VisiVolt™ Passive Voltage Indicator OEM Presentation

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

Inspection & Preventive maintenance of breakers
International Symposium on Standards for UHV Transmission System Impacts on UHV Substation Equipment On behalf of CIGRE WG A January 2009,
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Maintenance At Your WWTP August 2010
FIPTMV Medium Voltage Technology
Mr. Harethe El Ouadhane IEC member for IEC MT14. |Infrastructure Business | Germany | Test Engineer & Expert (Internal Arc, Making, Breaking.
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
SF6 load-break switch-disconnector
Electrical Systems Electrical Engineering in Railways –Rolling Stock –Communications & Control –Signalling –LV Installations in Stations and Buildings.
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
Frankfurt (Germany), 6-9 June 2011 SINGH– US – Session 1 – 0952 Dry-type Transformer for Pole Mounted Application.
Standardization Aspects in UHV Networks New Delhi, January 2009 Denis Dufournet Chairman IEC TC17 Member CIGRE WG A3-22.
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
Transmission Lines …….. Conductor Material
Unit-3 SUBSTATIONS.
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
VIKING Workshop – Hamburg, DE, March 2007 Best Practices in Monitoring Deployment, Hamburg, Germany Innovation in Monitoring VIKING Workshop “Best.
Pole Mounted Switch Disconnector NPS
MNS Sprint - A Market Driven Solution
All rights reserved Surge Arrester.
What makes substation work?
Frankfurt (Germany), 6-9 June 2011 Hans-Erik Olovsson – Sweden – Session 1 Network Components – Paper 0453 Innovative Compact 145/12 kV Indoor Air Insulated.
All rights reserved Gas-insulated Switchgear (GIS)
All rights reserved MV SWITCHGEAR.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
SIGMA INSTITUTE OF ENGINEERING
Medium Voltage Outdoor Apparatus Portfolio
Utility Engineers, PC.  Generation  Transmission  Distribution.
Physical Science Spring Review Electricity and Magnetism.
POWER HOUSE.
Submitted to: Submitted by:
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
Distribution Systems-General
Department of Electrical Engineering
A Training Presentation On 220 KV GSS CHOMU,JAIPUR
132KV GSS PIPAR CITY JODHPUR
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Disconnector Switches and Earth Switches
ETP 1138C Week #2 Advanced print reading basics (Types of Engineering documentation) This week we will cover the following topics in class: We will introduce.
What makes substation work?
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
EE 2353 HIGH VOLTAGE ENGINEERING
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
AUTOMATIC CIRCUIT RECLOSER
6 Week industrial Training Presentation
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Hipot Testing 101.
Sub Station.
Sensor presentation.
SUB-STATIONS.
Chapter # 25 Sub-Stations risemark.pbworks.com.
WELCOME TO ALL.
Oil-tight MV fuse CEF-OT with TPC bushings
EHV Transmission Equipments
Bushings.
All rights reserved Gas-insulated Switchgear (GIS)
Its strengths, your benefits
Electrical components and systems
CORDLESS PHASING TESTER
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

VisiVolt™ Passive Voltage Indicator OEM Presentation GPMM Tomasz Komalski 2011 VisiVolt™ Passive Voltage Indicator OEM Presentation © ABB Group April 20, 2017 | Slide 1

VisiVolt™Passive Voltage Indicator Increased safety Electric accidents belong to the most frequent and serious ones Medium voltage distribution systems are the most prone to accidents Typical reasons: false belief in voltage absence originating from lack of communication, mistake etc. not following the safety procedures Picture courtesy of www.line-man.com Prevention of electric accidents is one of very important aspects of operation of power distribution systems. Even though, electric accidents do happen, and, among other type of accidents, are those of high rate of serious consequences. The medium voltage power distribution systems feature very dangerous voltage levels of several thousand volts and in the same time relatively easy accessibility of conductors under voltage. This is why, in such systems, the rate of serious consequences of accidents is believed to be the highest. On the other hand, typical reasons of accidents are not complex. It is most of the times just a momentary distraction of a worker, misunderstanding in communication or a mistake which leads to false belief that the voltage is not present on the system when it actually is. A possible way of preventing such situations from happening is to provide a broadly applicable system of making the presence of voltage visible on the serviceable systems. © ABB Group April 20, 2017 | Slide 2

VisiVolt™Passive Voltage Indicator VisiVolt™ - Introduction Previously used neon indicators VisiVolt™ installation © ABB Group April 20, 2017 | Slide 3

VisiVolt™Passive Voltage Indicator VisiVolt™ - Introduction Product name: PL: Pasywny Wskaźnik Napięcia EN: Passive Voltage Indicator RU: Пассивный Индикатор Напряжения FR: Indicateur Passif de Tension DE: Passiver Spannungsanzeiger ES: Indicador Pasivo de Tensión Previously known as (prototype and pilot products): PVI PassVI VisiVolt™ is an indicator of voltage presence For permanent installation Current-bar mounted type (belongs to the primary circuits) To be used on not screened (not ground-shielded) conductors Passive Outdoor and indoor application For systems of nominal voltages from 3kV/6kV to 36kV © ABB Group April 20, 2017 | Slide 4

VisiVolt™Passive Voltage Indicator IEC standards Hot stick mounted indicators for line testing IEC 61243-1 Live working - Voltage detectors – Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c. IEC 61243-2 Live working - Voltage detectors – Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c. Low voltage indicators IEC 61243-3 Live working - Voltage detectors – Part 3: Two-pole low-voltage type Indicators installed permanently (e.g. in switchgear) IEC 61243-5 Live working - Voltage detectors - Part 5: Voltage detecting systems (VDS) IEC 61958 High-voltage prefabricated switchgear and controlgear assemblies – Voltage presence indicating systems (VPIS) Threshold voltages: indication at >45% of nominal voltage; no indication at <10% of nominal voltage © ABB Group April 20, 2017 | Slide 5

VisiVolt™Passive Voltage Indicator Type tests Test of voltage thresholds Dielectric tests Short-time withstand current and peak withstand current tests Moisture ingress test Sun radiation test Low- and high-temperature functionality tests Configuration of measurement © ABB Group April 20, 2017 | Slide 6

Conductor under AC voltage VisiVolt™Passive Voltage Indicator Global intellectual property protection AC electric field Conductor under AC voltage © ABB Group April 20, 2017 | Slide 7

VisiVolt™Passive Voltage Indicator Specification application and threshold voltages © ABB Group April 20, 2017 | Slide 8

VisiVolt™Passive Voltage Indicator Threshold Voltages - Example VisiVolt™ type: VV-B System Un = 15 kV 45% Un = 6.75 kV Lack of indication Area of transition “Presence of voltage” indication Point of normal operation 1.5kV 45% Un Un/√3 phase-earth or phase-phase voltage [kV] © ABB Group April 20, 2017 | Slide 9

VisiVolt™Passive Voltage Indicator Withstand voltages © ABB Group April 20, 2017 | Slide 10

VisiVolt™Passive Voltage Indicator Installation – current conductors and bars On a circular-section conductor of small diameter On vertical current bar using spacers © ABB Group April 20, 2017 | Slide 11

VisiVolt™Passive Voltage Indicator KIPTS (Koeberg Insulator Pollution Test Station) South Africa 04 2007 © ABB Group April 20, 2017 | Slide 12

VisiVolt™Passive Voltage Indicator ABB SECTOS outdoor switch-disconnectors, Poland December 2006, May 2007 © ABB Group April 20, 2017 | Slide 13

VisiVolt™Passive Voltage Indicator Aquarina – Testing station in Florida 2007-07-20 © ABB Group April 20, 2017 | Slide 14

VisiVolt™Passive Voltage Indicator 110/15kV Substation, Niepołomice, Poland March 2007 15kV busbar bridge 15/0.4kV auxiliary transformer (voltage not present yet) © ABB Group April 20, 2017 | Slide 15

VisiVolt™Passive Voltage Indicator Advantages of VisiVolt™ Differentiating features of the product: Both indoor and outdoor application possibility Reflective display of good visibility under all lighting conditions (from dim indoor to bright outdoor) Large display size – visibility from long distance (e.g. on a pole mounted equipment) No electronic circuit – display element is the sensitive element All polymer components – no steel parts – no risk of corrosion © ABB Group April 20, 2017 | Slide 16

VisiVolt™Passive Voltage Indicator Main functions & marketing points Warning function – increased safety Higher level of safety of operating and servicing the system. Check of voltage status Without using any additional equipment, the personnel can check the status of voltage presence. Confirming of equipment operation At equipment with no visible gap (e.g. Sectos switch disconnector) VisiVolt confirms the correct operation of the switch and disconnector. © ABB Group April 20, 2017 | Slide 17

VisiVolt™Passive Voltage Indicator To prevent accidents Engineered for Safety Follow the leader. We know how important safety is for you. That’s why ABB Medium Voltage Products puts your safety- and the safety of your personnel – first. VisiVolt can prevent accidents by providing visualization of voltage presence at service points In an unexpected situation can warn the personnel about the presence of voltage before it is too late. Discourage the personnel from breaking the safety rules (e.g. working unprotected to close to a live system) VisiVolt was part of the US ABB campaign: „Engineered for Safety” © ABB Group April 20, 2017 | Slide 18

© ABB Group April 20, 2017 | Slide 19