Compact enclosure Fiber coupled sensor head Integrated data processor Server software for accessing data Can produce processed or raw data Single umbilical.

Slides:



Advertisements
Similar presentations
RavensNest 60 Channel Intelligent Video Solution The RavensNest is an enhanced video command and control platform that transforms any centralized analog.
Advertisements

FloormapVS2i.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
SieTec Security Ltd RD-RLY01DIN DIN Rail Mount Programmable Relay with RING DETECT USB Programmable Relay Unit Specification December 2011 Your Systems.
CIMExcel Software Inc. Slide 1 Advanced Drystock Control (ADC) to reduce the ‘residual’ basis weight, moisture, and caliper profiles CIMExcel Software.
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Copyright, Valiant Communications Limited E1 Protection Switching Equipment Confidential Slide 1 V aliant C ommunications L imited Telecom Transmission.
Environmental Monitoring System at GBC and Its Components Presenter: Sanjaya Gurung.
STARLight PDR 3 Oct ‘01I.1 Miller STARLight Control Module Design Ryan Miller STARLight Electrical Engineer (734)
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Louis J. Rubbo, Neil J. Cornish, and Olivier Poujade Support for this project was provided by the NASA EPSCoR program.
Fiber-Optic Communications
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Dataloggers. Records voltage, current, or circuit closing Environmental variables must be converted to electronic signal.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
Automated Feeding Solutions for Dog Owners Preliminary Design Review October 19, 2007 Project Automated Dog Feeder Project Advisor Dr. Hongwei Wu The Canine.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
GigE Knowledge. BODE, Company Profile Page: 2 Table of contents  GigE Benefits  Network Card and Jumbo Frames  Camera - IP address obtainment  Multi.
Media Chapter 2. Two types of Cables Baseband Broadband.
Vibration & Temperature Sensor. Contents ■ Why monitor vibration? ■ Monitor a wide range of machines ■ Vibration measurements ■ Set alarm levels ■ Mounting.
A Mobile Wireless Electrocardiogram System for Health Care Facilities John Farner Jason Fritts Julian Jaeger Joe Richard Georgia Institute of Technology.
Wind, wave and tidal energy DNV serving the energy industry.
Looking for a more powerful circuit monitor?
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
Pioneers in Non-contact Measurement. MTI Instruments, Inc.  Founded in now a public company listed on NASDAQ  Designs, manufactures and markets.
PRESENTS. A Video Dental, Inc. Product Line Established in 1999 CRA NewsletterSeptember
Empowering Business in Real Time. © Copyright 2009, OSIsoft Inc. All rights Reserved. Appleton Smart Web Trimming Project Regional Seminar Series Cincinnati.
TDS8000 and TDR Considerations to Help Solve Signal Integrity Issues.
Disc Thickness Measurement System. NI Based Measurement System NI Channel, 100 kS/s, 16-bit, ±10 V Simultaneous Sampling Analog Input Module.
System Overview Model 1088B Sentinel CM Splice Detector Technology Bruce T. Dobbie.
System Overview Model 1032B Classic CM Splice Detector Technology Bruce T. Dobbie.
Data Signals and Collection. Data Types 2 types of output 2 types of output – Analogue Usually raw signal Usually raw signal Raw Voltage Raw Voltage –
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
RADITEK inc RADITEK-RFTS-M1-L21WORLD HQ: 1702L Meridian Ave. Suite 127, San Jose, Ca 95125, U.S.A. Tel: (408) FAX: (408) WEB:
Hardware Introduction – Standard vs Q.i
Group: CCM Project 2.5. EMERSON Emerson is a diversified global manufacturing company.  Provides innovative solutions to customers in the following areas:
System Overview Model 1088 Sentinel Splice Detector Technologies Bruce T. Dobbie.
System Overview Model 1032 Classic Splice Detector Technology Bruce T. Dobbie.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
System Overview Model 1032C MCM Splice Detector Technology Bruce T. Dobbie.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Analog Conditioning1 Quantification of E.M.G.. Analog Conditioning2 RAW EMG Continuously changing positive and negative deflections. How do you reduce.
CMOS Analog Design Using All-Region MOSFET Modeling
아이알브이테크 1 IRV-TECH 아이알브이테크 May 12, 2015 IRV-65B Light Source.
FHF Copyright © 2011 by The McGraw-Hill Companies, Inc. All rights reserved. McGraw-Hill/Irwin.
IN-Circuit Tester ESI-2002 / ESI-2002 ST Windows Based High Speed IN-Circuit Tester.
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
Sampling. Introduction  Sampling refers to the process of converting a continuous, analog signal to discrete digital numbers.
Linescanner MP150 Infrared Temperature Measurement for Quality Control and Process Automation Raytek Confidential 10/2010, Rev. B.
Cosmic Microwave Technology, Inc.
ControlLogix 5580 Controller
C1300 advanced circular chart recorder
Digium Platform product for Switchvox
Radio Frequency Identification (RFID)
Presentation of Vision System
Disc Thickness Measurement System
V7 UPS Sales Training.
TORQUE MEASURMENT.
Quantification of E.M.G..
Communication Interface for Vision Applications
Commodity Flash ADC-FPGA Based Electronics for an
Technician Operation Presentation
CrystaLatchTM High Power 1x1,1x2 Solid-State Fiberoptic Switch (5W CW)
CrystaLatchTM 1x8 Fiberoptic Switch
Performance Specifications
CrystaLatchTM 1x1, 1x2, Solid-State Fiberoptic Switch
CrystaLatchTM 1x2 PM Bidirectional Fiberoptic Switch
CrystaLatchTM 1x2 Multicasting Solid-State Fiberoptic Switch
Presentation transcript:

Compact enclosure Fiber coupled sensor head Integrated data processor Server software for accessing data Can produce processed or raw data Single umbilical for transceiver heads Multiple sensor heads available Easy switching between products Digital inputs available for data tagging T-Gauge ® Sensor Configuration T-GAUGE ® The T-Gauge ® Sensor Configuration changes the paradigm of online process control. By coupling a T-Gauge Pulsed Terahertz Controller with an umbilical and a Sensor head, a high fidelity terahertz pulse can be produced. The rich data derived from the pulsed terahertz signal allows multiple measurements from a single sensor. The multitude of connection options allows seamless integration with any QCS system. Measurements of basis weight, density, caliper thickness, multi-layer thickness and moisture can be made with a single compact sensor technology. The T-Gauge ® Pulsed Terahertz Controller is the heart of the T-Gauge ® Sensor Configuration. The Controller comprises the short pulse laser, time delay rail, and data collection electronics. With a waveform acquisition time of 10ms, the TCU5210 is the fastest, full featured time domain terahertz controller available. FEATURES Industrial process control Nondestructive materials inspection Package inspection Semiconductor wafer inspection Converting applications Multi-layer thickness measurement Building products Paper and paper coaters Foams and foam products APPLICATIONS By using pulse Time-of-Flight (ToF) to make its measurements, the T- Gauge ® Sensor Configuration has greater insensitivity to environmental and material variations that can lead to calibration inaccuracies. The terahertz energy emitted by the T-Gauge ® Sensor is so low, that there are no safety concerns with operation. No radioactive materials and no ionizing radiation is used.

2925 Boardwalk Ann Arbor, MI 48104, USA phone: fax: T-GAUGE ® QUALITY VISION As a leader in terahertz instrumentation, Picometrix is committed to providing the highest quality ultrafast products on the market. This quality vision commits us to continually improving our product designs and manufacturing processes in order to ensure the highest level of customer satisfaction. The company maintains a stringent quality control program to ensure that all products meet or surpass customer requirements. © 2012 Advanced Photonix, Inc.. All rights reserved. Specifications and output data subject to change without notice. DS-TR5000-preliminary REQUIRED EQUIPMENT Fiber/electrical umbilical T-Gauge Sensor Head or Tx/Rx pair OPTIONAL EQUIPMENT Umbilical Junction Box Sample calibration fixture Wall mount bracket Rack mount brackets (shown) CONTROLLER FEATURES FeatureDescription Aux Connectors4 USB ports, 2 Ethernet ports Voltage OptionPower supplies are self-sensing Waveform Acquisition100 Hz or 1000 Hz waveform acquisition rate available Umbilical length meters configurable Digital Inputs16 digital inputs Encoder Inputs6 high speed encoder inputs T-GAUGE ® Control Unit (TCU5210) ParameterSpecificationUnitsComments Pulse Bandwidth0.02 to 3.5 THz Transmission, 1 min average Pulse Amplitude Stability.22%Single trace, no averaging Polarization Extinction Ratio>20:1 Signal-to-Noise Ratio>80dBFrequency Domain, 1 min average Rapid Scan Range320ps 80 ps with delay option Rapid Scan Rate100Hz1000 Hz with delay option Weight23kg(55 lbs) Spectral resolution3.1 GHz Spectral stability.31GHzstandard deviation.1 sec avg Spectral amplitude stability.006dBstandard deviation 10 sec avg Size (W x D x H)17.5 x 21.5 x 7.5inches Weight16kg35 lbs