P11011: M OTION -T RACKING S YSTEM F INAL D ESIGN R EVIEW Brittany Bochette Lindsey Clark Mike Ostertag Maya Ramaswamy Andrei Stihi.

Slides:



Advertisements
Similar presentations
Feedback Control Dynamically or actively command, direct, or regulate themselves or other systems.
Advertisements

Android Enabled Camera Positioning system Design Team 3 Chris Sigler Yan Sidronio Ryan Popa Jeremy Iamurri Austin Fletcher Facilitator: Dr. Oweiss Sponsor:
BARTOSZEK ENGINEERING 1 The Design of the Booster Collimators Larry Bartoszek BARTOSZEK ENGINEERING 3/10/03.
Outline quad-copter Abstract Quad-Copter Movement Hand movement
Position Sensing Glove Barbara Tuday Nathan Schreppler Lauren McIlwain Michael Nolan Team 6:
University of Bridgeport
© Copyright 2011 MicroStrain Inc. High Performance Miniature Inertial Measurement Systems MicroStrain Inc Mike Robinson
The Bioloid Robot Project Presenters: Michael Gouzenfeld Alexey Serafimov Supervisor: Ido Cohen Winter Department of Electrical Engineering.
Airplane Flight: X-Plane in the Classroom Control Pitch - nose moves up and down.
Attitude Determination and Control
P11211: L AND V EHICLE FOR E DUCATION : C HASSIS, M OTOR, P OWER Ryan Sutton: Project Manager / Mechanical Engineer Jonathan Fabian: Interface Manager.
P09321 A UTOMATED M EDICINE D ISPENSER Justin Zagorski (IE) – Project Lead Rebecca Jaiven (EE) – Lead Engineer Michael Boquard (CE) Matthew Jones (ME)
Final Project Overview GROUP MEMBERS: Irma Bocova Rob Bowman Phetphouvanh “Awt” Phommahaxay Kyle Pilote Jeff Rebmann Chris Rowles Faculty Guide: Dr. Elizabeth.
MSD-I Project Review Modular Motion Tracking Sensors 1.
EDGE™ MAV Control System - P Management Review (MSD I) Erik Bellandi – Project Manager Ben Wager – Lead Engineer Garrett Argenna – Mechanical Engineering.
Motion Tracking System Research and Testing Rochester Institute of Technology DAVID J. MONAHAN (ME) JIM K. STERN (ME) JAHANAVI S. GAUTHAMAN (EE) BRIAN.
Michelle Bard (ME) Alexander Ship (ME) David Monahan (ME) Kristin Gagliardi (ME) October 12, 2009.
Introduction to Robotics Lecture II Alfred Bruckstein Yaniv Altshuler.
Theoretical Foundations of Multimedia Chapter 3 Virtual Reality Devices Non interactive Slow image update rate Simple image Nonengaging content and presentation.
Collaboration Meeting at UCI, April 7-9, 2005 ANITA Navigation and Orientation Kurt Liewer.
MSD-II Project Review Modular Motion Tracking Sensors 1.
Screw Rotation and Other Rotational Forms
Motion Tracking System Research and Testing Rochester Institute of Technology DAVID J. MONAHAN (ME) JAMES K. STERN (ME) JAHANAVI S. GAUTHAMAN (EE) ASSIS.
Crossbow Products Presented by: Stephen Justice. Topics Brief view of gyros Brief view of gyros A look at MEMS A look at MEMS The two types of sensors.
Utilizing your notes and past knowledge answer the following questions: 1) What part of the aircraft is located on the outer portion of the trailing edge.
More details and examples on robot arms and kinematics
CS 450: COMPUTER GRAPHICS 3D TRANSFORMATIONS SPRING 2015 DR. MICHAEL J. REALE.
Airborne Gravity Processing 101 Sandra Preaux
P09321 A UTOMATED M EDICINE D ISPENSER Justin Zagorski (IE) – Project Lead Rebecca Jaiven (EE) – Lead Engineer Michael Boquard (CE) Matthew Jones (ME)
Jonathan Wong Chong 14.8V Polymer Li-Ion Batteries o Only powering thrusters 19v 4Ah Li-Ion External Laptop Battery o Powers main.
Introduction Designing controllers for walking robots presents many challenges. In order for walking robotics to reach this stage, perhaps a new approach.
Team Dominate(d?) The Machine.
P11011: M OTION -T RACKING S YSTEM D ETAILED D ESIGN R EVIEW Brittany Bochette Lindsey Clark Mike Ostertag Maya Ramaswamy Andrei Stihi.
Chapter 2 Robot Kinematics: Position Analysis
Software Overview The software that controls the Place n’ Paste is designed to be robust and error proof. With minimal intervention from the user, the.
Muscle Volume Analysis 3D reconstruction allows for accurate volume calculation Provides methods for monitoring disease progression Measure muscle atrophy.
Sérgio Ronaldo Barros dos Santos (ITA-Brazil)
IMPROVE THE INNOVATION Today: High Performance Inertial Measurement Systems LI.COM.
Inertial Navigation System Overview – Mechanization Equation
INEMO™ Demonstration Kit DOF (Degrees of Freedom) platform  The STEVAL-MKI062V2 combines accelerometers, gyroscopes and magnetometers with pressure.
ZMP-BASED LOCOMOTION Robotics Course Lesson 22.
Touchdevelop api api gyroscope measure device rotation rate Disclaimer: This document is provided “as-is”. Information and views expressed in this document,
Source: Computer Vision and Pattern Recognition Workshops (CVPRW), 2010 IEEE Computer Society Conference on Author: Paucher, R.; Turk, M.; Adviser: Chia-Nian.
P12022: LVAD P OWER T RANSMISSION T EST R IG Erin McNally Pedro Baez Paul Parthemore Kris Stichter.
ClearVision Final Presentation Senior Design 1. Team Members Travis Ann Nylin Electrical Engineer System Testing Schematic Data-Logging and Retrieval.
Ship Computer Aided Design Displacement and Weight.
Current Works Corrected unit conversions in code Found an error in calculating offset (to zero sensors) – Fixed error, but still not accurately integrating.
P08311: FPGA Based multi-purpose driver / data acquisition system Sponsor: Dr. Marcin Lukowiak Team MemberDisciplineRole Andrew FitzgeraldCEProject Manager/FPGA.
Setting up correctly Different types and their use
Magnetically Levitated Propeller Bernie Garcia (ME, Team Leader), Joe Bernardini (ME, Scribe), Elijah Sensenig (EE, System Integrator), Zachary Louison.
Magnetically Levitated Propeller Bernie Garcia (Me, Team Leader), Joe Bernardini (ME, Scribe), Elijah Sensenig (EE, System Integrator), Zachory Louison.
ClearVision Mid-Semester Presentation Senior Design 1.
TigerBot IV Rochester Institute of Technology. Group Members Mike Lew (ISE) Dan Wiatroski (ME) Tom Whitmore (ME) Geoff Herman (ME) Sean Lillis (CE) Brian.
AHRS calibration and performance study V. Kulikovskiy.
MSD-II P ROJECT R EVIEW Modular Motion Tracking Sensors 1.
Joseph Ferrara Team Lead (ME) Joseph ChurchDesign Engineer (ME) Joshua Van Hook LabView Engineer (EE) Jamie Jackson Electronics (EE) Joelle Kirsch Project.
Comparison of Sensor Analysis for Swimming in Different Positions
P15051: Robotic Eye System Design Review
P08002-Automated Parallel Bars
Inertial Measurement Unit (IMU) Basics
SQUIGGLE NANOMANIPULATOR
Inertial Measurement Units
Modular Motion Tracking Device
Modular Motion Tracking Sensors
Final Project Review P09006 – Upper Extremity Exerciser
Paige Thielen, ME535 Spring 2018
Modular Motion Tracking Device
Final Status Update P09006 – Upper Extremity Exerciser
Human Gait Analysis using IMU Sensors
Presentation transcript:

P11011: M OTION -T RACKING S YSTEM F INAL D ESIGN R EVIEW Brittany Bochette Lindsey Clark Mike Ostertag Maya Ramaswamy Andrei Stihi

P ROJECT B ACKGROUND Motion-tracking system that measures knee flexion and head-tilt Continuation of past senior design groups P10010 Sensors P10011 Attachment Methods Customers are Nazareth Physical Therapy Clinic and Rochester General Hospital

K EY C USTOMER N EEDS Measurement +/- 80 degrees of tilt and +/- 100 degrees of rotation Accuracy 5-10 degrees error Reproducibility 5-10 degrees Speed of Attachment and Removal 2 minutes, 5 seconds

C ONCEPT O VERVIEW FTDI 3.3V Breakout Board Razor 9DOF IMU USB Brass screws Attachment Snaps Foam stabilizer Protective enclosure

S YSTEM A RCHITECTURE

Base Unit S YSTEM A RCHITECTURE Knee Flexion Head-Tilt Options Quit USB

A TTACHMENT M ETHODS Head attachment and enclosure Leg attachments with enclosures

E NCLOSURES Internals: Brass screws and nuts were used, along with rubber washers for interference free operation Foam padding was used on the backside to stabilize it when used with various attachment methods through the use of snaps

D ETERMINING K NEE F LEXION Sensor is placed on the side of the leg with gravity being felt in the X and Y components of the accelerometer The orientation of the sensor relative to gravity was calculated with Equation 1. The amount of flexion is the difference between the two angles as seen in Equation 2. Eq. 1 Eq. 2 X Y Z AgAgAgAg

D ETERMINING H EAD O RIENTATION Head has complex motion due to three-axes of rotation Breaking down motion to three individual axes (seen above) simplifies the process of determining orientation AnterocollisRetrocollisLaterocollisTorticollis

D ETERMINING H EAD O RIENTATION Antero/retrocollis (pitch) and laterocollis (roll) were determined using a three-axis accelerometer Angles were determined by comparing the components of acceleration caused by gravity (A g ) Eq. 3 Eq. 4 X Y Z AgAgAgAg

D ETERMINING H EAD O RIENTATION Torticollis (yaw) was determined using the three- axis magnetometer and the following procedure: 1. The magnetometer readings were corrected for tilt based upon the pitch and roll found previously. 2. A current magnetic heading was found with the following equation: 3. The difference between the initial and current magnetic heading is the amount that the head has rotated. Eq. 5 Eq. 6

T ESTING 30˚ rotation in the pitch, roll, and yaw directions Changes in degree during four knee flexion cycles

R ESULTS SpecificationExpectedActual Measurement Tilt: +/- 80˚ Rotation: +/- 100˚ Tilt: +/- 90˚ Rotation: +/- 180˚ Accuracy5-10˚ Roll: within 5˚ Pitch: within 10˚ Yaw: within 8˚ Precision5-10˚ Roll: 2˚ Pitch: 6˚ Yaw: 2˚ Speed of attachment/removal 2 minutes/5 seconds28 seconds/3 seconds

C URRENT S TATE OF D ESIGN Design is functional Meets all engineering specifications except Measurement of shift –discussed this with the customer and it is an option for future designs Budget requirements - $1000 allowed, $ spent After changing scope, we used the more expensive Razor IMU for both systems This caused a slight budget overrun for the knee device On schedule with exception of rescheduled D3 meetings ExpectedActual Dr. Mowder$300$315 Dr. Barbanounlimited$315

R ISK A SSESSMENT Contacting our customers and scheduling meetings with them proved to be one of the most relevant risks. The device not meeting customer needs was also something that was a possible risk up until week nine. Not being able to communicate with the base unit was another risk we had to address

P ROJECT E VALUATION Project was originally scoped too large The intent of the project became clearer after a re-scoping at the end of MSD I Base unit and sensor sub-systems should be one group With a similar project, a prototype should be the first step rather than a fully functioning system

R ECOMMENDATIONS Being able to measure shift of the head would be something desired by Dr. Barbano in the future. Dr. Barbano also voiced a need to have something on the device that helped him to level the device on the patient so that human error was reduced or even eliminated. Dr. Mowder suggested using Dysom or some other rubber-like material to prevent the strap on the calf from slipping