To be familiar with the equipment, facilities and security systems, used in the synthesis of radiopharmaceuticals labeled with positron emitters. Identify.

Slides:



Advertisements
Similar presentations
Hoshizaki America has built a legacy of quality design, reliability and customer commitment. In our Commercial Series refrigeration line, youll see solutions.
Advertisements

Contents: Cover
Flammable and Combustible Liquid & Compressed Gas Handling and Storage
Fired And Unfired Pressure Vessels
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
Installation. Indoor Unit Installation Typical Installation.
Manual Set-Up for Density by Hydrometer Method ASTM D1298, D287, D6822 and IP160 Feb
Radiopharmaceutical Production Filter integrity test STOP.
Types of Exposure Devices
SANITARY DESIGN PRINCIPLES FOR FACILITIES. ZONES OF CONTROL.
CDC/NIH Vertebrate Animal Biosafety Level Criteria ► For all Animal Biosafety Levels (1 - 4)  IACUC Approval  Authorized access to facilities  Animal.
31/03/11FV 1 CEDAR from flammable gas safety point of view.
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
3.03 Understand support services
Spray Finishing Operations/Spray Booth March 9, 2009.
20. June 2005SDW2005: Plasma Cleaning S. Deiries, ESO 1 Plasma Cleaning A new method of ultra-cleaning detector cryostats Sebastian Deiries, Armin Silber,
Alanoud M. Al-Talal Office – Pharmacy Building (8) – 2 nd Floor – Room 63 address –
Gauges and well logging
MCC PRESENTATION - GMP MANUFACTURING ENVIRONMENTS
Laboratory Training for Field Epidemiologists Best infection control measures for sampling venous and capillary blood WHO intermediate recommendations.
Emergency Eye/Face Wash Training Training Provided by University of Wisconsin-Stout Safety and Risk Management Services.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
World Health Organization
Module 11: Use and Care of Equipment At the HIV Rapid Testing Site.
Patrick Thornton, SNS/FPE June 9, 2008
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Introduction to Equipment
Iouri Ivaniouchenkov RAL Safety considerations at RAL July 9, RAL MICE Collaboration Meeting 1.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
Air Conditioning International Mechanical Code
Overview of Cyclotron Facilities
Hot Lab 11. dose calibrator, an ionization chamber used in nuclear medicine to measure the amount of radioactivity of a radionuclide before injection.
VIII.3. Optimization of Protection for Medical Exposures in Nuclear Medicine 1. Design considerations Postgraduate Educational Course in Radiation Protection.
 Radiopharmaceuticals are agents used to diagnose certain medical problems or treat certain diseases. They may be given to the patient in several different.
Sterile Products Lab PHT 434
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Introduction to nuclear medicine technology NMT 231.
PHARMACY IV ADMIXTURE Pharmacy 483 January 18, 2005 Kim Donnelly Affiliate Associate Professor.
Authorization and Inspection of Cyclotron Facilities Design, Layout and Shielding.
Manual Density Business Today
FEDIAF Code of Practice
Progress on Remote Handling Systems TAC 12 Magnus Göhran – WPM 15 th October 2015.
Chemical Sterilization
IAEA International Atomic Energy Agency Presenter Name School of Drafting Regulations for Borehole Disposal of DSRS 2016 Vienna, Austria Containment and.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Sterile Products Lab PHT 434
Radiopharmaceutical Production
Pharmaceutical Quality Control & current Good Manufacturing Practice
USP 797 Guidelines: Compounding Areas and Equipment
3.03 Understand support services PP2
洗手及 负压技术 余 波
Beryllium Handling in the High Temperature Materials Laboratory and Hot Cells.
3.03 Understand support services
Scorpion Product Presentation
JM Martí-Climent, I Peñuelas
Compounding.
N-TOF EAR2 - Vertical beam design & construction - Irradiation facility proposal S. Girod EN-EA.
Overfill Prevention Technology and Maintenance
3.03 Understand support services
Part 2 – Supplied-air Respirators
3.03 Understand support services
Sterile Products Lab PHT 434
3.03 Understand support services PP2
3.03 Understand support services
 Define: The stirring heating plate or heated stirring heating plate has been developed to heat and mix fluids contained in laboratory receptacles such.
3.03 Understand support services
Parker domnick hunter. Safety of Electrical and
3.03 Understand support services
Presentation transcript:

Hot cells and associated systems for the production of radiopharmaceuticals

To be familiar with the equipment, facilities and security systems, used in the synthesis of radiopharmaceuticals labeled with positron emitters. Identify the applicable radiation protection requirements.

Transfer from the cyclotron. What is a hot cell? Characteristics of hot cells. Special features of hot minicells. Synthesis modules. FDG production.

Radiopharmacy (synthesis) Transfer Cyclotron Hot Cells Radiopharmacy (synthesis) After the bombardment in the cyclotron, the radionuclide produced is immediately and automatically transferred to the hot cells located in the radiopharmacy laboratory. It is performed through capillary tubes (eg Teflon and PEEK) through a pneumatic transfer gas push as, for example, He.

Characteristics of transfer lines: Resistant to ionizing radiation. Excellent strength, rigidity and stability in harsh environments and high temperatures. Low friction coefficient and high wear resistance. Chemically resistant and insoluble by common solvents. Low particle generation and high purity to decrease the risk of contamination.

Transfer lines are placed in accessible underground ducts, in a depth between 30 to 40 cm and must be shielded (concrete slabs or several lead plates). For small distances, transfer can take less than 2 minutes, including the time required to purge the line. Transfer tubes emerge from the shield as close as possible to the destination (hot cell). Transfer line for liquid target (18F)

Transfer lines are inserted, for protection, inside other connection tubes (semirigid) of larger diameter. The high activities carried inside the tubes can cause degradation, enhancing activity absorption in its walls, so they have to be replaced periodically (depending on activity produced and the frequency of use).

Synthesis labs adjacent to the cyclotron bunker The length of the transfer line must be as short as possible and in accordance with the regulations, so that: It must be ensured a safe and quick transfer (ej: O15, T1/2 = 2.05 min). A reduction in the losses of the activity on walls and the probability of damage in line (obstruction or rupture) is guaranteed. The lines lenght as short as possible, as well as the associated costs with shielding. Synthesis labs adjacent to the cyclotron bunker

¿Qué es una celda caliente? What is a hot cell? A technological mean of defense, used to manipulate and process radioactive materials. They can be arranged in series, in blocks or individually.

Allow the manipulation and process of cyclotron produced radionuclides, using remote means and/or dispensing synthesis and modules (automatic or semiautomatic) that ensure higher safety and accuracy in radiochemical processing and fractionation. Ensure the protection of operators, facilities and environment, to shield the high level of radiation and prevent the uncontrolled spread of radioactive contamination. Guarantee, by applying the requirements of Good Manufacturing Practices (GMP), the synthesis of radiopharmaceuticals in an aseptic environment.

Structurally constituted by a steel frame supporting the shield Structurally constituted by a steel frame supporting the shield. The cells have in their interior a watertight enclosure, made by stainless steel floor and PVC or acrylic walls. Design based on the principle that the shielding is more economical and more effective if it is as close as possible to the radiation source.

To reduce exposure time, the hot cells have some devices for simple maintenance procedures. There are many different cells and remote handling devices, however, the best choice depends on what is expected.

The hot cells have different systems and safety devices: ventilation, automatic alarms, compressed air, vacuum, radiation detectors, gauges, etc.

Inner surfaces of polished stainless steel of high quality (grade 316 by its resistance to corrosion) and acrylic or Lucite (transparent plastic that replaces glass). Automatic, semiautomatic systems or telemanipulators for operations.

Panels commands with controls: Measurement instruments. Installed services. Technological equipment. Signals and alarms parameters important to safety. Panel command

Interior surfaces are smooth, impervious, continuous, without right angles at junctions. Work surfaces with tray structure (with raised edges) to prevent spills. Permanent installation of components that can not be cleaned properly, should be avoided. Service ducts (electricity, liquids, gases) have seals and penetrate the shielding in a curved form (S-shaped) to prevent radiation streaming.

Scheme of a conventional cell Control panel. Ionization chamber. Leaded glass window. Lighting system. Sealed Enclosure. Lead shielding. Steel cover. Transfer system access. Liquid waste liner vessel. Solid waste liner vessel. Telemanipulator. Radiation Detector.

Accesses For intervention tasks, maintenance, cleaning or replacement of devices in sealed enclosures, gloves, pneumatically operated guillotine doors or other access are needed. Sliding doors The cells will be sealed in accordance with internationally accepted standards.

The introduction of objects and reagents, the extraction of the products and waste disposal systems require sanitary access systems (SAS) maintaining reliable and safe aseptic conditions inside the hot cell.

Different designs of hot cells openings Vertical front access with telemanipulators. Minicells with front access. Central sliding door.

Concrete, lead bricks lead with antimony between 4 -7% to increase its mechanical strength, leaded glass, steel and depleted uranium are used as shielding, supported by rigid steel frames coated with epoxy paint. The thickness of the shielding must be calculated on the basis of type and energy of radiation and the activity to be manipulated. During the commissioning of a new hot cell, the integrity of the shielding must be verified!

Transparent leaded glass windows, conveniently placed on the wall, are used to observe the interior of the cells and to make possible visual control of processes and the radiation protection of the operators. (10 cm lead glass = 5 cm of Pb)

Must be installed with precision, properly adjusted and tight. Remote handling There is commercial availability of two basic designs (by different suppliers) for remote manipulation of materials or equipment within the hot cells: Manipulators Must be installed with precision, properly adjusted and tight.

Length of ~ 1 m mounted on shielded ball joints placed on the shielded wall. Ball joint for the telemanipulator With interchangeable edge, allows the grip replace without the necessity of removing the enclosure.

Telemanipulators Are used if the wall thickness of the shield is greater than 100 to 150 mm. Recommended if operations are complicated, sensitive or require greater precision.

Ventilation Must comply with the requirements of Good Manufacturing Practices. To prevent radioactive spreading, the enclosure should be kept in depression. To prevent the introduction of powder and the spread of any contaminated particles, HEPA (High Efficiency Particulate Arresting) filters must be installed (inlet and outlet). Activated carbon filters at the exit, for gases.

Minicells Specially designed for PET technology. Used for automated synthesis of PET pharmaceuticals and dispensing into vials and syringes. Completely closed with controlled airflow, double door (exterior is shielding, insulation inside).

Shielding of lead - 75 mm and more. Filtration: HEPA and activated carbon. Interlocks: opening and transfer. Aseptic conditions (GMP). Simple or double cells, with independent operation.

Autoclave with capacity for dozens of vials. Radiation detectors inside and outside. Manometer to measure filter clogging. Pressure gauge for measuring the pressure difference between the interior of the cell and the laboratory.

The small half-life of the produced radionuclides and the energy of the annihilation photons lead to the need of attention directed to both the processing and handling, according to regulations. The chemical synthesis shall be fast, reliable, reproducible, GMP compliant, radiologically safe, automatic and remote. Synthesis modules

Equipment where all processes (chemical in nature) necessary for the production of PET radiopharmaceuticals are performed. They operate automatically and through a software control, which monitors the entire process through a computer.

Use of disposable sets of reagents. Since the final product is injectable, it must be sterile and pyrogen free. The synthesis module has high technological complexity.

FDG Production (example) Before each synthesis the cell has to be cleaned and the synthesis module reloaded with the reagents necessary for the process. Use of disposable kits or integrated cassettes (preloaded with pharmaceutical reagents) which are positioned or adjusted in a straightforward way, avoids the use of manual measurements of reagents, which suppresses the risk of human error.

The F18 in the synthesis module reacts in a series of steps with other chemical reagents, and fluorodeoxyglucose (FDG) is produced (typically in 1 hour). Subsequently the material is transferred to a dispensing hot cell where, with the help of an automatic dispenser, it proceeds to fill the vials to provide, under aseptic conditions, the final sterilization by autoclaving.

The activity is verified with the activimeter. The vials are placed in appropriated containers. Later they are packaged for distribution.

Quality control Sampling and strict quality controls to ensure the quality of the product to be administered to patients. Laminar flow