TE-MPE-EE, 16-Apr-2015 1 CLIQ Power supply design J. Mourao TE-MPE-EE.

Slides:



Advertisements
Similar presentations
CommentaryVideo Hi, my name is Edward Guillergan and I’m one of AMETEK Programmable Power’s Applications Engineers. I’m here to provide an overview of.
Advertisements

Khaled A. Al-Utaibi  Clock Generator Functions  Crystal Oscillator  8284 Pins  8284 Interfacing to the 8086  RC Circuit Charging.
AP Electricity Quiz Review
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
POWER ELECTRONICS Instructor: Eng. Jalal Al Roumy The Islamic University of Gaza Faculty of Engineering Electrical Engineering Department بسم الله الرحمن.
Week 3 Electrical Circuits and Components. It’s a Radio!
DC Choppers 1 Prof. T.K. Anantha Kumar, E&E Dept., MSRIT
Interactive Engineering Workshop Eng. Mageda Al-Moubarak Eng. Fadia El-ssa.
Alternating Current Circuits
9/29/2004EE 42 fall 2004 lecture 131 Lecture #13 Power supplies, dependent sources, summary of ideal components Reading: Malvino chapter 3, Next:
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
Quiz 12.5  S 42.5 A 10.0  S ILIL The periodic waveform below represents the filter inductor current in a push-pull converter, whose output voltage is.
Digital I/O Connecting to the Outside World
GCSE Electronic Products
WATER LEVEL CONTROLLER USING 555 TIMER
TIMERS.
CLIQ power supply Integration. General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm.
TE-MPE-EE, 02-Apr CLIQ Power supply design J. Mourao TE-MPE-EE.
1 DC ELECTRICAL CIRCUITS ELECTRONIC TRAINER AND BREADBOARDING.
TE/MPE/EE J. Mourao T/MPE/EE 1 November 2012 LHC Machine Local protection Redundant Power supply (DQLPUR) - Review.
WAAM Boxing Training Utility Warren Anderson Alexander Stewart Mark Craig Avinash Ramlall.
9/27/2004EE 42 fall 2004 lecture 121 Lecture #12 Circuit models for Diodes, Power supplies Reading: Malvino chapter 3, Next: 4.10, 5.1, 5.8 Then.
MICE Decay Solenoid Quench Detector Trevor Hartnett Daresbury Laboratory.
TE-MPE-EP, VF, 11-Oct-2012 Update on the DQLPU type A design and general progress. TE-MPE Technical Meeting.
AN-NAJAH NATIONAL UNIVERSITY DEPARTMENT OF ELECTRICAL ENGINEERING Investigation On a Microcontroller-Triggered Single Phase Thyristor Bridge PREPARED BY:
AN-NAJAH NATIONAL UNIVERITY DEPARTMENT OF ELECTRICAL ENGINEERING THREE PHASE THYRISTOR BRIDGE CONTROLLED BY MICROPROCESSOR PREPARED BY: NABEEL MASSRI MOUSA.
TE/MPE/EE J. Mourao T/MPE/EE 1 November 2012 LHC Machine Local protection Redundant Power supply (DQLPUR) & interface Module (DQLIM) progress status.
Overview of the CLIQ Units Project
CLIQ unit Integration. General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm. Capacitors Capacitors.
MICE RF System Power Supplies, Control and Monitoring Status report February 2012 Chris White, STFC Daresbury Laboratory MICE Collaboration Meeting CM32,
Acquisition Crate Design BI Technical Board 26 August 2011 Beam Loss Monitoring Section William Vigano’ 26 August
Determine the mathematical models that capture the behavior of an electrical system 1.Elements making up an electrical system 2.First-principles modeling.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
Automated Control System
Phasors and Kirchhoff’s Current Law
Introduction to DC-DC Conversion – Cont.
Unit 13 Electric Circuits
SMV Electric Tutorials
TRIGGER DELAY 100µs. G. Gräwer AB/BT/ECLBDS Trigger Delay2 The trigger delay is a back-up system that generates an asynchronous dump trigger for MKD and.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
7. Direct Current circuits. 11 Find the currents, which flow in all the wires of the circuit in this figure 12  9 V 6 V b a cd 18 
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Reverse Parking Sensor Circuit.
Auto turn off battery charger Auto turn off battery charger.
Simple Circuits 1 st year physics laboratories University of Ottawa
Capacitors Capacitors Gateway To Technology®
Chapter 9 CAPACITOR.
How to Build a Digital Physical System - Lab Lecture 2.
Capacitors in Circuits. Some applications Storing large amounts of charge for later release e.g., camera flash, defibrillator Computer interface components.
ADVANCED WATER LEVEL CONTROLLER
CAPACITANCE METER Tests capacitors from 1p to 10u, in 6 ranges.
Residential Cabling Technologies Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Electrical Measurements.
Simple Circuits 1st year physics laboratories University of Ottawa
Simple Circuits 1st year physics laboratories University of Ottawa
INDUSTRIAL ELECTRONICS/ELECTRICITY
MICE RF System Power Supplies, Control and Monitoring Status report
Presentation 3 – Team 6 Brian Gallert Detailed Block Design
Design of new generation CLIQ units (CLIQ2)
FMEA of a CLIQ-based protection of D1
Administrative stuff Turn in your HW #3!
CLIQ Coupling Loss Units & HDS Quench Heater Discharge Supplies - a short description of these safety-critical components for LHC machine protection.
Power Block Implementation
How to avoid catching things on fire.
The Automatic Weather Station (AWS)
Reading: Malvino chapter 3, Next: 4.10, 5.1, 5.8
Module 1 – Power Supply AMC APS-PBC-60
Dr. Unnikrishnan P.C. Professor, EEE
ACOE347 – Data Acquisition and Automation Systems
More Circuit Components: Capacitors, Inductors, and Diodes
Linear Electromagnetic Accelerator
Presentation transcript:

TE-MPE-EE, 16-Apr CLIQ Power supply design J. Mourao TE-MPE-EE

TE-MPE-EE, 16-Apr Topics  CLIQ Power supply Electronic Design –Overview –Capacitor charger –Trigger signal generator circuit –Thyristor driver circuit –Test of the trigger and discharge circuit  User interface  User Safety  Design & Production Status

TE-MPE-EE, 16-Apr Overview Mains Input Trigger Circuit Discharge circuit Capacitor charger Capacitor Bank (non polarized) : -40 or 80 [mF] charged at max. 500V -max. stored energy 10 [KJoule] Current supplied in the superconducting magnet

TE-MPE-EE, 16-Apr Capacitor charger  Currently being designed & manufactured by SDS Performance  technical specification: -Boxed in a 3U/10TE Europe cassette (220mm deep) -100[mA] charging current to charge the 80[mF]capacitor bank to 500V in 6.7 minutes -Front panel: -2 LCDs (Ucap, Icharge) -2 LEDs (end of charge, remaining capacitor Voltage > 40VDC) -1 commutator to select Charging voltage by steps of 50[V] -Rear connector (din41612, H15 Male): -Mains input 110/220 VAC -On/Off command controlling the output stage -2 digital outputs for(end of charge, Ucap>Utrim) -Analog reading of Ucap Front Panel:

TE-MPE-EE, 16-Apr Thyristor driver Two thyristors assembled in a single box. (ABB 5STB24N2800). Gate current needed to fire the thyristors: Superconducting Magnet load Current in the thyristor during the energy deposit (in the load):

TE-MPE-EE, 16-Apr Trigger signal generator circuit To trigger the Power supply, the user as to release the 10VDC that he was continuously supplying 500[ms] pulse generator 12 [KHz] square Wave 500ms positive 12Khz pulse train

TE-MPE-EE, 16-Apr Resistive load 30 [ohms] to create a 8 A rms current in the thyristors Test of the trigger and discharge circuit (1/2) Use of mains to simulate the Oscillating effect of ta superconductive magnet load A 100 [ms] pulse train triggers the two thyristors Two Thyristor used in the 13kA EE BCMs (ABB 5STF06D1220)

TE-MPE-EE, 16-Apr Test of the trigger and discharge circuit (2/2) - When the current crosses the zero region, a high frequency noise is observed in a resistive load. Not annoying in our application! - 13Khz pulse train -40[us] ON / 35[us] OFF -Max. gate current 2.4 [A]

TE-MPE-EE, 16-Apr User interface  Front panel: –LCD monitoring: Ucap, Icap(charge current) –Led monitoring: Ucap>40V (RED), END of charge(GREEN) –Voltage setting: 0-500VDC by steps of 50 VDC (commutator) –“Start charge” push button  Rear panel: –Mains input (Burndy VDE) –Power output (+ and - 400A connectors) –Signal Inputs: Trigger input signal (10 VDC) –Signal outputs: Capacitor voltage (1:100) Discharge current End of charge Mains Input End of charge Trigger input Discharge current Power output Capacitor voltage “Start charge” push button

TE-MPE-EE, 16-Apr User safety –ON/OFF SWICH (goes in Off position in case of a power cut) (on the front panel) –Equipment stop (on the front panel) for disconnecting the capacitor charger and empty the energy stored in the capacitors –Automatic capacitor discharge when mains is turned off/ disconnected Discharge Time constant = 20[s] After 3 time constants Ucap< 5% of initial voltage. In the worst case(initial ucap 500V)- > After 1 [min] Ucap< 25VDC 247[ohm] / 1200W Resistor bank. To discharge the capacitors bank in 1 min

TE-MPE-EE, 16-Apr Design & production Status  Has to be completed in the design domain : –“Fine-tuning” of the trigger circuit (Bozhidar Panev) Add a function to inhibit the trigger input if these one stay at zero more than 500[ms] (to avoid a continuous pulse train) –Drawing of the PCBs (trigger board, discharge board) –Drawing a proper electrical schematic (with SI electrical) to detail the internal wiring of the rack and the 3U control chassis ( Yan Bastian’s help requested ) –Some components have still to be precisely defined: TI for the discharge current measurement (6000A pic) (Bo) Power switch for the two capacitances selection (Arend Dinus) Circuit breaker, AC filter, ON-OFF switch…  Production status: –We have already at Cern few components: Racks, Capacitors –We ordered and will get in 3 weeks: the thyristors, the capacitor chargers –And a lot of items have still to be ordered ( components, PCBs, mechanics, …)