CR The Glaucoma Tonometer. What sets it apart? Reichert’s 7CR Auto Tonometer + Corneal Response Technology takes corneal biomechanical properties into.

Slides:



Advertisements
Similar presentations
Technique Guidance Systems
Advertisements

A Wireless, Implantable Intra- Ocular Pressure Sensor for the Management of Glaucoma Gabriel Simon, M.D. Ph.D. Sept 16, 2008 ESCRS.
Scanning Tonometer for Eye Pressure (STEP™) Problem Measurement of eye pressure by Goldmann applanation tonometry is a technique first embodied in the.
Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Canadian Ophthalmological Society Evidence-based Clinical Practice Guidelines for the Management of Glaucoma in the Adult Eye.
Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Comparison of Endothelial Cell Count by Manual and Automated Methods in Normal Corneas and in Fuchs' Endothelial Dystrophy Somasheila I Murthy, Debarun.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Two dimensional elasticity mapping of partially cross-linked rabbit corneas using optical coherence elastography Jiasong Li 1, Manmohan Singh 1, Srilatha.
Recent Advances in IOP measurements
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.
Biomechanical Properties of Healthy and Keratoconic Corneas Evaluated Using an Ultra-High-Speed Scheimpflug Camera nznec Department of Ophthalmology University.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
SEI IOP and its correlations in a population based study in Central India. The Central India Eye and Medical Study. Krishna Bhojwani, Vinay Nangia, Jost.
The Canadian Association of Optometrists
Understand the Cornea Understand the Pressure
Outcome of refractive surgery in keratoconus suspect eyes
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Comparison of Orbscan and Ultrasound Pachymetry Measurements Faik Orucov, MD, Abraham Solomon, MD,Ziv Caspi, David Landau, MD, Eyal Strassman, MD, and.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.
TARIQ ALASBALI WHICH PATIENTS ARE AT RISK FOR THE PROGRESSION?
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Cataract Incision Fluid Ingress, an Engineering Analysis David S.C. Pao, M.D. Kristina Y. Pao, B.S. Erik A. Cheever, Ph.D. Cory Schroeder, B.S. David S.C.
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
In-vitro measurement of Intra- Ocular Pressure Alex Luce Undergraduate Research Symposium 2008.
Effect of Corneal Thickness on Selective Laser Trabeculoplasty to Decrease Intraocular Pressure as Primary or Secondary Treatment of Glaucoma ASCRS 2010.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Comparison of the Diaton Transpalpebral Tonometer Versus TonoPen- Applination Theodore H. Curtis, M.D.1, Douglas L Mackenzie, M.D.1, Robert J. Noecker.
Effect of Race on Selective Laser Trabeculoplasty  1st author has no financial interest in the subject matter of this poster.  2nd and 3rd co-authors.
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group e-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group Clinical.
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
Ocular Response Analyzer Waveform Analysis in the Ectatic Corneas: Correlation of the New Corneal Biomechanics Parameters and Severity of Keratoconus Kristin.
Effect of East Asian Race on Selective Laser Trabeculoplasty ASCRS 2011 Minerva Kim Johns Hopkins University Lawrence F. Jindra, MD Columbia University.
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
Mathematical Description of the Ocular Response Analyzer Applanation Signal in Post-LASIK Ectasia Mujtaba A. Qazi, M.D. 1,2 David A. Luce, Ph.D. 3 Jay.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Corneal Biomechanical Changes Following Surface Keratorefractive Surgery Teeravee Hongyok, MD, Christopher J. Rapuano, MD, Ajoy Virdi, MBBS, Elisabeth.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.
CRF variations ( initial CRF – final CRF )
Intraocular pressure & tonometry
55th ASMR National Scientific Conference
LSU Eye Center, New Orleans, LA
JP Deva COMPARISON OF PRELIMINARY RESULTS FROM CROSSLINKED KERATOCONUS AND NORMAL CORNEAE USING ORA JP Deva
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
Effects of corneal collagen crosslinking on Ocular Response Analyzer waveform-derived variables in keratoconus and post-LASIK ectasia Spatial treatment.
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
Bruno Valbon, Ana Caiado, Ricardo Louzada, Renato Ambrosio Jr *.
Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS)
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
The Effect of Corneal Thickness on Ocular Drug Penetration
Box and whiskers plot for bIOP, Goldmann applanation tonometry IOP (GAT) and Goldmann adjusted (GATAdj) in ocular hypertension (OHT), primary open-angle.
Presentation transcript:

CR The Glaucoma Tonometer

What sets it apart? Reichert’s 7CR Auto Tonometer + Corneal Response Technology takes corneal biomechanical properties into consideration, providing Corneal Compensated IOP (IOPcc) - a pressure measurement that is significantly less affected by the cornea than other methods of tonometry. The 7CR is based on Reichert’s patented dynamic bi-directional applanation technology, which is the foundation of the revolutionary Reichert Ocular Response Analyzer (ORA). The ORA is the first instrument capable of measuring corneal bio-mechanical properties and is supported by over 100 peer-reviewed publications in the medical literature. Corneal properties such as elasticity, viscosity, and thickness can affect the accuracy of Goldmann IOP values by as much as 17 mmHg in normal eyes and more than 20 mmHg in eyes with corneal pathology. The ORA, and now 7CR, are the only devices in the world that can account for these properties. IOPcc is patented technology (US 7, 481, 767 B2) Overview

The Glaucoma Tonometer What sets it apart? The 7CR presents you with a tremendous opportunity to sell a unique product that has strong clinical utility and essentially NO COMPETITION. 7CR is THE Glaucoma tonometer. This is not a screening device, as NCT’s were perceived to be in the past. 7CR should be positioned as the tonometer of choice for the management of glaucoma for ODs and MDs alike. The 7CR is superior to Goldmann or any other IOP measurement. Reichert 7CR Provides more clinically relevant tonometry measurements in: Normal Tension Glaucoma patients (subjects who have glaucoma but measure low on Goldmann) Primary Open Angle Glaucoma patients (typical high-pressure glaucoma subjects) Post-LASIK and refractive surgery patients (subjects with biomechanically altered corneas) Patients with Fuchs’ or Edema (very “spongy” corneas that measure inaccurately on Goldmann) Keratoconus patients (biomechanically weak corneas that measure inaccurately on Goldmann) Patients with thick, thin, or otherwise biomechanically atypical corneas Overview

The Glaucoma Tonometer Tonometry is used to measure the Introcular Pressure (IOP), which is a risk factor for Glaucoma. Higher IOP increases the risk for glaucoma. IOP is the ONLY modifiable risk factor for glaucoma. This means that once a patient has been diagnosed with glaucoma, the only thing doctors can do is try to lower the pressure. Regular monitoring of IOP is essential to determining efficacy of treatment in glaucoma patients. As such, accurate measurement of IOP is CRITICAL for the proper diagnosis and management of glaucoma. Tonometry

The Glaucoma Tonometer The Goldmann Tonometer has long been considered the gold standard for measuring pressure, but its accuracy is widely questioned today. Tonometry Goldmann Design Assumptions - Cornea is infinitely thin and perfectly flexible - Tear-film and corneal thickness effect cancel each other out Flaws - Experimentation done on cadaver eyes (not representative of live eyes) - Variations in corneal thickness is significantly greater than assumed - Variations in corneal biomechanical properties unaccounted for Accordingly, Goldmann cannot compensate for differences in thickness, elasticity, and other biomechanical parameters that influence accuracy

The Glaucoma Tonometer Can’t we calculate “true IOP” using pachymetry (CCT)? NO! Central Corneal Thickness based IOP adjustment algorithms DO NOT WORK. These formulas have been scientifically discredited and the glaucoma opinion leaders of the world are cautioning clinicians against using them. As such, CCT correction tables and pachymeters and tonometers that provide CCT-based “corrected” IOP values are OBSOLETE. Why CCT-based IOP correction is flawed “Correction nomograms that adjust GAT IOP based solely on CCT are neither valid nor useful in individual patients” - Pg 18. Robert N. Weinreb, James D. Brandt, David Garway-Heath and Felipe Medeiros World Glaucoma Association on Intraocular Pressure; Consensus Series 4; May 5, 2007

The Glaucoma Tonometer Why CCT-based IOP correction is flawed OHTS and other recent studies have investigated the relationship between central corneal thickness (CCT) and IOP values. They have found a relationship between CCT and GAT measured IOP. Thicker corneas tend to measure higher on GAT and Thinner corneas tend to measure lower. However, the relationship between CCT and measured IOP is only valid when observing large data sets. When applied to individual patients, corneal thickness IOP “correction” formulas present a 40% chance of adjusting the IOP in the WRONG DIRECTION!

The Glaucoma Tonometer Why CCT-based IOP correction is flawed Data courtesy New England College of Optometry Very thin corneas tend to measure low IOP Very thick corneas tend to measure high IOP But SCATTER in the data makes accurate mathematical “adjustment” of IOP impossible for individuals!

The Glaucoma Tonometer Thick and thin is WRONG. Think weak and strong Why CCT-based IOP correction is flawed Corneal Resistance to bending is not dependant thickness, but on material properties

CR The Glaucoma Tonometer The 7CR IOPcc measurement is not based on the overly-simplistic Corneal Thickness “correction” approach. 7CR quantifies the cornea’s biomechanical properties, and then reduces the effect of these on the IOP measurement process

The Glaucoma Tonometer Dynamic Bi-Directional Applanation Goldmann and other tonometers only determine one number, but they are affected by two things: IOP and cornea. You can’t measure two things with one number! The 7CR makes a ‘dynamic’ measurement, monitoring the in/out movement of the cornea in response to a rapid air impulse. The Bi-Directional Applanation results in two IOP measurements in rapid succession (one as the cornea moves in, and one as the cornea moves out). This permits determination of corneal properties, enabling the 7CR to provide a more accurate IOP measurement.

The Glaucoma Tonometer Dynamic Bi-Directional Applanation Undisturbed Cornea IR Light Emitter IR Light Detector Auto alignment is achieved. instrument is ready to measure

The Glaucoma Tonometer Dynamic Bi-Directional Applanation Air-Jet Applanated Cornea IR Signal Peak Air pulse is delivered, inward applanation is recorded

The Glaucoma Tonometer Dynamic Bi-Directional Applanation Corneal Concavity Air-Jet Cornea passes through applanation into mild concavity

The Glaucoma Tonometer Dynamic Bi-Directional Applanation IR Signal Peak Air-Jet Applanated Cornea IR Signal Peak Air pulse reduces, cornea returns, outward applanation is recorded

The Glaucoma Tonometer Dynamic Bi-Directional Applanation Undisturbed Cornea IR Light Emitter Air tube IR Light Detector Measurement process complete

The Glaucoma Tonometer Applanation Signal Plot 7CR Measurement Signal Inward Applanation Outward Applanation Corneal Hysteresis

The Glaucoma Tonometer Hysteresis A property of materials or systems that do not instantly follow forces applied to them, but react slowly, or do not return completely to their original state. The phenomenon was identified by Sir James Alfred Ewing in This term is commonly used to describe material properties in engineering and architecture. Corneal Hysteresis (CH) A characterization of the cornea’s biomechanical tissue properties. It is a result of visco-elastic damping (energy absorption) as the cornea moves rapidly in and out. This is what enables the 7CR to quantify and minimize the cornea’s influence on IOP measurement. Discovered by Dr. David Luce of Reichert Inc

The Glaucoma Tonometer Hysteresis Many common visco-elastic materials and systems exhibit hysteresis. - Automotive struts - Foam mattresses - Viscous fluids like honey and oil - Door dampers (closers) The Cornea is visco-elastic like these examples

The Glaucoma Tonometer IOPcc Corneal-Compensated Intraocular Pressure IOPcc is patented technology (US 7, 481, 767 B2) 7CR utilizes the information provided in the Corneal Hysteresis measurement to determine IOPcc, which is less affected by corneal properties than other methods of tonometery, such as Goldmann (GAT). 7CR also provides “IOPg” which is similar to an actual Goldmann measurement. Seeing these values simultaneously gives clinicians a better understanding of patient tonometry values.

The Glaucoma Tonometer IOPcc Corneal-Compensated Intraocular Pressure IOPcc is still a Goldmann correlated IOP measurement. It agrees with Goldmann on average, but is not influenced by the cornea in the same way as Goldmann and other tonometers are. Therefore IOPcc has the same “scale” as a Goldmann measurement, but is more clinically relevant because it is not contaminated by corneal artifacts. Note: The PASCAL DCT, which claims independence from corneal properties is NOT Goldmann correlated. As such, the clinical relevance of the DCT IOP measurement is questionable.

The Glaucoma Tonometer 7CR IOPCC vs CCT 184 Normals Data courtesy New England College of Optometry IOPcc is not influenced by the thickness of the cornea

The Glaucoma Tonometer Data courtesy Dr. David Castellano, MD / Dr. Jay Pepose, MD 28 eyes Pre/Post LASIK IOPCC IOPcc “ignores” the change in corneal properties cause by LASIK and provides similar IOP measurements in pre and post refractive surgery subjects IOP appears to be lower after LASIK with Goldmann

The Glaucoma Tonometer Is IOPcc Better than GAT?

The Glaucoma Tonometer Evaluation of the Influence of Corneal Biomechanical Properties on Intraocular Pressure Measurements Using the Ocular Response Analyzer. Felipe A. Medeiros, MD and Robert N. Weinreb, MD J Glaucoma 2006;15:364–370. Clinical Publications Conclusions: IOPg agrees with Goldmann very well. IOPcc seems to provide an estimate of IOP that is less influenced by corneal properties than those provided by GAT IOPg, IOPcc correlation with Goldmann and CCT GAT IOPcc

The Glaucoma Tonometer Clinical Publications Ocular Response Analyzer in Subjects with and without Glaucoma. Sullivan-Mee M, Billingsley SC, Patel AD, Halverson KD, Alldredge BR, Qualls C. J Optom Vis Sci Jun;85(6): In Glaucomatous eyes IOPcc was significantly higher than GAT. This relationship was also true in Glaucoma suspects. However, in normal eyes and OHT eyes, IOPcc, IOPg, and GAT were all similar. This indicates that IOPcc is a better indicator of glaucoma presence IOPcc differentiates Glaucomatous Eyes

The Glaucoma Tonometer Intraocular pressure measured by dynamic contour tonometer and ocular response analyzer in normal tension glaucoma Tetsuya Morita & Nobuyuki Shoji & Kazutaka Kamiya & Mana Hagishima & Fusako Fujimura & Kimiya Shimizu Graefes Arch Clin Exp Ophthalmol DOI /s Clinical Publications Conclusions: Only IOPcc was able to distinguish the NTG eyes from the true normal eyes. IOPcc can differentiate NTG eyes from normal eyes True normal eyes and eyes with NTG (normal tension glaucoma) were measured with GAT, DCT, IOPg, and IOPcc

The Glaucoma Tonometer Summary of IOPcc advantages IOPcc correlates strongly with GAT on the average HOWEVER, IOPcc has the following advantages over GAT Not affected by CCT Not affected by corneal biomechanical properties (rigidity) As such, it is more accurate in KC, Fuchs’, OHT, NTG eyes In addition, it has less measured IOP reduction post-LASIK No operator bias

The Glaucoma Tonometer Important Service Note: 7 CR cannot be calibrated using rubber eyes like previous generation Reichert tonometers. A device called a TCT (Tonometer Calibration Tool) must be used. Service and calibration training will be provided at another time