Upgrade of liquid xenon gamma-ray detector in MEG experiment Daisuke Kaneko, the University of Tokyo, on behalf of the MEG collaboration MEG EXPERIMENT.

Slides:



Advertisements
Similar presentations
MEG 実験 液体キセノンカロリメータ におけるエネルギー分解能の追究 東大素粒子センター 金子大輔 他 MEG コラボレーション.
Advertisements

Multi Pixel Photon Counters (MPPC) and Scintillating Fibers (Sci-Fi)
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Striplet option of Super Belle Silicon Vertex Detector Talk at Joint Super B factory workshop, Honolulu 20 April 2005 T.Tsuboyama.
Mass test of MPPC with a prototype of MEG II liquid xenon detector
Yasuhiro NISHIMURA Hiroaki NATORI The University of Tokyo MEG collaboration Outline  → e  and MEG experiment Design of detector Calibration Performance.
MEG II 実験液体キセノンガンマ線検出器 における再構成法の開発 Development of the event reconstruction method for MEG II liquid xenon gamma-ray detector 小川真治、 他 MEG II
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
Wataru Ootani, ICEPP, Univ. of Tokyo SORMA X, May 21, 2002 Development of liquid xenon scintillation detector for new experiment to search for   e 
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Development of A Scintillation Simulation for Carleton EXO Project Rick Ueno Under supervision of Dr. Kevin Graham.
2 1/March/2015 日本物理学会大70回年次大会@早稲田大学 東大ICEPP 内山雄祐 他 MEG II collaboration.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
MEG positron spectrometer Oleg Kiselev, PSI on behalf of MEG collaboration.
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear  -ray.
Daisuke Kaneko, on behalf of the MEG(II) collaboration 26 Aug, Moscow Today and Tomorrow of the MEG experiment.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
MEG II 実験 液体キセノンガンマ線検出器に用いる 光検出器 MPPC の 実装に向けた最終試験 家城 佳 他 MEG II collaboration + 九大の方々.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
1 Satoshi Mihara for the   e  collaboration, review meeting at PSI, Jul 2002 Photon Detector Satoshi Mihara ICEPP, Univ. of Tokyo 1.Large Prototype.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Status of E14 G.Y.Lim IPNS, KEK. E14 Experiment Step-by-step approach to precise measurement of Br( K L    ) KEK-PS E391a J-PARC E14 (Step-1) J-PARC.
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
M.Teshima (MPP, U-Tokyo) M.Pimenta (LIP) T.Schweizer (MPP)
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Study of the cryogenic THGEM-GPM for the readout of scintillation light from liquid argon Xie Wenqing( 谢文庆 ), Fu Yidong( 付逸冬 ), Li Yulan( 李玉兰 ) Department.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
g beam test of the Liquid Xe calorimeter for the MEG experiment
小川真治、 他MEG 第72回年次大会 MEG II 実験液体キセノンガンマ線検出器における取得データサイズ削減手法の開発 Development of the data size reduction method for MEG II liquid.
NUV-SiPM short technology description
Cecilia Voena INFN Roma on behalf of the MEG collaboration
Liquid Xenon Detector for the MEG Experiment
大強度
New Study for SiPMs Performance in High Electric Field Environment
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
On behalf of the GECAM group
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
MEG実験アップグレードに向けたSiPMを用いた ポジトロン時間測定器の研究開発
R&D of MPPC for T2K experiment
MEG II実験 液体キセノン検出器の建設状況
Daisuke Kaneko, ICEPP, Univ. of Tokyo on behalf of MEG collaboration
MEG Summary T. Mori for MEG Collaboration February 9, 2005.
R&D of MPPC in kyoto M.taguchi.
Decay Angular Measurement in the MEG Experiment
The MPPC Study for the GLD Calorimeter Readout
New Results from the MEG Experiment
Presentation transcript:

Upgrade of liquid xenon gamma-ray detector in MEG experiment Daisuke Kaneko, the University of Tokyo, on behalf of the MEG collaboration MEG EXPERIMENT Performance of Upgraded Detector DC μ + beam COBRA magnet with gradient magnetic field stopping target liquid xenon detector drift chamber timing counter MEG is searching for the lepton flavor violating decay, μ → e + γ. μ → e + γ is suppressed in the standard model (~ ), but sizable probability (~10 -12~14 ) is predicted in many promising theories beyond the standard model. Signal is 52.8MeV γ-ray and 52.8MeV e + emitted back-to-back simultaneously. γ → Liquid Xenon Detector e + → Drift Chamber → Timing Counter In order to reject accidental background and thus to achieve high sensitivity, good resolutions are required for γ detector. Annu. Rev. Nucl. Part. Sci : W. J. Marciano, T.Mori, and J. M. Roney We set the current most stringent upper limit of branching ratio, 2.4× at 90% CL. in year Phys. Rev. Lett.,107:171801,2011 We are aiming at ~ 6× as our goal for first stage of MEG experiment. (Year 2013) Further one-order improvement is expected in upgraded experiment. (Run start in Year 2016) MEG upgrade proposal to PSI is approved in Jan arXiv: [physics.ins-det] INTRODUCTION We are searching for the μ → e +γ decay in the MEG experiment at Paul Scherrer Institute in Switzerland with an unprecedented sensitivity. In order to achieve a higher sensitivity, we plan to upgrade the experiment, including an upgrade of the liquid xenon γ-ray detector with MPPC readout. It turned out by a simulation that the energy and position resolution will be significantly improved especially for events where γ-ray converts at a shallow part of the detector. UV-sensitive MPPC is under development to detect liquid xenon scintillation light in VUV range. Design and expected performance of the upgraded LXe detector and R&D status of UV-sensitive MPPC are presented Performance of UV-sensitive MPPC SUMMARY MEG Liquid xenon detector will be upgraded with MPPC The performance of upgraded detector is being confirmed in MC simulation. MPPCs sensitive to LXe scintillation is under development, enough high PDE (~17%) is already obtained PROSPECTS Optimization of MPPC performance is still in progress Further performance improvement is anticipated with recent breakthrough in HPK MPPC technology (HPK IEEE 2012) We are planning a prototype test with hundreds of MPPCs in 2013 Detector construction will start in 2014 Energy resolution will be greatly improved. sensor coverage becomes more uniform especially at shallow position with small sensors. Position resolution will also be improved at shallow part. Detection efficiency improves by 9%, thanks to small thickness of MPPC. Timing resolution is expected to be the same as current detector. MPPC (12mm) Comparison of light distribution of scintillation light, imaging power will be greatly improved Photon Detection Efficiency (PDE) PDE is measured from scintillation photon from α-source. Currently, the most sensitive model has PDE about 17%, which enables us to detect more photons with the upgraded detector than those with the current detector 12x12mm 2 MPPCs on PCB Dark count rate In liquid Xe temp. (165K), thermal dark noise of MPPC is ~10 5 times lower than that in room temperature. This noise level is acceptable for our detector even at larger samples. Temperature dependence of Gain & PDE Gain & PDE depend on temperature, due to the shift of breakdown-voltage. MEG aimed for 2013 goal of upgrad e The effect is small since LXe temperature is highly stabilized. setup inside xenon chamber PMT MPPC mounting board anti- reflection cylinder 241 Am α source Signal transmittance in long cables In actual xenon detector, signal must go through about 10m before readout electronics. Deterioration by different cable length is tested, and it turn out to be moderate. 3x3mm sample gain slope 2%/K PDE slope 5%/K Since MPPC signals contain effect of Cross Talk & After Pulse, PDE is corrected with its probability measured separately. ・ Replace current 2” PMTs on incident face with smaller photosensors ・ Modification in lateral PMT arrangement CG image MPP C PMT γ-ray Present Upgraded Present Upgraded γ γ We evaluated performance of the upgraded xenon detector by Monte Carlo simulation. PCB vacuum feedthrough In order to transmit more channels, we are developing PCB feedthrough. molded with epoxy MMCX connectors Coaxial like pattern is printed. Characteristic impedance 50Ω ・ Vacuum tightness ・ Signal transmittance were confirmed Concept of LXe Detector Upgrade Detector Assembly MPPCs will be mounted on long PCB, and the PCBs will be attached on inner face of xenon cryostat with thin metal wires. quartz protection Detector assembly image γ e+e+ candidates ・ MPPC ・ Smaller, square PMT ・ Flat panel PMT Depth [cm] Position resolution in σ [mm] Red : PMT (present) Blue : MPPC (upgraded) Position Resolution Development of UV-sensitive MPPC UV-sensitive MPPC is under development in collaboration with Hamamatsu. ← In commercial MPPC, most photons are absorbed by protection coating on surface. In addition, contact layer have little sensitivity because E field is weak in the layer. Improve sensitivity to xenon scintillation (λ: 175±5nm) commercially available products don’t have sensitivity to UV-light possible solutions ・ Remove protection layer ・ Reduce thickness of contact layer ・ Anti reflection coating ・ Refractive index of sensor surface better matched to LXe Large-area MPPC currently 3x3mm 2 is the largest commercial model, however it is too small for MEG γ detector. Cross-sectional image of MPPC With 12x12 mm 2 active region, ・ ~4000 channels will be needed to fill inner face. (216 channels, currently) ・ signal waveform become wider due to larger capacitance → high density vacuum feedthrough is required. (see below ”PCE vacuum feedthrough”) → parameter optimization is needed smaller pixel, lower quench resistance Red : present Blue : upgraded Signal γ-ray spectra, left and right correspond to shallow and deep part respectively. Energy Resolution σ up 2.1% ↓ 0.6% σ up 1.0% ↓ 0.5% Slant angle for better uniformity Wider inner face to reduce energy leakage Engineering Design Single Photon Countability 1 photo-electron and 2 photo- electron evens can be resolved. We succeeded to detect UV light with large-area (12x12 mm 2 ) MPPC