Diagnostics for Medical Accelerators

Slides:



Advertisements
Similar presentations
Lyon 2005 DIPAC Lyon th DIPAC Lyon June 2005Ulrich Raich CERN AB/BDI Instrumentation in small, low energy machines Ulrich Raich CERN AB-BDI.
Advertisements

Experience, Expertise and a Commitment to Excellence™
MICE TARGET OPERATION C. Booth, P. Hodgson, R. Nicholson, P. J. Smith, Dept. of Physics & Astronomy University of Sheffield, England.
R Scrivens, CERN, ABI Workshop, 12/2008 The Feschenko Bunch Shape Monitor User experience at CERN Developed by INR, Troitsk. High resolution bunch shape.
Simona Giordanengo Torino January Study and development of the Dose Delivery System for the National Center of Oncological Hadrontherapy (CNAO)
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Stability Workshop April , 2007 NSLS-II Electrical Systems G. Ganetis NSLS-II Electrical Systems NSLS-II.
A pixel chamber as beam monitor for IMRT S. Belletti 4, A.Boriano 6, F.Bourhaleb 5,7, R. Cirio 6, M. Donetti 5,6, B. Ghedi 4, E. Madon 2, F. Marchetto.
PAMELA Contact Author: CONFORM is an RCUK-funded Basic Technology Programme PAMELA: Concepts Particle Accelerator for MEdicaL Applications K.Peach(JAI,
Performances of a pixel ionization chamber to monitor a voxel scan hadron beam A.Boriano 3, F.Bourhaleb 2,3, R. Cirio 3, M. Donetti 2,3, F. Marchetto 3,
NON-SCALING FFAGs: questions needing answers Andy Wolski The Cockcroft Institute, and the University of Liverpool Department of Physics. BASROC-CONFORM.
Eric Prebys USPAS, Knoxville, TN, Jan , 2014.
Tools for Nuclear & Particle Physics Experimental Background.
The Magic Cube and the Pixel Ionization Chamber: detectors for monitor and dosimetry of radiotherapy beams S. Amerio 1, A. Boriano 2, F. Bourhaleb 2,3,
A NON LINEAR TRANSPORT LINE FOR THE OPTIMIZATION OF F18 PRODUCTION BY THE TOP LINAC INJECTOR C. Ronsivalle, L. Picardi, C. Cianfarani, G. Messina, G.L.
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
October 31, BDS Group1 ILC Beam Delivery System “Hybrid” Layout 2006e Release Preliminary M. Woodley.
Cooler Injector Synchrotron (CIS) at IUCF V.S. Morozov MEIC Collaboration Meeting March 30-31, 2015.
CERN Medical Applications Steve Myers Head of CERN Medical Applications Former Director of Accelerators and Technology CERN, Geneva.
J-PARC Accelerators Masahito Tomizawa KEK Acc. Lab. Outline, Status, Schedule of J-PARC accelerator MR Beam Power Upgrade.
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
FFAG-Workshop Dec Kumatori Japan Diagnostics for FFAG- accelerator Takahisa ITAHASHI Department of Physics, Osaka Univ. Toyonaka, Osaka, ,Japan.
EBIS ARR Jim Alessi May 4- 7, 2010 Technical Overview.
Part IV Applications. Prototype of Cancer therapy machine with proton 150 MeV FFAG as a prototype Commissioning to accelerate up to ~15 MeV is done. Tune.
Beam Instrumentation for the HIE-ISOLDE linac Francesca Zocca ISOLDE Workshop and Users Meeting December CERN Instituto de Estructura de la.
Lecture 9: Inelastic Scattering and Excited States 2/10/2003 Inelastic scattering refers to the process in which energy is transferred to the target,
Radioactive Ion Beams CW 0.5 MW (for protons) 1 GeV (for protons) p to U Chiara, Manuel, Adam, HuiMay 2011, CAS, Bilbao.
Accelerator Science and Technology Centre Extended ALICE Injector J.W. McKenzie, B.D. Muratori, Y.M. Saveliev STFC Daresbury Laboratory,
HIE-ISOLDE diagnostic boxes Esteban D. Cantero CERN BE-BI-PM HIE-ISOLDE meeting for BE/BI 28 March 2014 The research leading to these results has received.
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
ENLIGHT,12/2/20021 Health and Science, can CERN contribute? The Mission of CERN (1954): “The Organization shall provide for collaboration among European.
 A model of beam line built with G4Beamline (scripting tool for GEANT4)  Simulated performance downstream of the AC Dipole for core of beam using  x.
If information seems to be missing, make any reasonable assumptions. 1.A target has an areal density of 2.3 g/cm 2 and a thickness of 0.8 inch. What is.
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
The Introduction to CSNS Accelerators Oct. 5, 2010 Sheng Wang AP group, Accelerator Centre,IHEP, CAS.
PSB H- injection concept J.Borburgh, C.Bracco, C.Carli, B.Goddard, M.Hourican, B.Mikulec, W.Weterings,
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
F D F November 8, 2006Alessandro G. Ruggiero1 of GeV 10-MWatt Proton Driver Target 200-MeV DTL 1.0-GeV FFAG H – Stripping Foil Injection Energy,
Thomas Roser SPIN 2006 October 3, 2006 A Study of Polarized Proton Acceleration in J-PARC A.U.Luccio, M.Bai, T.Roser Brookhaven National Laboratory, Upton,
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
ADSR Inst.July 2009 From PAMELA to ADSR, T.Yokoi From PAMELA to ADSR Takeichiro Yokoi (JAI)
The Australian Hadron Therapy and Research Facility.
Koichi MurakamiGeant4 Physics Verification and Validation (17-19/Jul./2006) 1 Results from the recent carbon test beam at HIMAC Koichi Murakami Statoru.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Linac4 BCC 14/10/2010 Linac4 Measurement and Dump Lines BCC on the Linac4 Transfer Line Status.
ESS Front End diagnostic
High intensity electron beam and infrastructure Paolo Valente * INFN Roma * On behalf of the BTF and LINAC staff.
MLL Workshop on Future Science 2019 and beyond, 16.Dec.2015 The accelerator, as seen by.. 1 From LBNL Image Library Collection by Dave Judd and Ronn MacKenzie.
Polarized Injector Update
Beam Commissioning Adam Bartnik.
Alexander Aleksandrov Spallation Neutron Source Oak Ridge, USA
BEAM TRANSFER CHANNELS, INJECTION AND EXTRACTION SYSTEMS
Present and possible future schemes for hadron therapy linacs Alberto Degiovanni for the ADAM team HG2017 Workshop , Valencia.
Progress in the Application
Beam based measurements
Injector Cyclotron for a Medical FFAG
Accelerator layout > 1000 components (almost 300 magnets and power converters, 153 beam diagnostic devices, about 400m of vacuum pipes, a not neglectable.
Johannes Leidner, Fabrizio Murtas, Marco Silari
ELENA Overview and Layout Start of ELENA Commissioning Next Steps
of secondary light ion beams
of secondary light ion beams
PSB rf manipulations PSB cavities
Design of a PET-isotope-based hadron therapy facility
Proton Beam Diagnostics
Beam Current Monitoring with ICT and BPM Electronics
Advanced Research Electron Accelerator Laboratory
Considerations on Beam Diagnostics Physics
HALLA APEL REPORT Yves Roblin Hall A colllaboration Meeting
Presentation transcript:

Diagnostics for Medical Accelerators Anna Parravicini – Fondazione CNAO (Pavia – Italy) Diagnostics for Medical Accelerators

Medical Accelerators versus Experimental Accelerators /1 Medical machines are similar to LINAC, Cyclotron, Synchrotron used for low energy physics experiments, but… Patient Safety -> strict control to avoid over-dose to patient Treatment Quality -> dose distribution over cancer volume has to respect treatment planning requirements rigidly

Medical Accelerators versus Experimental Accelerators /2 Dose&Beam Delivery -> the medical machine requires a “brain” (called Nozzle) receiving treatment planning details from the Medical World and controlling Machine Side, depending on the delivered dose Diagnostics -> beam diagnostics for medical machine is basically the same used for experimental machine, but its goals and control can be significantly different

Medical Accelerators Overview /1 General Requirements: compact size, cost kept down, easy to use and to maintain, reliable, efficient @ Medical Centres: LINAC: compact size/ easy to use/ dedicated to conventional radiotherapy/ not suitable to accelerate hadrons up to hadrontherapy energies (prototypes of LINAC for hadrontherapy exist, but still not commercial)

Medical Accelerators Overview /2 Cyclotron: compact size/ easy to use/ continuous beam/ high intensity, small intensity ripples/ fixed energy (passive modulators must be changed to modify energy), not negligible energy spread/ maximum energy not enough for C-ion treatments Synchrotron: large size/ elaborate operation but flexible machine/ wide intensity range suitable for treatments (1Gy/min in 1 litre), despite risk of significant ripples/ wide energy range with small energy spread/ suitable for C-ion treatments

Synchrotron for Hadrontherapy /1 Hadrons release energy in the matter making Bragg’s peak, differently from the other particles Hadrontherapy key-point is the ability of killing diseased cells selectively, minimizing damages in the all around region In this scenario, beam position accuracy at patient level becomes mandatory not to save ‘bad’ cells -> Dose Uniformity [±2.5%] Bragg’s peak

Synchrotron for Hadrontherapy /2 Wide Energy Range (@ CNAO: source 8keV/u, after LINAC 7MeV/u, extraction 60-250MeV for protons, 120-400MeV/u for C6+ ions, energy resolution 1mm step equivalent) Wide Intensity Range (@ CNAO, one nominal spill contains 1E+10 protons or 4E+08 C6+ ions reducible of a factor 100, without emittance increasing) Cycle-based Machine: beam parameters change quickly (1-2 sec), depending on treatment requirements ->Different detector principles must be used

CNAO Layout 2 DC sources (protons and C6+ ions) synchrotron circumference 76.84m 3 horiz + 1 vert treatment lines 1 experimental line (for future) protons extracted at 60-250MeV C-ions extracted at 120-400MeV/u bar-of-charge for narrow beam in the horizontal plane active scanning first patient in few months

Monitors Requirements /1 (peculiar for Medical Machine) Fast Setting Up and Debugging [patients should not wait, for comfort & cost] -> don’t forget Beam Instrumentation at design time Monitors should not perturb beam -> non (or low) interceptive monitors only can be used during treatments [if we add/ remove targets on beam path, we change Bragg’s peak depth] Dose Delivery System -> system dedicated to measure the dose delivered to the patient

Monitors Requirements /2 (peculiar for Medical Machine) In particular, to guarantee treatment quality (@ CNAO): *** A long list here: details in the next pages *** Minimize Intensity Ripples: [magnets] debuncher, betatron – [operation] slow extraction – [diagnostic] Chopper Faraday Cup, Current Transformer, Beam Qualification Monitors (intensity), Servo-Spill Qualify Beam Size and Intensity: Beam Qualification Monitors intensity&position (before sending beam to patient), NOZZLE (control of scanning magnets)

Diagnostics Control /1 CNAO synchrotron works with a cycle about 2sec long It means that every 2sec a message is sent by the Timing System to all the subsystems (magnets, diagnostics, …) providing beam parameters (particles type, energy, intensity,...) needed for the next machine cycle

Diagnostics Control /2 Next cycle can start only if all the subsystems have sent back their right acknowledge Monitors setting (amplifier gain, slits position, expected parameters to qualify the beam…) changes automatically depending on the new beam parameters: in few ms machine configuration can change drastically (using the Timing message) The list of cycles to be executed is fixed by the treatment planning *of course*

Monitors in details Let’s go into details for some monitors used to improve beam quality, in position, dimension and intensity uniformity We refer to CNAO experience. Some monitors are available on the market, others are home-made and are aiming to satisfy peculiar needs of CNAO machine

Chopper Faraday Cup /1 Source beam is DC. Before entering LINAC, beam has to be bunched Chopper is a magnet deflecting particles towards vacuum chamber, to make bunched a continuous beam (@ CNAO injection line: beam against vacuum chamber for more than 95% time)

Chopper Faraday Cup /2 The Chopper Faraday Cup (CFC) aims to detect source current stability and ripples with 10kHz bandwidth. 1% resolution for the minimum beam current (C-ions, 0.15mA) requires 1.5uA absolute resolution CFC High Voltage switched ON/ OFF when Chopper OFF/ ON, not to perturb beam entering LINAC -> Beam uniformity is a key-point for medical machine, in particular for hadrontherapy

Degrader The machine is prepared for ‘nominal’ intensities, that can be reduced according to treatment planning requirements At CNAO we use a Degrader made of 3 pepper-pot metal plates, reducing intensities down to 10% of nominal value, without affecting beam emittance

Current Transformers Charge flow measurement: beam current changes during acceleration / beam charge *hopefully* remains constant Non-interceptive intensity measurement, for continuous (DC) and pulsed (AC) beams

AC-Beam Transformer For bunched beam (up to few ms long batches) Beam acts as a primary winding Beam current is read from the secondar winding tDroop [sec]= Winding Inductance [H] / Read-Out Resistance [Ω] After 1 tDroop, signal is exponentially reduced of 1/e

DC-Beam Transformer /1 For continuous beams (either DC-component of bunched beams) Use of two ‘identical’ cores Beam current measured through the magnetic field induced by the beam in the core Blind to fast current variations

DC-Beam Transformer /2

Beam Qualification /1 Beam size, position (QPM) and intensity (QIM) quality checked before sending beam to patient or during treatment suspensions: Avoid treatment interruption Improve treatment quality QPM+QIM placed in front of extraction line dump. During first 100ms of each spill, beam is dumped and qualified. If qualification result is positive, beam is sent to treatment room 34 fibers X Z Y BEAM 90 fibers Y (2-by-2 binned) Scintillating plate X

Beam Qualification /2 IN/OUT motion Qualification measurements cannot take more than 100ms: number of treatments per day must be maximized Automatic beam qualification: Cycle-Code dependent Algorithm to be commissioned IN/OUT motion

Servo-Spill Loop Dose Delivery system monitors ‘online’ (1MHz – if statistics significant) the number of particles sent to patient BUT… if intensity ripples are “very high” it is not enough to protect the patient from over-dose Machine detectors shall limit current intensity ripples to avoid voxel over-dose [from specifications, voxel dose peak < 4% voxel dose] We foresee open/ closed loop (10kHz bandwidth) between a large bandwidth intensity monitor in the extraction line (or the Nozzle) and the air-core quadrupole in the synchrotron, for fast correction to intensity ripples Intensity measurement perturbance on beam for patient must be minimized

Watch-Dog /1 At extraction lines end, the Nozzle controls scanning magnets power supplies so to direct the beam to the ‘right’ target Watch-Dog monitor aims to measure barycenter position at scanning magnets entrance, during treatment, so to check barycenter offset and its drift, during treatments (at 100Hz-300Hz) Extraction line correctors setting is changed consequently, in such a way to move beam barycenter to the center, if it is not To suppress beam position offset and drift is mandatory to avoid ‘dose holes’ at patients (-> Dose Uniformity)

Watch-Dog /2

Nozzle Nozzle is the usual name for Beam Delivery (beam steering to reach the right target position) and Dose Delivery (measuring the flow of particles going to the patient) systems It acts as interface between accelerator and medical worlds In case of active scanning (like CNAO) it controls scanning magnets

CNAO Nozzle /1 CNAO Nozzle is made of BOX1 and BOX2, each one made of 2 ionization chambers (->direct measurement of the charge delivered to patient) Nozzle is globally < 1mm water-equivalent thick Each BOX measures intensity (@1MHz / 1 cnt=200fC ~ 8000 protons at 60MeV) and position (@ 10kHz / 50um accuracy)

CNAO Nozzle /2 To conclude… …an example of scanning magnets control by the Nozzle Single Spot All Spots Strip Chambers (X white – Y red) Pixel Chamber

- Thanks for your attention -