1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore-570 008 Mob: 9342188467.

Slides:



Advertisements
Similar presentations
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Advertisements

2.2 STRUCTURAL ELEMENT BEAM
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Chp12- Footings.
Summary Sheet Session Number : Date : Subject Expert : Dr. M.C. Nataraja Professor Department of Civil Engineering, S.J. College of Engineering,
Lecture 9 - Flexure June 20, 2003 CVEN 444.
Bridge Engineering (6) Superstructure – Concrete Bridges
Umm Al-Qura University Department of Civil & Structural Engineering
 Temperature Stresses  – Due to the temperature differential between the top  and bottom of the slab, curling stresses (similar to  bending stresses)
Summary Sheet Session Number : 3 Date : Subject Expert :
STATICALLY DETERMINATE STRESS SYSTEMS
ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES
Summary Sheet Session Number : Date : Subject Expert : Dr. M.C. Nataraja Professor Department of Civil Engineering, Sri Jayachamarajendra.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Lecture Goals Slab design reinforcement.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Chp.12 Cont. – Examples to design Footings
Bridge Engineering (7) Superstructure – Reinforced Concrete Bridges
CTC 422 Design of Steel Structures
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
UNIT-I STANDARD SPECIFICATION FOR ROAD BRIDGE
CM 197 Mechanics of Materials Chap 14: Stresses in Beams
Slab Design.
Reinforced Concrete Design II
1 Design and Detailing of steel in Combined Footings Dr. M.C. NATARAJA.
ERT352 FARM STRUCTURES RETAINING WALL DESIGN
Lecture 11 Advance Design of RC Structure Retaining walls
Footings.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Code Comparison between
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
1. By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. CE-401 Reinforced Concrete Design-II.
1 Summary Sheet Session Number : Date : Subject Expert : Dr. M.C. Nataraja Professor Department of Civil Engineering, Sri Jayachamarajendra.
Beam Design.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
WORKSHEET 2 FAILURE, STRESS AND STRAIN
Chapter 6 Plate girder.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of one-way solid slabs Lecture (1)
University of Palestine
Plain & Reinforced Concrete-1 CE-313
BEAMS AND COLUMNS.
BEAMS AND COLUMNS PRESENTED BY K.ROSHIN RUKSHANA.
TOPICS COVERED Building Configuration Response of Concrete Buildings
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Bridge Design to AS 5100 Sydney May 25th 2005 Using High Strength Concrete with AS 5100 opportunities and restrictions.
Session 15 – 16 SHEET PILE STRUCTURES
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Lecture 1 January 17,  Sudhir K. Jain, IIT Kanpur E-Course on Seismic Design of Tanks/ January 2006 Lecture 1 / Slide 2 In this lecture Types of.
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of Flat Slab Floors Lecture (3)
6- Calculation of shear stress at composite interface: A)Under service load: Strain and stress distributions across composite beam cross- section, under.
DESIGN OF SINGLY REINFORCED BEAM
Prof. Shrikant M. Harle Asst prof. Dept of Civil Engg PRMCEAM
Chapter 12 Lecture 22: Static Equilibrium and Elasticity: II.
Dr Badorul Hisham Abu Bakar
CIVL471 DESIGN OF RC STRUCTURES
An-Najah National University Faculty of Engineering
Stress – Strain Relationships Credit: Modified from:
UNIT-IV SHEAR,TORSION AND BOND.
WATER TANKS.
(i) proper arrangement of reinforcing bars and
FOR 5TH SEMESTER DIPLOMA IN CIVIL ENGINEERING
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
Lecture 1 January 17, 2006.
Design of Reinforced Concrete
By :Dr. Aeid A. Abdulrazeg
Plain & Reinforced Concrete-1 CE3601
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Reinforced concrete column
Presentation transcript:

1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:

2 WATER TANKS

3 Learning out Come REVIEW TYPES OF TANKS DESIGN OF RECTANGULAR WATER TANK RESTING ON GROUND WITH RIGID BASE

4 INTRODUCTION Storage tanks are built for storing water, liquid petroleum, petroleum products and similar liquids Designed as crack free structures to eliminate any leakage Permeability of concrete is directly proportional to water cement ratio. Cement content ranging from 330 Kg/m 3 to 530 Kg/m 3 is recommended in order to keep shrinkage low.

5 INTRODUCTION Use of high strength deformed bars of grade Fe415 are recommended for the construction of liquid retaining structures Correct placing of reinforcement, use of small sized and use of deformed bars lead to a diffused distribution of cracks A crack width of 0.1mm has been accepted as permissible value in liquid retaining structures

6 INTRODUCTION Code of Practice for the storage of Liquids- IS3370 (Part I to IV) Fractured strength of concrete is computed using the formula given in clause of IS ie., fcr=0.7  f ck MPa. Allowable stresses in reinforcing steel as per IS 3370 are  st = 115 MPa for Mild steel (Fe250) and  st = 150 MPa for HYSD bars(Fe415)

7 INTRODUCTION In order to minimize cracking due to shrinkage and temperature, minimum reinforcement is recommended as: For thickness  100 mm = 0.3 % For thickness  450 mm = 0.2% For thickness between 100 mm to 450 mm = varies linearly from 0.3% to 0.2% For concrete thickness  225 mm, two layers of reinforcement be placed, one near water face and other away from water face.

8 INTRODUCTION Cover to reinforcement is greater of i) 25 mm, ii) Diameter of main bar For tension on outer face:  st=140 MPa for Mild steel and  st=230 MPa for HYSD bars For concrete thickness  225 mm, two layers of reinforcement be placed, one near water face and other away from water face.

9 TYPES OF WATER TANK

10 WATER TANK BASED ON PLACEMENT OF TANK BASED ON SHAPE OF TANK 1. RESTING ON GROUND 2. UNDER GROUND 3. ELEVATED 1. CIRCULAR 2. RECTANGULAR 3. SPHERICAL 4. INTZ 5. CONICAL BOTTOM

11 RESTING ON GROUND

12 UNDERGROUND

13 ELEVATED

14 CIRCULAR

15 RECTANGULAR

16 SPHERICAL

17 INTZ

18 CONICAL BOTTOM

19 RECTANGULAR WATER TANKS RESTING ON GROUND

20 Introduction Rectangular tanks are used when the storage capacity is small Rectangular tanks should be preferably square in plan from point of view of economy. It is also desirable that longer side should not be greater than twice the smaller side.

21 Introduction Moments are caused in two directions of the wall ie., both in horizontal as well as in vertical direction Exact analysis is difficult and are designed by approximate methods. When the length of the wall is more in comparison to its height, the moments will be mainly in the vertical direction, ie., the panel bends as vertical cantilever

22 Introduction When the height is large in comparison to its length, the moments will be in the horizontal direction and panel bends as a thin slab supported on edges. For intermediate condition bending takes place both in horizontal and vertical direction. In addition to the moments, the walls are also subjected to direct pull exerted by water pressure on some portion of walls.

23 Introduction The walls are designed both for direct tension and bending moment.

24 Introduction

25 Introduction IS3370 (Part-IV) gives tables for moments and shear forces in walls for certain edge condition. Table 3 of IS3370 provides coefficient for max Bending moments in horizontal and vertical direction.

26 Introduction Horizontal steel is provided for net bending moment and direct tensile force Ast=Ast1+Ast2; M’=Maximum horizontal bending moment – T x; x= d-D/2 Ast2=T/  st x D/2 d

27 DESIGN PROBLEM

28 Introduction Design a rectangular water tank 5m x 4m with depth of storage 3m, resting on ground and whose walls are rigidly joined at vertical and horizontal edges. Assume M20 concrete and Fe415 grade steel. Sketch the details of reinforcement in the tank

29 Step1: Analysis for moment and tensile force E B A F D C Free a=H=3m b=4m L=5m Fixed

30 Step1: Analysis for moment and tensile force i) Long wall:

31 Step2: Design Constants

32 Step3: Design for Vertical moment

33 Step3: Design for Vertical moment

34 Step4: Design for Horizontal moment Horizontal moments at the corner in long and short wall produce unbalanced moment at the joint. This unbalanced moment has to be distributed to get balanced moment using moment distribution method.

35 Step4: Design for Horizontal moment

36 Step4: Design for Horizontal moment

37 Step4: Design for Horizontal moment

38 Step4: Design for Horizontal moment

39 Step5: Base Slab The slab is resting on firm ground. Hence nominal thickness and reinforcement is provided. The thickness of slab is assumed to be 200 mm and 0.24% reinforcement is provided in the form of 200 c/c. at top and bottom A haunch of 150 x 150 x 150 mm size is provided at all corners

40 Detailing

41 Detailing

42 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob: