MIS 1.5 Training. Day 1 Section 1 Overview and Features (30 min) Section 2 Hardware Overview (1 hour) Section 3 Internal Cabling (1 hour) Lab 1 Show and.

Slides:



Advertisements
Similar presentations
PowerEdge T20 Customer Presentation. Product overview Customer benefits Use cases Summary PowerEdge T20 Overview 2 PowerEdge T20 mini tower server.
Advertisements

PowerEdge T20 Channel NDA presentation Dell Confidential – NDA Required.
Supermicro © 2009Confidential 06/01/2009 Supermicro GPU Server Solutions SYS-7046T-GRF SYS-6016T-GF-TM2 SYS-6016T-GF-TC2 SYS-6016T-GF SYS-6016T-XF.
Confidential Prepared by: System Sales PM Version: 1.0 Lean Design with Luxury Performance.
© 2010 Cisco and/or its affiliates. All rights reserved. 1 Microsoft Exchange Server Ready UCS Data Center & Virtualizacion Cisco Latin America Valid through.
Premio Predator G2 Workstation Training
SGI ® Company Proprietary SGI ® Modular InfiniteStorage Sales Deck – V4 – Feb 2013 An evolutionary new compute & storage platform exclusive to SGI.
Page 1 Dorado 400 Series Server Club Page 2 First member of the Dorado family based on the Next Generation architecture Employs Intel 64 Xeon Dual.
IT Essentials: PC Hardware and Software 1 Chapter 3 Assembling a Computer.
SGI Confidential Shelf Hardware. SGI Confidential Shelf Front View Canister Status LEDs Canister 0Canister 7 Canister Position Number Canister.
Premio 845D and 845MD Training Premio S650 Desktop Product Training By Calvin Chen Technical Director.
Linux Clustering A way to supercomputing. What is Cluster? A group of individual computers bundled together using hardware and software in order to make.
Introduction to Information Technology: Your Digital World © 2013 The McGraw-Hill Companies, Inc. All rights reserved.Using Information Technology, 10e©
SGI Confidential Application Processor. SGI Confidential Application Processor Overview Application Field Replaceable Units The Application.
MIS 1.5 Hardware Overview.
EMC DATA DOMAIN DD640, DD620, AND DD160
Supermicro © 2009 GPU Solutions Universal I/O Double-Sided Datacenter Optimized Twin Architecture SuperBlade ® Storage Confidential Mainstream Server.
HP INNOVATION DELIVERING VALUE TO BUSINESS Simon Molloy Market Development Manager.
Intel  modular server building blocks ( built on Intel  Multi-Flex Technology ) Intel  modular server building blocks ( built on Intel  Multi-Flex.
LOGO. Types of System Boards  Nonintegrated System Board  Nonintegrated system boards can be easily identified because each expansion slot is usually.
5.3 HS23 Blade Server. The HS23 blade server is a dual CPU socket blade running Intel´s new Xeon® processor, the E5-2600, and is the first IBM BladeCenter.
RAID Controllers Nick Crampton Tim Hays Richard Rogers.
COMPUTER A random company inc. Malachi Andersen. Goals  Build a computer with a budget of $1,500 - $1,
Module 9 PS-M4110 Overview <Place supporting graphic here>
Supermicro © 2009 GPU Solutions Universal I/O Double-Sided Datacenter Optimized Twin Architecture SuperBlade ® Storage Present by Edward Li Server dept.
Cluster computing facility for CMS simulation work at NPD-BARC Raman Sehgal.
A+ Guide to Managing and Maintaining Your PC Fifth Edition Chapter 5 The Motherboard.
I T Essentials I Chapter 3 JEOPARDY.
Henry Brady Computer Components Unit 2 – Computer Systems.
Hardware Overview Iomega Network Storage LENOVO | EMC CONFIDENTIAL. ALL RIGHTS RESERVED. Storage for SMB and Distributed Enterprise PX SERIES.
Hardware Case that houses the computer Monitor Keyboard and Mouse Disk Drives – floppy disk, hard disk, CD Motherboard Power Supply (PSU) Speakers Ports.
A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, Sixth Edition Chapter 9, Part 11 Satisfying Customer Needs.
Strata IT Training Chapter 8 Upgrading Hardware. When to Upgrade Poor performance Out of disk space Application(s) fail to load –Need more RAM System.
Introducing Snap Server™ 700i Series. 2 Introducing the Snap Server 700i series Hardware −iSCSI storage appliances with mid-market features −1U 19” rack-mount.
The PC The PC is a standard computing platform, built around a EISA bus (1988) –IBM compatible –“Intel Architecture” from Intel or AMD or other companies.
Chipset Introduction The chipset is commonly used to refer to a set of specialized chips on a computer's motherboard or.
By: Joshua chambers INTRODUCTIONINTRODUCTION What your computer can do depends upon two things: the hardware your computer has, and the software that.
How Computers Work The Four Basic Operations The Boot Process
A+ Guide to Managing and Maintaining your PC, 6e Chapter 1 Introducing Hardware v0.95.
Confidential Prepared by: System Sales PM Version: 1.0 Eco-Focused and Efficient 1U Server.
ISS Interlock Demand Planning Update
By: Dorian Gobert. In 1998, the Gateway G6-450 was "top of the line", the fastest computer Gateway offered. Compared it to the eMachines ET in.
Weekly Report By: Devin Trejo Week of June 21, 2015-> June 28, 2015.
 The End to the Means › (According to IBM ) › 03.ibm.com/innovation/us/thesmartercity/in dex_flash.html?cmp=blank&cm=v&csr=chap ter_edu&cr=youtube&ct=usbrv111&cn=agus.
Sugon I840-G25 Server Pre-sale training v1.0 Product Center Computing creates future.
Surveon Enterprise Solution with Milestone Introduction Sales & Marketing Department.
SA1 operational policy training, Athens 20-21/01/05 Presentation of the HG Node “Isabella” and operational experience Antonis Zissimos Member of ICCS administration.
Henry Brady Computer Components Unit 2 – Computer Systems.
Intel Corporation LGA775 Socket Options Jim Rimpleman.
Dell PowerEdge Blade Server PDVSA Jun-05
Huawei Server Competitive Positioning
1062m0656 between 10692m2192 DS/ICI/CIF EqualLogic PS6510E
SGI Rackable C2108-GP5 “Arcadia” Server
CN1260 Client Operating System Kemtis Kunanuraksapong MSIS with Distinction MCT, MCITP, MCTS, MCDST, MCP, A+
E2800 Marco Deveronico All Flash or Hybrid system
EonStor DS 1000.
Managing HP Enterprise Virtual Array
Chapter Objectives In this chapter, you will learn:
SYS-7088B-TR4FT Quick View Front View - DDR4:SYS-7088B-TR4FT (15 PCI-E 3.0 default) Depth:28.87” (733 mm) 8 CPU Modules: P1 to P8 P1 P2 P3 P4 P5 P6 P7.
PCI-E 1x Slot - Single slot - In the PCIe 1
Good idea? Why would you want to upgrade?
A. PCI Slot - This board has 2 PCI slots
What is missing in the title?
Unit 2 Computer Systems HND in Computing and Systems Development
Design Package Contribution for Project Olympus US1-EPYC
Cisco MDS 9124e Fabric Switch for HP c-Class BladeSystem
Brief Description of SNC-60x0-488F
QCT Rackgo X Yosemite V2 2018/08/22.
What’s in the Box?.
Power couple. Dell EMC servers powered by Intel® Xeon® processors and running Windows Server* 2016, ready to securely handle dynamic business workloads.
Presentation transcript:

MIS 1.5 Training

Day 1 Section 1 Overview and Features (30 min) Section 2 Hardware Overview (1 hour) Section 3 Internal Cabling (1 hour) Lab 1 Show and tell (30 min) Lunch Section 4 System Interfaces (1hour 30 min) Lab 2 IPMI, RMM4,(45 min)

Day 2 Section 5 Zoning (2 Hours) Lab 3 Zoning (1 Hour) Lunch Section 6 MegaRAID (1 hour 30 Min) Section 7 lsiutil (30 min) Lab 4 MegaRAID, lsiutil (1 hour) Section 7 Fan Baseboard (45 Min) Lab 4 Fan Baseboard (30 Min)

Day 3 Section 10 BIOS/Firmware Overview (Downloading and flashing) (30 min) Lab 5 Flashing BIOS (30 min) Section 11 Replacing Storbrick (video) (30 min) Lab 6 Replacing Storbrick and flashing firmware Section 12 Replacing Fan Base Video Lab 12 Replacing and flashing Fan Base Lunch Section 13 Replacing disks and flashing disks Lab 6 Replacing disk Lab 7 Replacing fan Lab 8 Replacing Power Supply

Day 4 Section 8 FRU/CRU parts (45 Min) Section 9 BIOS/Firmware Download (30 Min) Section 14 Troubleshooting

OVERVIEW AND FEATURES Day 1 Section 1

Covered in this section What is the MIS 1.5 What are the differences from MIS 1.0

What is the MIS 1.5 The MIS Server Platform features: Up to 2 server modules per platform. Two Intel® Xeon® E series processors per server motherboard, S2600JF family. Intel Turbo Boost Technology 2.0 that automatically allows processor cores to run faster than the base operating frequency, if the cores are operating below power, current, and temperature specification limits (< 35ºC ambient). Dual GbE networking onboard. Up to 8 DDR3 DIMMs (new: 8 GB, 16 GB, or 32 GB) for a single-server motherboard configuration, and up to 16 DIMMs for a dual-server motherboard configuration. Up to 6 HBAs for single servers—these can be full-height (4.25") and half-depth (3.375"), up to 4 externally facing and/or up to 4 internally facing (total external and internal not to exceed 6). For single-server platforms only, optional 4 port1 8Gb Fibre Channel PCIe cards. Up to 4 HBAs per server module (for up to a total of 8 across both server modules) in a dual server system—these can be half-height (2.12"), half-depth (3.375"), 2 internal max and/or a maximum of 2 external. Unique Battery Back-Up PCIe technology allows the optional addition of BBUs without the consumption of any of the available PCIe slots. Two boot drive modules per server, with up to two boot drives per module.

What are the differences with MIS 1.0 Midplanes and interposers replace the need for interior cables. Fewer cables maximize air flow through the unit. Higher capacity fan modules for greater cooling capability Dual server platforms with both server modules installed features hot- swappable server modules for greatly reduced service times. Support for larger capacity drives, higher memory, and faster processor speeds.

HARDWARE OVERVIEW Day 1 Section 2

Covered in this section Front and rear exterior view and Front panel Server Modules StorBrick Fan Baseboard (Fan Base)

INTERNAL CABLING Day 1 Section 3

Covered in this section Manuals HBA to SAS Interposer SAS Interposer to SAS Midplane

Cabling Diagrams are on Servinfo on the MIS 1.5 Page

HBA to SAS Interposers