Measurement System Analysis (MSA) Discussions at CSIR S.A. 28-07-2005.

Slides:



Advertisements
Similar presentations
SC 18 Ad Hoc Task Group API Staff Issues Ed Durante, Chair.
Advertisements

ISO 9001:2000 Documentation Requirements
Understanding the Requirements Qimpro Standards Organization
VIII Measure - Capability and Measurement
How ISO9001 Compares with CMM Mark C. Paulk JAN,1995 CMM version 1.1 ISO9001 July 1994 presented by Zhilan Zhou.
Measurement Systems Analysis with R&R INNOVATOR Lite TM The House of Quality presents.
ISO 9001 : 2000.
The Quality Professional: A catalyst for change and excellence… Becoming a quality consultant and Auditor November 10, 2011 Timon Waugh.
Guardian Tier 2 PPAP Guidelines
1 Quality Management Standards. 2 THE ISO 9000 FAMILY ISO 9000: 2005 Identifies the fundamentals and vocabulary for Quality Management Systems (QMS) ISO.
SOFTWARE PROJECT MANAGEMENT Project Quality Management Dr. Ahmet TÜMAY, PMP.
1© M G Gibson 2010RSS Destructive Testing MSA1 ISO/TS 16949:2009(E) and AIAG MSA 4 th edn. (2010) Martin Gibson CStat, CSci, MSc, MBB AQUIST Consulting.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Prepared by Long Island Quality Associates, Inc. ISO 9001:2000 Documentation Requirements Based on ISO/TC 176/SC 2 March 2001.
© ABSL Power Solutions 2007 © STM Quality Limited STM Quality Limited Measurement Systems Analysis TOTAL QUALITY MANAGEMENT M.S.A.
QMS Tips and Traps (ISO TS16949)
ISO 9001:2000 Intro Presented By: Brad D. Agenda Overview of QMS Fundamentals ISO 9001:2000 Overview & Requirements.
ISO 9000 Certification ISO 9001 and ISO
Large Automotive OEM – FMEA Managed Service
8-Aug-15 “"Dana Confidential Information - Those having access to this work may not copy it, use it or disclose the information contained within this work.
4. Quality Management System (QMS)
(Total Quality Management)
Quality Management Standards:
DataLyzer® Spectrum Gage Management System introduces……
QUALITY MANAGEMENT SYSTEM ACCORDING TO ISO
S3: Module D Physikalisch-Technische Bundesanstalt Session 3: Conformity Assessment Module D Peter Ulbig, Harry Stolz Belgrade, 31 October.
Quality Management System
Introduction to ISO New and modified requirements.
Rocky Mountain RAPS Process Validation Presentation 6/7/06 By Clay Anselmo.
VALIDATION METHODOLOGY
ISO 9001:2000 QUALITY MANAGEMENT SYSTEM REQUIREMENTS
Software Quality Assurance Lecture 4. Lecture Outline ISO ISO 9000 Series of Standards ISO 9001: 2000 Overview ISO 9001: 2008 ISO 9003: 2004 Overview.
WHY CONFORMITY ASSESSMENT?. What is conformity assessment?  Conformity assessment is the name given to processes that are used to demonstrate that a.
Introduction to ISO 9001:2000.
Visit us at E mail: Tele:
Success depends upon the ability to measure performance. Rule #1:A process is only as good as the ability to reliably measure.
Your measurement technology partner for global competitiveness CSIR National Metrology Laboratory The National Metrology Laboratory of South Africa Feedback.
Federal Aviation Administration Presented to: By: Date: Oversight Throughout the Supply Chain: Is It Adequate? DOT OIG Audit: Assessment of FAA's Risk-Based.
Paul Hardiman and Rob Brown SMMT IF Planning and organising an audit.
Uncertainty of measurement & Technical Specifications SAAMF Roadshow Durban CSIR NML Eddie Tarnow Metrologist: Torque & Automotive 14 June 2006.
Chapter 20 Measurement Systems. Objectives Define and describe measurement methods for both continuous and discrete data. Use various analytical methods.
SAAMF Roadshow Durban CSIR NML Eddie Tarnow Metrologist: Torque & Automotive 14 June 2006 ISO/TS 16949:2002 certification – Meeting the requirements of.
Validation | Slide 1 of 27 August 2006 Validation Supplementary Training Modules on Good Manufacturing Practice WHO Technical Report Series, No. 937, 2006.
EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION.
It was found in 1946 in Geneva, Switzerland. its main purpose is to promote the development of international standards to facilitate the exchange of goods.
Supplier Performance Development Process
NCSLI 2007 Training Records from an Auditors Viewpoint Shawn Mason Boston Scientific.
Technology Services – National Institute of Standards and Technology Conformity Assessment ANSI-HSSP Workshop Emergency Communications December 2, 2004.
1. Our Presentation Topic: Importance Of Validation & Qualification In Pharmaceutical Industries Presented By: Md. Tanjir Islam (Group C) 2.
Overview of Instrument Calibration Presents by NCQC, India.
TS Standard TS Standard is Globally ISO Technical specification and aim to developed the quality management system for the Automotive Industry.
Integrating QS9000 Requirements
World Health Organization
Module 3 Information about the audit
Awareness program on ISO/TS16949:2002
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Managing Supplier Quality
Supplier Performance Development Process
APQP Quality Planning in ISO 9000/ QS-9000 or ISO/ TS or .....
APQP PROCESS FLOW Prepare for APQP Plan and Define Program
Supplier Quality Assurance Manual
Product and Process Validation JAN ROOVERS ASSOCIATES, INC.
The Quality Control Function
Supplier Performance Development Process
TS Training Presented by: Internal Auditor Training.
ISO-9001:2000 Quality Management Systems
Integrating TS Requirements
Supplier Briefing Pack
Presentation transcript:

Measurement System Analysis (MSA) Discussions at CSIR S.A

Measurement System Manufacturing Process Input Material Process design Product Design (Tolerancing) MachineTooling Parameter variation Method variation Processing material Environment Sources of Variations Measurement

Fundamental Properties of a GOOD measurement system ADEQUATE SENSITIVITY – 10 TO 1 RULE – Instrument ACCURACY (and therefore Least Count) should divide the tolerance ( or process variation) into 10 parts or more – practical minimum point for gauge selection Measurement system ought to be in statistical control – presence of only common causes of variation and not the special causes Variation of measurement system must be small compared to specification limits or process variation (6-sigma) – more PRECISION

Inaccurate and imprecise +

Accurate and imprecise +

Precise but inaccurate +

Accurate and precise +

NATIONAL STANDARD LABORATORY STANDARD WORK STANDARD GAUGE FOR INSPECTION / TESTING RU = RU = RU = 0.01 RU = 0.05 U : UNCERTAINITY RANDOM UNCERTAINITY – FOUND THRU CALIBRATION SYSTEM UNCERTAINITY – OF MASTER TOTAL UNCERTAINITY – SQRT( RU*RU + SU*SU) U = U = U = U =

Process Capability Lower Spec. LimitUpper Spec. Limit 6  Tolerance = T Process Capability = T / 6  > 1.33 Means, 6  < (0.75*T)

Impact of Uncertainty Lower Spec. LimitUpper Spec. Limit 6  Process Tolerance = T ERROR identified through Calibration Process Uncertainty

Questions Can an ISO/TS 16949: 2002 certification program ensure systems and processes which deliver products which conform to a technical specification? Yes, TS SCOPE, point # 1.1, states… This international standard specifies requirements for a quality management system to demonstrate ability to CONSISTENTLY provide PRODUCT that meets product, customer and regulatory requirements Requirements specified in standard are complementary to product requirements Emphasis on PROCESS DESIGN to deliver conformance to product specifications CONSISTENTLY …. Focus on REDUCTION IN VARIATION by asking ongoing capability evaluation…including measurement systems’ variation, which an process engineer must evaluate during development Product and process approval is a requirement throughout SUPPLY CHAIN, which includes elements such as FMEAs, Control Plans, SPC & MSA

Questions Are customer specific MSA requirements addressed in ISO/TS 16949: 2002 audits? Yes, the scope of certification includes ISO/TS CUSTOMER SPECIFIC REQUIREMENTS ISO/TS 16949:2002, POINT # 0.5 : Goals of this Technical Specification, Para #2 This Technical Specification, coupled with applicable customer specific requirements, defines the fundamental quality management system requirements for those subscribing to this documents. Most of the subscribing customers (OEMs asking vendors to get registered to TS 16949) ask usage of AIAG MSA MANUAL

Questions To what degree are customer specific MSA requirements addressed in ISO/TS 16949: 2002 audits? Audits wrt TS are planned considering business processes identified by organization to meet the product and customers needs and expectations, calibration and MSA is one of such processes ISO/TS-16949:2002 (Point # 7.6.1: Measurement System Analysis) Statistical Studies SHALL BE conducted to analyze the variation present in the results of EACH TYPE of measuring and test equipment system. The requirement shall apply to measurement systems REFERENCED IN THE CONTROL PLAN The analysis methods and acceptance criteria used SHALL confirm to those in CUSTOMER REFERENCE MANUALS on measurement systems analysis

Questions Would ISO/TS 16949:2002 auditors benefit from additional training in Measurement System Analysis? Certainly Yes. Rather it’s a REQUIREMENT. Otherwise how could they assess suitability and impact of MESUREMENT SYSTEM ERRORs on products’ quality? Auditor Qualification requires…. 6 years prior experience in AUTOMOTIVE, out of which 4 years in Quality Qualification Course contents and examination includes CORE TOOLS – APQP, PPAP, FMEA, SPC, MSA, etc Ford & GM specific requirements demand even the internal auditors shall be trained and evaluated wrt knowledge on core tools including MSA.

Who conducts the MSA? (supplier/OEM?) The user of measurement system shall conduct the MSA Are FOP, (first of production), tests conducted? Review is Must, if necessary do it! Who is responsible for conducting these tests, OEMs or suppliers? Of course the manufacturer (supplier) Who is responsible for evaluating that the measurement system is capable of performing the required measurements with the desired level of accuracy? Of course the manufacturer (supplier) Do these tests form part of the control plan? Yes, they have to be! Is the understanding that an MSA addresses the measurement accuracy of a measurement system or merely its repeatability/reproducibility? It addresses both – location (accuracy) and variation (precision)

Application of appropriate method TYPE OF GAUGE BIAS / UNCER- TANITY LINEARITYSTABILITYGRR VERNIER 0-150mm SKILL IN HOLDING THE JAWS PARALLALY CMM mm SLIP GAUGES SKILL OF RINGING PLUG GAUGE FOR BORE OF / SKILL ON BORDERLINE CASES