Large Cell Scope Pictures HV Gnd 1nF Large Cell Tube Anode signal Cathode signal scope S1 S2 S1 S2 The following scope pictures were all taken with the.

Slides:



Advertisements
Similar presentations
Coolidge X-ray Tube. + High voltage - Anode cathode Cooling fins A Vacuum Low ac voltage Gas envelope A X-rays.
Advertisements

Geiger Counters. Higher Voltage As the voltage increases in a gas detector the ions collected increases. The proportional region ends. –Streamer mode.
1 Jim Thomas - LBL A Brief Introduction to the STAR Time Projection Chamber Jim Thomas Lawrence Berkeley National Laboratory June 4 th, 2009.
Assembling a Functional Multi-Wire Proportional Counter - Page 1 Work in pairs. One person will take the chamber apart, and the other will reassemble it.
TPC Proposal for the 35 Ton Liquid Argon Test Abstract We propose to equip the 35 ton cryostat with one APA and two CPA’s, and all the necessary equipment.
E0’ setup at CERN, , lab 187-R-D06, via bat 70, tel Is there a sock over the umbilical - if so how connected to chassis. and how far does.
We begin by subtracting noise (run flash lamp without HV) from signal (run flash lamp with HV) In the above for the cathode, we subtract the brown noise.
D. Peterson, “The Cornell/Purdue TPC”, LCWS05, Stanford, 21-March The Cornell/Purdue TPC Information available at the web site:
D. Peterson, “ILC Detector Work”, Cornell Group Meeting, 4-October ILC Detector Work This project is supported by the US National Science Foundation.
D. Peterson, “The Cornell/Purdue TPC”, ALCPG, Snowmass, 23-August The Cornell/Purdue TPC Information available at the web site:
RF test of the GEM detector prototipe Detector description RF test area (LINAC3) detector working conditions RF field measurement Detector measurements.
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
Original image: 512 pixels by 512 pixels. Probe is the size of 1 pixel. Picture is sampled at every pixel ( samples taken)
1 ME 234/2 HV noise investigation N.Bondar CMU. 12/18/02.
Straw tube measurements Sebastian Bablok, Øystein Djuvsland, Per Thomas Hille.
RPC system cable routing Yang Changgen, Guan Mengyun IHEP, Beijing.
Tests of a 10cm by 10cm triple GEM detector
Large Cell Scope Pictures, Part II HV Gnd 1nF Large Cell Tube Anode signal Phi Cathode signal scope S1 S2 S1 S2 This is a follow-up on Richard’s measurement.
Space The elements of art.
TAU - status December 14. Lab setup 9/7/2011TAU - status report2 Each RO line is X100 Attenuated and 100Ω terminated 10 μm position precision of collimated.
GEM progress from Chinese collaboration Yuxiang Zhao University of Science and Technology of China Aug 20,
BigBite Wire Chamber Test Xin Qian Duke University Feb 20th For TRANSVERSITY Collaboration Wire chamber Gas Cerenkov Shower system Scintillator Magnetic.
Malte HildebrandtDC Status Report, Dear MEG Committee,PSI, April 14 th 2009 this is the first report concerning the drift chamber status as.
Linear Collider TPC R&D in Canada Bob Carnegie, Madhu Dixit, Dean Karlen, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer, Alasdair Rankin,
QUPID Readout and Application in Future Noble Liquid Detectors Kevin Lung, UCLA TIPP 2011 June 11, 2011.
GAMOS tutorial X-ray Exercises
1 Jim Thomas - LBL New Pad Plane Design Proposal & Specifications Jim Thomas, John Hammond, Bob Scheetz, Jon Wirth, etc., etc., and a cast of thousands.
S-2S memo WC Toshiyuki Gogami 24Apr2015.
Prototypes For Particle Detectors Employing Gas Electron Multiplier
NanoPHYS’12 – December 17-19, 2012 K. Nakano, S. Miyasaka, K. Nagai and S. Obata (Department of Physics, Tokyo Institute of Technology) Drift Chambers.
And now for something completely different First results from the DC-DC Stavelet Peter & Ashley with Giulio & John.
Malte Hildebrandt, PSIMEG - Review Meeting / 1   e  Drift Chambers Charge Division Test Chamber Testsetup for Cosmics Chamber Construction.
The LNF test setup Status as of Geometry of LNF setup Top and bottom trigger counters 4 KLOE-type tracking chambers One BESIII-(COMPASS-)type.
E-Cal Readout Boards - 8 Boards total -Design & Fabrication at Jlab - Assembly at Orsay Nick Nganga HPS Collaboration Oct Jlab.
24/05/2010Rui De Oliveira1 Resistive protections for Bulk Micromegas Rui de oliveira, Joerg Wotschack Venetios Polychronakos.
cm 150 cm The Al foil is large as the M3 wall  we can put 1 raw (5 chambers) or 2 raws There is an insulating material (varnish) on the.
长读出条 MRPC 性能研究 孙勇杰 Key Laboratory of Technology of Particle Detection and Electronics, USTC-IHEP, CAS Center of Particle Physics and Technology, USTC.
Using an Oscilloscope Learning Objectives Understand the basic operation of a Cathode Ray Tube Understand what an oscilloscope is displaying Be able to.
4.5 ELECTRON BEAMS ELECTRONS AND ELECTRONICS. Electron Beams Given enough energy, electrons can escape from a conductor and move through a vacuum space.Beams.
Making Equations (2) Algebra 5 x + 7 Area = 53cm 2 The area of a rectangle. In each of the examples below, the area of the rectangle is given. Make an.
19 September 2006SuperNEMO tracker, Manchester status The SuperNEMO Tracker Manchester status Steve Snow Ray Thompson Stefan Soldner-Rembold Irina Nasteva.
Noise and Cosmics in the DHCAL José Repond Argonne National Laboratory CALICE Collaboration Meeting University Hassan II Casablanca, Morocco September.
Saverio MINUTOLIElectronics WG - 09 June AFEC cross-talk Plots illustrating Cross-talk effect AFEC pcb investigation.
A.Ochi*, Y.Homma, T.Dohmae, H.Kanoh, T.Keika, S.Kobayashi, Y.Kojima, S.Matsuda, K.Moriya, A.Tanabe, K.Yoshida Kobe University PSD8 Glasgow1st September.
PHENIX Safety Review Overview of the PHENIX Hadron Blind Detector Craig Woody BNL September 15, 2005.
Test on installed RPCs with the gas mixture. Preliminary results. Alessandro Paoloni on behalf of the OPERA RPC Group (Bologna, LNF, LNGS, Napoli, Padova,
The fault occurred at the level of 400V-500V. Investigation of the fault to ground at the RCS.A34B2 circuit Between 3 and 12 September, 2014 we carried.
Study of gas mixture containing SF6 for the OPERA RPCs A.Paoloni, A. Mengucci (LNF)
Measuring the Position resolution of a COMPASS Drift Chamber Prototype Rojae Wright, Mathias Perdekamp, Ihnjea Choi, Alabama A&M university, University.
Tracking Session, Groningen, August 30th, News from Krakow on the Forward Tracker J. Smyrski Institute of Physics UJ Model of the tracking stations.
A. Calcaterra, R. de Sangro, G. Felici, G. Finocchiaro, P. Patteri, M. Piccolo INFN LNF XIV SuperB General Meeting DCH-I parallel session LNF, 27 September.
Fun with Pyramids By D. Fisher
A. Calcaterra, R. de Sangro, G. Felici, G. Finocchiaro, P. Patteri, M. Piccolo INFN LNF XIII SuperB General Meeting DCH-I parallel session Elba, 30 May.
Electrostatic FEA on Field Cage Profile Configurations Bo Yu.
Update of Prototype AT-TPC May 6, 2010 Weekly meeting Daisuke Suzuki, NSCL.
The LNF test setup Status as of
SPACE.
European DHCAL Meeting 13/06/08
MDT second coordinate readout: status and perspectives
News on second coordinate readout
BaBar IFR Upgrade Mark Convery SLAC 7 Jun 06.
Overview of T1 detector T1 is composed by 2 arms
Gabriel Palacios 03/17/17 Danny’s Shed Gabriel Palacios 03/17/17.
Perturbation of Focusing Field Profile due to HV Support Tube
Efficiency Study of Prototype Scintillator for INGRID
SksMinus status 14 HB meeting 2008/10/16 白鳥昂太郎.
350kV and 500kV Yan 9/8.
Single rate plateau curve with different gas mixture
Space The element of art that refers to the emptiness or area around, between, above, below, or within objects. It defines shape and form.
Find the perimeter and area of each shape.
Presentation transcript:

Large Cell Scope Pictures HV Gnd 1nF Large Cell Tube Anode signal Cathode signal scope S1 S2 S1 S2 The following scope pictures were all taken with the setup listed below: Gas: ZEUS (89/8/3 CO2/IsoB/Ar) HV: 5.3kV (this is supply reading, HV probe reads 5.215kV) Cell: closest to edge of tube (near gas fitting, see picture below) Cosmic ray coincidence between a Si counters above and below tube, near middle of tube No preamps, scope terminated with 50 ohms for anode and cathode Cathode made out of copper tape 4cm wide running length of tube copper side faces tube (see picture below) Ground plane above cathode and below tube (see picture below) Channel 1= Cathode, Channel 2= Anode gg g=gas fitting +=HV 0=ground

Scope pictures Channel 1= Cathode, Channel 2= Anode

Scope pictures ??? Channel 1= Cathode, Channel 2= Anode

Scope pictures Channel 1= Cathode, Channel 2= Anode