The Buildings Envelope.  R Values are the thermal resistance of a building product. R values are given to certain materials to evaluate there ability.

Slides:



Advertisements
Similar presentations
Temperature and Heat Loss The following topics are covered in this presentation: Calculation of U-values Heat loss from the building envelope Use of U-values.
Advertisements

Environmental Controls I/IG
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2J: Building.
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
Walls of Structure Decreasing the Amount of Heat Exchange.
Building Envelope. Energy Conservation House design and orientation Lifestyle changes Energy efficiency.
Heating Systems Forced Air Systems.
Application of Steady-State Heat Transfer
Insulation.
Heat Transfer Chapter 2.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
Agricultural Structures: Insulation and Heat Flow
Conduction Cooling Loads
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Heat Loss HVAC CNST 305 Environmental Systems 1 Dr. Berryman.
Furnace Efficiency Bryce Cox Dallin Bullock. Problem My gas bill is very expensive My furnace claims an efficiency of 78% but it appears to be less efficient.
Greenhouse Heating Requirements Greenhouse Management.
Temperature and Heat Loss The following topics are covered in this presentation: Temperature and temperature scales Transfer of heat Thermal conductivity,
Walls. Apply knowledge of thermal mass and insulation with passive design strategies to reduce the energy needed by active systems.
Heat Loss and Gain Heat Loss and Gain
Introduction to Thermodynamics
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
PASSIVE SOLAR DESIGN. Design Techniques
Introduction to Thermodynamics
Chapter 18. Heat Transfer A PowerPoint Presentation by
Introduction to Thermodynamics
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Chapter 4: Introduction to thermal control As we take on issues of thermal control it is important to keep in mind the following issues: 1.Human comfort.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Climate and Architecture Dr. Abdelrahman Elbakheit
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
By: Matthew Irvine and Cristina Belew. Origination and Goals  Partnership with Habitat for Humanity  Their goal is to lower the overall cost to owner.
Remember... Resistance in Mechanical systems (friction) opposes motion of solid objects.
Science Project Advice on how to reduce energy losses.
Air Leakage and Water Vapor Control Chapter 6. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
Radiators. BTU : British Thermal Unit BTU/h : British Thermal Units per hour.
Fourier's law of heat conduction
Conservation of Building Energy 3A9 Construction Technology Dr S Pavía Dept of Civil Engineering Trinity College Dublin.
Chapter 3.4 Notes Thermal Rates.  The amount of heat that is transferred per unit time is the heat flow rate  Equation for heat flow rate = heat / time.
Heat loss, U-values and all that stuff. First a bit of Science First Law of Thermodynamics You can’t get more heat out of a closed system than you put.
GCSE ENERGY; THERMAL ENERGY TRANSFER 2
Common Components of a Traditional Wood Framed Building
Technology in Architecture
Heat Loss and Gain Civil Engineering and Architecture
Wood Frame Systems Civil Engineering and Architecture®
THERMAL LOADING OF BUILDINGS
Maria’s Restaurant Chapter 1 Section 3
Chapter 18. Heat Transfer A PowerPoint Presentation by
RESIDENTIAL HVAC (HEAT LOSS & GAIN)
Heat gain and heat loss in buildings
Heat Loss and Gain.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Conduction Cooling Loads
Chapter 2C: BASIC THERMAL SCIENCES: RADIATION HEAT TRANSFER
Common Components of a Traditional Wood Framed Building
Temperature and Heat Loss
Lesson 12 CONDUCTION HEAT TRANSFER
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Common Components of a Traditional Wood Framed Building
Chapter 18. Heat Transfer A PowerPoint Presentation by
Heat Loss and Gain Civil Engineering and Architecture
Common Components of a Traditional Wood Framed Building
Heat Loss and Gain Heat Loss and Gain
Maria’s Restaurant Chapter 1 Section 3
HEAT EXCHANGE IN BUILDINGS. TERMINOLOGIES Thermal conductivity: is the rate of heat flow through a unit area of unit thickness of the material for a unit.
Chapter 2C: BASIC THERMAL SCIENCES: RADIATION HEAT TRANSFER
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

The Buildings Envelope

 R Values are the thermal resistance of a building product. R values are given to certain materials to evaluate there ability to resist the flow of heat or cold. R factors can be added to find an assemblies overall thermal resistance.

The Buildings Envelope R factors can be added One more time R factors can be added

The Buildings Envelope  A U factor is a thermal coefficient and is the reciprocal of an R factor. U = 1 / R U values are given to certain materials to evaluate there ability to resist the flow of heat or cold. U factors can not be added.

The Buildings Envelope U factors can not be added One more time U factors can not be added

The Buildings Envelope  U – Coefficient is defined as the number of Btuh that pass through 1 square foot of wall, floor roof and etc. under actual conditions when the actual conditions at the inside and out side air temperature is 1 degree F under a steady state of heat flow. 1 / R =U

The Buildings Envelope  Q = A*U*TD (Q = heat gain, A = area of building component, TD = temperature difference).  Q = BTU h  We’ll be using this formula very soon!

The Buildings Envelope  A typical U value for a ceiling component with a total thermal resistance of R-30 would be calculated as follow: U=1/30, or U=.033. This U value is then used to calculate the heat flow through the ceiling component using the heat transfer formula: Q = A*U*TD (Q = heat gain, A = area of building component, TD = temperature difference).

The Buildings Envelope Q = A*U*TD (Q = heat gain, A = area of building component, TD = temperature difference). Example: calculate the total heat gain through a 10 x 10 bedroom ceiling with a thermal resistance of R-30 and the temperature difference of 55 degrees between the interior conditioned zone (75 degrees) and the vented attic (130 degrees). Formula used is Q = A*U*TD, total heat gain through the ceiling is Q = 100*.033*55, Q = BTUH (British Thermal Units per Hour).

The Buildings Envelope  k Values are the thermal conductivity of a building product. k values are given to certain materials to evaluate there ability to resist the flow of heat or cold per inch.

The Buildings Envelope k values is the Heat flow through homogeneous solids. Conductivity or conductance is designated as k values and is defined as the number of Btuh that flow through one square foot of material one inch thick when the temperature drops through the material under conditions of steady heat flow.

The Buildings Envelope  k Values can be calculated by dividing the thickness of a particular material in inches (or meters) by the K value. (’R’ = d / K)  This slide is impressing your date only.  In physics, thermal conductivity, k, is the property of a material that indicates its ability to conduct heat. It appears primarily in Fourier's Law for heat conductionphysics propertyheat Fourier's Lawheat conduction

The Buildings Envelope  C values C values is referred to as a basic rating for material and is referred to as conductivity of homogeneous material for thickness other than one inch. All other conditions remain the same.

The Buildings Envelope  a = Air-Space Conductance and is effected by the position and by the emissivity of E of the surfaces.

The Buildings Envelope  f = Film or Surface Conductance Coefficient. This is the rate of heat flow in Btuh through 1 square foot of surface due to the motion of air against the surface, for 1 degree difference in temperature.

The Buildings Envelope

 5/8 GWB  V.B. 4 mil poly  2x6 studs  R-19 Batt Insulation  Weather Barrier (Tyvek)  5/8 Exterior GWB  4 Brick  Air Space  Inside Air Film  Outside Air Space

The Buildings Envelope  Wall Cavity R value 5/8 GWB.56 (textbook pp 33) V.B. 4 mil poly (Negligible) 2x6 studsCavity (not needed) R-19 Batt Insulation19.00 Weather Barrier (Tyvek) (Negligible) 5/8 Exterior GWB.56 (textbook pp 33) 4 Brick 1.11 (Handout) Air Space 1.18 (table 2-4 pp 34) Inside Air Film *.68 (table 2-5 pp 34) Outside Air Space **.17 (table 2-5 pp 34) Total * Still air - Vertical ** 15 mph winter

The Buildings Envelope  At the Studs R value 5/8 GWB.56 (textbook pp 33) V.B. 4 mil poly (Negligible) 2x6 studs *** 5.6 R-19 Batt Insulation At Studs Weather Barrier (Tyvek) (Negligible) 5/8 Exterior GWB.56 (textbook pp 33) 4 Brick 1.11 (Handout) Air Space 1.18 (table 2-4 pp 34) Inside Air Film.68 (table 2-5 pp 34) Outside Air Space.17 (table 2-5 pp 34) Total 9.86 *** Handout – Softwood – Douglas fir = 1/k = aver. = x 5.5”= 5.6

The Buildings Envelope  Using the formula Q = A*U*TD R value for Cavity is U = 1/R = 1/23.26 =.043 R value for Studs is 9.86 U = 1/R = 1/9.86 =.10 The wall is 10’-0” high and 30’-0” long 10 x 30 = 300 square feet Studs 16” on center ( 30’-0” / (16”) = 23 studs + 1 = 24 studs) 24 studs x (.125 (1- ½”) x 10’) = 30 square feet

The Buildings Envelope  Using the formula Q = A*U*TD TD Temperature Deference – Spokane -15 degrees Winter 68 degrees indoor Difference = 83 degrees

The Buildings Envelope  Using the formula Q = A*U*TD Cavity 1,071 Btuh = 300 x.043 x 83 Studs 249 Btuh = 30 x.10 x 83

The Buildings Envelope  Using the formula Q = A*U*TD However we need to remove the studs. 300 – 30 = 270 sf Ratio is 30 / 300 =.10 or 10% studs to cavity

The Buildings Envelope  Windows or Fenestration Q = A*U*TD 4 x 6 window = 24 sf double glazed window = 2.08 R factor or.481 U factor

The Buildings Envelope  Using the formula 958 = 24*.481* 83

The Buildings Envelope  Using the formula Q = A*U*TD Cavity 878 Btuh = 246 x.043 x 83 Studs 249 Btuh = 30 x.10 x 83 Window 958 Btuh = 24 x.481 x 83

The Buildings Envelope  Using the formula Q = A*U*TD Cavity 878 Btuh = 246 x.043 x 83 Studs 249 Btuh = 30 x.10 x 83 Window 958 Btuh = 24 x.481 x 83

The Buildings Envelope  Amount of KW = (BTUh x Annual Degree Days) / (diff in T x 3,413 BTUh x 100%)  For electrical systems  Annual degree days in Spokane is 6655 Heating days x 24 hrs per day

That’s Real Big!