© Fluke NetworksVisiFault L&L June 2004 VisiFault Visual Fault Locator (VFL) New tool traces fiber, verifies continuity and polarity, helps find breaks.

Slides:



Advertisements
Similar presentations
© DIAMOND Headquarters / F-3000 r & rs / / 1 WERE WELL CONNECTED F-3000 r & F-3000 rs connectors.
Advertisements

R&M Fiberliner LAN / WAN applications R&Measynet.
Industrial Segment Alternative Power Generation
Amphenol Outdoor Connectors
TX40 and CX40 feature presentation. Multi-functional solution Unique product features - enhanced applicability.
RiT PatchView Solution
Cable Probe. Safety First System can conduct electricity Do not use in flammable atmosphere Use proper personal protective equipment.
© DIAMOND SA / X-BEAM / / 1 X-BEAM Connector Up to 4 channels SM and MM optical connections based on Expanded Beam technology.
Session 4: Termination and Splices. 2 FO Connectors Specifications Specifications Loss Repeatability Environment (temp, humidity, vibration, etc.) Reliability.
Psion Teklogix 7535 Handheld Computer.
Psion Teklogix 7530 Handheld Computer. Super Rugged –Temperature Range: -22 F to 140 F (-30 C to +60 C) –IP67 –Drop rating: 1.5 meters (26x) PLUS 2.0.
MFS, MPO 4/8/12-Fiber connectors and Fan-Out assemblies.
© DIAMOND SA / / 1 Alberino CRA Alberino fixing system for modular constructions within industrial Mennekes housing.
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
New Earth Testers from Megger Dover
ZERO A MINI INTEGRATED POINTER ILLUMINATOR MODULE (MIPIM) TO A SERVICE RIFLE/INFANTRY AUTOMATIC RIFLE.
SUPER PASS II Personal Alert Safety System Charles Montgomery Fire Chief Course Developed by Lt. Ricky Phillips Sam Johnson Assistant Chief.
Pursuit of Better testing Instrument Let's go in the grandway......
GET THE MOST ADVANCED FTTH FIBER INSPECTION AND TEST SOLUTION ON THE MARKET. TK-1-FIP-FP4D NOW ONLY 3’350.- CHF* *(SPECIAL ACTION ONLY UNTIL 30. September.
Visible Laser Light — Do Not Stare into Beam or View Directly with Optical Instruments Initials: __________Date: __________ CW power: ______________WType:
1Rugby 55 Presentation – January 2007 The Rugby 55 User Presentation.
Optical Fiber Testing Paul Minko EE 566 Oct. 22, 2003.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
OPTICAL MEASUREMENT DEVICES PRESENTED BY POOJA.P. NIKHIL SHARMA POOJA PRASAD RAJNEESH YADU ANNAPURNA CHANDRAKAR.
Content :  Indoor fiber optic cables  The benefits of indoor Fiber Optic Cable  The features of indoor Fiber Optic Cable  Tight-Buffered Cable  Consists.
TESTING MULTIMODE FIBER
Testing Optical Fiber Links
1 Nexans Cabling Solutions Fibre solutions for fast deployment Joost Grillaert.
© DIAMOND SA / / 1 OAF Optical Attenuating Fiber technology.
1 Fiber Optics LIGHT CRIMP TERMINATIONS USING THE PRENTIUM KIT.
Wireless TL70 70 mm Wireless Modular Tower Light
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006.
© DIAMOND SA / / 1 CLEANING A focal point in fiber optics.
OPTICAL TIME DOMAIN REFLECTOMETER (OTDR)
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
1 Fiber Optics FIBER PERFORMANCE. 2 Fiber Optics The purity of optical fiber is critical for the best transmission of an optical signal inside a fiber.
Installation and testing
© DIAMOND SA / / 1 Quality, Safety and reliability “one-hand” operation VIM DIAMOND VIDEO INSPECTION MICROSCOPE.
Network IQ Training Manual Chapter 6 - Fibre Testing and Measurement
Fiber Optics FUSION SPLICING.
1 Fiber Optics EPOXY/POLISH TERMINATIONS. 2 Fiber Optics A WORD OF CAUTION WHEN TERMINATING FIBER. THERE ARE SPECIFIC SAFETY PROCEDURES THAT NEED TO BE.
Products List Laser Source (Handheld) Laser Source (Desk-top) Optical Power Meter (Handheld) Optical Power Meter (Desk-top) Optical Attenuator (Handheld)
Certified Fiber Optic Training
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
May Fiber Optic Technology Basics May 2008 WHY USE FIBER OPTICS?  Superior Signal Quality  Long Distance Signal Transmission  Protection from.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
NAVIGATOR™ Portable Balances
Introducing gigahertz-bandwidth photodetectors for the visible and near-IR spectral range that provide highest performance-to-price ratio available today!
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
Copyright © 2005 Rockwell Automation, Inc. All rights reserved. 1 Allen-Bradley LaserSight 42CM Launch December 2005.
ORDERING INFORMATION PART NUMBER DESCRIPTION OPTICAL PWR BUDGET MAX DISTANCE (Option) PRODUCT SPECIFICATION EL – 32V2402 TX / RX LINK DIGITAL VIDEO 32CH.
ORDERING INFORMATION PART NUMBER DESCRIPTION OPTICAL PWR BUDGET MAX DISTANCE (Option) 8dB 10Km SINGLE-MODE 9/125um PRODUCT SPECIFICATION EL – HD2202 TX.
Camera Basics. Film (Analog) Cameras Digital Cameras Types of Cameras.
ORDERING INFORMATION PART NUMBER DESCRIPTION OPTICAL PWR BUDGET MAX DISTANCE (Option) PRODUCT SPECIFICATION EL – 8V2202 TX / RX LINK DIGITAL VIDEO 8CH.
ORDERING INFORMATION PART NUMBER DESCRIPTION OPTICAL PWR BUDGET MAX DISTANCE (Option) PRODUCT SPECIFICATION EL – 2V2202 TX / RX LINK DIGITAL 2CH VIDEO.
Online store for flashlights Vortex Crank Flashlight Spotlight Illumination Range = 100 feet (30m) Spotlight Illumination Range (Underwater)
FCC DIGITAL 1ch VIDEO&1ch AUDIO LINK PRODUCT SPECIFICATION
FCC DIGITAL 4CH VIDEO LINK PRODUCT SPECIFICATION
FIBER OPTIC VIDEO + DATA RT/COT
Introduction to Computers
DIGITAL VIDEO 16CH MUX SERIES
Peter Dennis – Dover PPM Communications
Personal Protective Equipment
Guidelines for Fiber Optic Design and Installation
FTTH PRODUCTS INTRODUCTION
Universal Interrupted Electronic Oil Primary R7184U Training Module
UV LED Flashlight Bring Something Smarter & Safer!!!
Presented by Product Marketing
Presentation transcript:

© Fluke NetworksVisiFault L&L June 2004 VisiFault Visual Fault Locator (VFL) New tool traces fiber, verifies continuity and polarity, helps find breaks

2 VisiFault L&L June 2004 Key features  Bright visible light for fiber tracing, continuity and polarity verification, and fault location  Rugged design is built to last  Easy to use

3 VisiFault L&L June 2004 Tracing, verification and fault location  Emits a bright beam of readily visible red light  Similar to a laser pointer  Basic tool for visually tracing fibers  Connect to one end of a fiber then locate the other end, even if it one of many fibers either in cable or terminated in a rack  Quickly check end-to-end continuity (no breaks)  Verify the proper polarity (orientation) within a multi-fiber connector like the MT-RJ  Quickly illuminate fiber faults  Breaks, damaged connectors on patch cords, defective splices in splice trays, tight fiber bends in and around equipment racks  Light may not be visible through thick or dark-colored cable sheaths, connector boots or dust caps

4 VisiFault L&L June 2004 Tracing and troubleshooting

5 VisiFault L&L June 2004 Rugged design is built to last  Withstands drops, impacts and rough treatment  Features a durable energy-absorbing holster, impact- resistant case and heavy-duty end cap  ensuring years of trouble-free operation in demanding field applications  Industrially engineered custom-case  mechanically tough  Unlike more fragile VFLs that utilize a flashlight body or plain plastic case  compact for field-use  ergonomically designed for comfort

6 VisiFault L&L June 2004 Easy to use  2 output modes  steady for fault illumination  flashing for easier location  Status LED on front panel  Universal 2.5mm adapter  easy connection to SC, ST, FC and FJ connectors  Optional 1.25mm universal adapter  easy connection to LC and MU connectors  Over 80 hours battery life with two AA batteries  Attach the VisiFault to your belt using a lanyard or in the carrying case  always on hand when you need it

7 VisiFault L&L June 2004 >80 hours CW battery life Two replaceable AA batteries

8 VisiFault L&L June 2004 Specifications Optical Fiber compatibility multimode and singlemode Wavelength 650nm (visible wavelength) Laser safety rating class II Output power 1.0mW max. Output modes continuous (steady) and flashing (2-3Hz pulsed) Range3 km multimode 4 km singlemode Environmental and mechanical Operating temperature 0°C to 40°C Storage temperature -20°C to 60°C Relative humidity 95% (10 to 35°C) Vibration Random, 2g, Hz Shock1m drop onto all corners and face Altitude 3000m

9 VisiFault L&L June 2004 Specifications General Dimensions (H x W x D)157 x 52 x 33 mm (6.2 x 2.0 x 1.3 inch) Weight, with batteries0.18 kg (5.7 oz) Adapter 2.5mm universal Adapter cap tethered protective end cap Controls on/off, continuous/flashing Battery type 2 x AA Battery life > 80 hours in continuous mode Carry caseSoft with belt loop Safety CSA C22.2 No , EN , CE

10 VisiFault L&L June 2004 Models and Accessories ModelsDescription VisiFaultVisiFault Visual Fault Locator with 2.5mm universal adapter includes multi-language instruction sheets and carrying case AccessoriesDescription NF380Universal adapter for connectors with 1.25mm ferrules

11 VisiFault L&L June 2004 Safety information  Warning label: Class 2 laser  Do not stare into beam  Momentary exposure to the VFL’s output will not damage your eyes, however direct, long-term exposure is potentially hazardous  Cover the output with a dust cap when the VFL is not is use  View the output indirectly by shining the light onto a white card or sheet of paper

12 VisiFault L&L June 2004 Overview  Bright red visible laser light source  Accelerates end-to-end fiber continuity checks  Speeds fiber tracing and identification  Simplifies fiber polarity verification  Aids in location of fiber faults including tight bends, breaks and bad connectors  Rugged case survives drops, impacts and vibrations  Features continuous and flashing modes  Connects to 2.5mm standard and 1.25mm SFF connectors  >80 hours CW operation on 2 AA batteries  Handy lanyard attachment and carrying case