture R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Results from the survey probably give an over-optimistic picture Knowledge of doses Interventional cardiologists: 64% said they knew their own personal doses 38% knew both their own and patients’ doses Results from the survey probably give an over-optimistic picture R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Regulatory requirements for monitoring in IC ~ 60% of RBs stated that they specify the number and position of dosimeters 20% specify 2 dosimeters 1 above and 1 below the apron 40% specify 1 dosimeter Most (~ 80%) above the apron R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Eye lens exposure of ICs Over apron Hp(0.07) is frequently used to estimate eye lens doses Sample of “good” quality data are showing a great fraction of ICs are receiving doses over the recently ICRP recommended limit. First operator: mean value 50 µSv/procedure R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

... summarising Staff exposure of IC staff: Lack of knowledge of actual doses Large variability of doses Great number of unrealistic zero dose values Individual high dose values are indicating existence of high exposures in IC practice Probably, a large fraction of interventionalists have annual eye doses well over 20 mSv/y R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Eye lens dose assessment in IR New dosimetry challenges are posed by the 2011 ICRP recommendation Several factors are influencing eye dose: use of eye shields (suspended lead screen, lead glasses) position of the operator X-ray projection dosimeter position: Above the eye on the side of the x-ray tube Alternative: dosimeter at the neck over the apron  Uncertainty in dose assessment can be very high Brow (fronte) R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

Optimisation in IR: staff exposure The need: To improve staff monitoring: Dosimetry: models to assess eye doses, computational dosimetry Technologies: active dosimeters, electronic archives providing real time information, integration of staff and patient exposures To improve dosimetry practices Inspection/audit to integrate national dose archives with personal data (e.g. clinical tasks & workload)

Reduce patient/staff exposure: training Training in RP should become an essential part of the IR process The training should be theoretical and practical with: a curriculum appropriate to the practice a certification, or formal qualification MEDRAPET (2011) (2014) R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

EU BSS (2013) Formal recognition of E&T in RP is required by new BSS Art.18 - Education, information and training in the field of medical exposure Member States shall ensure that practitioners and the individuals involved in the practical aspects of medical radiological procedures have adequate education, information and theoretical and practical training ... in radiation protection. ... Member States shall ensure that appropriate curricula are established and shall recognise the corresponding diplomas, certificates or formal qualifications. R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology

… training in IR for medical physicists High dose X-ray procedures in Interventional Radiology and Cardiology: establishment of a robust quality assurance programme for patients and staff Udine (Italy) 13–18 February 2016 Module leaders: E. Vano, A. Trianni www.eutempe-rx.eu R.Padovani _ Dose Reduction in Interventional Radiology & Cardiology