Industrial Automation

Slides:



Advertisements
Similar presentations
TURKEY AWOS TRAINING 1.0 / ALANYA 2005 TRAINING COURSE ON AUTOMATED WEATHER OBSERVING SYSTEMS ( AWOS ) MODULE C.2: COMMUNICATION SONER KARATAŞ ELECTRONIC.
Advertisements

PLC Selection, Components, and Communication
Categories of I/O Devices
Modelling and Simulation 7. September 2014 / Dr. –Ing Naveed Ramzan 1 Instrumentation and control Department of Chemical Engineering, U.E.T. Lahore Pakistan.
SPI Serial Peripheral Interface. SPI Serial Peripheral Interface is communication between two devices, one bit at a time sequential one bit at time over.
Integrated Device Networks for ControlLogix ® Systems “Practical Applications for HART I/O”
Csc333 Data communication & Networking Credit: 2.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
CSCI 4550/8556 Computer Networks Comer, Chapter 10: LAN Wiring, Physical Topology, and Interface Hardware.
Data Communications and Computer Networks
Device Management Protocols Protocoles de gestion des appareils Gerätezugangsprotokolle Electronic Device Description Prof. Dr. H. Kirrmann ABB Research.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Remote Automations Solutions RTU – The Glue Remote Control of Valves.
Chapter 8 Output Modules.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
AMG Attendance System Product Description Copyright © 2009 AMG Employee Management, Inc.AMG Employee Management, Inc.
LabView Users Group Meeting June 20 th, 2006 Process Control Using Compact Field Point/Labview Real-time Michael Tockstein Microelectronics Technology.
2 Lines Electronics I 2 C Analyzer Ching-Yen Beh Robert S. Stookey Advisor: Dr. J. W. Bruce.
Industrial Automation Automation Industrielle Industrielle Automation 4Application Layer Protocols 4.1 Device Management Protocols protocolos de gestión.
Ron Helson HART Communication Foundation Austin, TX
SCADA and Telemetry Presented By:.
Computers in Surveying SVY2301 / E4006 Automated Surveying.
1 Chapter 2: LAN Standards, Physical Connectivity, and Media Access.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
A brief study Mrs. Tannistha Kapoor Engr. O&M/C&I
Fayoum University Faculty of Engineering Electrical Engineering Department E-voting system Using Smart Card Under the supervision Of: Dr. Magdy Amer.
Calibrating and Trimming Instruments via HART Agenda: What is HART? / History / Signal / Message Frame HART Command Structure Connecting a HART Transmitter.
Smart transmitters.
Ch Review1 Review Chapter Microcomputer Systems Hardware, Software, and the Operating System.
Input/OUTPUT [I/O Module structure].
Chapter 1 Introduction to Computer Networks and Data Communications Data Communications and Computer Networks: A Business User’s Approach.
ACM 511 Chapter 2. Communication Communicating the Messages The best approach is to divide the data into smaller, more manageable pieces to send over.
Final Control Chapter 7.
Application Protocol for Veris E30 Panel-board Monitoring System Jaein Jeong UC Berkeley LoCal Workshop Oct 5 th, 2009.
Interrupts and DMA CSCI The Role of the Operating System in Performing I/O Two main jobs of a computer are: –Processing –Performing I/O manage and.
Universal Synchronous/Asynchronous Receiver/Transmitter (USART)
© Janice Regan, CMPT 300, May CMPT 300 Introduction to Operating Systems Principles of I/0 hardware.
1 Microprocessor-based Systems Course 9 Design of the input/output interfaces (continue)
Line Coding, Modem, RS232 interfacing sequences.
Graphical Output Package for Industrial Sensor May Team Members Steve Bower – CprE Ken Hall – CprE Roar Lien – CprE Jim Sproul – CprE Rich Matus.
1 Review - Computing Basics n Key points: u Computer Hardware and Software. u Binary Number System u Networking Terminology F Networking F LANs F WANs.
2A – Acquisition and Automation technology Application Features Summary.
Seminar ON SMART SENSOR Submitted by : SUBIR KUMAR GHOSH Roll No. IN-14/04 Electrical & Instrumentation Deptt. B.E 7th Semester JORHAT ENGINEERING COLLEGE,
(More) Interfacing concepts. Introduction Overview of I/O operations Programmed I/O – Standard I/O – Memory Mapped I/O Device synchronization Readings:
Overview of computer communication and Networking Communication VS transmission Computer Network Types of networks Network Needs Standards.
1 Lecture 7 LAN Wiring, Physical Topology, and Interface Hardware Computer Networks CS 4316.
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Lesson 3 — How a Computer Processes Data Unit 1 — Computer Basics.
Ultima ® X Gas Monitor with HART Display Version.
Chapter 17 Looking “Under the Hood”. 2Practical PC 5 th Edition Chapter 17 Getting Started In this Chapter, you will learn: − How does a computer work.
PHY 201 (Blum)1 Microcode Source: Digital Computer Electronics (Malvino and Brown)
NETWORKING FUNDAMENTALS. Network+ Guide to Networks, 4e2.
1 Chapter Overview Modems The Internet and Web Browsers.
Standards Certification Education & Training Publishing Conferences & Exhibits Automation Connections ISA EXPO 2006.
The OSI Model. Understanding the OSI Model In early 1980s, manufacturers began to standardize networking so that networks from different manufacturers.
COMPUTER NETWORKS CS610 Lecture-11 Hammad Khalid Khan.
Networking A method of exchanging data between two physically distant nodes. Two devices are said to be networked when a process in one device is able.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Chapter 3: Network Protocols and Communications
I/O SYSTEMS MANAGEMENT Krishna Kumar Ahirwar ( )
PLC Terminology and Application
Programmable Logic Controllers: I/O
DT80 range Modbus capability
A Wireless LAN technologies IEEE
Instructor Materials Chapter 3: Network Protocols and Communications
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
The simple system solution
Presentation transcript:

4. 4.1.1 Industrial Automation Automation Industrielle Industrielle Automation Device Management Protocols Protocoles de gestion des appareils Gerätezugangsprotokolle 4. 4.1.1 The HART Protocol Prof. Dr. H. Kirrmann ABB Research Center, Baden, Switzerland 2009 March HK

The classical solution for analog values 4.1.1 Current Loop The classical solution for analog values

Field device: example differential pressure transducer 4..20 mA current loop fluid The device transmits its value by means of a current loop

4-20 mA loop - the conventional, analog standard (recall) The 4-20 mA is the most common analog transmission standard in industry sensor transducer reader reader reader voltage source 10V..24V 1 2 3 i(t) = f(v) v RL1 R1 RL2 R2 RL3 R3 RL4 RL4 conductor resistance i(t) = 0, 4..20 mA The transducer limits the current to a value between 4 mA and 20 mA, proportional to the measured value, while 0 mA signals an error (wire break) The voltage drop along the cable and the number of readers induces no error. Simple devices are powered directly by the residual current (4mA) allowing to transmit signal and power through a single pair of wires.

Practically all 4..20mA devices come equipped with HART today Data over 4..20 mA loops Practically all 4..20mA devices come equipped with HART today About 15 Mio devices are installed worldwide. more info: http://www.hartcomm.org/ http://www.thehartbook.com/default.htm

HART - Principle HART (Highway Addressable Remote Transducer) was developed by Fisher-Rosemount to retrofit 4-to-20mA current loop transducers with digital data communication. HART modulates the 4-20mA current with a low-level frequency-shift-keyed (FSK) sine-wave signal, without affecting the average analogue signal. HART uses low frequencies (1200Hz and 2200 Hz) to deal with poor cabling, its rate is 1200 Bd - but sufficient. HART uses Bell 202 modem technology, ADSL technology was not available in 1989, at the time HART was designed

universal hand-help terminal Installation point-to-point multidrop universal hand-help terminal taken from: www.hartcomm.org

It is round because most hydraulic instruments have a round case. The Round card http://www.fint.no/ha-i4012.pdf The round card is a standardized printed circuit board that can be mounted in an instrument, containing the modem, a processor, RAM, EPROM and all the logic and software necessary to execute the HART protocol. It is round because most hydraulic instruments have a round case.

Hart frame format (character-oriented): HART - Protocol Hart communicates point-to-point, under the control of a master, e.g. a hand-held device Master Slave command Indication Request time-out response Response Confirmation Hart frame format (character-oriented): preamble start address command bytecount [status] data data checksum 5..20 (xFF) 1 1..5 1 1 [2] (slave response) 0..25 (recommended) 1

total 44 standard commands HART - Commands Universal commands (mandatory): identification (each manufactured device is identified by a 38-bit unique identifier), primary measured variable and unit (floating point format) loop current value (%) = same info as current loop read current and up to four predefined process variables write short polling address sensor serial number instrument manufacturer, model, tag, serial number, descriptor, range limits, … Common practice (optional) time constants, range, EEPROM control, diagnostics,… total 44 standard commands Transducer-specific (user-defined) calibration data, trimming,…

HART commands summary Universal Commands Common Practice Commands Device-Specific Commands (example) • Read manufacturer and device type • Read primary variable (PV) and units • Read current output and percent of range • Read up to four predefined dynamic variables • Read or write eight-character tag, 16-character descriptor, date • Read or write 32-character message • Read device range values, units, and damping time constant • Read or write final assembly number • Write polling address • Read selection of up to four dynamic variables • Write damping time constant • Write device range values • Calibrate (set zero, set span) • Set fixed output current • Perform self-test • Perform master reset • Trim PV zero • Write PV unit • Trim DAC zero and gain • Write transfer function (square root/linear) • Write sensor serial number • Read or write dynamic variable assignments • Read or write low-flow cut-off • Start, stop, or clear totalizer • Read or write density calibration factor • Choose PV (mass, flow, or density) • Read or write materials or construction information • Trim sensor calibration • PID enable • Write PID setpoint • Valve characterization • Valve setpoint • Travel limits • User units • Local display information

Device Description Also known as Device Description Language (DDL) or eDDL (electronic Device Description Language), “electronic frontplate” (Elektronisches Typenschild, plaque électronique))

Device access field device SCADA hand-held device network adapter volumetric flow rate type FlowPro manufacturer ABB volumetric flow rate field device cross sectional area: 3 cm2 SCADA pipe inside diameter 2 cm velocity 13.32 m2/s network adapter diff. pressure 9.8 Pa density 0.8 kg/l hand-held device network modem adapter 4-20 mA loop for HART 13.32 9.8 0.8 transmission system (HART or field bus)

Device Description Language Device Description Language DDL allows a field device (slave) product developer to create a description of his instrument and all relevant characteristics, such that it can be represented in any host (master) device. The objective is common “look-and-feel”, independent of the hand-help or SCADA, similar to HTML for a web server. Why not use HTML ? special instructions needed ! (C-like language is used)

Device Description usage DDL Device DDL Source Language Specification Specifications Binary Encoding Source Specification File DDL Compiler "tokenizer" DDL Binary binary file DDL Service Library Host Device A binary form of the source is stored in the hand-help device (could also be downloaded from the field device)

Assessment What is the purpose of the HART protocol ? Which communication is used between a hand-help and a field device ? Which categories of commands do exist ? What is the purpose of the Device Description Language ?