Metrology and Gauging Instructed by: Dr. Sajid Zaidi

Slides:



Advertisements
Similar presentations
Industrial Instrumentation
Advertisements

It is very difficult to measure the small change in volume of the mercury. If the mercury had the shape of a sphere, the change in diameter would be very.
Instructor: Lichuan Gui
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
Characteristics of Instruments P M V Subbarao Professor Mechanical Engineering Department A Step Towards Design of Instruments….
STATIC CHARACTERISTICS OF MEASURING INSTRUNMENTS
VOLTMETER LOADING EFFECTS
1 Fourth Lecture Static Characteristics of Measurement Systems (continued) Instrumentation and Product Testing.
1 Third Lecture Measurement System and Its Static Characteristics Instrumentation and Product Testing.
Part 1: Basic Principle of Measurements
II–3 DC Circuits II Applications Main Topics Example of Loop Currents Method Real Power Sources. Building DC Voltmeters and.
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
SENSORS AND TRANSDUCERS
Classification of Instruments :
Types of Measurement Direct Measurement : In direct measurement, the meaning of the measurement and the purpose of the processing operation are identical.
Islamic University of Gaza Industrial Engineering Department EIND3102: Measurements Lab.
1 Measurement and Instrumentation. 2 CODE: MET General Introduction to Measurement and Instrumentation Kamoleka, Masoud MSc(Renewable Energy), UDSM.
Instrumentation and Measurements
Sensors -measure and report the state of some variable which characterizes the process uses a physical/chemical propertyconverts it into useful signal.
V. Rouillard  Introduction to measurement and statistical analysis ASSESSING EXPERIMENTAL DATA : ERRORS Remember: no measurement is perfect – errors.
Unit 1 Concept of Measurement
INTRODUCTION TO MEASUREMENT
1 Passive components and circuits - CCP Lecture 4.
Performance characteristics for measurement and instrumentation system
Part 1: Basic Principle of Measurements
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Metrology & Statistical Quality Control 5 th Term Batch /1/2012lec# 5 & 61.
Instrumentation and Measurements Class 3 Instrument Performance Characteristics.
3. Sensor characteristics Static sensor characteristics
Lecture 3 Mechanical Measurement and Instrumentation MECN 4600 Department of Mechanical Engineering Inter American University of Puerto Rico Bayamon Campus.
Lecture I Sensors.
Statistical Process Control04/03/961 What is Variation? Less Variation = Higher Quality.
INSTRUMENTATION Introduction to Instrumentation Syarifah Norfaezah
Definition Metrology is the name given to the science of pure measurement. Engineering Metrology is restricted to measurements of length & angle Measurement.
Module 1: Measurements & Error Analysis Measurement usually takes one of the following forms especially in industries: Physical dimension of an object.
Aerospace Engineering Laboratory I  Basics for Physical Quantities and Measurement  Physical Quantity  Measured Quantity VS Derived Quantity.
CfE Advanced Higher Physics
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
Definition of a sensor Def. 1. (Oxford dictionary)
Lecture 7: Measurement Systems.
1 Chapter 01 Measurement And Error. 2 Summary Instrument – a device or mechanism used to determine the present value of a quantity Measurement – a process.
Instrument Characteristics  Scientific Instrument: l A device for making a measurement.  Measurement: l An action intended to assign a number as the.
EKT 314/4 WEEK 1 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
G UJARAT P OWER E NGINEERING A ND R ESEARCH I NSTITUTE, M EWAD PHILOSOPHY OF MEASUREMENT Created By: 1. Urvish Mehta ( ) 2. Viraj Shah ( )
2. Sensor characteristics Static sensor characteristics
Instrumentation & Measurement
ELECTRONIC INSTRUMENTATIONS
MECH 373 Instrumentation and Measurement
ENGINEERING MEASUREMENTS
Measurements & Instrumentation – Module 3
MMM Lecture 2.
M&M/ UNIT- 1 Error types,control,standards/ K.Ragunath, AP/Mech
(7) Measurement Systems.
ELECTRICAL MEASURMENT AND INSTRUMENTS
Characteristics of measurement systems
Electronic Control Systems Week 4 – Signaling and Calibration
Chapter 2: Performance Characteristics of Instruments
BASICS OF MEASUREMENT AND INSTRUMENTATION
Introduction to Instrumentation Engineering
Mechanical Measurements and Metrology
Instrumentation & Measurement (ME342)
Lesson 10: Sensor and Transducer Electrical Characteristics
Measurements Measurements and errors :
Measurement errors and uncertainties
Measurements & Error Analysis
Measurements and Instrumentation
Basic Steps in Development of Instruments
EC 217 MEASUREMENTS AND INSTRUMENTATION
Presentation transcript:

Metrology and Gauging Instructed by: Dr. Sajid Zaidi PhD in Advanced Mechanics, UTC, France MS in Advanced Mechanics, UTC, France B.Sc. in Mechanical Engineering, UET, Lahore B.TECH Mechanical Technology IQRA COLLEGE OF TECHNOLOGY (ICT) INTERNATIONAL ISLAMIC UNIVERSITY, ISLAMABAD

Definition of Metrology Comes from Greek “metron” (measure) and –logy. It refers to science of measurement, including all theoretical and practical aspects of measurement. Measurement It is the procedure of comparing an unknown quantity to a known standard by means of consistent system of units. Provides a numerical value of quantity within certain limits of accuracy and precision. Inspection It is the procedure in which part characteristics (e.g. dimension) are examined whether they conform to design specification. Many inspection procedures rely on measurement techniques while others use gauging methods (simply determine whether the part passes or fails inspection). Metrology and Gauging Introduction

Definition of Quality Quality Need of Inspection It refers to a product’s fitness for use. It is the totality of features that bear on a product’s ability to satisfy a given need. Need of Inspection To ensure that part and components are confirmed to required standards. To meet the need of Interchangeability of parts. To maintain good customer relationship by ensuring that No faulty product reaches the customer. The result of inspection are forwarded to the manufacturing department, thus helps in improving the quality. It helps to purchase good quality raw material, tool and equipment. It led to development of precision measuring instruments. Metrology and Gauging Introduction

Measure of Quality Metrology and Gauging Introduction

Measure of Quality – What to Inspect Metrology and Gauging Introduction

Measure of Quality – When to Inspect Metrology and Gauging Introduction

Measure of Quality – How to Inspect Metrology and Gauging Introduction

Characteristics of Measurement Systems The performance characteristics of a measuring system may be broadly divided into two groups, namely ‘static’ and ‘dynamic’ characteristics. Static characteristics are the values given when steady- state conditions occur, i.e. the values given when the system has settled down after having received some input. Static characteristics also refer to the measurement of quantities which are constant or vary slowly with time. For example, the resistance of a resistor etc. Dynamic characteristics refer to the behavior between the time that the input value changes and the time that the value given by the system settles down to the steady state value. Metrology and Gauging Introduction

Static Characteristics Accuracy Accuracy determines the closeness of an instrument reading to the true value of the physical variable. Accuracy is often expressed as a percentage of the full range output or full-scale deflection (f.s.d). For example, a system might have an accuracy of ±1% of f.s.d. If the full-scale deflection is 10 A then the accuracy is ±0.1 A. This means that when the instrument is reading 1.0 A, the possible error is 10% of this value. The accuracy is a summation of all the possible errors that are likely to occur. Metrology and Gauging Introduction

Static Characteristics Precision The term precision is used to describe the degree of freedom of a measurement system from random errors. Precision is related to the repeatability of the instrument reading. Thus, a highly precise measuring instrument will give only a small spread of readings if repeated readings are taken of the same quantity. A low precision system will give a large spread of readings. For example, consider the following two sets of readings obtained for repeated measurements of the same quantity by two different instruments: Metrology and Gauging Introduction

Static Characteristics Precision 20.1 mm, 20.2 mm, 20.1 mm, 20.0 mm, 20.1 mm, 20.1 mm 19.9 mm, 20.3 mm, 20.0 mm, 20.5 mm, 20.2 mm, 19.8 mm The results of the measurement give values scattered about some value. The first set of results shows a smaller spread of readings than the second and indicates a higher degree of precision for the instrument used for the first set. Precision is often, though incorrectly, confused with accuracy. High precision does not imply anything about measurement accuracy. A high precision instrument may have a low accuracy. Low accuracy measurements from a high precision instrument are normally caused by a bias in the measurements, which is removable by recalibration. Metrology and Gauging Introduction

Static Characteristics Precision Vs Accuracy Metrology and Gauging Introduction

Static Characteristics Precision Vs Accuracy Measuring a fixed target position from a satellite Metrology and Gauging Introduction Satellite Apollo 13: Low precision low accuracy Satellite PolyU 18: High precision low accuracy Satellite CYT 118: High precision, High accuracy

Static Characteristics Repeatability and Reproducibility Repeatability describes the closeness of output readings when the same input is applied repetitively over a short period of time, with the same measurement conditions, same instrument and observer, same location and same conditions of use maintained throughout. Reproducibility describes the closeness of output readings for the same input when there are changes in the method of measurement, observer, measuring instrument, location, conditions of use and time of measurement. Both terms thus describe the spread of output readings for the same input. This spread is referred to as repeatability if the measurement conditions are constant and as reproducibility if the measurement conditions vary. Metrology and Gauging Introduction

Static Characteristics Range The range or span of an instrument defines the minimum and maximum values of a quantity that the instrument is designed to measure. For example, a thermometer might be quoted as having a range of -200 to +800°C. Metrology and Gauging Introduction Threshold If the instrument input is very gradually increased from zero there will be a minimum value required to give a detectable output change. This minimum value defines the threshold of the instrument. input Output Threshold

Static Characteristics Linearity It is normally desirable that the output reading of an instrument is linearly proportional to the quantity being measured. The X’s marked on the Figure show a plot of the typical output readings of an instrument when a sequence of input quantities are applied to it. Normal procedure is to draw a good fit straight line through the X’s, as shown in Figure. The non-linearity is then defined as the maximum deviation of any of the output readings marked X from this straight line. It is usually expressed as a percentage of full-scale reading. Metrology and Gauging Introduction

Static Characteristics Linearity Metrology and Gauging Introduction

Static Characteristics Sensitivity The sensitivity indicates how much the output of an instrument system changes when the quantity being measured changes by a given amount, i.e. the ratio of ouput to input. For example, a thermocouple might have a sensitivity of 20 μV/ºC and so give an output of 20 μV for each 1ºC change in temperature. If we take a series of readings of the output of an instrument for a number of different inputs and plot a graph of output against input, the sensitivity is the slope of the graph. Metrology and Gauging Introduction

Static Characteristics Sensitivity Metrology and Gauging Introduction Output, Vo (V) Input, Fi (kN) Slope = Output / Input Load Cell Force, F Output, Vo By plotting a graph and finding the best straight line, you can obtain the slope m from the expression y = mx + c

Static Characteristics Error The term error is used for the difference between the result of the measurement and the true value of the quantity being measured, i.e. error = measured value - true value Thus if the measured value is 10.1 when the true value is 10.0, the error is +0.10 If the measured value is 9.9 when the true value is 10.0, the error is -0.10 Errors can arise in a number of ways and the following describes some of the errors that are encountered in specifications of instrumentation systems. Metrology and Gauging Introduction

Static Characteristics Hysteresis Error The term hysteresis error is used for the difference in outputs given from the same value of quantity being measured according to whether that value has been reached by a continuously increasing change or a continuously decreasing change. Metrology and Gauging Introduction A different value may be obtained from a thermometer used to measure the same temperature of a liquid if it is reached by the liquid warming up to the measured temperature or it is reached by the liquid cooling down to the measured temperature.

Static Characteristics Non-linearity Error The term non-linearity error is used for the error that occurs as a result of assuming a linear relationship between the input and output over the working range, i.e. a graph of output plotted against input is assumed to give a straight line. Linearity error is usually expressed as a percentage error of full range or full scale output. Metrology and Gauging Introduction

Static Characteristics Insertion Error When a cold thermometer is put in to a hot liquid to measure its temperature, the presence of the cold thermometer in the hot liquid changes the temperature of the liquid. The liquid cools and so the thermometer ends up measuring a lower temperature than that which existed before the thermometer was introduced. This effect is called loading and the consequence is the insertion error. Loading is a problem that is often encountered when measurements are being made. For example, when an ammeter is inserted into a circuit to make a measurement of the circuit current, it changes the resistance of the circuit and so changes the current being measured. Metrology and Gauging Introduction

Static Characteristics Application A commercial pressure measurement system is quoted in the manufacturer's specification as having: Range 0 to 10 kPa Supply Voltage ±15 V dc Linearity error ±0.5% FS Hysteresis error ±0.15% FS Sensitivity 5 V dc for full range Thermal sensitivity ±0.02%/ºC Thermal zero drift 0.02%/ºC FS Temperature range 0 to 50ºC Metrology and Gauging Introduction

Dynamic Characteristics The dynamic characteristics refer to the behavior between the time that the input value changes and the time that the value given by the system settles down to the steady state value. Metrology and Gauging Introduction For example, the figure shows how the reading of an ammeter might change when the current is switched on. The meter pointer oscillates before settling down to give the steady-state reading.

Dynamic Characteristics Response Time This is the time which elapses after the input to a system is abruptly increased from zero to a constant value up to the point at which the system gives an output corresponding to some specified percentage, e.g. 95%, of the value of the input. Rise Time This is the time taken for the output to rise to some specified percentage of the steady-state output. Often the rise time refers to the time taken for the output to rise from 10% of the steady-state value to 90 or 95% of the steady-state value. Metrology and Gauging Introduction