Reliability of Aberrometry Versus Cycloplegic Retinoscopy in Prescribing Glasses to Undilated Child S.A. Erzurum, MD FACS Aylin Sarac.

Slides:



Advertisements
Similar presentations
To empower volunteers to serve their communities, meet humanitarian needs, encourage peace and promote international understanding through Lions clubs.
Advertisements

Comparison of Visual Outcomes With Toric IOL and With Limbal Relaxing Incisions in Cataract Surgery Eriko Fukuyama, MD Fukuyama Eye Clinic Fukuoka, Japan.
PRACTICE OF REFRACTION
Presented by: Ray T. Oyakawa, M.D. Sharper Vision Centers A MEDICAL GROUP Comparison of PalmScan and IOL Master axial lengths measurements No financial.
Pooja B. Jamnadas, MD, Peter Russo, OD, William Bonk, Shuchi Patel, MD Loyola University Chicago, Stritch School of Medicine, Department of Ophthalmology,
Inherited eye conditions. Some eye problems can run in the family Refractive error –Myopia –Hyperopia –Astigmatism Strabismus Retinitis pigmentosa Colour.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Correlation Of Corneal Contour With Higher Order Ocular Aberrations (HOA) In Indian Eyes Manish Chaudhary MS Amit Gupta MS Advanced Eye Centre, Postgraduate.
Refractive Effects of Lamellar Keratectomy/Debridement for Corneal Surface Disorders Pre-Cataract Surgery Haresh Ailani MD, 1 Ira J. Udell MD, 1 Jules.
Clinical Refraction Procedure Presented by T.Muthuramalingam.
Eyes and Vision [Name of Presenter] Doctor of Optometry.
Is it a Learning Disability or Vision Problem? The Eye M.D.’s role in screening and treating children to support school and life success Joint Policy Statement.
Vision-Related Quality of Life Assessment using NEI-VFQ-25 in Children With History of Phakic or Aphakic IOL Refractive Surgery. Claire Hartnett MD Michael.
To empower volunteers to serve their communities, meet humanitarian needs, encourage peace and promote international understanding through Lions clubs.
Driving and vision. The importance of good vision for driving can not be overemphasised.
CASE DISCUSSION and Prescribing aspects Anshika Shah TS012 1.
PRCTICAL DIFFICULTIES OF PROGRESSIVE LENS FITTING
Introducing InfantSEE ® A Public Health Program for America’s Youngest Patients.
Understanding Amblyopia
Better Health. No Hassles. [Name of Presenter] Children’s Eyes and Vision.
Healthy Eyes Healthy People: Making Vision a Health Priority Vision in Children and Adolescents.
Medical Director - R & D Consultant, Ziemer Group AG, Port, Switzerland Speaker, Bausch & Lomb do Brasil Territory Manager.
Hong Kong Eye Hospital Biometry Audit 2012 SN60WF IOL Dr. Rose Chan
1 Amblyopia and Strabismus For Medical Students & GP Samir Jamal MD, FRCSC KAUH.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
SPED 537 ECSE Methods Multiple Disabilities Chapter 4 March 13-14, 2006 Deborah Chen, Ph.D. CSU, Northridge.
Hong Kong Eye Hospital Biometry Audit 2011 SN60WF IOL Dr. Rose Chan Resident, Hong Kong Eye Hospital.
CHILD HEALTH SURVEILLANCE Vision Screening & Eye Problems Gordon N Dutton Emeritus Professor of Visual Science Paediatric Ophthalmologist.
The authors have no financial interest in the subject matter of this poster Yinfei Xu, Peter S. Hersh, MD, David S. Chu, MD Institutional Affiliations.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Children’s Eyes and Vision [Name of Presenter] Doctor of Optometry.
*0570 Developmental Delay By Tami Jo Redinger. Definition  A student with a severe delay in developmental functions at a developmental level 2 or more.
Rajendra Gyawali Consultant optometrist, Male’ Eye Clinic Maldives
Predicting visual performance from wavefront quality metrics in cataract Konrad Pesudovs Katja Ullrich NH&MRC Centre for Clinical Eye Research, Flinders.
ELEVATION AND PACHYMETRY VALUES IN NORMAL CORNEAS OBTAINED BY GALILEI ASCRS Boston April Vision Sana Research Group Vision Sana Research Group.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
VISION.
Refractive Accuracy of LASIK Using the IntraLase and Zyoptix BACKGROUND Wavefront guided customized lasik procedures are designed to correct both lower.
Analysis of Ocular Wavefront Aberrations in Post Penetrating Keratoplasty Eyes with Two Different Hartmann-Shack Aberrometers Adriana S. Forseto 1, MD;
REFRACTIVE OUTCOMES WITH TORIC ICL IMPLANTS CHIEF AUTHOR: Dr. D.RAMAMURTHY CO – AUTHOR: Dr. R.CHITRA The authors have no financial interest in the subject.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Michael J. Endl, M.D. The author of this poster has no financial interest in the subject matter of this poster. Early Results of Static and Dynamic Iris.
Refractec ViewPoint™ CK System for the Treatment of Spherical Hyperopia Sheryl Berman, MD Medical Officer FDA/CDRH/ODE/DOED.
Adriana S. Forseto1, MD Walton Nosé1,2, MD
Evaluation of Efficacy and Safety of Intracorneal Ring Segment (Intacs SK) in Keratoconus Abdulrahman Al-Muammar, MD, FRCSC I have no financial interest.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
Analyze Effects of Multifocal Intraocular Lenses on Potential Acuity Meter and Perimetry Testing G. Yuricek Aylin Sarac S.A. Erzurum, MD, FACS.
Comparison of Patient Profiles: Wavefront-Guided LASIK Versus Conventional LASIK Michiho Suzuki-Judge, MD Inouye Eye Hospital Tokyo, Japan Michiho Suzuki-Judge,
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Prevalence of corneal astigmatism in cataract surgery candidates in Bangkok, Thailand Kaevalin Lekhanont, MD, Wadakarn Wuthisiri, MD, Porntip Chatchaipun,
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
iTrace Dynamic Laser Refraction: Clinical Application
Strategies for Patching Bill Takeshita, O.D., F.A.A.O., F.C.O.V.D. The Center for the Partially Sighted low-vision.org.
Long Term Results of Femtosecond Laser-Assisted Sutureless Anterior Lamellar Keratoplasty “FALK” Mohamed Abou Shousha, MD, Sonia H. Yoo, MD, William Feuer,
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
9-Month Results after Implantation of a new accommodative IOL that works with one focus Mark Tomalla M.D.* Clinic for Refractive and Ophthalmic Surgery,
Augenabteilung am St. Franziskus Hospital Münster Influence of Mydriatic Eye-drops on Wavefront-sensing and Automated Refraction Taneri S, Oehler S, MacRae.
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Corneal shape and corneal aberrations after MicroIncision Cataract Surgery (MICS) NOCHEZ Y, BUREL B, MAJZOUB S, PISELLA PJ C.H.U.
Pediatric Vision Care Bill Takeshita, O.D.,F.A.A.O., F.C.O.V.D.
Corneal CXL in Pediatric Patients with Progressive Keratoconus Stephanie Wise, Christian Diaz, Karolien Termote, Paul J. Dubord, Martin McCarthy, Sonia.
A useful technique to assess accommodation
Am J Ophthalmol 2009;147:357–363 Ap.신선영/R4 권진우
Introduction to Retinoscopy
The authors have nothing to declare
Comparison of corneal powers obtained from four different devices
Analysis of profile of visual acuity changes following Laser-Assisted Keratomileusis in adult amblyopia Kalyan Das MS, DNB Bobby Sarungbam MBBS Kasturi.
*Center for Excellence in Eyecare
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

Reliability of Aberrometry Versus Cycloplegic Retinoscopy in Prescribing Glasses to Undilated Child S.A. Erzurum, MD FACS Aylin Sarac

Financial Interest The authors have no financial interests in any of the topics discussed in this study.

Purpose of Study Retinoscopy is a difficult skill for many eye care professionals. Children are a difficult subpopulation for eye care professional to refract. Inaccurate glass prescribing occurs for many children. Dilation necessary for accurate refraction but disliked by children and family.

Purpose of Study Find a reliable method for non-specialized eye care providers to prescribe glasses for children. Reliable method should be easy and quick. Find method that eliminates/reduces need for dilating drops to check refraction.

Method iZON Aberrometer was machine used for comparison to cycloplegic refraction. Images are taken before dilation. Child sits upon parent’s lap and multiple rapid images are obtained. Immediately upon taking image, analysis is provided of sphere, cylinder, axis, level of aberrations, and quality of image.

Example of reliable image capture. Prescription measured and reported as sphere, cylinder, and axis. Aberrations measured and reported in green, yellow or red. Pictures demonstrate how patient sees at night.

Example of poor image and unreliable readings. No measurements are provided for aberrations. Whatever prescription was captured is reported, but may not be reliable.

Example of right eye with poor image capture and left eye with excellent capture. Right eye results for refraction may not be reliable. Left eye results reliable.

Method Prospective consecutive series of 256 eyes in 128 pediatric patients involved in full exam. Age range of 3 to 18 years. iZON aberrometer images prior to dilation. Full eye exam with cycloplegic refraction. No patients were excluded, and all were examined by the same pediatric ophthalmologist.

Results CYCLOPLEGIC ABERROMETER (mean +/- SD)(mean +/- SD) Sphere Astigmatism Spheric equiv Age (mean + SD) years; Mode 7 years Range 3-18 years Female6248.4% Male6651.6%

Prevalence of Eye Disorders in Study Patients Prevalence of Eye Disorders – Normal – Esotropia – Amblyopia – Exotropia9 3.5 – Cerebral palsy/ developmental delay – Congenital nystagmus – Cataracts3 1.2 – IDDM4 1.6 – Duane’s3 1.2 – Best’s1 0.4 – Coloboma1 0.4

Reliability of Aberrometer Only 45 eyes of 256 (17%)had an unreliable reading and were excluded from comparison. 26 eyes of these 45 (64%)had ocular pathology which would have directed them to sub-specialized care. Immediately upon taking image, examiner is aware of reliability of image.

Results of Comparison between two Methods Comparison between aberrometer and cycloplegic results were made in each area of sphere, cylinder, and axis. In all categories, correlation was high between the two methods. Offset and slope of the best fit regression were calculated for each. All comparisons showed the slope was very close to 1.

Y cyclo sphere = 1.04 X izon sphere Model ANOVA F = , p < R = 0.934

Y cyclo SPHEQ = X izon SPHEQ Model ANOVA F = p < R = 0.865

Y cyclo astig = X izon astig – Model ANOVA F = p < R = 0.887

SphereSpherical Equivalent Astigmatism

Conclusions iZON aberrometer is a reliable method of refraction to assist practitioners uncomfortable with cycloplegic refraction in children. iZON aberrometer gives a reliable reading and a high correlation with cycloplegic refraction. Group of patients who showed higher unreliability by aberrometry measurements had a higher chance of ocular pathology.