CHEM-VENT ®. The CHEM-VENT ® First ever AAV manufactured specifically for Acid Waste systems Material is NSF 014 and ASTM D-4101 compliant NSF certified.

Slides:



Advertisements
Similar presentations
Typical Plumbing System
Advertisements

Architectural Services Department HKSAR Laboratory Design for Secondary Schools.
Sino Pipe Fitting Mould Co. is the professional and high classic pipe fitting mould manufacturers in the world. To consider the big moulds investment.
Degassing Valve for Corrosive & Ultra-pure Liquids Series DGV US Patent #7,481,238 B2.
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
HVACR316 - Piping Piping and Fitting.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
1926 Subpart J Establishes the requirements for welding and cutting in the construction industry Establishes requirements for equipment, fire protection,
STUDOR ® STUDOR ® AUSTRALIA Presents The Introduction & Installation Course for the STUDOR ® Mini-Vent  Air Admittance Valve (AAV)
Joining, Installing, and Supporting Pipe
Introduction to (SMAW) Shielded Metal Arc Welding
Piping Materials Plumbing Systems CNST 305 Environmental Systems 1 Dr. Berryman 1bIntroduction – MaterialsChapter 1, 3; Appendix D (Wentz) and
Steel Piping Copper Tubing Other Materials
Casing Spacers & End Seals
Valves & Controls for Semiconductor Fabs Part 2 – Additional Products.
Unit 204: Common plumbing processes
STUDOR® AUSTRALIA Presents
Equipment Familiarization Amatrol 850 Basic Hydraulic Training System
Irrigation Pipe.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Asahi/America Multiport Valves
HEATING SYSTEMS AND SANITARY INSTALLATION OUT OF PP - R AGRUSAN.
Safe Facilities and Equipment
©2003, 2004, Plastics Pipe and Fittings Association Selecting the Proper Plastic Piping Material.
Asahi/America Type 21 Ball Valves Type 21 Ball Valves.
Compressed Air Piping Systems by Asahi/America
Plumbing Plastic Pipe Plumbing Systems 20091Plumbing.
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
Asahi/America Thermoplastic Check Valves Ball Check Valves ½” - 4”PVC, CPVC, PP, PVDF Uniseat/ Seal.
HVAC523 Circulator Pumps.
Chapter 22 Industrial Process Piping. Learning Objectives After completing this chapter, you will –Describe different types of pipe and their respective.
Residential and Commercial Plumbing Mr. Lemmons Ag Mechanics.
Ivy Tech Community College
Introduction to Plumbing Date. Bellwork 0 Fill out your KWL sheet about plumbing 0 What do you K now about plumbing? 0 What do you W ant to learn about.
Mazzei Injector Company, LLC
HVAC523 Piping and Fittings.
Plumbing Unit.
Poly Flo Piping System “The Double Wall Advantage” PolyFlo Double Containment Double Wall Integrity with Single Minded Purpose!
WORKSHOP PRACTICE SAFETY VALVE.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Bellwork Fill out your KWL sheet about plumbing Fill out your KWL sheet about plumbing What do you K now about plumbing? What do you K now about plumbing?
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
IDENTIFYING AND SELECTING PLUMBING MATERIALS AND FITTINGS Original Power Point Created by Von Peavy Modified by the Georgia Agriculture Education Curriculum.
Unit 209: Drainage systems
Unit 209: Drainage systems
Welcome! Drafting 2345: Advanced Pipe Drafting Andrew Amini Full Time Instructor, HCC.
Flammable Liquids Directorate of Training and Education
Welcome! Drafting 2323: Pipe Drafting Andrew Amini Full Time Instructor, HCC.
I-Purge ® MODULAR INFLATABLE BLADDER SYSTEM US & FOREIGN PATENTS ISSUED & PENDING CE APPROVED THE MOST VERSATILE & ADAPTABLE SOLUTION FOR PIPE PURGING.
Plumbing is the directing of the flow of water. Usually considered in two parts Fresh water supply Pipes, fittings, and fixtures that supply hot and cold.
Hazardous Energy Isolation (LOTO) Awareness Plus
Pipe specials.
THE SCIENCE OF SOLVENT WELDING
Chemical Engineering Drawing
High Density Polyethylene Pipe and Fittings
Asahi/America Multiport Valves
Plumbing Systems.
Welcome! Drafting 2345: Advanced Pipe Drafting
Asahi/America Multiport Valves
FUSION WELDING MATT W. BAKER STEPHEN G. HLOPICK SCOTT J. MORAVEK
THE SKINNER COMPANY Product Review
Piping.
Degassing Valve for Corrosive & Ultra-pure Liquids • Series DGV
Educational Technology
SCITEQ End closure series
Plastic Pipe and Fittings Association
CGThermal Umax® Advanced Ceramic Shell and Tube Heat Exchanger
Presentation transcript:

CHEM-VENT ®

The CHEM-VENT ® First ever AAV manufactured specifically for Acid Waste systems Material is NSF 014 and ASTM D-4101 compliant NSF certified to meet all performance standard of ASSE 1051 Designed and tested to operate in temperature up to 210º F High temp/chemical resistance EPDM sealing o-ring

The CHEM-VENT ® Simplify venting of ‘island sink’ chemical basins installations in Labs while providing proper and instant protection against negative pressure

MATERIAL Flame Retardant Polypropylene (FR-PP) The material of choice in Acid Waste for the last 20 years Excellent resistance to chemicals and solvents Capable of handling exothermic reactions Durable & easy to install

DESIGN FEATURE The CHEM-VENT ® is unlike any other AAV The CHEM-VENT ® is unlike any other AAV Purposely designed for Acid Waste systems installation Eliminates the need to measure in order to meet min. code lay length Direct mount on any molded FR-PP sanitary Tee Usable with either Mechanical Joint or Electrofusion FR-PP fittings Easily adaptable to CPVC, glass, PVDF or Duriron ® systems

DESIGN FEATURE Extended tail piece will always guarantee code compliance Tail piece guarantees that flow will never back up into the valve Patented Studor screen keeps ‘business end’ of the valve clean High chemical resistant EPDM O-ring is used

CONNECTING TO THE SYSTEM FR-PP & PP systems Will directly mount to molded sanitary Tees manufactured by: IPEX-GF/SLOANE-ORION-ZURN Electrofusion Preparation, assembly, clamping and machine programming shall strictly follow the fitting manufacturer instructions for a single (or multiple if other fittings are simultaneously welded) 11/2” pipe to fitting weld. Mechanical Joints Preparation (e.g. grooving) and assembly shall strictly follow the fitting manufacturer instructions for an 11/2” MJ pipe to fitting connection. In both cases no special equipment other than what supplied by the fitting manufacturer is required. 4”4” A D

CONNECTING TO THE SYSTEM CPVC systems ® The CHEM-VENT ® can be easily installed on molded sanitary Tees manufactured by: SPEARS – CHARLOTTE PIPE SPEARS (LabWaste ™ ) Using the special PP pipe adapter offered by this manufacturer. CHARLOTTE (ChemDrain ™) Solvent/cementing a small CPVC pup piece into the side socket of the Tee and then connecting that spigot to the valve’s tail piece with a no-hub coupling or special MJ adapter. ® The CHEM-VENT ® will meet or exceed operational temperature & chem. resistance parameters of CPVC systems A B C D 4”4”

CONNECTING TO THE SYSTEM GLASS systems ® The CHEM-VENT ® can be easily installed on borocilicate glass sanitary Tee manufactured by Schott or CheFlowtronics ® All that is needed to install The CHEM-VENT ® on a Kimax ™ (Schott) or Borodrain ™ (ChemFlwotronics) Tee is a glass/PP adapter offered by all FR-PP acid waste system manufacturers. ® ® Although the CHEM-VENT ® will easily meet most operational temperature & chem. resistance parameters of applications using glass, this may not always be the case. Studor should be consulted before a CHEM-VENT ® is installed on a glass system. A B C D 4”4”

CONNECTING TO THE SYSTEM GLASS systems The CHEM-VENT® can be easily installed on borocilicate glass systems A B C D 4”4” Electrofusion glass adapter MJ glass adapter

CONNECTING TO THE SYSTEM FR-PVDF systems Will directly mount to molded MJ sanitary Tees manufactured by: IPEX-GF/SLOANE-ORION-ZURN A B C D 4”4” ® ® Although the CHEM-VENT ® will easily meet most operational temperature & chem. resistance parameters of applications using FR-PVDF, this may not always be the case. Studor should be consulted before a CHEM- VENT ® is installed on a FR- PVDF system. ® The CHEM-VENT ® CANNOT BE USED IN PLENUM DESIGNATED AREAS.

CONNECTING TO THE SYSTEM FR-PVDF systems ® The CHEM-VENT ® can be easily installed on FR- PVDF systems A B C D 4”4” MJ FR-PVDF Sanitary Tee

CONNECTING TO THE SYSTEM DURIRON systems ® The CHEM-VENT ® can be easily installed on silicon/iron cast alloy systems A B C D 4”4” ® All that is needed to install The CHEM-VENT ® on a Duriron MJ or bell & spigot Tee is one of two adapters commercially available either through Duriron itself or all FR-PP acid waste system manufacturers. ® The CHEM-VENT ® will meet or exceed operational requirements (especially chem. resistance) of most systems using Duriron pipe & fittings.

CONNECTING TO THE SYSTEM DURIRON systems ® The CHEM-VENT ® can be easily installed on silicon/iron cast alloy systems A B C D 4”4” MJ PP adapter + No-hub coupling MJ adapter Score pipe; use asbestos rope or acid resistant oakum; caulk with hot led, led wool or caulking cement

SELECTION PARAMETERS The use of the CHEM-VENT ® is: Unconditionally recommended in Acid Waste systems when: FR-PP, PP, CPVC or DURIRON pipe & fittings are installed in Acid Waste systems when: Glass or FR- PVDF pipe & fittings are installed Conditionally recommended (consultation with Studor is required) in Acid Waste systems when: Glass or FR- PVDF pipe & fittings are installed Expressly not recommended in: Plenum rated areas or on systems which couldn’t be otherwise vented to open air without the use of filtration in order to retain organic or inorganic compounds which, if inhaled in the concentrations and proportions found inside the piping system, would be harmful to humans or animals.