GSC: Standardization Advancing Global Communications Resolution GSC-10/05: (GRSC) Facilitating Liaison in Relation to Measurement Methodologies for Assessing.

Slides:



Advertisements
Similar presentations
GSC: Standardization Advancing Global Communications For Information and Discussion Standardization development in the IEEE is carried out under the oversight.
Advertisements

GSC: Standardization Advancing Global Communications ITU-R Developments on UWB B. Gracie, Chairman, RAG/ITU-R SOURCE:ITU-R TITLE:ITU-R Developments on.
December 2005 EuP Directive : A Framework for setting eco-design requirements for energy-using products European Commission.
Update on EMF DG Sanco Health Information Unit Brussels, 27 March 2006.
ITU-T Technical Session on EMF
ITU-T SG5 activities on EMF
International Telecommunication Union Seminar on Impact of Electromagnetic Field Emissions Kampala, Uganda, 3-5 September 2003 ITU-T activities in EMF.
Paolo Gemma, Senior Expert, Huawei
OSHA Requirements for Tower Construction Related to RF Radiation
International Telecommunication Union Committed to connecting the world 4 th ITU Green Standards Week Mike Wood & Jack Rowley EMF Technical Group Leaders,
Safety Assessment for Electric Utility Workers Exposed to ELF-EMF: Literature Review Tarek K Abdel-Galil Ibrahim O Habiballah 27 Nov
Safety & Safety Documentation 2 3 Safety in three Questions Why ? Providing a safe workplace is a legal and moral obligation on every undertaking, and.
Protection Against Occupational Exposure
Overview of ITU-T's activities on EMF
Lima, Peru, 10 December 2013 Overview of ITU-T Activities on Human Exposure to Electromagnetic Fields (EMFs) Mike Wood, General Manager, Telstra EME Management.
Codex Guidelines for the Application of HACCP
Cristina Bueti Advisor, ITU-T Study Group 5
STFC SHE Group Corporate Services This code should be read by: All STFC staff, tenants who are responsible for equipment or facilities generating strong.
DTR/H&D Joint Venture1 Radio Frequency Exposure and Compliance Issues for a Shortwave May 2008 Matthew W. Folkert, MSEEE Stephen S. Lockwood, P.E. dTR/H&D.
27/08/2015 Intelligent Transport Services ETSI activities 1GSC-9, Seoul SOURCE:ETSI (ERM TG#37) TITLE:Intelligent Transport Services – ETSI activities.
Exposure to risks arising from electromagnetic fields Chris Marshman York EMC Services Ltd University of York.
1 INTERNATIONAL TELECOMMUNICATION UNION Telecommunications Development Bureau (BDT) REGIONAL OFFICE FOR AFRICA EMF ENVIRONMENTAL CHARACTERIZATION OVERVIEW.
GSC: Standardization Advancing Global Communications Review of GRSC3 meeting SOURCE:ETSI TITLE:Review of GRSC3 AGENDA ITEM:GRSC4 3 CONTACT:Karl Heinz Rosenbrock.
1 Framework Programme 7 Guide for Applicants
13/09/2015 RESOLUTION GSC-8/4: Facilitating Liaison in Relation to Measurement Methodologies for Assessing Human Exposure to RF Energy ETSI TC Safety Working.
1 EMF ASSESSMENT BY MEASUREMENT (IVORIAN CASE ) GUY-MICHEL KOUAKOU Head of standardization service VICE-CHAIR OF STUDY GROUP 5.
Nairobi, Kenya, 26 – 27July 2010 Revue on RF Safety Reference Levels and Measurement protocols Christian BLANCHARD CEO Planet Network International ITU-T.
Halifax, 31 Oct – 3 Nov 2011ICT Accessibility For All Wireless Chargers Gabrielle Owen ETSI TC ERM Chair Document No: GSC16-PLEN-38r1 Source: ETSI Contact:
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE Day ASSESSMENT OF HEALTH RISKS.
10/10/2015 GSC8 Resolutions 11 Resolutions Joint 3, GRSC 5, GTSC 1, IPR 1, UWG 1 1GSC-9, Seoul SOURCE:TTA TITLE:GSC8 Resolutions AGENDA ITEM:Opening Plenary.
European Commission Rita L’ABBATE Legal aspects linked to internal market DG Enterprise and Industry MARKET SURVEILLANCE COMMUNITY FRAMEWORK UNECE “MARS”
International Telecommunication Union Committed to connecting the world 4 th ITU Green Standards Week Cristina Bueti Adviser of ITU-T Study Group 5 With.
Two of the most important pieces of the health and safety legislation affecting educational establishments across the UK are the Health and Safety at.
1 PED: equivalent overall level of safety PED Annex 1, clause 7: The following provision apply as a general rule. However, where they are not applied,
Characterizing evidence in EMF risk assessment, Berlin, 4-5 May 2006 The WHO International EMF Project Dr E. van Deventer Radiation and Environmental Health.
EMF STANDARDIZATION IN ITU
Committed to connecting the world With ICTs everywhere, how safe is EMF? Guy-Michel KOUAKOU Chairman of Study Group 5 Regional Group for Africa (SG5 RG-AFR)
DOCUMENT #:GSC15-GRSC8-14 FOR:Presentation SOURCE:Radio Microphone Task Force AGENDA ITEM:GRSC8 7.2 CONTACT(S):Brian Copsey, Task Force Convenor Radio.
Support for the Modernisation of the Mongolian Standardisation system – EuropeAid/134305/C/SER/MN Training on standardisation Support to the Modernisation.
Management System Part II: Inventory of Radiation Sources – Regulatory Authority Information System (RAIS)
16/02/2016 RESOLUTION GSC-8/4: Measurement Uncertainties & Methodologies Update on ETSI Progress 1GSC-9, Seoul SOURCE:ETSI TITLE:Measurement Uncertainties.
Committed to Connecting the World March 2011 Geneva, March 2011 Presentation of the Recommendation ITU-T K 100: Presentation of the Recommendation.
05/03/2016 RESOLUTION GSC-8/5: Radio Microphones the elaboration of a single specification for radio microphone products that could be used on a global.
UNCERTAINTY OF MEASUREMENT Andrew Pascall Technical Director Integral Laboratories (Pty) Ltd
Doc.: IEEE /0958r0 Submission September 2005 Knut Evensen, Q-Free ASASlide 1 ETSI-TG37-liaison-report-september-2005 Notice: This document has.
Jeju, 13 – 16 May 2013Standards for Shared ICT TTA WPT activities & Proposal of revised resolution Dr. Hyeonwoo, LEE Chairman of TTA PG709, TTA Document.
BMS4667 Laboratory Leadership and Management Dr. David Ricketts.
Jeju, 13 – 16 May 2013Standards for Shared ICT Smart Grids activities in ETSI Presenter: Adrian Scrase ETSI Chief Technical Officer (CTO) Document No:
Risk Assessment: A Practical Guide to Assessing Operational Risk
GSC IMT Task Force Report Kohei SATOH ARIB DOCUMENT #:GSC13-PLEN-64r1 FOR:Presentation SOURCE:Kohei Satoh (ARIB) AGENDA ITEM:GRSC (7); Plenary (6.1) CONTACT(S):Kohei.
A Global Approach to EMF Management and Standards Mike Wood Vice Chairman, ITU-T SG5, WP2 11th Symposium on ICT, Environment and Climate Change 21 April.
GSC Global Standards Collaboration GSC#10 28 August – 2 September 2005 Sophia Antipolis, France 1 RF Exposure & Measurement uncertainties Presented by.
Standardization of non-ionizing radiation in the Nordic countries
RESOLUTION GSC-8/5: Radio Microphones
پرتوهای غیریونساز دکتر میرشهرام حسینی پناه
GRSC Radio Microphone Task Force Report
ASSESSMENT OF HEALTH RISKS
Reconfigurable Radio Systems Activities in ETSI
Gabrielle Owen ETSI TC ERM Chair
EMF Update From ETSI TC Safety DOCUMENT #: GSC13-GRSC6-06 FOR:
GSC-10 Resolutions Recap
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE
GSC: Standardization Advancing Global Communications
GSC: Standardization Advancing Global Communications
2.1. Monitoring of products placed on the market To verify the products comply with applicable directives EC declaration of conformity and technical.
The ETSI Standardisation Process
Status report from ITU-R WP 5A on ITS activities
GSC: Standardization Advancing Global Communications
The Control of Electromagnetic Fields at Work Regulations 2016
NATE Tower Site Hazard Recognition Guide
Presentation transcript:

GSC: Standardization Advancing Global Communications Resolution GSC-10/05: (GRSC) Facilitating Liaison in Relation to Measurement Methodologies for Assessing Human Exposure to RF Energy Update SOURCE:ETSI TC Safety TITLE: AGENDA ITEM: CONTACT:Brian Copsey GSC11/ (06)

GSC: Standardization Advancing Global Communications Physical Agents Directive Physical Agents Directive (part 18) 2004/04/EC the total EMF exposure within a work place both from the equipment under the control of the employer within that workplace and EMF contributions outside that workplace. i.e. transmitters on adjacent buildings. –Responsibility now lies with the employer.

GSC: Standardization Advancing Global Communications ETSI Contribution Whilst joint CENELEC- ETSI working groups are producing the standards for the Commission mandate, ETSI ERM TG27 had been working on : EG Guide to the methods of measurement of Radio Frequency (RF) fields

GSC: Standardization Advancing Global Communications EG This ETSI Guide is dedicated to the memory of Gerald H David OBE, founder and chairman of the Radio Site Engineering Task Group. His wise counsel and professional approach resulted in a number of practical standards being published to the benefit of the radio community and the wider engineering field. The document is a guide to practical methods of measurement that can be used for the assessment of the radiated RF fields at radio sites and other locations where radio signals are encountered.

GSC: Standardization Advancing Global Communications EG The guide is the first ETSI document to cover the practical measurement of a multi use radio site, and compares a range of probes measuring the same EMF field

GSC: Standardization Advancing Global Communications EG The results of the tests indicated a high degree of confidence using 3 different manufacturers equipment, which gave results where the differences were not significant for radiated RF field measurements and therefore could be used in the assessment of locations at which it is necessary to measure the presence of RF fields at specific levels. It is important to note that the tests carried out only involved individual frequencies. Further work is needed to determine the situation in a multi-frequency environment.

GSC: Standardization Advancing Global Communications EG The issues of multi frequency measurements and calibration are the subject of ongoing work by TG27 in collaboration with the UK National Physics Laboratory

GSC: Standardization Advancing Global Communications EG The Site Measured

GSC: Standardization Advancing Global Communications Towers on Site

GSC: Standardization Advancing Global Communications Conclusion –The measured results have been related to current standards relating to human exposure to electromagnetic fields. Specifically: –ICNIRP International Committee on Non-Ionizing Radiation Protection; –Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic and Electromagnetic Fields (up to 300 GHz). –From the tables in the guide it can be seen that the maximum signal level recorded is 40% of the ICNIRP reference level for general public exposure. –It can thus be stated that the site is compliant with current RF hazard regulations.

GSC: Standardization Advancing Global Communications CENELEC-ETSI Joint WP4 Documents produced under the mandate are probably for the first time in EMF standards work aimed at the employer or other non technical personal. The Standard draws together existing Standards, guides and other documents with flow charts and tables to lead the reader through the process.

GSC: Standardization Advancing Global Communications Zoning This describes a simple administrative procedure that employers may wish to consider in order to define different areas in their workplace. These are not intended to be strict or “hard” boundaries corresponding to the exact locations that different exposure levels might be exceeded. Instead they might correspond to, for example, existing areas of a workplace. For example, a particular building or area might contain equipment that gives rise to exposures greater than public levels, even though those levels are not exceeded in most of the building or area. The employer may choose, for reasons of convenience, that access to that whole building or area should be restricted to certain people (eg excludes visiting members of the public) or that access is associated with information about likely EMF levels. Various zones are defined, but whether and where the exact zone boundaries are decided is a matter for the individual employer. What actions (if any) are to be taken at zone boundaries also is a matter for the employer. –Workplace zones A Zone 0 workplace is one in which all exposure levels are complying with the relevant general public limits. In Zone 1, exposures may be greater than the general public limit but will be compliant with the occupational exposure limit. In Zone 2, exposures may be greater than the occupational exposure limit. If access is possible to Zone 2, then remedial measures to reduce exposure or to restrict or limit access should be taken.

GSC: Standardization Advancing Global Communications

Assessment In assessing the workplace the employer is encouraged to use the following flow chart. Table 1 assists the process by a list of common devices: – Not considered to produce EMF over the limits, or –Where further investigation is necessary.

GSC: Standardization Advancing Global Communications Action Values met ? Specific workplace standard? In compliance With table 1? Exposure Limits Met ? Assessment against Action Values (clause 8) Assessment against Exposure Limits (Clause 9) Measures [Clause 10] Assessment via that standard End of assessment See annexe B Start of assessment Procedures from other (basic, generic, product) standards No Yes

GSC: Standardization Advancing Global Communications Future Work continues in various committees which will be either referenced or included in the final Standard.