EasyPreparation with Barcode Reader
EasyPreparation with Barcode Reader :19 This tutorial describes the application “Easy preparation“ of the PrepGilsonST software, covering the following topics Configuration of the barcode reader How to configure the setup with an automatic assignment of the destination rack (wellplate) Create orders for selected source positions in racks with predefined procedures Run preparation for created orders Introduction
EasyPreparation with Barcode Reader :19 Selection of barcode reader 1a. Select the button “Configuration“. Barcode Reader
EasyPreparation with Barcode Reader :19 1b. Click in the area which is coloured green in the drawing. This is the base configuration area. Basic Configuration
EasyPreparation with Barcode Reader :19 1c. Click the check box “Barcode reader“, so that it is checked. Tip: With “Barcode reader“ checked the “Edit mode“ box within the “Create Order Files“ window is not visible. The barcode reader reads the ID and type. Manual input is not necessary. Basic Configuration
EasyPreparation with Barcode Reader :19 1d. Check the Barcode reader serial port. In this example the Gilson robot is connected to Com Port 1 and the barcode reader to Port 2. Click “ OK“. Basic Configuration
EasyPreparation with Barcode Reader :19 Select the menu „Edit settings“. In the next screen we distinguish between two cases: Case 1: Working with automatic destination assignment. Case 2: Working with manual destination assignment. Settings - Destination Selection
EasyPreparation with Barcode Reader :19 Case 2: Working with manual destination assignment: Click the box, so that it is checked. Case 1: Working with automatic destination assignment: Click the box, so that it is unchecked. Enter the matrix type. See also Tutorial 4 - Bruker Barcode Label Designer and Bruker Barcode Label Types Settings - Destination Selection Matrix TypeMatrix Description 209#8Standard Rack for 96x 2ml Vials 209B#8Standard Rack for 96x 2ml Cryo Vials 216#8Standard Rack for 96x 4ml Vials 526B#8Cooling Rack for 96x 2ml Cryo Vials 853B#8Cooling Rack for 96x 2ml Vials Tube Block for 24x 1.0mm Tubes Tube Block for 24x 1.7mm Tubes Tube Block for 24x 2.0mm Tubes Tube Block for 24x 2.5mm Tubes Tube Block for 24x 3.0mm Tubes Tube Block for 24x 4.0mm Tubes Tube Block for 24x 5.0mm Tubes Tube Block for 96x 1.7mm Tubes Tube Block for 96x 1mm Tubes Tube Block for 96x 3mm Tubes Tube Block for 96x 5mm Tubes Plate Round 96x 1ml Plate Squared 96x 2ml
EasyPreparation with Barcode Reader :19 3a. Click the green button to start automation. Initializing / Home seeking Reading barcodes Create orders without SampleTrack Verify orders Preparation Start Automation
EasyPreparation with Barcode Reader :19 3b. The program asks, if the barcodes should be read. Click “Yes“, if you are running the program with modified tray configuration. Start Automation
EasyPreparation with Barcode Reader :19 Case 1: Working with automatic destination assignment The destination checkbox is hidden and the destination is defined by program. Case 2: Working with manual destination assignment The destination must be selected. Start Automation
EasyPreparation with Barcode Reader :19 4a. Case 1: Working with automatic destination assignment: Select the source tubes with a lasso operation: Click and hold the left mouse cursor. Draw a rectangle. The marked positions will be shown as orders. Start Automation
EasyPreparation with Barcode Reader :19 Click „OK“. Click „Create Orders“. Start Automation
EasyPreparation with Barcode Reader :19 5. The orders are running. Start Automation
EasyPreparation with Barcode Reader :19 Case 2: Working with manual destination assignment: See the procedure in Tutorial 3 - EasyPreparation without Barcode Start Automation
EasyPreparation with Barcode Reader :19