Integrated gateway-server for entry-level system monitoring

Slides:



Advertisements
Similar presentations
Entry-level, Ethernet-to-serial-line gateway
Advertisements

Watts up ?. NET. Watts up.NET Overview Ideal for remote monitoring, the built-in web server allows data to be accessed via the internet. Connect the.
DATA ACQUISITION SmartLog X3 DescoEMIT.com Rev:
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
DNR-322L & DNR-326.
DSL-2870B How to Change ADSL Username and Password in your modem router How to Change Wireless Channel in your modem router How to Open Ports in your modem.
Multi Instruments Data Acquisition Software Evolution
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
Eycon Visual Supervisor
SafeLINC™ Fire Panel Internet Interface
Applying Wireless in Legacy Systems
Cyprus Conference 2007 Simplex PoE Clocks. 2 Simplex PoE Clocks.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
eAutomation Enabler – Advantech Industrial NETworking
Windows Server 2008 Chapter 6 Last Update
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
Make the most of your energy December 2008 ECC21 Needing a total network solution? PowerLogic Ethernet Communications Card (ECC21)
DSL 305 Series ADSL Modem. Types of DSL305 series DSL305E ADSL Modem  PPP Half-Bridge (Default)  Transparent Bridge DSL305EU ADSL Router/Modem.
Ch. 5 – Access Points. Overview Access Point Connection.
G650 Generator Protection & Control System
Field Proven Performance – Industrial Grade Support DATA-LINC GROUP Training: LincView OPC Released: 2012/02/04.
Ch 11 Managing System Reliability and Availability 1.
Uniflair pCOWeb Ethernet interface card.
Looking for a more powerful circuit monitor?
12-/24-Port Gigabit IEEE 802.3at High Power Injector Hub HPOE-1200G HPOE-2400G.
NETWORK CENTRIC COMPUTING (With included EMBEDDED SYSTEMS)
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Private and Confidential TraceTek iServer Concepts, Set-up, Operation.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
Chapter 6 Configuring Windows Server 2008 Printing
XP New Perspectives on Browser and Basics Tutorial 1 1 Browser and Basics Tutorial 1.
1 Fluke DAQ Software Visual Demo Guide 2680A-APSW.
ACM 511 Chapter 2. Communication Communicating the Messages The best approach is to divide the data into smaller, more manageable pieces to send over.
Microsoft Internet Information Services 5.0 (IIS) By: Edik Magardomyan Fozi Abdurhman Bassem Albaiady Vince Serobyan.
Need to enhance your network?
Network Management Tool Amy Auburger. 2 Product Overview Made by Ipswitch Affordable alternative to expensive & complicated Network Management Systems.
Who is Inner Range? Inner Range is an Australian Electronic Security Manufacturing Company. Established in 1988 with a Major focus on the Australian Security.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
Smart Switches FS526T / FS750T / GS748T / GS724T
PowerLogic® PowerView Software
Advancing eAutomation 2-port Ethernet to RS-232/422/485 Data Gateway ADAM-4570 Reported by Alex Hsueh IAG Web & Comm. PM
M340 Modbus Plus Proxy Link legacy systems to Ethernet
Internet 0 for Industrial Applications Fred Cohn 13-Dec-07.
SmartMQn Motor Horner APG, LLC September 9, 2008.
1 Microsoft Windows 2000 Network Infrastructure Administration Chapter 4 Monitoring Network Activity.
PowerLogic PowerView v2.0 software
New product introduction:
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
1 Chapter Overview Modems The Internet and Web Browsers.
MCSE Guide to Microsoft Exchange Server 2003 Administration Chapter One Introduction to Exchange Server 2003.
Hands-On Microsoft Windows Server 2008 Chapter 5 Configuring Windows Server 2008 Printing.
11111 Apollo Internet Monitoring Tutorial Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, CT (203)
Run the on your PC to start the firmware configuration process Run IP Config Tool.
Hands-On Microsoft Windows Server 2008 Chapter 6 Configuring Windows Server 2008 Printing.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
Frequently Asked Questions (FAQ)
Printer Admin Print Job Manager
NT24k® & 1000 PoE+ Offerings October 2016.
Ethernet Gateway EGX200 - EGX400
Integrated gateway-server
PowerLogic™ offer for the basic metering market
PowerLogic ION6200 Power and energy meter.
Field installable, upgradeable and scaleable
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

Integrated gateway-server for entry-level system monitoring PowerLogic EGX300 Integrated gateway-server for entry-level system monitoring

Outline Two parts for training Sales/Market Information Product Information

Sales/Marketing Information Part I

Entry Range Monitoring – Why? Not every customer needs ION Enterprise or EEM Some just want the basics Keep it simple Not every sales person can sell a full function power monitoring system Requires a lot of training Long sales cycle Use entry range monitoring as a way to boost power meter sales

EGX300 An Integrated Gateway-server? What’s that? Let’s see…..

PowerLogic EGX300 Integrated gateway-server Use your existing Ethernet network to access basic electrical system data View data with only a web browser, no power monitoring software needed Log data onboard the EGX300 for historical system analysis View device data through a simple browser – no software needed EGX300 web page Trend plots Data log files EGX100 EGX300 Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100) ION 6200 PM800 Micrologic Sepam

Benefits Get a view of your complete electrical system including: Meters Circuit breaker control units Protective relays Motor controllers Drives Operating on an existing Ethernet network, the PowerLogic EGX300: Accesses multiple Ethernet devices and gateways across the network and logs data from connected devices Simple Ethernet connection with minimal configuration required Offers high performance and reliable communication Helps lower installation costs Provides easy system expansion: Dynamic device additions Is compliant with industry standards (UL, CSA, FCC, CE)

Benefits View real time data using only a web browser Analyse basic data from your electrical distribution system for cost allocation and trending reports Use the embedded web page creation tool to customise your system data views and add additional devices Detect serial devices with device Autodiscovery tool

Benefits Functions as a gateway from Ethernet to serial line devices Connects up to 64 devices per gateway Offers field upgradeable firmware Features Modbus TCP/IP address filtering Features 512 Mb for onboard data logging Workstations Modbus TCP Web browser PLC Master Example: PLC allowed access One workstation not allowed access Level of access configurable for read-only or full access Modbus TCP/IP Filtering Feature controls access to critical devices Modbus serial line critical control devices

EGX300 user interface – per device View real time data per individual device

EGX300 user interface – per device View logged data per device

EGX300 user interface – summary views Overview of all connected devices Overview of all connected devices Overview of load current of all devices Overview of demand current all devices

EGX300 and EGX400 Expected Sell Gate: March 2009 The EGX300 will replace the EGX400 Expected to have a lower CCV, but sell for similar market price Easier to set up - no additional web page programming software needed for standard web pages Same foot print as EGX100 Power over Ethernet control power option for easy installation But the EGX400 has 2 serial ports and has both fiber & copper Ethernet connections The EGX300 can connect to devices via Ethernet and via other gateways, which the EGX400 can not An EGX300 + an EGX100 should have about the same cost, or lower, than an EGX400 Very few customers actually bring fiber to the devices or gateways, but if needed, third party adapters are available

Product Information Part II

Minimum System Requirements Although there is NO need to install any software, the computer accessing EGX300 will need to have a browser installed. We support: Microsoft Internet Explorer 6.0 or higher

Physical Characteristic: Ethernet 10/100BaseTx Media Type: 10T/100Tx Auto 10BaseT-HD 10BaseT-FD 100BaseTx-HD 100BaseTx-FD Framing: Ethernet II & 802.3 (SNAP) IP Parameters: Address, Subnet Mask, & Default Gateway Protocols: HTTP, ModbusTCP/IP, FTP, SNMP (MIB II), SNTP, SMTP Connector: RJ45 Pinout: Industry standard Supports 48 concurrent ModbusTCP/IP connections Duplicate IP address detection (FDR basic)

Physical Characteristic: Serial Serial Line All lines optically isolated Physical interface: RS485 4-wire, RS485 2-wire, RS232 Protocols: ModbusRTU, POWERLOGIC (SY/MAX), ModbusASCII, Jbus Baud: 2400–38400bps (RS485); 2400-57600bps (RS232 ASCII) Parity: None, Even, & Odd Response timeout: 0.1 to 10 seconds (default = 3 seconds) Connector: RS485 5 position plugable screw-terminal RS232 RJ45 Pinout: RS232 Industry standard EIA561 for RJ45 Note: EGX300 is internally connected: no need to physically connect the EGX300 for two wire mode.

Physical Characteristic: Exterior RJ45 Ethernet port (IEEE802.3af) Control power: 24 Vdc or Power-over-Ethernet (PoE) LED indicator for power & status Recessed reset button LED indicators for Ethernet and serial communications

Physical Characteristic: Exterior RS485 serial port Bias, Termination, and 2-wire / 4-wire jumper switches RS232 serial port (RJ45 connector)

Transparent Ready {TRe} Embedded web server provides real-time tabular data views for all supported device types Single Device Basic Readings Summary Device Views Circuit Summary Load Current Summary Demand Current Summary Power Summary Energy Summary Advanced users can create custom web views

TRe: Setup Ethernet & TCP/IP Serial Port Remote Device Connections Device List Device Logging Device Log Export Date and Time SNMP Parameters Modbus TCP/IP Filtering Documentation Links User Accounts Web Page Access Preferences

TRe: Setup => Auto Discovery EGX300 features the ability to “Auto Discover” devices in its daisy chain The EGX300 will not find remote devices; the user will need to define a locate address and remote address Look under the device list and scroll to the bottom of the page The user needs to setup the right baud rate and settings for this ability to work. Press to Discover

TRe: Setup => Data Export Users have three options Disable Export via FTP Export via E-mail Users will have to setup logging first before choosing either option of FTP or E-mail Uses can now only send “incremental” data versus ALL data with the EGX400

TRe: Monitor => Single Device Page The EGX300 has the ability to display real time readings from devices. The devices can be selected individually All data displayed has been scaled and set at factory Any unique requests will have to be done as a custom page

TRe: Monitor => Summary Pages Summary Pages are standard with TRe level 2 support. Users can select ALL or individual pages to be displayed the summary pages. Pages to be displayed: Circuit Summary Load Current Demand Current Power Energy

TRe: Monitoring => Logging Embedded web server provides user selectable topics per device Provides logging function to store data from serial devices on 5, 15, 30, or 60 minute intervals Stores up to 152 days (60 minute interval) of recorded readings for up to 32 connected serial devices Embedded web server provides a graphical view of stored data logs Provides Simple Mail Transfer Protocol (SMTP) to E-mail stored device data logs on user defined intervals Provides File Transfer Protocol (FTP) server to access device data logs Provides File Transfer Protocol (FTP) client to send device data logs

Logging File: Example of CSV

Monitor: Trend Plots through logging

TRe: Monitoring => Custom Pages EGX300 will allow users to transfer their own custom pages Custom pages will allow users to have the flexibility to create their own custom solution

TRe: Documentation As part of TRe, users can transfer documentation or create documentation links Users can store up to 512 Mb The documentation can link to other devices that have web server capabilities

Control On the Control page, users can reset the values of their individual devices.

Diagnostic Users can: Look at stats for the EGX300 Read devices on this page Check Communication Connection The stats information will be used by design and tech support to analyze the system situation

Diagnostic: Accumulative Connections Users can click accumulative connections and displayed previous connections This is valuable in terms of security to keep track of users who have logged on before.

Maintenance Log EGX300 provides the ability to record maintenance log files. Typical users can record simple text information about system or challenges.

Advance Features: Remote Connection Under Remote Device Connection, users can setup logging remotely and access devices remotely

Custom Logo Logo Users can customize splash screen, logo, color, and favicon Please refer to the white paper for detail specifications This will allow Integrators to add more value for their services Splash Screen

Device Types for Support => Refer to next slides for level of support ATS48                                                                    ATV61                                                                    ATV71                                                                    CM100/200                                                            CM2000                                                                 CM3000                                                                 CM4000                                                                 Enercept                                                                 Energy Meter ION6200                                                                 ION7300 ION7650                                                                 Micrologic A                                                           Micrologic H                                                           Micrologic P                                            Model98 -modbus Model98-plogic    Motorlogic Plus Motorlogic Plus II                              MVSS/RVSS    PM200                                                                  PM6-mdbus PM6-plogic                                                           PM700                                                                    PM800                                                                 Sepam 2000                                                         Sepam Series 20                                                Sepam Series 40                                                Sepam Series 80                                                TeSys T                                                                                                              

Level of Support TRE Compatibility View data SMS Compatibility Transfer datalogs, waverform captures, device based alarms ION E Compatibility CM100/200 x CM2000 series CM4000 series Enercept Energy Meter PM200 series PM600 series (modbus/powerlogic) PM700 series PM800 series ION6200 series

Level of Support TRE Compatibility View data SMS Compatibility Transfer datalogs, waverform captures, device based alarms ION E Compatibility ATS48 x * ATV61 ATV71 Model 98 (modbus/powerlogic) Motorlogic Plus Motorlogic Plus II MVSS/RVSS TeSys T Sepam 2000 Sepam 20 Sepam 40 Sepam 80 * Device not supported in ION E

Level of Support TRE Compatibility View data SMS Compatibility Transfer datalogs, waverform captures, device based alarms ION E Compatibility Micrologic A x Micrologic H Micrologic P

Application Architecture How to address the following situations: Two and Four Wire Systems Remote Access to Other Gateways

Two and Four Wire Systems Ethernet Network RS-485 (4 Wire) RS-485 (2 Wire) N < 32 Up to 64 Devices can be view by one EGX300 EGX300 can remotely connect to other gateways

Remote Access to Other Gateways Ethernet EGX300 EGX100 EGX300 can poll EGX100 through Ethernet

Obsolescence Plan EGX300 will be introduced by Q1 2009 We will stop selling EGX400 by Q1 2010 We will have stock to replace existing EGX400 for warranty/repair purposes for about three years Special Substitution Use Cases (refer to following slides after): Second Serial Port Older Systems

Second Serial Port Ethernet EGX300 EGX100 N <= 32 N <= 32 Up to 64 Devices can be viewed by one EGX300 EGX300 can remotely connect to other gateways

Legacy Systems Ethernet EGX300 CNV100 2 wire System 4 wire System

Accessory Kit Allows configuration via RS232 serial or Ethernet port Kit Contents RJ45 to DB9F adapter CAT5 Crossover cable, 3-meters (10-feet), orange Instruction sheet Ordering Information TCSEAK0100 Market Price (average) $50 (USD)

IF USB ONLY, need converter to serial Configuration Kit

Accessories - PoE Injector (IEEE 802.3af) Active mid-span device with universal power cord Contents Universal power cord (IEC-60320-C13 & IEC-60320-C14, 3-meters (10-feet) Plug adapters for Australia, Europe, UK, USA Instruction sheet Ordering Information TCSEAV0100 Market Price (average) $80 (USD)

PoE Injector Kit

FAQ Are we limited to the predefine topics already in the logging section setup? No, we can add more topics; however, we are limited to logging 12 topics What type of file formats are supported? Most files formats are supported, e.g. jpeg, swf, doc, xls Can divide the network into 2 segments to get faster response? Buy one EGX300 and one EGX100 Do we support other web browsers? Our pages can be viewed in other browsers

FAQ Continuation Do we support ION protocol? At this time, we do not support ION protocol. How much memory does EGX300 support? 512 Mb How many e-mails will be sent from the EGX300 for logging? The number of e-mails sent will be determine by number of devices logged. Does EGX300 support SNMP? Yes, it supports the standard MIB (II).

For more information … Please visit www.PowerLogic.com

Appendix User interface following in the next slides

EGX300 user interface – real time data

EGX300 user interface – maintenance

EGX300 user interface – summary device

EGX300 user interface – summary device

EGX300 user interface – summary device

EGX300 user interface – summary device

EGX300 user interface – summary device

EGX300 user interface – diagnostics

EGX300 user interface – setup

EGX300 user interface – setup

EGX300 user interface – setup

EGX300 user interface – setup Automatically detect networked devices Simplifies initial setup Promotes easy system expansion

EGX300 user interface – setup

EGX300 user interface – setup Choose the logging intervals Choose from a customizable list of logging topics and log up to 10 Device Logging

EGX300 user interface – setup

EGX300 user interface Choose to receive the most up-to-date data or all data sent via email or ftp

EGX300 user interface – setup Password protection and controlled network access ensures data and system security Repalce with Fake user ID

EGX300 user interface – setup

EGX300 user interface – setup

EGX300 user interface – setup

EGX300 user interface – setup

EGX300 user interface – basic readings

EGX300 user interface – accumulated value

EGX300 user interface --