Experiment 12 Non-Inverting Amplifier. Experimental Procedure Clarification in Step 3 (Modeling) – To perform the DC Sweep in the sinusoidal voltage source.

Slides:



Advertisements
Similar presentations
1.6 Op-Amp Basics High input impedance Low output impedance Made using difference amplifiers having 2 inputs and at least 1 output 1 Note: Terminals for.
Advertisements

Operational Amplifier
Operational Amplifiers
Operational Amplifiers 1. Copyright  2004 by Oxford University Press, Inc. Microelectronic Circuits - Fifth Edition Sedra/Smith2 Figure 2.1 Circuit symbol.
Chapter 7 Operational-Amplifier and its Applications
Experiment 17 A Differentiator Circuit
ENTC 3320 Absolute Value.
Design a Logic Probe Experiment 20. Design Specifications Design a logic probe as shown in the block diagram of Figure 1 of Experiment 20 with a signal.
Experiment 11: An Inverting Amplifier
In PSpice. DC Sweep in PSpice A simulation that results in a plot of specified voltages and/or currents in the circuit as a function of a particular variable.
Non-Ideal Characteristics Input impedance Output impedance Frequency response Slew rate Saturation Bias current Offset voltage.
Introduction to the OP AMP
ECE 201 Circuit Theory I1 Introduction to the Operational Amplifier μA 741 OP AMP.
* Operational Amplifiers * Op-Amp Circuits * Op-Amp Analysis
Lecture 91 Loop Analysis (3.2) Circuits with Op-Amps (3.3) Prof. Phillips February 19, 2003.
Op Amps Lecture 30.
Operational Amplifiers
Pulse Width Modulation (PWM) LED Dimmer Circuit
Week 9: Design a Night Light
Pulse Width Modulation (PWM) LED Dimmer Circuit
Operational Amplifiers
Experiment 11: Non-Inverting Amplifier With Modifications that Require the Use of the Velleman Oscilloscope.
An Inverting Amplifier. Op Amp Equivalent Circuit The differential voltage v d = v 2 – v 1 A is the open-loop voltage gain v2v2 v1v1 An op amp can be.
Introduction to Op Amp Circuits ELEC 121. April 2004ELEC 121 Op Amps2 Basic Op-Amp The op-amp is a differential amplifier with a very high open loop gain.
Objective of Lecture Apply the ‘almost ideal’ op amp model in the following circuits: Inverting Amplifier Noninverting Amplifier Voltage Follower Summing.
Week 7: Design a Night Light New Experiment It is not in the lab manual.
A Differentiator Circuit.  All of the diagrams use a uA741 op amp. ◦ You are to construct your circuits using an LM 356 op amp.  There is a statement.
Experiment 17 A Differentiator Circuit
Microelectronic Circuits, Sixth Edition Sedra/Smith Copyright © 2010 by Oxford University Press, Inc. C H A P T E R 02 Operational Amplifiers.
What is an Op Amp? Ideal Op Amps Applications Examples Lecture 9. Op Amps I 1.
1 Fundamentals of Microelectronics  CH1 Why Microelectronics?  CH2 Basic Physics of Semiconductors  CH3 Diode Circuits  CH4 Physics of Bipolar Transistors.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
EE 1270 Introduction to Electric Circuits Suketu Naik 0 EE 1270: Introduction to Electric Circuits Lecture 13: Operational Amplifiers Part 1 Chapter 5.
Chapter 30 Operational Amplifiers. 2 Introduction Characteristics –High input impedance –Low output impedance –High open-loop gain –Two inputs –One output.
Study Guide Exam 2. Closed book/Closed notes Bring a calculator.
1 1.6 Op-Amp Basics Basic Op-Amp Op-amp equivalent circuit Practical (R i = high, R o = small)Ideal (R i =∞, R o = 0)
Operational Amplifiers Op Amps – a useful building block K. El-Ayat 11.
Design a Logic Probe Experiment 20.
E E 2315 Lecture 08 - Introduction to Operational Amplifiers.
Experiment 10: Inverting Amplifier With Modifications that Require the Use of the Velleman Oscilloscope.
Exporting Data from Scope to Excel. Save DSO Data After you have made measurements using the Velleman scope, you can save the data as a.txt file using.
Wheatstone Bridge. Schematic of a Wheatstone Bridge V BA = 0V and I R3 = I R4 if R 1 = R 2 and R 3 = R 4. Typically, the resistors are selected such that.
OP-AMPs Op Amp is short for operational amplifier. An operational amplifier is modeled as a voltage controlled voltage source. An operational amplifier.
Week 4: Experiment 24 Using Nodal or Mesh Analysis to Solve AC Circuits with an addition of Equivalent Impedance.
1 Chapter 8 Operational Amplifier as A Black Box  8.1 General Considerations  8.2 Op-Amp-Based Circuits  8.3 Nonlinear Functions  8.4 Op-Amp Nonidealities.
Operational Amplifiers 1. Copyright  2004 by Oxford University Press, Inc. Microelectronic Circuits - Fifth Edition Sedra/Smith2 Figure 2.1 Circuit symbol.
Transient Response. Transient Analysis Plot of the voltages or currents as a function of time. – Output plot mimics the oscilloscope display. If simulating.
Enrollment no. : Darshan Institute of Engineering & Technology - Rajkot Department of Electrical Engineering ANALOG ELECTRONICS ( )
Figure 5.1 The eight-lead DIP package (top view).
1.6 Op-Amp Basics Basic Op-Amp Practical (Ri = high , Ro = small)
Inverting and Non-inverting Op-Amp
ECE 1270: Introduction to Electric Circuits
Analogue Electronic 2 EMT 212
OP-AMPS: basics & Inverting-amplifier
The Ideal Op Amp Inverting and non-Inverting configurations
Introduction to the OP AMP
Operational Amplifiers
Ch. 5 – Operational Amplifiers
Lesson 3: op amp fundamentals and open loop applications
Introduction to the OP AMP
The Ideal Op Amp Inverting and non-Inverting configurations
Operational Amplifier (Op-Amp)-μA741
Chapter 4 – Operational Amplifiers – Part 2
Ch. 5 – Operational Amplifiers
Week 4: Experiment 24 Using Nodal or Mesh Analysis to Solve AC Circuits with an addition of Equivalent Impedance.
Ch. 5 – Operational Amplifiers
Ch. 5 – Operational Amplifiers
BLM Circuit Theory Prof. Dr. Nizamettin AYDIN
OPERATIONAL AMPLIFIERS
Presentation transcript:

Experiment 12 Non-Inverting Amplifier

Experimental Procedure Clarification in Step 3 (Modeling) – To perform the DC Sweep in the sinusoidal voltage source in the circuit must be replaced with a dc voltage source, Vdc. Typo in Step 4 (Modeling) – Gain of the VCVS should be set to 100,000. – The gain of the amplifier circuit should be 4, set by the values for R 1 and R f.

Op Amp Equivalent Circuit v d = v 2 – v 1 A is the open-loop voltage gain v2v2 v1v1

Typical Op Amp Parameters ParameterVariableTypical RangesIdeal Values Open-Loop Voltage Gain A10 5 to 10 8 ∞ Input Resistance Ri 10 5 to  ∞ ∞  Output Resistance Ro 10 to 100  0 0  Supply VoltageVcc/V + -Vcc/V - 5 to 30 V -30V to 0V N/A

Voltage Transfer Characteristic Positive Saturation Voltage Negative Saturation Voltage

PSpice Circuit for Non-Inverting Amplifier

Voltage Controlled Voltage Source An ideal op amp can be modeled as a voltage controlled voltage source. – The difference in voltage between the positive and negative inputs of the op amp (v d = v 2 – v 1 ) is the reference voltage for the VCVS. – The output voltage of the VCVS should be the open-loop gain times v d. Ideally, A is infinite.

Circuit with Voltage Controlled Voltage Source (Part E): Schematics Note: Resistor values shown do not produce a gain of 4.

Set Open Loop Gain Double click on symbol and set GAIN to at least 100,000 – Typical open loop gain of an op amp is V/V

Circuit with Voltage Controlled Voltage Source (Part E): Capture Note: Resistor values shown do not produce a gain of 4.

Open Loop Gain Double click on symbol for Part E. Set GAIN in Property Editor pop-up window to at least 100,000.

Circuit to be constructed

Cables The connections to the Velleman scope are BNC (Bayonet Neill-Concelman) connectors. – You will need to use 3 BNC cables with either the alligator clips or the IC clips to make your connections between the scope and your circuit.

Input Voltage Source Use the sine wave generator on the Velleman scope. – Set the amplitude of the sine wave to 5V Note that the amplitude on the Velleman scope is actually peak-to-peak so you should actually make this 3V. – Set the frequency of the sine wave to 1000Hz. – Connect BNC cable to function generator (bottom BNC connection). Clip red probe to end of R2. Clip black probe (ground) to end of R1 or R3.

Voltage Measurements using Oscilloscope Channel 1: – Red probe placed between function generator and R2. – Black probe connected to same point as the black wire from the function generator. Channel 2: – Red probe placed between output of the LM 324 and the feedback resistor, Rf, or or between output of the LM 324 and R3. – Black probe connected to same point as the black wire from the function generator.

Measurements 1. Set trim pot value such that the output voltage of the op amp is equal to 2.0V when the input voltage is +1.0V. – Take a screen shot of the input and output voltage as a function of time, displaying at least 3 cycles. – Remove Rf from the circuit. Measure and record the resistance between pins 1 and 2. – Measure the output voltage at the following input voltages: 0V, +/-1V, +/-2V, +/-3V, +/- 4V, and +/-5V. – use cursors in scope program – Plot the output voltage vs. the input voltage using the X-Y plot function on the oscilloscope. – Export the data from the oscilloscope. You may use Excel to plot the DC voltage transfer characteristic. Determine – the gain of the inverting amplifier in the linear region of the voltage transfer characteristic using a least squares determination of the slope in the linear region – the output voltage at the positive and negative saturation regions. 2. Repeat set of measurements where gain is set to +3 and +4 when the input voltage is +1.0V.

Exporting Data From Oscilloscope

Scaling Required: Time To determine the time to print on the x-axis: Look at TIME STEP: for the number of points (125) that are equal to a time increment (1ms). This means that the time for each point in the column under N should be divided by 125 and then multipled by 1ms to determine the time at which each voltage data point was taken.

Scaling Required: Absolute Voltage To determine the voltage associated with each data point for Channel 1 and Channel 2: Look at the numbers next to CH1: and CH2: above the GND row. In this case, 1V is equivalent to 32. This means that that the value of the points in the columns CH1 and CH2 should be divided by 32 and then multiplied by 1V to finally obtain the voltage measured by the oscilloscope on Channels 1 and 2 as a function of time.

Measurements Measure exact values of V+ and V- powering the LM 324 op amp. – Note that there is a statement about maximum and minimum output voltages that can be obtained from the LM 324 in the datasheet. Datasheet can easily be found by entering LM324 and datasheet into Google or other internet search engine. – Find it and read the first page.