Thermostatic Shower Restriction Valve UES Measure Ryan Firestone Regional Technical Forum 7/21/2015.

Slides:



Advertisements
Similar presentations
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
Advertisements

Residential LED UES Measure Update Regional Technical Forum August 20, 2013.
D EEMED M EASURE U PDATES June 1, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Residential and Commercial Storage Electric Resistance Water Heaters (Efficient Tanks) Mohit Singh-Chhabra Regional Technical Forum February 18, 2015.
Commercial Tank Water Heaters Out-of-Compliance (OOC) UES Measure Recommendation Regional Technical Forum November 19, 2013.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
Commercial Showerhead UES Measure Update Regional Technical Forum Staff Update June 18, 2013.
Research Strategy Review: Heat Pump Water Heaters Thermostatic Restriction Valves Jennifer Anziano RTF R&E Subcommittee July 8, 2015.
Heat Pump Water Heater (HPWH) Subcommittee Christian Douglass Regional Technical Forum June 18, 2015.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Advanced Power Strips (APS) Planning UES Measure Proposal Regional Technical Forum August 20, 2013.
Implementer’s Group April 2015 Meeting Debrief and Upcoming Meeting Prep April 24, 2015.
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
HPWH UES Measure Initial Review 16 April Agenda Provisional Measure Review Method Overview Prelim Findings Measure Development Approach Simulation.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
C OMMERCIAL S HOWERHEAD M ETERING S TUDY April 5, 2011 Regional Technical Forum Presented by: Michael Baker SBW Consulting, Inc.
Scientific Irrigation Scheduling Provisional Standard Protocol Ryan Firestone Regional Technical Forum February 18, 2015.
Capacity Impacts of Energy Efficiency What We Know and What We Don’t Know March 11, 2014.
New Measure Submission Process Regional Technical Forum January 22nd, 2014.
Thermostatic Shower Restriction Valve –Measure Screening Results New Measure Proposal February 19th, 2014.
Non-Residential Network Computer Power Management UES Measure Update Regional Technical Forum July 16, 2013.
Pre-Rinse Spray Valve Small Saver UES Measures Regional Technical Forum September 17, 2013.
Residential Behavior Programs RTF Subcommittee Ryan Firestone September 17, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
Commercial Showerhead UES Measure Update Regional Technical Forum Staff Update June 18, 2013.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
RTF Staff, Subcommittee and Work Updates November 1, 2011.
N ETWORK PC P OWER M ANAGEMENT June 28, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
Commercial Showerhead UES Measure Update Regional Technical Forum April 16, 2013.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Integration Issues for RTF Guidelines: Savings, Lifetimes and Cost/Benefit October 24, 2012 Regional Technical Forum Presented by: Michael Baker, SBW.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
Implementer’s Group June 2015 RTF Meeting Debrief and Upcoming Meeting Prep June 23, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Low-flow Showerheads for Residential and Select Commercial Applications Danielle Gidding.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Commercial Clothes Washers UES Ryan Firestone Regional Technical Forum April 14, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Commercial Clothes Washer UES Measure Update Regional Technical Forum April 16, 2013.
Residential Showerheads UES Update Ryan Firestone Regional Technical Forum October 20, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
D EEMED M EASURE U PDATES May 3, 2011 Regional Technical Forum Presented by: Bob Tingleff SBW Consulting, Inc.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
RTF Management Updates Jennifer Light Regional Technical Forum January 21, 2016.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
RTF Management Update Jennifer Anziano Regional Technical Forum July 21, 2015.
Non-Residential Network Computer Power Management Christian Douglass Regional Technical Forum January 21, 2016.
Non-Proven Residential Duct Sealing Measures: Research Strategy Josh Rushton and Adam Hadley Research and Evaluation Subcommittee October 7, 2015.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Direct Mail CFLs Ryan Firestone and Carrie Nelson August 30, 2011.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Residential Behavior-based Programs Measure Development Update Ryan Firestone Regional Technical Forum March 15, 2016.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Presentation transcript:

Thermostatic Shower Restriction Valve UES Measure Ryan Firestone Regional Technical Forum 7/21/2015

Overview Today, we are seeking to approve a Thermostatic Shower Restriction Valve UES measure. Review savings analysis methodology – Analysis of metered data – Application regional characteristic data – Measure interaction Propose as Planning measure – Large savings potential – Significant uncertainties in savings 2

Measure Overview Measure DevelopersRTF Staff/CAT CAT ReviewRyan Firestone, Mohit Singh-Chhabra Tech Sub-Com Review[none] R&E Sub-Com ReviewJuly 8, 2015 Notes New measure proposal submitted in 2013 Staff/CAT preliminary analysis present at Feb RTF meeting o RTF approved allocation of staff resources towards developing a Thermostatic Shower Restriction Valve Provisional UES measure 3

Showerers typically turn on water and wait for water temperature to rise before commencing shower – Structural waste: plug of cooled off water in hot water pipe – Behavioral waste: additional water used after temperature rise but before shower Device works by slowing shower flow to a trickle once the hot water reaches the valve, thus reducing the behavioral waste. Device is installed in-line between shower arm and shower-head. – Can be coupled with low-flow showerhead. Evolve Technologies’s ShowerStart TSV is the only product currently on the market. Technology Description

State of Knowledge LBNL metered study of baseline shower patterns – 11 homes (18 bathrooms) with usable events – Gas DHW homes in California metered in 2013 – Not a random sample: participants were recruited – Evolve Technologies analysis of data from December usable events – Start of behavioral waste: Clear temperature pass of 35 degC – End of behavioral waste: adjustment to lower temperature plateau ~50% of events not usable Average behavior waste per home: 38 seconds per usable event Usable Not usable

State of Knowledge LBNL metered study of baseline shower patterns – 11 homes (18 bathrooms) with usable events – Gas DHW homes in California metered in 2013 – Not a random sample: participants were recruited – Evolve Technologies analysis of data from December usable events – Start of behavioral waste: Clear temperature pass of 35 degC – End of behavioral waste: adjustment to lower temperature plateau ~50% of events not usable Average behavior waste per home: 38 seconds per usable event Behavior waste duration of 38 seconds/shower used in Measure Assessment. LBNL data may underestimate NW behavior waste due to location of study and participant selection process. 38 seconds/shower may overstate average behavior waste if some “not usable” events have less behavior waste savings potential.

State of Knowledge Pennsylvania Power and Light (Cadmus), 2014 – Metered pilot study ~20 homes x 1 month ~100 kWh/yr savings for showers with electric heated water – IEPEC paper detailing the evaluation to be published in August, 2015 Measure appears in several state TRMs and evaluations – Savings based on engineering analysis PSE MF pilot program – Program running smoothly, few complaints – Will likely not be evaluated until next biennium evaluation cycle.

Measure Identifiers 72, defined by – Market segment (2) Residential Health Care and Assisted Living – Equipment type (4) valve only valve and 2.0 gpm showerhead valve and 1.75 gpm showerhead valve and 1.5 gpm showerhead – Hot water type (3) electric resistance electric heat pump any (including gas) – Delivery mechanism (3) Direct Install Retail Mail by request Not using pre-conditions showerhead flow rate as a measure identifier – Using RBSA average for all measure instances – Keeps number of measure instances manageable Incremental savings from low flow showerhead are less than in Residential Showerhead UES measure. Primarily due to lower, RBSA-based estimate of people-per-showerhead (1.7), relative to Showerhead measure (2.5). Added this Commercial application because of program activity in other regions Separate residential segments (SF, MH, MF) may be warranted when more data is available.

Savings Methodology Electric savings is a product of – Hot water savings per shower event Showerhead flow rate (gpm) Behavior waste savings (minutes) % Hot Water (during warm-up) % of Shower (vs. tub) start – Shower events per year Showers_per_person (showers/person/year) People_per_shower (person/shower) – Hot water energy intensity ΔTemp_HotWater (T Water Heater Setpoint – T Inlet ) Water Heater Recovery Efficiency (COP) – 1 - Removal rate – 1 - Non-install rate Showerhead UES measure Heat Pump Water Heater UES measure

Savings Methodology [Go over Parameters sheet in workbook]

Measure Interaction Residential Showerhead UES measure – The effect of TSRV on the Showerhead measure is small enough to neglect Based on LBNL data, behavioral waste ~8% of [total water consumed] - [structural waste] That means an 8% difference between savings with and without TSRV – TSRV measure baseline should not be low-flow showerhead This product may appeal to consumers who don’t want a low-flow showerhead Therefore, TSRV measure uses average pre-conditions flow rate TSRV w/ LF Showerhead measure properly accounts for savings from this bundling of measures. Residential Heat Pump Water Heater UES measure – TSRV measure accounts for COP as a measure identifier {resistance, heat pump} – The effect of TSRV on the HPWH measure is small enough to neglect Behavioral waste is ~3% of total hot water use – Based on LBNL data and estimated 40% of DHW for showers

Measure Savings

Measure Cost

Measure Life Rated life of ShowerStart is 10,000 cycles Lifetime capped at 10 years to reflect other modes of failure and potential for removal before end of life

Cost effectiveness Water savings make measure highly cost effective 1.0

TSRV as a Planning Measure Staff/CAT recommend TSRV as a Planning measure – Significant uncertainties in parameter values Behavioral waste duration Effectiveness of TSRV in field Tub vs. shower start mix (pre- and post-TSRV) Participant mix of shower types, shower head types, DHW system types Removal/poor-performance rate, non-install rate – Large regional potential Residential ~20 aMW – (85% of electric DHW homes x 1.7 showerheads per home) Health care and assisted living ~0.1 aMW – (85% x showerhead count from Commercial Showerhead UES analysis x ~50% electric DHW) – Likely annual uptake: CA: 300,000 units in programs per year (4 th year in EE programs) NW estimate: 105,000 units/year x 30 to 100 kWh/unit = 0.36 to 1.2 aMW per year 16

Research Strategy Baseline and Participant metered study (30 sites x 4 segments) – Metered shower usage Pilot program (100s sites x 4 segments x 3 delivery mechanisms) – Removal and non-install rates – Site characteristics of participants 17 Parameter Baseline and Participant metered study Pilot program evaluation Baseline showerhead flow rate (gpm) x Behavior waste savings (minutes)x % Hot Water (during warm-up)x % of Shower (vs. tub) startx Showers per year, per showerheadx ΔTemp_HotWater (TWater Heater Setpoint – TInlet) (°F) x Water Heater Recovery Efficiency (COP) Removal and poor-performance ratex x Non-install rate x For Valve with Low-flow Showerhead Time in shower (total shower minus waste) (minutes) x % Hot Water during showerx

Research Strategy Research and Evaluation Subcommittee feedback on draft Research Strategy – Consider SF/MH/MF as separate segments – Consider DHW system parameters that affect time for water to reach temperature Proximity of shower to water heater Presence of recirculation loop 18

Proposed Motion “I _________ move that the RTF approve the Thermostatic Shower Restriction Valve UES measure and Research Strategy as presented: – Set the category to ‘Planning’ – Set the status to ‘Active’ – Set the sunset date to July 31, 2018” AND “I _________ move that the RTF direct Staff to update the parameter values in the Residential Showerhead UES measure to be consistent with the TSRV parameter values.” 19