Abstract A fiber optic, photodiode design for detecting horizontal eye movement in the rhesus macaque monkey while in the fMRI is developed and tested.

Slides:



Advertisements
Similar presentations
Optics, Eugene Hecht, Chpt. 8
Advertisements

Introduction to Eye Tracking
Chapter 4: Local integration 2: Neural correlates of the BOLD signal
FARADAY ROTATION Gennady Voronov In this experiments we experimentally determine the Verdet constant of a glass rod with specification SF-59 to be rad/mT*cm.
Wave Energy Conversion Team: Andrew Cameron Brent MacLean Helen McDonald Steve McDonald Nicholas Smith Supervisors:Dr. Robert Bauer Dr. Larry Hughes Richard.
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
Time Dependence of Liquid Crystal Orientational Memory Effect at a Polymer Surface Frederick Davey, Joel Pendery, Sameh Ferjani Principal Investigator:
EEG Experiment for Extra Credit Sign up on the sheet.
Faraday’s Law  produces an induced current Lenz’s Law: Induced current is in a direction so as to produce a B opposing the change in magnetic flux, 
Volumetric Analysis of Brain Structures Using MR Imaging Lilach Shay, Shira Nehemia Bio-Medical Engineering Dr. Alon Friedman and Dr. Akiva Feintuch Department.
G D Calibration of the LIGO Interferometer Using the Recoil of Photons Justice Bruursema Mentor: Daniel Sigg.
GE Energy Silicon Wafer Measurement System Team 10 Olin Biddy Scott Johnson Chetwyn Jones Rob McCoy Tim Weber.
Results The following results are for a specific DUT device called Single Ring Micro Resonator: Figure 6 – PDL against Wavelength Plot Figure 7 – T max.
Self-Induction Transducers ~ AC Supply v ref Inductance Measuring Circuit x (Measurand) Ferromagnetic Target Object Coil is activated by the supply and.
Foundations of Physics
Methods of Studying the Brain Mrs. Joseph AP Psychology Solon High School.
Inexpensive and Accessible Thermal Imaging for the Detection of Cancer Angela Fan Ben Wang Mark Bucklin Nancy Diao Olufunke Laseinde.
IMAGING THE MIND Direct methods –Electrical activity (EEG, MEG) –Metabolic activity (EROS) Indirect methods –Changes in regional Cerebral Blood Flow (rCBF)
CUÑADO, Jeaneth T. GEQUINTO, Leah Jane P. MANGARING, Meleria S.
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
MAGNETO-OPTICAL CURRENT TRANSFORMER.
Team Spot A Cooperative Robotics Problem A Robotics Academy Project: Laurel Hesch Emily Mower Addie Sutphen.
Neural mechanisms of Spatial Learning. Spatial Learning Materials covered in previous lectures Historical development –Tolman and cognitive maps the classic.
Brain Research Methods Maddie Coates. Direct Brain Stimulation Direct brain stimulation is when a device is sends a weak electrical current to disrupt.
Welcome to Physics Jeopardy Chapter 18 Final Jeopardy Question Magnetic fields 100 Electro magnetic Induction Motor Transformers
MAGNETO OPTICAL CURRENT TRANSFORMER Presented By: Shivankit Bansal Final Year Electrical Deptt.
Muscle Volume Analysis 3D reconstruction allows for accurate volume calculation Provides methods for monitoring disease progression Measure muscle atrophy.
 An eye tracking system records how the eyes move when a subject is sitting in front of a computer screen.  The human eyes are constantly moving until.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
MOCT(Magneto Optic Current Transduser)
Progress Report: A Wearable TMS System for Ambulatory Use By: Ben Sass Group 19: Beller, Kahan, Sass Client: St. Jude Medical Date 10/25/2014.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Supervisor: Prof K. Abramski States of polarization of chosen fiber elements.
Actuator 2 – Provides rotation about the roll direction. Actuator 1 – Provides rotation about the pitch direction Figure 2: The Linear Actuator model Abstract.
Chapter 8: Perceiving Motion
Unit 3-B (A): Brain Monitoring Tools Mr. McCormick A.P. Psychology.
STRATEGIES OF COGNITIVE NEUROSCIENCE The Coin of the Realm: correlations between psychological and neurophysiological events/structures Establishing two-way.
STEPPER MOTORS Name: Mr.R.Anandaraj Designation: Associate. Professor Department: Electrical and Electronics Engineering Subject code :EC 6252 Year: II.
Cognition, Brain and Consciousness: An Introduction to Cognitive Neuroscience Edited by Bernard J. Baars and Nicole M. Gage 2007 Academic Press Chapter.
Methodology PET and MRI scanning How do we investigate the brain?
Heather Waldeck Meghan Olson Andrea Zelisko Yao Lu Ben Sprague Missy Haehn Team Members:
1 W. Rooney May 20, 2004 Imaging the Awake Animal MRI Efforts Overview.
Brain Research Methods.
Portable Patient Training Device for Lung Cancer Treatment Thomas Chia Jason Ethington Brent Geiger Kawai Chan Client: Bhudatt Paliwal, PhD Advisor: Willis.
Optical Detection of Micro- Cantilever Deflection Kellen Chase, Richard Colonna, Michael Humphreys, Joseph Ortiz, Grace Shih Dr. Eniko Enikov, AME Dr.
The geometry of the system consisting of the hyperbolic mirror and the CCD camera is shown to the right. The points on the mirror surface can be expressed.
Research Background: Depth Exam Presentation
Measuring Monkey Eye Movement in the MRI Team Members: Josh Anders Betsy Appel Bryan Baxter Alyssa Walsworth Client: Luis Populin,Ph. D. Advisor: Justin.
Physics 2225: Faraday’s Law Purpose Study the induction of electric current according to Faraday’s Law.
Abstract Professor Banks studies the neural pathways of mice in response to audio stimuli and tests their cognition and perception. Since spatial arrangement.
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
Quantification of Sensory Abnormalities Client: Dr. Miroslav Backonja Advisor: Prof. Mitchell Tyler Group Members (in order of appearance): Colleen Farrell.
Abstract Client Expectations References Acknowledgments Richard Bamberg, Dustin Gardner, Matt Kudek, Chelsea Wanta Advisor: Willis Tompkins, Ph.D. Client:
Narnarayan Shastri Institute Of Technology SUBJECT:- AVS FACULTY:- Malhar Chauhan FIELD:- E.C SEM-5 TH TOPIC:- Types Of Microphones Prepared By, PATEL.
HALL EFFECT TRANSDUCERS As already explained in- Art page 562, when a conductor is kept perpendicular to the magnetic field and a direct current.
Final Presentation April 19, 2010 Contactless Angular Position Sensor Team: Eugene Sandberg, Christine Bratton, Matt Landry, Aram Lee, Jeremy Lewis Faculty.
The Antimatter Gravitation Experiment: Early Methods and Data Collection Caleb Tillman Reed College Supervisors: Professor Dan Kaplan, Dr. Alan Hahn.
EKT 451 CHAPTER 6 Sensor & Transducers.
Methods Gary Doran. Subjects Experiment 1: Experiment 2:
20 Overview current  magnetic field magnetic field  current
Chapter 2 E: Brain Monitoring Tools
How can we study the brain?
Self-Contained Endoscopic Video Camera
Intracranial Pressure Monitor
Speed Sensor Calibration
MultiView 400™ Product Presentation Nanonics MultiView 400™
Unit 2 Scanning Techniques
Moo K. Chung1,3, Kim M. Dalton3, Richard J. Davidson2,3
Medical Imaging Imagining Modalities.
Presentation transcript:

Abstract A fiber optic, photodiode design for detecting horizontal eye movement in the rhesus macaque monkey while in the fMRI is developed and tested. Light from an infrared laser source with an output of 40 mW is directed via fiber optic cable to reflect off of the eye. A photodiode receives the reflected light by way of a fiber optic cable and generates a voltage based on the intensity of light received. Maximum reflection achieved was 35%. Output based on a single source cable and single detector cable is not linear.

MotivationMotivation Dr. Populin, a member of the anatomy department at the University of Wisconsin – Madison, wishes to study the neural mechanism behind the spatial visual attention in the cerebral cortex of macaque monkeys through functional magnetic resonance imaging, allowing for analysis of behavioral processes.

Problem Statement The client requests a detection device to measure horizontal monkey eye movement in a functional Magnetic Resonance Imaging (fMRI) environment.

Design Requirements Measure horizontal saccadic eye movement in one eye Measure horizontal saccadic eye movement in one eye Monkey’s view of stimulus projection must not be blocked in both eyes Monkey’s view of stimulus projection must not be blocked in both eyes MRI compatible MRI compatible No ferromagnetic materialNo ferromagnetic material Limited electrical componentsLimited electrical components

Background Eye Movement Eye Movement Smooth pursuit eye movements are made when the eye follows a moving objectSmooth pursuit eye movements are made when the eye follows a moving object Saccadic eye movement consists of rapid jumps in angular direction of eye to redirect line of sight when viewing stationary objectsSaccadic eye movement consists of rapid jumps in angular direction of eye to redirect line of sight when viewing stationary objects Our device will record saccadic eye movementsOur device will record saccadic eye movements (Kowler, 1990)

Background fMRI Coil aligns atomic nuclei with magnetic fieldCoil aligns atomic nuclei with magnetic field As brain activity increases, oxygenated blood flow to active areas increasesAs brain activity increases, oxygenated blood flow to active areas increases Waisman center fMRI has a magnetic strength of 3 TeslaWaisman center fMRI has a magnetic strength of 3 Tesla (Kimmig et al. 1999)

Design #1: Copper Eye Coils Skalar Medical BV.

Analysis of Design #1 Eye Coils Eye Coils Copper wire search coils implanted on the eye generate RF field and induce a current. Current measurement determines eye position.Copper wire search coils implanted on the eye generate RF field and induce a current. Current measurement determines eye position. Advantages: Advantages: Increased accuracy due to placementIncreased accuracy due to placement Established record of successesEstablished record of successes Disadvantages: Disadvantages: Surgical procedure involvedSurgical procedure involved May alter monkey’s natural behaviorsMay alter monkey’s natural behaviors To date, not tested in an fMRI setting due to magnetic constraintsTo date, not tested in an fMRI setting due to magnetic constraints

Design #2: Infrared Camera System Eye camera & IR illuminator Head coil (Adapted from Gitelmen et al ) Infrared camera and IR illuminator Head coil

Analysis of Design #2 Infrared Camera System Infrared Camera System Infrared camera used to capture eye image via infrared light projected by fiber optic cableInfrared camera used to capture eye image via infrared light projected by fiber optic cable Advantages: Advantages: Non-invasiveNon-invasive Devices currently in use in MRI on humansDevices currently in use in MRI on humans Disadvantages: Disadvantages: Camera electronicsCamera electronics Frequent Detection ErrorsFrequent Detection Errors ExpensiveExpensive

Proposed Final Design: Photodiodes System Infrared radiation is projected onto the eye via a fiber optic array attached to an LED source outside of MRI’s Faraday cage Infrared radiation is projected onto the eye via a fiber optic array attached to an LED source outside of MRI’s Faraday cage Two fiber optic cables carry radiation reflected from the eye to photodiodes located outside of Faraday cage Two fiber optic cables carry radiation reflected from the eye to photodiodes located outside of Faraday cage Photodiodes detect incident radiation and produce current based on intensity of light Photodiodes detect incident radiation and produce current based on intensity of light

Proposed Final Design

Analysis of Final Design Advantages: Advantages: Compatible with MRI environmentCompatible with MRI environment Non-invasiveNon-invasive Inexpensive relative to other methodsInexpensive relative to other methods Disadvantages: Disadvantages: Calibration timeCalibration time

Design Comparison Design 1 Eye Coils Design 2 Camera Design 3 Photodiodes Invasiveness054 Expense215 MRI compatibility 135 Responsiveness545 Totals81319 Based on our design matrix, we selected the photodiode system

Materials Used 2 fiber optic cables (50/125 micron) 2 fiber optic cables (50/125 micron) Infrared laser box (output 850nm) Infrared laser box (output 850nm) Power meter (in dB) Power meter (in dB) PVC (3/4 inch, 1 inch) PVC (3/4 inch, 1 inch) Oscilloscope (max voltage = 335 mV) Oscilloscope (max voltage = 335 mV) Sheep eyes, Rabbit eyes, Marble Sheep eyes, Rabbit eyes, Marble

Preliminary Testing: Marble Goal: To obtain infrared reflection off a comparable spherical surface Goal: To obtain infrared reflection off a comparable spherical surface Results: Results: Angle = 96° between cablesAngle = 96° between cables 21.0 dB of reflected IR light21.0 dB of reflected IR light Max output of IR laserMax output of IR laser box is 81.5 dB

Preliminary Testing: Sheep eye Goal: Goal: To obtain realistic reflective properties similar to those of a monkey’s eyeTo obtain realistic reflective properties similar to those of a monkey’s eye Methods: Methods: Used a Sheep eye (2.7 cm in diameter) placed in cupUsed a Sheep eye (2.7 cm in diameter) placed in cup Results: Results: Variation in dB readings with rotation of eyeVariation in dB readings with rotation of eye Unable to accurately measure angle of displacementUnable to accurately measure angle of displacement

Preliminary Testing: Sheep eye Top left: Dissection and preparation of sheep eye Bottom right: Cable arrangement during preliminary sheep eye testing

Testing Set-up Testing set-up consisted of an infrared laser box, two fiber optic cables, and an optical power meter.

Secondary Testing: Sheep Eye Goal: Find a linear relationship between angular eye displacement and voltage Goal: Find a linear relationship between angular eye displacement and voltage Methods: Methods: Used two half-cylinders to determine angular displacementUsed two half-cylinders to determine angular displacement Plotted optical power output vs. angular displacementPlotted optical power output vs. angular displacement

Secondary Testing: Sheep Eye Multiple views of cable and eye orientation for secondary testing with sheep eyes. Double cylinder method allowed for accurate angular displacement measurements vs. optical power output.

Standard Calibration Curve Voltage (in Volts) vs. angular displacement of rhesus monkey eye (in degrees). Calibration curve provided by Luis Populin’s Laboratory

Secondary Testing Results Graphs depict power output (in dB) vs. sheep eye angular displacement (in degrees). Highest power outputs generally found at smaller angles of displacement.

Problems Encountered Maintaining a steady reflection across the surface Maintaining a steady reflection across the surface Accurate angle measurement Accurate angle measurement Keeping the cables fixed in one position Keeping the cables fixed in one position Sheep eyes Sheep eyes PreservationPreservation Shape interfered with angles of reflectionShape interfered with angles of reflection Anatomically different from monkey eyesAnatomically different from monkey eyes Oscilloscope Oscilloscope Obtaining a constant readingObtaining a constant reading

Proposed Budget ComponentPriceSupplier Fiber Optic Cables (FC-FC) $80 Fiberdyne Labs Pigtailed Silicone Photodiodes $25Hamamatsu Fiber optic Array $120Opticis Infrared Light Source $70 Ion Optics Total$295

Future Work Order components and construct functional prototype Order components and construct functional prototype Test system on monkey eyes Test system on monkey eyes Integrate photodiode system with client’s computer software system Integrate photodiode system with client’s computer software system

Acknowledgements and References Applied Science Laboratories (ASL): Buckner, R.L. and Logan J.M Functional Neuroimaging Methods: PET and fMRI. In R. Cabeza and A. Kingstone (eds.) Handbook of Functional Neuroimaging of Cognition. Boston, MA: MIT Press. Bullwinkel, P.E., Fiber optic eye-tracking system utilizing out-of-band light source. US Patent, 6,079,829 Delgado-García, J.M Oculomotor System. Nature: Encyclopedia of Life Sciences. Nature Publishing Group. Gazzaniga, M.S. (ed.) fMRI measurement methods. The New Cognitive Neurosciences. Boston, MA: MIT Press. Gitelman, D.R., Parrish, T.B., LaBar, K.S., Marsel Mesulam, M Rapid Communication: Real-time monitoring of eye movements using infrared video oculography during functional magnetic resonance imaging of the frontal eye fields. NeuroImage. 11: Judge, S.J., Richmond, B.J., Chu, F.C Implantation of magnetic search coils for measurement of eye position: An improved method. Vision Research. 20: Kimmig, H., Greenlee, M.W., Huethe, F., Mergner, T MR-Eyetracker: a new method for eye movement recording in functional magnetic resonance imaging. Exp Brain Res. 126: Kowler, E. (ed.) Eye Movements and Their Role in Visual and Cognitive Processes. Reviews of Oculomotor Research. 4: Reulen, J.P.H., Marcus, J.T., Koop, D., de Vries, F.R., Tiesinga, G., Boshuizen, K., Bos, J.E Med. & Biol. Eng. & Comput. 26: Richards, J.E Eye position prospectus for measuring eye movements. Skalar Medical BV. Special thanks to: Professor Leon McCaughan, ECE Professor Seth McGee, Biocore Lab Manager