PASTEURIZER TUNNEL. Pasteurizer tunnel for the jars or bottles with a total surface of about 3 sqm – net dimensions of the belt conveyor width 1.000 mm.

Slides:



Advertisements
Similar presentations
Jam line Via Leonardo Da Vinci, 11 b Cassina de Pecchi (MI) Italia Tel. 0039/ Fax. 0039/ Sito.
Advertisements

MILK PLATE PASTEURIZER. Milk pasteurizer for instance the following thermal cycle or other, in relation with the product to handle. The plant will.
TRENDSETTING MINDSETS ARISE IN SMART HEADS
Series L Air conditioners for Laboratories.
HT Series – High Temperature Technology 1 INTERPUMP GROUPS NEW PUMP LINE FOR CAR WASH AND INDUSTRIAL APPLICATIONS UP TO 85°C (185° F)
Circulating Water System
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Mini 24 Presents the new. Wall-hung boiler Self diagnostic system Electronic thermometer Furnace type: open Output power: 22,66 kW Min. 6,7 kW Stars of.
COOLING AND COMFORT HEATING SYSTEMS
Basic Refrigeration Cycle
OUR ‘ISO’ CERTIFICATIONS CE Certification for our Leading Products.
UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product.
Mini Jet Sample Dyeing M/C Daelim Starlet Co., Ltd.
Via Leonardo Da Vinci, 11/b CASSINA DE’ PECCHI (MI) Italy Tel. 0039/ Fax 0039/ Sito Web :
Customer Service VICTRIX 90 Central heating only, wall hung condensing boiler.
MILK PASTEURIZER. One milk pasteuriser with a capacity of litres of milk for hours, HTST type with an operate range from 75° to 95°C, including.
Spiral Condensors. Working Principle The Spiral Condensor consists of two sheets stainless steel strips which have been wounded from the centre.
With over 60 years experience Mondial Forni ensures the highest baking quality and maximum reliability in their ovens. The Ciclomondial combustion gas.
GD150 Liquid bulk contactless compressor. GD150 Compressors.
Goulds ISO Series ISO End Suction Centrifugal Pump
KICK-OFF MEETING - Brindisi 21 July 2011 EcoPlasBrick WP2 Industrialization activities Development of an automated production system Start-up of a new.
The machine is built to comply with the accident prevention, hygiene and electric standards in force. MODUL SERIES MODULAR DECK OVENS Control panel features:
Air conditioning – Refreshes your life Applied Systems DAIKIN Fan Coil Units Comfort Applications >> FWB
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
Water piping design.
Announces the New EOS Pump Range EOS 15-C25 EOS 30-C25
COOLING AND COMFORT HEATING SYSTEMS CHAPTER 3 Page 54 Classroom Manual Page 56 Lab Manual.
INTRODUCTION Definition:
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Alan Hinton March, 2006 Slide 1 NEW! ‘YEFB’ HIGH PRESSURE BLOWER UNITS.
Sponsor: Carrier Corporation Advisor: Dr. H. El-Mounayri May 3, 2007 Design Team: Mike Abel Braden Duffin Simon Marin Joe McGuire.
CHILLED WATER AIR-CONDITIONING SYSTEMS
PASTEURISATION UNIT. Pasteurisation unit composed by: *A buffer tank for product storage made in AISI 304 stainless steel, with the following characteristics.
COOLING & VENTILATION FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 16/9/2009 CLIC TWO BEAM MODULES REVIEW
Via Leonardo Da Vinci, 11 b Cassina de’ Pecchi (MI) Italia Tel. 0039/ Fax. 0039/ Sito web:
Page 1 Sapphire by pass line  Design Concept of Cooling Water System : Funnel 10 line Tank 2 10 tones Chiller -20cm tilt - 5cm distance between growers.
MEAT CUTTING TOOLS. CUTTING TOOLS Set of meat cutting tools composed by: *One block in stainless steel with a surface of odourless non toxic polyethylene.
DRYERS FOR FRUITS AND VEGETABLES. Our dryers are successfully used to dry fruits and vegetables, like exotic fruits, tomatoes, mushrooms and sweet herbs.
CONTINUOS MONOTUBOLAR COOKER. Particular: piping of monotubular cooker.
Knit Dyeing Machines.
MVD COOLING STATUS COOLING PLANT UPDATE: -ADDITION of the NEW CIRCUITS FOR GBT AND DC-DC Converter BOARDS IN THE COOLING PLANT -THERMAL STUDY OF GBT AND.
MVD COOLING STATUS COOLING PLANT: -UPDATE of THE HYDRAULIC SYSTEM -INTEGRATION OF THE MVD COOLING CIRCUIT PATHS INSIDE THE PANDA AREA -DEFINITION OF THE.
Sorbent Handling Plant by NHI-Design & Equipment Specifications
MVD COOLING STATUS MVD COOLING PROJECT: CHOICE of COOLING FLUID,
UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product.
FRUIT CHOPPER.
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
COOLING TANK.
COOKING BASINS.
© Copyright, HQT-SV Control System
Plastic strapping machines
TUBOLAR PREHEATER.
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
Pumps and Lift Stations
20060 Cassina de’ Pecchi (MI) Italia
MEAT BLENDER.
KIWI PEELER.
WASHING MACHINE.
TUBULAR COOLER.
Air Conditioning System-1
VIBRATING TABLE.
AUTOMATIC ONION AND GARLIC PEELER
HELICOIDAL EXTRACTOR.
20060 Cassina de’ Pecchi (MI) Italia
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
OPEN TOP COOKING KETTLE
BATCH PASTEURIZATION UNITS
SODA PEELING MACHINE.
Enrobing+ wheelmachine 50Kg
Presentation transcript:

PASTEURIZER TUNNEL

Pasteurizer tunnel for the jars or bottles with a total surface of about 3 sqm – net dimensions of the belt conveyor width mm and length mm. The tunnel is divided in three sections – heating/holding ; pre-cooling ; cooling The treatment time are adjustable according to the production needs and jars size, by means of belt speed regulation through motovariator. Each sections have almost the same dimensions, so the tunnel is divided in 3 parts each one length approx mm. Some additional characteristics of the tunnel are : temperature control in the preheating and heating section are by means of termoregulator, enclosed in the electrical board, which act regulating the steam modulating valve external hood, manufactured in AISI 304 stainless steel, for suction of the steam from the first section upper covers of the tunnel, manufactured in AISI 304 stainless steel and designed at hydraulic seal proof Mechanical characteristics : execution of the structure in AISI 304 stainless steel, equipped with feet adjustable in height tunnel divided in three sections : first section – heating and holding section- by means of hot water, heated up to 98°C by means of stainless steel heat exchanger coil water/steam ; water temperature can be widely adjust according to the production needs. The unit is completed by thermal regulator with its by pass group and instruments for temperature water indication. Hot water is sprayed by means of nozzles, placed on the upper side of the belt conveyor, and completely dismountable for an easy cleaning and maintenance. TECMON S.R.L. P.IVA VIA LEONARDO DA VINCI, 11/BCOD.FISC CASSINA DE’ PECCHI (MI) TEL CAP. SOC. € ,00 INT. VERS. FAX ISCR. TRIB. DI MONZA REG. SOC MONZA E BRIANZA

Second section – pre-cooling with water at about 60°C, coming from the last section. Water from this section will be discharged by an over flow and it can be recycled using a pump, into the cooling tower. Thrid section –final cooling – is provide with manifold for the cooling water distribution from the cooling tower, equipped with modulating valve. The water is collected in a chute, placed in the lower part of the tunnel section and pumped by a proper centrifugal pump into the pre-cooling section; the pump will suct the water from a lateral and external bin completed with level control and extractable stainless steel filter grid. conveyor belt is manufactured by intralox ( see information about belt producer on : type S 400 Raised Rib in polypropylene, grey colour.The belt is suitable to resistant to the process temperature and high pressure / weight load. belt bearing in tubular stainless steel 100x50x3 belt sliding plane in AISI 304 stainless steel pressed sheet at “U” shaped and 1,5 mm thickness upper cover in AISI 304 stainless steel 1,2 mm ; hydraulic sealed proof stainless steel hood placed at the inlet of the tunnel complete with aspiration fan pulling and return axle in square tubular stainless steel 60x60 plastic diaphragm at the inlet and outlet of the tunnel transmission by chain of 1” with protection cover Consumptions : Motor : 1,1Kw Water at 2-3 bar : 1 m3/h Steam at 3-5 bar : 100 Kg/h approx TECMON S.R.L. P.IVA VIA LEONARDO DA VINCI, 11/BCOD.FISC CASSINA DE’ PECCHI (MI) TEL CAP. SOC. € ,00 INT. VERS. FAX ISCR. TRIB. DI MONZA REG. SOC MONZA E BRIANZA