Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron.

Slides:



Advertisements
Similar presentations
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Sampling and Measurement for Volatile Organic Compounds
SPOTLIGHT ON THE LELAND LEGACY ® PUMP FROM THE LELAND LEGACY PUMP Provides answers to particulate sampling problems. High flow rates + 24-hr run times.
Copyright, 2006: Invisible Service Technicians, LLC Invisible Service Technicians, LLC Invisible Service Technician Monitor Activation Process: IST MaintSelectionV3.php.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Marketing NeSSI™ Globally What’s the Plan?. Issues There are periodic requests for NeSSI™ information from the “press” Should we provide directed mailings.
2025 Partisol Sequential Sampler
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Finding That Elusive Pot of Gold or Networking Your Shelter Rebecca Peltzer & Jennifer Bradley, Polk County – Air Quality Steve Drevik, Agilaire.
How long will the test last?
Air Quality Monitor Project Jeff Wojtusik Marc Koehler Danielle Howe Matt Knauf Remberto Mendoza Gutierrez Arielle Mizov.
AccuMax Multi-Point Injection Mechanics
Air Pollution Chapter 4.
Unit 11: Calibrating Instruments
Ozone and Ozone Monitoring 2015 National Tribal Forum Glenn Gehring, Technology Specialist III Tribal Air Monitoring Support (TAMS) Center Institute for.
Lesson 5 What devices do we use to measure radon?.
Teledyne Analytical Instruments
RPC «REGMIK» 15582, Ukraine, Chernihiv region, Rivnopillya, Gagarin Street, 2B phone.: +38 (0462) , , , , +38 (050)
Continuous Ambient Particulate Monitors A Review of Current Technologies by Michael Corvese, Product Manager Thermo Electron Corporation Air Quality Instruments.
E VERY L IFE H AS A P URPOSE… Chillgard ® RT Refrigerant Monitors.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Monitoring Station Location and Siting Initially on a residential porch at Marina Towers, aligned with the Mirant Potomac River Generating Station (PRGS)
Introduction to BGI Instruments
High Sensitivity Smoke Detection
Met One BAM-1020 Operation Key Points
Calibration Savvy. Calibration and Conformance  Calibration: Check a measurement against a known universally recognized standard to determine any deviation.
Continuous Particulate Training Workshop
1 Dec. 8, 1997 LEADS Quality Assurance Summary Robert Brewer (512) Monitoring Operations Division Network QA Manager.
Sampling and Measurement for Respirable Particulates.
Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.
Continuous Particulate Monitoring Using Light Scatter Photometers.
Laser- based smoke detectors
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
1 β Attenuation Method PM10/2.5 Automated Dichotomous Monitor SPM-613D β Attenuation Method PM10/2.5 Automated Dichotomous Monitor Model SPM-613D ■SPM.
Quality Control – Part II Tim Hanley EPA Office of Air Quality Planning and Standards.
CARB Continuous PM 2.5 Monitoring Activity (BAM’s) Reggie Smith California Air Resources Board.
Measuring Particle Pollution ITEP Air Quality Training Kodiak 2015
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
The Theory of Near Light Scatter
Carbon Dioxide Monitoring
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
CUE – Make Any Pump an E-Pump
1 Greenhouse Gas Monitoring Network Update Pat Vaca, Air Pollution Specialist
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
Assessing Ambient Air Quality James Payne Morongo Band of Mission Indians.
PRINCIPLE OF OPERATION
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Hygrometry Part 2.
Office of Research and Development National Risk Management Research Laboratory, Air Pollution Prevention and Control Division Photo image area measures.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
Environment Canada, ETC, Ottawa
Control System for a four component Gas Mixing Unit Suvendu Nath Bose, Satyajit Saha, Sudeb Bhattacharya, Saha Institute of Nuclear Physics, Kolkata
Introduction of Laser Evaluating Technology to Street Leak Surveys Ashraf Salha APA Group Gas Speak Colloquium September 2015.
Unit 11: Calibrating Instruments
SPOTLIGHT ON THE LELAND LEGACY® PUMP FROM
Kessler-Ellis Products
How SCADA Systems Work?.
Particle Physics and Particle Counting for IH&S and IAQ
F&J SPECIALTY PRODUCTS, INC.
August 23, 2000 R.N. Dubois Dow Chemical
The New RAPID TPM A NEW PLATFORM FOR TURBO PETROL ENGINES Leading name in the world of the additional module applied to Turbo Diesel engines for over.
Introduction to Tisch Instruments
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Turbidity - “A Quantum Leap in Technology” Southwest Section AWWA
Environmental Catalogue Introduction
Presentation transcript:

Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron

2 Environmental Instruments Division Air Quality Instruments – formerly Thermo Andersen, Thermo Environmental Instruments, Thermo Eberline,Thermo MIE and EPM Environmental

3 Continuous Particulate Monitors FH 62 C14 Series Continuous Ambient Particulate Monitor Model 5012 Multi Angle Absorption Photometer DataRAM TM Portable Particle Sizing Aerosol Monitor

4 Designation Status FH 62 C14 Series Continuous Ambient Particulate Monitor US EPA Automated Equivalent PM 10 Method EQPM CARB California Approved Sampler (CAS) for PM 10 and PM 2.5 Model 5012 Multi Angle Absorption Photometer Instrument not designated

5 Series FH 62 C14 Principle of Operation Thermo Electron FH 62 C14 Beta

6 Series FH 62 C14 Principle of Operation (cont.)

7 C14 uses Beta Attenuation through known area on filter tape to continuously detect mass of deposited ambient particles Continuous detection of Beta Attenuation is proportional to increased mass C14 also measures Alpha particle emissions to exclude background interferences from radon gas Series FH 62 C14 Principle of Operation (cont.)

8 Clean filter spot introduced by automatic filter change every 24 hours Or sooner if mass on filter exceeds 1500  g since last filter change Or if flow rate is reduced by 5% particle deposition Ambient air is drawn through a size-selective inlet TSP, PM 10, PM 2.5 Series FH 62 C14 Principle of Operation (cont.)

9 Ambient particles are drawn down heated sample tube Decrease RH of sample stream Reduce particle bound water Reduces positive artifact measurement of condensation on filter tape Sample tube is curved to avoid abrupt turns and points for premature collection Collection of particles on filter tape and measured continuously Series FH 62 C14 Principle of Operation (cont.)

10 Series FH 62 C14 Principle of Operation (cont.) 1: Proportional Detector 2: Sample Chamber with filter tape 3: Vacuum Chamber 4: C14 Beta Source

11 Beta Attenuation Particulate Monitor $12,999 Calibration Mass Foil Kit $ 1,185 Financing options include Leasing (24-60 months and Rental 6-18 months) through Thermo Capital Customized monthly payments, lease terms, payment options and deferred programs Simplified payments-equipment, service, and supplies all in one Series FH 62 C14 – Cost

12 Heated Sampling tube 1 or 3 meters $ 1,326 FH108C14 Outdoor Weather Enclosure $ 2,200 Not necessary if used in shelter PCB – Analog I / O Expansion$ 1,238 Delta Cal or Tri Cal (BGI) Drucks pressure gauge (DPI 705) Series FH 62 C14 – Additional Equipment

13 Downloading Capabilities Instrument display provides Concentration and mass on continuous basis Flow rate, temperature, pressure readings Run, status, error codes

14 Downloading Capabilities (cont.) Input/output available 2 digital data ports via laptop, PC or modem 1 year digital data storage Control instrument remotely 1 standard analog output fully configurable Optionally 4 analog outputs Output standard either voltage or current output Output can be sent to any data logger

15 Thermo Electron Support Atlanta(Smyrna), GA 2 Service Technicians Sales and Technical Support 800 Number ( ) Franklin, MA Service Support Manufacturing & spare parts Technical Support 800 Number ( ) Regional Sales Managers-18 Local Manufacturer’s Representatives-24

16 Thermo Electron Support Fifteen years experience supporting existing Beta Attenuation units Free phone & support for setup, maintenance and troubleshooting Component replacement Recalibration services Cleaning services for Measurement chamber

17 Calibration Procedure and Frequency Mass Foil Calibration Performed once a year or after measurement chamber has been cleaned; procedure requires minutes Air Flow Calibration Performed once a year; requires NIST traceable volumetric flow device, Before Air Flow is calibrated, strongly recommended that you calibrate temperature sensors and barometric pressure sensors

18 Verification Stable operation of instrument is verified and monitored by observing Error Status on Main Menu Global Error Sum Status reports verification of following parameters Data and program memory Particulate sampling and measurement system Air flow rate measurement system Air flow rate regulation unit External sample tube heater Temperature measurements Each Global parameter is further divided into 8 fields of Detailed Error Status Codes

19 Maintenance IntervalMaintenance Procedure 5-20 daysClean PM-2.5 impactor or cyclone 1-3 monthsCheck air flow 3 monthsClean PM-10 inlet 6-9 monthsCheck/change filter tape 12 monthsMass calibration with foil set 12 monthsAir flow calibration 12 monthsReplace pump carbon vanes 2 yearsClean measurement chamber (by Thermo service)

20 Aerosol Monitoring – Black Carbon Model 5012 MAAP Continuous Black Carbon Monitor Thermo Electron Model 5012 MAAP

21 Aerosol Monitoring – Black Carbon (cont.) Principal of Operation

22 Principle of Operation Principal of Operation Aethelometer MAAP Transmittance Only Forward Scattering, Back Scattering, and Transmittance Led, 670nm

23 Principle of Operation (cont.) Model 5012 MAAP Continuous Black Carbon Monitor 1: Back Scattering detection 2: Sample Chamber 3: Vacuum Chamber 4: Forward Scattering and Transmittance

24 Aerosol Monitoring – Black Carbon (cont.) Model 5012 MAAP Continuous Black Carbon Monitor Continuously determined by simultaneous measurement of optical absorption and scattering of light particles collected on filter tape

25 Model 5012 Black Carbon Monitor $ 16,300 Financing options include Leasing (24-60 months and Rental 6-18 months) through Thermo Capital Customized monthly payments, lease terms, payment options and deferred programs Simplified payments-equipment, service, and supplies all in one Model 5012 MAAP – Cost

26 FH108C14 Outdoor Weather Enclosure $ 2,200 Not necessary if used in shelter PCB – Analog I / O Expansion$ 1,238 Delta Cal or Tri Cal (BGI) Drucks pressure gauge (DPI 705) Model 5012 MAAP – Additional Equipment

27 Downloading Capabilities Instrument display provides Concentration and mass on continuous basis Flow rate, temperature, pressure readings Run, status, error codes

28 Downloading Capabilities (cont.) Input/output available 2 digital data ports via laptop, PC or modem 1 year digital data storage Control instrument remotely 1 standard analog output fully configurable Optionally 4 analog outputs Output standard either voltage or current output Output can be sent to any data logger

29 Thermo Electron Support Atlanta(Smyrna), GA 2 Service Technicians Sales and Technical Support 800 Number ( ) Franklin, MA Service Support Manufacturing & spare parts Technical Support 800 Number ( ) Regional Sales Managers-18 Local Manufacturer’s Representatives-24

30 Calibration Procedures and Frequency Black Carbon Mass Calibration Performed once a year; scattering cross section determined by independent measurement or by comparing it to basic method. Default value based on research done by Dr. Andreas Petzold Air Flow Rate Calibration Performed once a year; requires NIST traceable volumetric flow device Before Air Flow is calibrated, strongly recommended that you calibrate temperature sensors and barometric pressure sensors

31 Calibration Default Standard

32 Calibration (cont.) Required Equipment

33 Verification Stable operation of instrument is verified and monitored by observing Error Status on Main Menu Global Error Sum Status reports verification of the following parameters Data and program memory Mechanical components Air flow regulation Pressure sensors Photo detectors Temperature measurements Each Global parameter is further divided into 8 fields of Detailed Error Status Codes

34 Maintenance IntervalMaintenance Procedure 5-20 daysClean PM-2.5 impactor or cyclone 14 daysCheck air flow 1 monthClean PM-10 inlet 3 monthsTemperature sensor audit 3 monthsAir flow audit 3 monthsPressure sensor audit 6-9 monthsCheck/change filter tape 12 monthsReplace pump carbon vanes 12 monthsClean optics chamber (by Thermo service)

35