HCAL Laser Upgrade Study German Martinez Florida International University Vasken Hagopian Florida State University.

Slides:



Advertisements
Similar presentations
D e t e c t o r s f o r H P L C.
Advertisements

Chromatic Dispersion Measurement methods  Pulse Delay Method (time-of-flight) ‏ IEC / ITU-T G650.1 EIA/TIA-455- FOTP-175-B  Phase Shift Method.
May Chuck DiMarzio, Northeastern University ECE-1466 Modern Optics Course Notes Part 9 Prof. Charles A. DiMarzio Northeastern University.
DYE LASERS Mehmet Mustafa KARABULUT. TABLE OF CONTENTS 1. Working Principles 2. CW and Pulse Modes 3. Applications 4. Properties 5. Recent.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Class 3b Special Precautions examples (insert below at position 1 on sign): 1. Laser protective eyewear required 2. Invisible laser radiation 3. Knock.
Dr. Ali Saad/ biomedical technology KSU 1 Medical L-A-S-E-R Ali S. Saad Department of Biomedical Engineering College of applied medical Sciences King Saud.
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
Phys 102 – Lecture 25 The quantum mechanical model of light.
Integrated Optic Components  Passive: Requires no input power, like directional couplers, beam splitters, isolators, filters, lenses and prisms  Active:
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology On behalf othe CMS ECAL Collaboration High-resolution, high-granularity.
Fiber-Optic Communications
Pump Probe Measurements of Femto-second Pulses By David Baxter.
Part A: Controlling Oscillation Frequency with Capacitors and Resistors Part B: Diodes and Light Experiment Timer.
MB1 T.O.F. II Precise timing Electron ID Eliminate muons that decay Tracking devices T.O.F. 0 & I Pion /muon ID precise timing 201 MHz RF cavities Liquid.
Liquid Helium Scintillation T. Wijnands EN/HDO Candidate for detecting beam losses in the LHC ?
LIBS Detector System Design & Preliminary Testing David Hahn, Tom Moskal, Ken Iida Department of Mechanical Engineering University of Florida July 9, 2001.
Sep 13, 2007CALICE Collaboration Meeting Prague 1 Long term test of LED pulsing  Long LED system stability measurement  Aging of part of optical system.
WP06_AntennaIF. WP06_AntennaIF 3 principal modules switch amplifier (= ATA ‘PAM’) –includes attenuators (0-60 dB), power detector, and bias tee for the.
CMS UPGRADE CAPILLARY TUBE PROFILING. CAPILLARY TUBES EVALUATION Radiation damage Transmission Mixing Scintillating Quartz Tube Water/ Air EJ309 Fiber.
1 HF Laser/LED Calibration Studies L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH 1->9 light splitter w/ pulsed.
Marc Baarmand Total of 8 Calibration Boxes (CBOX) for HF  CBOX contains Small blue scintillator (UV → blue) 1×9 Splitter (each CBOX serves 9 PMT RO Boxes)
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
MPPC R&D status Kobe Univ. CALICE collaboration meeting Yuji SUDO Univ. of Tsukuba ~ contents ~ Introduction Linearity curve Recovery time.
1 TOF Aging Discussion Background information Summary of results so far Examples of gain loss mechanisms Diagnostics Possible scenarios for 2006 Discussion.
Biomedical Applications of Plasma Spectroscopy: A Preliminary Study Dr. Unnikrishnan V. K. Associate Professor Department of Atomic and Molecular Physics.
Ion Source Update. We now have 2 running sources Source B has been running since the first part of June Both sources have been modified extensively since.
October 2002US CMS HCAL at BU1 US CMS HCAL Meeting Boston University Vasken Hagopian Florida State University.
Motivation There is a consensus that it is not possible to obtain a software (π 0 ) calibration with few days delay (this is to be verified, this is the.
Amsterdam 29 March 2011 Fernando Urbano IFIC (CSIC – Universidad de Valencia) KM3NeT Optical Calibration Laser Beacon and Nanobeacon Status.
N 2 Laser 300  QQ 150m HF  HF + 9 PMT Boxes  QP Calib Box 1  4 Counting Room HF Calibration Optical Fiber Path 9 PMT Boxes / Quad 24 PMT Tubes.
Femto-second Measurements of Semiconductor Laser Diodes David Baxter
Simple Multiwavelength Time-Division Multiplexed Light Source for Sensing Applications Thilo Kraetschmer and Scott Sanders Engine Research Center Department.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH.
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
Thoughts on the Design of a WVR for Alan Roy (MPIfR) the Twin Telescope at Wettzell.
HBD Gas and QE Monitoring Craig Woody BNL HBD Working Group Meeting October 19, 2005.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Optical Amplifiers By: Ryan Galloway.
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
HB LED Pulser Boards By Michael Miller The University of Iowa.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
HF 2008 : Status and Plans CMS Week, February 2008 Aldo Penzo HCAL Commissioning Status (INFN-Trieste, Italy) (23 February 2008)
E. A. Albayrak, HCAL Meeting, Fermilab, Nov HE CALORIMETER DETECTOR UPGRADE R&D STATUS E. A. Albayrak for The University Of Iowa Fairfield University.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
Main HCAL, JUL1,2008Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers HCAL main meeting, DESY.
1 Overview of the HCAL LED monitoring PRR note CALO meeting Anatoli Konoplyannikov ABSTRACT In this note the design and integration of the LED.
H C A L 11 th International Conference on Advanced Technology and Particle Physics Villa Olmo (Como - Italy), October 5 - 9, 2009 THE PERFORMANCE OF THE.
PMT Tests for HF Upgrade Ugur Akgun. HF PMT Proposed Tests On Every PMT: – Rise Time – Negative Pulse Width – Transit Time – Transit Time spread – Single.
Timing System R+D for the NLC Josef Frisch. NLC and PEPII Phase and Timing Requirements (approximate)
Transmission Measurement Basic Outline. Transmission Curve Describes the percentage of a signal that is transmitted through an object (filter) over a.
Development of a High Resolution Cavity BPM for the CLIC Main Beam
PMT time offset calibration (not completed) R.Sawada 27/Dec/2007.
An H- stripping laser using commercial, diode-pumped Nd:YAG amplifiers Russell Wilcox Laser Stripping Workshop, April 11, 2011.
Iowa PMT Test Station Ugur Akgun 1. HF PMT Proposed Tests On Every PMT: – Rise Time – Negative Pulse Width – Transit Time – Transit Time spread – Single.
E.Gushchin,S.Filippov(INR,Moscow) 16 April 2008Calo commissioning meeting CERN PS/SPD LED monitoring system status General status LED signal is used for.
Brenda Dingus Jan 2005 New Laser Calibration Status  New Laser vs Old Laser  Safety  Pond Data  Outrigger Data  How to Combine?
DECam Spectrophotometric Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
UNIT-3 ADVANCES IN METROLOGY
Pulse energy measurement for the CTF lasers.
8.2.2 Fiber Optic Communications
INTRODUCTION TO OPTICAL COMMUNICATION TECHNOLOGY
DANGER Class 3b laser (Position 1) (Position 2)
On behalf of the Caltech Laser Group
C.F. Feb
C.F. Feb
PRINCIPLE AND WORKING OF A SEMICONDUCTOR LASER
Presentation transcript:

HCAL Laser Upgrade Study German Martinez Florida International University Vasken Hagopian Florida State University

Present Laser Nitrogen; pulsed; 337 nm and 300 µJ when new. Long time delay between pulse and laser light. Time jitter can be as high as 20 nsec Lifetime (30% drop in intensity) in 20 million pulses. Uses. 1.Pulses to HPD’s and PMT’s for time and gain calibration. 2.Pulses to scintillator Megatiles (HB and HE Radiation damage studies) 3.HF RADDAM (an after thought) 4.ZDC (another after thought). 5.Not yet Castor …

Present Laser Distribution and conversion. – Filters wheels and a moving stage control the light level output and the detector to which the light is sent. – Light splitters at the laser room and on the detector side distribute the light to the different components – Laser UV light is converted to an appropriate wavelength in each case Green light for HPD’s Blue light for PMT’s and HF RADDDAM Direct UV for Megatiles – Wide range of light levels required. i.e HPDs need 10 3 less light than Megatiles, HFRADAM. – Note: The conversion is done in the Calibration Boxes for HPD’s and the HF PMT’s through appropriate scintillators. Changing the laser wavelength may require to modify all the Calibration Boxes if the scintillators are not excited by a new wavelength.

Problems with present laser system Three laser units (+2 lower power) in stock but: – the manufacturer no more in nitrogen laser business Time jitter is significant and changes from laser to laser and with aging. Occasional firing without external signal prevent its use during abort gap. High intensity needed for HF RADDAM bleaches the wavelength shifter scintillator.

Laser upgrade options 1.Replacement of the current laser by a similar laser of another manufacturer – Moderate costs, even for more powerful lasers i.e. 1mJ pulse laser: 15,000 U$D (Not sealed unit) – Would require minimal changes (mechanics) – Could use a dye in a dedicated laser instead of wavelength shifter to solve the HF RADDAM bleaching problem – Jitter and misfiring will probably still be a problem.

Laser upgrade options 2) Q-switched Solid lasers Wide range of options (wavelength, power, pulsing length) in the market. – Minimal jitter – Relatively expensive (i.e. 50uJ/pulse Blue laser 35,000 U$D) – Will need at least two types (blue and UV). – May need to redesign the laser table optics. – May need to redesign HF calibration boxes.

Laser upgrade options 3) Laser Diodes Low cost high power diode lasers are now on market. – i.e. 1 watt CW blue laser cost ~ $ 3̄00. 1 Watt blue laser (~450 nm) would have enough power in 10 nsec for RADDAM (no wavelength shifter needed). Low cost of laser diodes could allow the use different diodes for different detectors. Lower power UV diode lasers exist. Not yet powerful enough for Megatiles. Do not yet know if we can pulse it with 10 nsec signal. Can they be easily focused to a 250 μm fiber? Engineering costs (pulsers, optics, calibration boxes) may be significant.

One (1) watt blue laser Q Switched UV Laser 355 nm 100 micro joule per pulse

What have we done so far Survey market. Several of the diode lasers came to the market during the past several months. Ordered three 100 mW continuous wave lasers at FNAL (about $32 each). Sergey Los at FNAL will try to pulse these lasers.

PLANS and costs Provide two separate laser systems. There are Q-switched lasers on the market but cost about $ 35,000 (would need at least 2). New diode lasers that can be pulsed (Nichia) cost about $ 3,500 each. New Q switched laser (from China) may be possible (?) Put RADDAM diode lasers in HF (2 units; one each HF). In each case pulser have to be (re)built. (Engineering and manufacturing). Developments are too new and will have better knowledge in three months!