AWAKE Electron Spectrometer Design Simon Jolly 4 th September 2012.

Slides:



Advertisements
Similar presentations
Optics and magnetic field calculation for the Hall D Tagger Guangliang Yang Glasgow University.
Advertisements

AWAKE Electron Spectrometer Simon Jolly 7 th March 2013.
December 10, 2008 TJRParticle Refrigerator1 The Particle Refrigerator Tom Roberts Muons, Inc. A promising approach to using frictional cooling for reducing.
Pepperpot Emittance Measurements of the FETS Ion Source
Study of the Luminosity of LHeC, a Lepton Proton Collider in the LHC Tunnel CERN June F. Willeke, DESY.
Yury CHESNOKOV Crystal Collimation workshop, March 7, 2005 CALIBRATION of CMS CALORIMETERS with LHC PROTON BEAM DEFLECTED BY CRYSTAL CALIBRATION of CMS.
Tagger and Vacuum Chamber Design. Outline. Design considerations. Stresses and deformations. Mechanical assembly.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Beam Dynamics Tutorial, L. Rivkin, EPFL & PSI, Prague, September 2014 Synchrotron radiation in LHC: spectrum and dynamics The Large Hadron Collider (LHC)
Spontaneous Radiation at LCLS Sven Reiche UCLA - 09/22/04 Sven Reiche UCLA - 09/22/04.
U. Iriso, A. Nosich, and L. Torino Accelerator Division, CELLS May 2014 Beam Size Measurements at ALBA.
Tagger and Vacuum Chamber Design. Outline. Design considerations. Stresses and deformations. Mechanical assembly.
Matching and Synchrotron Light Diagnostics F.Roncarolo, E.Bravin, S.Burger, A.Goldblatt, G.Trad.
Beam Instrumentations: Requirements for Proton and Electron Beams C. Bracco, E. Gschwendtner, B. Goddard, M. Meddahi, A. Petrenko, F. Velotti Acknowledgements:
Electron Spectrometer Progress Report Simon Jolly 19 th October 2012.
Optics and magnetic field calculation for the Hall D Tagger Guangliang Yang Glasgow University.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
SoLID EC Update Zhiwen Zhao 2012/05/22. Beam test update Coverage for PVDIS Road map.
Status Report on Mk.II Pepperpot Simon Jolly Imperial College 13 th June 2007.
Jornadas LIP 2008 – Pedro Ramalhete. 17 m hadron absorber vertex region 8 MWPCs 4 trigger hodoscopes toroidal magnet dipole magnet hadron absorber targets.
Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *
Understanding typical users for this instrument Graduate studentGraduate student –not an X-ray expert but wants to make a spatially resolved measurement;
AWAKE Electron Spectrometer Simon Jolly, Lawrence Deacon, Matthew Wing 28 th January 2015.
Electron Spectrometer Work Package Simon Jolly 19 th May 2014.
SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo.
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
Current Status of Pepperpot Emittance Measurement System Simon Jolly Imperial College FETS Meeting, 22/02/06.
Overview of the GlueX Tagger and Photon Beamline..
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Lecture 9: Inelastic Scattering and Excited States 2/10/2003 Inelastic scattering refers to the process in which energy is transferred to the target,
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
G. Ferioli, R. Jung - LHC-BI Review Workshop November 19&20 LHC Screen Profile Monitors G. Ferioli, R. Jung Introduction BTV LHC layout Monitor set-up.
Matching monitors for SPS and LHC E. Bravin 31 March 2011.
Beam Halo Monitor : Q-bars+SiPMMike Albrow, 26 Aug 2010 A Beam Halo Monitor for the LHC based on Quartz Cherenkov Counters Mike Albrow (Fermilab) Features:
1 Question to the 50GeV group 3GeV からの 54π と 81π 、 6.1π の関係 fast extraction 部の acceptance (81π?) Comments on neutrino beamline optics?
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
James Holloway University College London, London, UK PhD Supervisors: Professor Matthew Wing University College London, London, UK Professor Peter Norreys.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
MEIC Detector and IR Integration Vasiliy Morozov, Charles Hyde, Pawel Nadel-Turonski MEIC Detector and IR Design Mini-Workshop, October 31, 2011.
Shielding review for temporary spectrometer for RUBICON experiment, ATF beamline #2 K. Kusche, M. Fedurin RSC meeting, Jan 20, 2015.
Issues Concerning Different Beam Lines Integration C. Bracco, E. Gschwendtner, B. Goddard, M. Meddahi, A. Petrenko, F. Velotti Acknowledgements: WP3 and.
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Detector / Interaction Region Integration Vasiliy Morozov, Charles Hyde, Pawel Nadel-Turonski Joint CASA/Accelerator and Nuclear Physics MEIC/ELIC Meeting.
Progress of Mk.II Pepperpot: Camera, Scintillator and Data Analysis Simon Jolly Imperial College 24 th January 2007.
Awake electron beam requirements ParameterBaseline Phase 2Range to check Beam Energy16 MeV MeV Energy spread (  ) 0.5 %< 0.5 % ? Bunch Length (
Thomas Roser SPIN 2006 October 3, 2006 A Study of Polarized Proton Acceleration in J-PARC A.U.Luccio, M.Bai, T.Roser Brookhaven National Laboratory, Upton,
Wir schaffen Wissen – heute für morgen PSI, March 2013 Paul Scherrer Institut PSI / DESY / KIT Mini-Workshop on Longitudinal Diagnostics for FELs.
Narrow plasma & electron injection simulations for the AWAKE experiment A. Petrenko, K. Lotov, October 11,
Tagger and Vacuum Chamber Design Jim Kellie Glasgow University.
FETS Ion Source Diagnostics: The Pepperpot
Update on electron spectrometer measurements Introduction Setup, measurements carried out Some raw images Results and conclusions L. Deacon, M. Wing (UCL)
Particle Physics Group Meeting January 4 th – 5 th 2010 Commissioning EMMA, the Worlds First Non Scaling Fixed Field – Alternating Gradient Accelerator.
ODR Diagnostics for Hadron Colliders Tanaji Sen APC.
AWAKE Electron Spectrometer Simon Jolly 6 th November 2013.
Primary Beam Lines for the Project at CERN
Electron Spectrometer Baseline
Pepperpot Emittance Measurements of the FETS Ion Source
Analysis of 14/20 mrad Extraction Line Energy Chicane
Large Booster and Collider Ring
Spectrometer Layout (Isometric View)
Final Focus Synchrotron Radiation
Interaction Region Design Options e+e- Factories Workshop
Variable distance from beam.
Simon Jolly UKNFIC Meeting 25th April 2008
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

AWAKE Electron Spectrometer Design Simon Jolly 4 th September 2012

Spectrometer Specifications Wakefield accelerated electrons ejected colinear with proton beam: need to separate the 2 and measure energy of electron beam only. Must be able to resolve energy spread as well as energy: spectrometer must accept a range of energies, probably 0-5 GeV. Simple conceptual layout: –Dipole mounted at plasma exit separates proton and electron beams. –Scintillator screen 4 m downstream of dipole intercepts electron beam ONLY. –Dispersion gives energy-dependent position spread on screen. –Scintillator imaged by intensified CCD camera viewing upstream face of scintillator screen. 04/09/12Simon Jolly, University College London2

Spectrometer Layout 04/09/12Simon Jolly, University College London3 Dipole separates protons from electrons AND puts energy-dependent spread in beam. Electrons intercepted by scintillator screen, imaged by high speed iCCD camera. Screen nominally 4 m from dipole. Dipole Proton beam Electron beam Screen iCCD Image Low energy High energy iCCD Camera

Browne-Beuchner Spectrometer (Alexey) 04/09/12Simon Jolly, University College London4 C. P. Browne and W. W. Buechner, Rev. Sci. Instrum. 27, 899 (1956). Removes angular convolution from energy measurement, but needs ~3 m magnet for 5 GeV at 1.5 T… Focusing in broad energy range is achieved via pole face curvature.

Spectrometer Beam Trajectories (Alexey) 04/09/12Simon Jolly, University College London5

With Quadrupole Doublet (Alexey) 04/09/12Simon Jolly, University College London6

With Fringe Fields (Alexey) 04/09/12Simon Jolly, University College London7

Proton Microbunches After Plasma (Alexey) 04/09/12Simon Jolly, University College London8 0 m after plasma 2 m after plasma 6 m after plasma Transverse Distributions -60 mm < s < - 40 mm

CERN 1 m Dipole (Edda, Alexey) 04/09/12Simon Jolly, University College London9

AWAKE Spectrometer Layout Edge of scintillator screen is aligned with dipole coils (position will depend on resolution). Screen mounted at 45 degrees to beam axis. Camera is 4m from centre of screen, mounted at 90 degrees to beam axis. Camera shown in horizontal bending plane. Camera can also be mounted vertically, directly above screen, with screen tilted at 45 degrees to vertical as well as 45 degrees to beam axis. Dipole to screen distance remains unchanged (independent of screen- camera orientation). 04/09/12Simon Jolly, University College London10 4 m 1.6 m 1 m Camera Dipole Screen

AWAKE Spectrometer Layout 2 Simon Jolly, University College London 2 m 1.6 m 1 m Camera Dipole Screen 04/09/1211

Layout Questions Do we need 2 dipoles? –Difficult to get good low/high field from single dipole. –Weak dipole (Browne-Buechner?) upstream of strong dipole analyses MeV electrons. –Reduces available longitudinal space, increases complexity: need 2 nd screen & camera + larger vacuum vessel. Can we include quadrupole doublet? –Alexey’s simulations show improvement in energy range on screen with doublet. –Is there enough longitudinal space? How close should screen be to dipole? –Closer gives better range, less effect of emittance, higher light output. –Greater distance improves resolution, requires smaller dipole. –Probably needs to be closer due to low beam intensity, large energy spread. Optimum camera location? –Camera not radiation hard (waiting on specs from manufacturer), so needs to be well shielded ie. far from beamline. –Intensifier enhances low light output from screen (single photon detection) but more light into camera gives better signal-to-noise ie. close to beamline. –Mount camera above beamline? Increases distance from beamline while reducing distance to screen. 04/09/12Simon Jolly, University College London12

Spectrometer Camera 04/09/12Simon Jolly, University College London13 Camera already purchased. Andor iStar 340T iCCD camera: –2048 x 512 total pixels (1850 x 512 active with 25 mm intensifier). –13.5 um pixels. –Gen-2 W-AGT P43 intensifier, gated at 7 ns. –Nikon F-mount lens mount. –16-bit readout, 150 ke - pixel full well. – ameras/istar_iccd_camera/340- intensified-sensor/ ameras/istar_iccd_camera/340- intensified-sensor/ Camera setup: –DAQ and control software. –Data analysis software to give online measurement of witness beam energy spectrum. –Mechanical design of camera support system for tests and installation in SPS tunnel (comes later).

Scintillator Choices Scintillator requirements: –High light output (very low intensity electron beam). –Radiation hard (survive proton beam?). –Vacuum safe (screen inside vacuum vessel). Scintillator choices from 3 different fields: –Accelerators (survive higher current): Al 2 O 3 (“ruby” powder, used in LHC BTV). YAG:Ce (high light output). Quartz (very rad hard, low light output). –Detectors (high light output): CdWO 4 /PbWO 4 /ZnWO 4 (CMS ECal). CsI(Tl) (very high light output, not rad hard). BGO/LYSO (more rad hard for lower light). Plastics (less rad hard, cheap). –Plasma Wakefield (large area): Lanex (large screens, vacuum safe?) P43/P46/P47 phosphors (x-ray phosphors). Need highest number of photons per solid angle to give maximum screen-to- camera distance. Manual lens probably means no zoom (prime lens), so resolution fixed by mechanical layout. 04/09/12Simon Jolly, University College London14

Conclusions Baseline design is evolving rapidly: this is good! Looks like optimum will be 45 degree screen close to dipole: –Alexey’s simulations show energies already well separated at dipole exit. –Get as close to dipole exit as possible while still imaging whole screen (camera view not obscured by dipole yoke). –Light path needs to be absolutely light tight (light from plasma exit?) but not necessarily vacuum tight. Need input on scintillators to know what possibilities are: –Why is Lanex never used in HEP? –Need specs on light output to set maximum camera-to- screen distance. Spectrometer design will probably evolve from all constraints ie. beamline space, radiation, vacuum vessel, then optimised within those constraints. 04/09/12Simon Jolly, University College London15