SLHC-PP – WP7 Critical Components for Injector Upgrade Plasma Generator – CERN, DESY, STFC-RAL Linac4 2MHz RF source Thermal Modeling Gas Measurement and.

Slides:



Advertisements
Similar presentations
of LFD Compensation Study S1 Global Cryomodule
Advertisements

Overview of SMTF RF Systems Brian Chase. Overview Scope of RF Systems RF & LLRF Collaboration LLRF Specifications for SMTF Progress So Far Status of progress.
Lorentz force detuning measurements on the CEA cavity
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
Juliette PLOUIN – CEA/SaclayCARE’08, 3 December /21 Superconducting Cavity activities within HIPPI CARE ‘08 CERN, 2-5 December 2008 Juliette PLOUIN.
Tuning system requirements
Cell-Coupled Drift Tube Linac M. Pasini, CERN AB-RF LINAC4 Machine Advisory Committee 1 st meeting CERN January 29-30, 2008.
Possible Assembly and Test of the Crab cryomodule in SM18 at CERN P. Maesen LHC Crab Cav meeting, 17 Sep’ 09 LHC-CC09Cryomodule Assembly & Test Stand.
Superconducting Accelerating Cryo-Module Tests at DESY International Workshop on Linear Colliders 2010 (ECFA-CLIC-ILC Joint Meeting) Denis Kostin, MHF-SL,
Cavity design Fundamental parameters : frequency, beta, number of cells (gaps), Eacc Optimisation : R/Q, surface fields / Eacc, Qex, damping of HOMs, kloss,
HYBRIS: R. Keller Page 1 A Hybrid Ion Source Concept for a Proton Driver Front-End R. Keller, P. Luft, M. Regis, J. Wallig M. Monroy, A. Ratti, and.
SRF Results and Requirements Internal MLC Review Matthias Liepe1.
E. KAKO (KEK) 2010' Sept. 10 KEK Global Design Effort 1 Lorentz Force Detuning Eiji Kako (KEK, Japan)
ESS cavities interfaces
Test Stands Roger Ruber Uppsala University ESS TAC4 16 Feb
S1G Experiment Schedule Plan H. Hayano. Assembly work after cavity arrived Assumption: cavity with VT, with pickup antena, with Ar or N2 filled,
R Scrivens – sLHC-PP annual meeting Feb 2010 SLHC-PP – WP7 Critical Components for the SLHC injectors (SPL) 7.1 Plasma Generator for a SPL ion source (J.
TTF-II Status & Prospectives Nick Walker DESY 5 th ITRP Meeting – CALTECH.
XFEL SRF Accelerating Module Prototypes Tests at DESY Fermilab Seminar, July 21st Denis Kostin, MHF-SL, DESY.
LLRF-05 Oct.10,20051 Digital LLRF feedback control system for the J-PARC linac Shin MICHIZONO KEK, High Energy Accelerator Research Organization (JAPAN)
Recent LFD Control Results from FNAL Yuriy Pischalnikov Warren Schappert TTF/FLASH 9mA Meeting on Cavity Gradient Flatness June 01, 2010.
Development of an H - plasma generator for SPL Matthias Kronberger, CERN BE/ABP-HSL SPL collaboration meeting, 2010/11/25.
S.Noguchi (KEK) ILC08 Chicago , Nov . 17, Cavity Package Test in STF STF Phase-1 E. Kako, S. Noguchi, H. Hayano, T. Shishido, M. Sato, K. Watanabe,
1Matthias LiepeAugust 2, 2007 LLRF for the ERL Matthias Liepe.
RF Development for ESS Roger Ruber and Volker Ziemann Uppsala Universitet 4 Dec Dec-20091RR+VZ: ESS RF Development.
W. 3rd SPL collaboration Meeting November 12, 20091/23 Wolfgang Hofle SPL LLRF simulations Feasibility and constraints for operation with more.
Anders Sunesson RF Group ESS Accelerator Division
Marc Ross Nick Walker Akira Yamamoto ‘Overhead and Margin’ – an attempt to set standard terminology 10 Sept 2010 Overhead and Margin 1.
W. 5th SPL collaboration Meeting CERN, November 25, 20101/18 reported by Wolfgang Hofle CERN BE/RF Update on RF Layout and LLRF activities for.
Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,
Revised SPL-study work-plan W. Weingarten 3 May 20101SPL Cavity WG Meeting.
S1G Experiment Schedule Plan; H. Hayano ILC10 GDE meeting.
ESS LLRF and Beam Interaction. ESS RF system From the wall plug to the coupler Controlled over EPICS Connected to the global Machine Protection System.
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
SLHCpp 3rd Annual Meeting Feb 7-8, 2011 reported by Wolfgang Hofle SLHCpp Work Package 7 “Critical Components for Injectors” Status February 2011 Participation.
Eric Montesinos - CERN - First SPL collaboration meeting - CERN December 11th 2008 First SPL collaboration meeting Experience with the LHC Main power Coupler.
CARE SC meeting August 2005 T. Garvey JRA1 – SRF (WP 7 – 11)
R.SREEDHARAN  SOLEIL main parameters  Booster and storage ring low level RF system  New digital Booster LLRF system under development  Digital LLRF.
CHARGES TO THE ESAC The External Scientific Advisory Committee for the HIPPI JRA inside CARE has been nominated to analyse the work done and planned in.
JRA1 – SRF report CARE Steering Committee meeting,
SPL waveguide distribution system Components, configurations, potential problems D. Valuch, E. Ciapala, O. Brunner CERN AB/RF SPL collaboration meeting.
High power RF tests places at CERN O. Brunner, CERN 4th SPL Collaboration Meeting jointly with ESS.
SLHC-PP WP7 8 April 2008 Structure SLHC- PP WP7 SLHC-PP Steering Group SPL Study Group DESY Peters INFN ? CERN Scrivens / Hofle STFC- RAL Faircloth CEA.
Detail plan of S1-Global H. Hayano (KEK),
ESGARD – OMIA 10 & 11/09/2007 JRA on Sc cavities and Cryomodule for a Pulsed proton Linac Motivation Work Packages Partners & resources R. Garoby for S.
Preparation procedure and RF processining of cERL-ML power coupler at KEK Hiroshi Sakai, Takaaki Furuya, Masato Sato, Kenji Shinoe, Kensei Umemori, Kazuhiro.
Overview of long pulse experiments at NML Nikolay Solyak PXIE Program Review January 16-17, PXIE Review, N.Solyak E.Harms, S. Nagaitsev, B. Chase,
1 Tuner performance with LLRF control at KEK Shin MICHIZONO (KEK) Dec.07 TTC Beijing (Michizono) S1G (RDR configuration) - Detuning monitor - Tuner control.
11/12/2013P. Bosland - AD-retreat - Lund Designs of the Spoke and Elliptical Cavity Cryomodules P. Bosland CEA/Saclay IRFU On behalf of the cryomodule.
H-ECCTD KICK-OFF DESCRIPTION AND CHALLENGES 16/03/2016 F. PEAUGER.
SRF Cavities Resonance Control. CW mode of operation (FNAL’s experience). Yu. Pischalnikov W. Schappert FNAL TTC CW SRF Meeting, Cornell University, 12June,
ESS SC cavities development G. Devanz TTC meeting, march 1st 2011, Milano.
ESS LLRF and Beam Interaction
Areal RF Station A. Vardanyan
S1G Experiment Schedule Plan
Test of the dressed spoke cavity
WP5 Elliptical cavities
Power Couplers, HOM Couplers and Tuners for the XFEL
TTC Topical Workshop - CW SRF, Cornell 12th – 14th June 2013
Test plan of ESS HB elliptical cavity
Cavity resonance control
Wolfgang Anders, BESSY, Berlin
CW Operation of XFEL Modules
Superbeams with SPL at CERN
Review of the European XFEL Linac System
CW accelerating module test progress at DESY
High gradients in TESLA nine-cell cavities
First High Power Test of the ESS Double Spoke Cavity package
Facility for Research Instrumentation and Accelerator Development
Presentation transcript:

SLHC-PP – WP7 Critical Components for Injector Upgrade Plasma Generator – CERN, DESY, STFC-RAL Linac4 2MHz RF source Thermal Modeling Gas Measurement and Modeling SPL test area Low Level RF – CEA, CERN, INFN  =0.5 sc cavities RF measurement system RF simulation

The Linac4 source Spectrometer magnets Electron dump Ferrites Confinement magnets Collar and plasma feedthrough

Thermal model of the Linac4 source. Assumptions made: All power (100kW peak) is delivered into the plasma (worst case). This power is delivered uniformly to the internal walls of the source. (No plasma modeling is included). Outer cooling is ambient air cooling and radiation (low). Internal surfaces in vacuum are radiation cooled.

At Linac4 power: Collar temperature is high, (assumptions lead to high power to the collar, which is thermally isolated). Other temperatures are serviceable for the materials used. Plastic magnet cage gives a low thermal conductivity to outside. At SPL power: Several materials above their service temperature. All magnets/ferrites above Curie temperature.

Deliverables Finite element thermal study of the Linac4 design source at the final duty factor Report M12 Deliverable report being written. Next stages to progress to milestone: Introduce cooling systems in critical and accessible regions. New materials (AlN for chamber, and similar cooling sleeve – a la SNS). Critical point is the collar and plasma electrodes Design of a high duty factor plasma generator Report M18 Follows on from milestone.

1.6V ^6 10^-3 hPa ^4.5 mTorr 1.05V ^ ^-3 hPa ^ 3.2 mTorr p plasma chamber Measurements made on the source gas pressure (plasma chamber). Variation from 3.2 to 4.5 mTorr seen, decay time is ~1.5s. (<2% of pressure decay after 20ms). Rise time is also ~20ms.

Model based on conductance between different volumes. Gives good agreement under certain assumptions. Measured data and model

PhD student – First 50 Hz operation on CERN’s Linac-4 test stand of the non-cesiated Desy RF volume H- source. – Computing gas flow through the source from pulsed gas injection, to continuous flow.

SLHC-Plasma Chamber test rooms 357-R-005 & 357-R-011

Low Level RF Task 7.2 Preparation of the cavities, coupler and cryostats for tests. Preparation of the measurement systems. Simulation techniques for the RF for SPL.

Objective of the tests:  Study and development of a correction algorithm of the Lorentz Force Detuning able to limit the variation of the phase during the beam pulse in order to achieve the required field stability (amplitude and phase) with limited power margin.  Implementation and measurement in pulsed mode on a real sc cavity Measurement of the Lorentz Force Detuning in CW mode

P klystron P flat 4xP flat  cav ln 2 4  ×  cav ln 2 flat top generation time V cavity Pulsed mode leads to a high power to quickly ramp up the cavity field, and supply power to the beam (230kW). Additional difficulty will be the mechanical modes excited by the Lorentz Force Detuning. At 50Hz operation, these mechanical modes will not damp down fully between pulses. Operation of the cavity  =0.47 in pulsed mode Filling time=300  s, flat top=1ms, frep=50 Hz Qex = , Eacc= 13MV/m  4xPflat=230 kW

From CARE/HIPPI (FP6) 704 MHz 5cells beta=0.5 cavity (SPL requires 0.65, 1) Valid for stability tests. after welding of LHe tank

Verification of field flatness after installation into the tank. INFN cavity has been enclosed in internal magnetic shielding and He tank.

CryHoLab (horizontal cryostat) has cavity installed. Ready for connection to the 700MHz high power klystron and fitted with power coupler. Klystron tested, 1.2MW cw achieved. Can work at 50Hz, 2ms pulsed mode, reduced power (HV limitations at the moment). Coupler is built, and under processing towards full power for SPL.

Tune State of cavity can be calculated from RF forward and antenna signals. Scheme of set up based on LHC LLRF and tuning electronic module Set up built (at 700MHz) for testing. Now using stand alone server. To go to CEA Saclay.

Vector modulator Vector modulator Vector modulator Vector modulator LLRF Vector SUM Klystron Feedback Example RF layout for SPL 4 cavities per klystron. Simulate how this system behaves with LFD (but no active LFD compensation). Piezo

Vector Sum Cavities ±3% ±4° Example (to illustrate what the simulation can calculate) of how the system behaves with different LFD constants per cavity.

Deliverables In depth characterisation of the two tuners plus cavities developed in the frame of the “HIPPI” JRA, FP6 In order to properly achieve this deliverable, more time is required. 6 months to complete assembly, 3 months for testing. Second cavity will also require additional 3 months Design of RF system architecture including modeling of RF components, simulation of the RF system and simulation of beam dynamics of the full Linac; RF system and high power modulator specifications R M18 Requires input from the deliverable above Production of a prototype electronic system and other elements for a full system demonstration; Definition of demonstration procedure P M30 Work has been started and progressed well in order to make a measurement system for 7.2.1

Summary Plasma Generator/Source Thermal modeling and design started. Gas calculations started. First deliverables are within reach. LL RF Test stand is ready (Klystron, cryostat…) First deliverable being rescheduled following HIPPI. Confident we can achieve the program.

Plasma Spectral analysis & temperature measurement Linac-4 ion-source SPL-plasma Chamber