A FOUNDATION FIELDBUS System
SYSTEM302 - Linking Devices 4-20 mA Discrete I/O
WHAT IS A Linking Device? Linking Devices WHAT IS A Linking Device?
A Linking Device Connects: Fieldbus High Speed Ethernet LINKING DEVICES A Linking Device Connects: Fieldbus High Speed Ethernet H1 Foundation Fieldbus Networks Configured by Any FF Configuration Tool Linking Device FIELDBUS H1
LINKING DEVICES MAIN FEATURES
Organizes the communication, Passing the token. LAS Organizes the communication, Passing the token. Fieldbus Ethernet
FF BRIDGES BETWEEN FIELDBUS NETWORKS HSE Linking Device FIELDBUS H1 FIELDBUS H1 DEVICES ON DIFFERENT NETWORKS
DFI302 “DFI302” “SYSTEM302’s Linking Device !”
DFI302 “DFI302” “Much More Than Linking Device !”
Distribution and Scalability Unique Distributed Modular Design Several Parallel Processors working together, as ONE!! Unlimited Expandability: Unlimited I/O Unlimited Control Capability Extreme Control Performance
Each DFI302 PROCESSOR Handles: DFI302 PROCESSORS Each DFI302 PROCESSOR Handles: 256 Conventional Points (512 Points with I/O Coprocessor) 4 FF H1 Networks (Up to 64 Foundation Fieldbus Field Devices) 4 LAS 1 FF HSE Port 1 Modbus Gateway Network (As-i Bus, DeviceNet, Profibus to come) 100 Fieldbus Foundation Function Blocks
DISTRIBUTED ARCHITECTURE Truly Distributed with Horizontal Comunication FIELDBUS H1 FIELDBUS H1 FIELDBUS H1
H1 in a Box- A DFI302 for 4 H1 Networks Fully integrated - HSE + 4 FF H1 + Modbus DF52 and DF53 modules Power Supply and Impedance for 4 FF H1 ports DF51 module HSE 1 Modbus port 4 FF H1ports DF50 module Power Supply for DF51 + I/O modules
Dynamically Instantiable Function Blocks
Available Blocks in DFI302 RESOURCE DESCRIPTION RS RESOURCE TRANSDUCER BLOCKS DESCRIPTION DIAG Diagnostics Transducer HC Hardware Configuration Transducer MBCF Modbus Configuration TRD Transducer INPUT TRANSDUCER BLOCKS DESCRIPTION TEMP Temperature Transducer INPUT FUNCTION BLOCKS DESCRIPTION AI Analog Input DI Discrete Input MAI Multiple Analog Input MDI Multiple Discrete Input PUL Pulse Input
Available Blocks in DFI302 CONTROL AND CALCULATION FUNCTION BLOCKS DESCRIPTION PID PID Control EPID ENHANCED PID – It has all the standard features plus : bumpless or hard transfer from a “manual” mode to an “automatic” mode and bias. APID ADVANCED PID – It has all the standard features plus: bumpless or hard transfer from a “manual” mode to an “automatic” mode, bias. Adaptive gain, PI sampling, deadband for error, special treatment for error, ISA or parallel algorithm,.. ARTH Arithmetic - 9 predefined equation types SPLT Splitter - split ranging and sequencing. CHAR Signal Characterizer - 20 points curve INTG Integrator AALM Analog Alarm ISEL Input Selector - 4 inputs SPG Setpoint Ramp Generator TIME Timer
Available Blocks in DFI302 CONTROL AND CALCULATION FUNCTION BLOCKS DESCRIPTION LLAG Lead Lag DENS Density CT Constant FFET FLIP-FLOP and EDGE TRIGGER MBCS Modbus Control Slave MBSS Modbus Supervision Slave MBCM Modbus Control Master MBCS Modbus Control Slave AEQU Advanced Equations OUTPUT FUNCTION BLOCKS DESCRIPTION AO Analog Output DO Discrete Output MAO Multiple Analog Output MDO Multiple Discrete Output STEP Step Output PID
Homogenous Environment Standard programming language The last language you need to learn Same everywhere Easy Full use of FF Status: bumpless, shutdown, Execution synchronization
SIMILAR TO DCS/PLC, But the signals are now Fieldbus. DFI302 DIRECT I/O ACCESS DIGITAL I/O ANALOG I/O SIMILAR TO DCS/PLC, But the signals are now Fieldbus. HSE DFI302 Modbus FIELDBUS H1 DI DO Pulse 4-20 ma Profibus DP Modbus Other Protocols
I/O Modules List
I/O Modules List
I/O Modules List
I/O Modules List
DFI302 as a MODBUS GATEWAY DFI302 as Modbus Slave DFI302 DFI302 Ethernet DFI302 Proprietary Control Network Fieldbus H1 Legacy system with Modbus card Modbus DFI302 Modbus DFI302 as Modbus Master
MODBUS TPC/IP - Master/Slave MODBUS TCP/IP DFI302 LC700 + ENET700 FIELDBUS H1 FIELDBUS H1
System Architecture
System Architecture
Power Supply Subsystem Modules List
DF52 Fieldbus Power Supply Supply 24VDC for the Field Devices Operates with 90VAC through 220VAC Supplies power up to 64 field devices. DFI302 Integrated Design. Fail Led and Output Circuit. Short-Circuit Protection DIN-rail or panel mount
DF49(DF53) - 2(4) Channel Fieldbus Power Supply Impedance Allows use of standard power supplies. 18 +/-2 V, 300 mA output. Built-in terminator DIN-rail or panel mount Active Impedance, allows redundancy DFI302 Integrated Design. Fail indication Short-Circuit Protection
DF49/53 Terminator Switches + IN - + OUT1 - + OUT2 - + OUT3 - 1 2 3 4 ON + OUT4 - BT
DF47 Fieldbus Safety Barrier Limits power to the classified area. Typically 8 hazardous area devices per barrier. Works as a repeater (Does not need a separate repeater). Uses a independent and isolated power supply.
DF47 Fieldbus Safety Barrier PS Hazardous Area STILL 16 DEVICES PER CHANNEL
Extends the network up to 9,500 mts. Up to 4 repeaters per network. DF48 Fieldbus Repeater Extends the network up to 9,500 mts. Up to 4 repeaters per network. PS
DFI302 Redundancy Redundant LAS Redundant Interface Two paths to the field Redundant LAS Redundant Interface Processor Redundancy Available in January 2002
Choices are everything!