Contaminant Control: a New Approach David Burns Scientific Process Solutions a division of Perry Equipment Corporation.

Slides:



Advertisements
Similar presentations
CM 4120 Julie King Original Presentation by Todd King and I edited it.
Advertisements

MicroMistTM Wet Scrubber Advanced Scrubbing Technology
St. Eustatius drinking water production
Drew Hevle. NACE Houston Section Principal Corrosion Engineer
HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)
Brad Buecker Process Specialist Kiewit Power Engineers.
Topics Introduction Types of Lubricants Viscosity Viscosity Ratings
Lecture 4.
Air Pollution Chapter 5.
Part 4.3 Gas Processing.
GENERAL IDEAS IN AIR POLLUTION CONTROL
Objectives: Understand importance of utility and maintenance system in industry/plant.
Chapter 4: Crude distillation
FLOW VELOCITY REQUIRED FOR SOLIDS MOVEMENT IN OIL AND GAS PIPELINES JOHN S SMART JOHN SMART CONSULTING ENGINEERS HOUSTON TX BLACK POWDER IN PIPELINES JOHN.
Black Powder Removal from Transmission Pipelines Diagnostic & Solutions Lindsay McRae – Pall Australia Kaustubh P Chitale – Pall India.
General Quotes… Contamination is the greatest single cause of lubricant malfunction and subsequent excessive wear of parts – (Mobil Oil) Prevention is.
Chapter 3: Bioreactor Design
Section 1: What Causes Air Pollution?
Dr. Mohammed M. Amro Petroleum Engineering Dept. King Saud University Effect of Scale and Corrosion Inhibitors on Well Productivity in Reservoirs Containing.
Principles of Liquid Flow through Pipelines
POWER PLANT.
Fuel Gas Conditioning Systems. Wide Variety From Pipeline.
TM Filtration A leader in Gas Filtration Technology Walnut Street, Erie, PA COALESCING.
B OILER Presented by: Muhammad Azffar Mohamad Hanif bin Yusof Nor Aminah bt. Mohd Khalil
Miscellaneous Process By: Dr. Tahseen Ismail By: Dr. Tahseen Ismail.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Designing an Internal Corrosion Program NACE Eastern Area Conference Roy D. Fultineer Jr.
Climate Change and Acid Rain
Process Overview After a gas well is completed the gas is typically drawn from the well via a self containing portable skid containing a driver, compressor.
INTRODUCTION Definition:
07/ This document is the property of SNF. It must not be reproduced or transfered without prior consent Enhanced Oil Recovery Optimizing Molecular.
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
Fossil Fuels Chapter 19.
Basics of the Oil, Gas & Petrochemical Industries.
Clark Reliance Corporation Strongsville, OH. Fuel Gas Treatment.
Jeopardy Properties Of Matter States of Matter/ Physical & Chem- ical Changes Mixtures and Solutions Separating Mixtures Wild Card Q $100 Q $200 Q $300.
Facilities Engineering *1 st draft By: Saha. Development options ProposalDevelopment OptionEstimated Cost (Mil) A FPSO converted to Tanker Hull 300 kbo.
MIXTURES, SOLUTIONS AND PURE SUBSTANCES. Matter and its appearance  According to its appearance, there are two kinds of material systems:  Homogeneous.
PHYSICAL AND CHEMICAL PROPERTIES Sections 2.2 and 2.3.
Power Generation Turbines
Pharos University جامعه فاروس Faculty of Engineering كلية الهندسة Petrochemical Department قسم البتروكيماويات LECTURE (11) NITRIC ACID PRODUCTION 6-6Contact.
Objectives Name five primary air pollutants, and give sources for each. Name the two major sources of air pollution in urban areas. Describe the way in.
Seminar Report On KOTA SUPER THERMAL POWER STATION Submitted in partial fulfilment for the Award of degree of BACHELOR OF TECHNOLOGY In Electrical Engineering.
Matter: Chapter 2 Lesson 3: What are mixtures?. A mixture is a combination of two or more substances. Substances in a mixture can be separated. This means.
Separators Types of Dust Separator Cyclone Separator working & types Critical Parameters Advantages Disadvantages Applications maintenance.
SAGD (De-Oiling) Solutions. SAGD Produced Fluid Separation requirements: Sand Removal: continuous, batch process, in tank separators Oil Removal: cyclones,
Lecture 4 Classification of Mixtures Solutions Solubility Water Treatment.
VISHWAKARMA GOVT. ENGG. COLLEGE TOPIC : DISTILLATION OF PETROLEUM SUPERVISED BY : K.K.GURJAR.
Refrigeration Systems
Production Engineering II
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
CFD Simulation & Consulting Services Hi-Tech CFD | Voice: Optimizing Designs of Industrial Pipes, Ducts and.
 2007 Kaeser Compressors, Inc., USA (V5.0) 1 Kaeser Compressed Air Filters Specifications are subject to change without notice.
PNEUMATICS Chapter 5 Secondary Air Treatment
Heater-Treater Units Heater-Treater Units PTRT xxxx Chapter xx
Natural Gas Production Chapter 6 Misc. Gas Conditioning
Advancements in Fuel and Lube Oil Inspection Technology
Natural Gas Processing I Chapter 2 In-feed System
Natural Gas Production Chapter 4 Hydrate Formation
PRODUCTS (POWER PLANT)
Control of Sulfur Oxides Dr. Wesam Al Madhoun
Basics of the Oil, Gas & Petrochemical Industries
Refinery: Separation units
Filtration Reading Materials:
Treatment of Produced Fluids: Crude Oil and Water:
Mohr Separations Research, Inc.
Large Air Systems – Sales Training
UNIT III PARTICULATE SCRUBBES. PARTICULATE SCRUBBERS or WET COLLECTORS Scrubbers are air pollution control devices that use liquid(often water) to remove.
Pneumatic System Conditioning
Presentation transcript:

Contaminant Control: a New Approach David Burns Scientific Process Solutions a division of Perry Equipment Corporation

n Scientific Process Solutions (SPS) is a division of Perry Equipment Corporation (PECO) that offers field contaminant measurement and consulting services. n SPS serves the natural gas transmission and processing, chemical processing, refining, and power generation industries. Introduction

Contaminants and Contaminant Mixtures n Contaminant Types –Solids –Liquids –Semi-solids –Foams –Emulsions

n Common solid contaminants –Formation solids (reservoir and frac sand) –Corrosion solids (iron sulfide, iron oxide) –Precipitating solids (elemental sulfur, salt compounds) Solids

Formation Solids Formation Solids

Corrosion Solids (Iron Sulfide)

Sulfur Compounds Precipitating Solids

Siloxane Compounds Precipitating Solids

n lube oil n salt water or brine n water condensate n hydrocarbon condensate n crude oil n glycol (TEG) n gas processing amines n corrosion inhibitors n biocides n foaming agents n defoaming agents n mecury Liquids

n Semi-solids are usually mixtures of solid and liquid contaminants Semi-solids

n Foams are mixtures of gases and liquids Foams

n Emulsions are mixtures of different liquids and gas Emulsions

Contaminants and Contaminant Mixtures n Each of these different types of contaminants and contaminant mixtures can cause serious process problems if the filtration separation system is not properly designed to handle them. n Hard to remove contaminant mixtures are more common than ever due to increased use of well head and pipeline injection chemicals. n Greater contaminant removal performance is required today, due to the increased use of industry technology like formulated processing solvents, membrane separators, gas fired turbines, LoNox nozzles and burner tips.

n Filtration technology has greatly advanced over the last few years to meet industry’s need for improved performance. n This advancement in new filtration technologies makes the equipment selection process even more difficult. Filtration & Separation Devices

Filtration & Separation Devices Gas Filters

Filtration & Separation Devices Liquid Filters

n A system’s contaminant content and properties dictate the separation technology used. n It is important to provide detailed scientific data on a system’s contaminant species on RFQ process data sheets. n Detailed scientific data on a system’s contaminant species will help insure that filtration separation technologies are selected that will provide the required removal efficiency at an optimum operational cost. n Optimally designed filtration and separation equipment will save money. The Contaminant Dictates the Method

Field Experiences Example 1

n This processing facility had 4 coalescers experience a decrease in removal performance. n The additional vane mist extractor had been selected for use on the coalescers to handle high liquid loads. n However, over 4 years time the extreme solids loading eventually plugged off the drainage ports of the vane mist extractors, sending more liquid to the coalescer elements than they could handle. n Had up front contaminant testing been done on this system, the large solids load would have lead filtration designers to use a different technology to protect the coalescer elements for the system’s high liquid and solids contaminant content. Field Experiences Example 1

n The Solution –Solvent and steam cleaning failed. –Coalescers had to be cut open to be cleaned. –Coalescers were put back into service. –Bulk solids loading removal technologies are being reviewed for installation upstream of the coalescers. Field Experiences Example 1 Field Experiences Example 1

n A custody transfer station was having problems with liquid contamination fouling pressure control and measurement equipment. n A surplus filter separator was sized for the gas flow rate and installed to eliminate the contamination causing the problems. Field Experiences Example 2

n The problems continued. n SPS was hired to test the contaminant loading entering and exiting the filter separator. Field Experiences Example 2

n The inlet gas stream was measured to contain 98 liters per day of free liquid contaminant entering the filter separator. n The filter separator outlet gas stream was measured to contain 98 liters per day of free liquid contaminant entering the filter separator. n The liquid was identified to be lube oil with a surface tension of 28 dynes/cm. Field Experiences Example 2

n Conclusion –The liquid contaminant’s surface tension was too low for a filter separator to work properly. n The Solution –A slug catcher and high liquid loading horizontal coalescer were installed in place of the filter separator. n The Result –Test results of the new system measured an outlet contaminant content of 0.43 PPB(wt) or about liters of carryover per day. –Pressure control and measurement equipment are now working properly. Field Experiences Example 2

n This gas element came under attack from a contaminant that was not chemically compatible with it’s media material. n It is important to study the chemical compatibility of all of a system’s contaminant species with any filter materials that might be used. n This is a case where a filter element problem can go undetected contaminating downstream processes. Field Experiences Example 3

n The Solution –A chemically compatible element material was selected and installed in service. –No other process problems have been reported. Field Experiences Example 3

n A natural gas fired turbine failed it’s NOx emissions requirement. n The turbine’s LONOx fuel gas nozzles were found to be damaged and partially plugged off with contaminant. n The LONOx nozzles were protected by a 1 micron filtration separation system. Field Experiences Example 4

n Conclusion –The standard 1 micron filtration vessel was not efficient enough for the system’s contaminant size. n The Solution –A 0.3 micron high dirt loading coalescer vessel was installed. n The Result –The turbine passed it’s next NOx emissions test. –No additional nozzle damage has occurred. Field Experiences Example 4

n A gas processing facility was experiencing plant iron sulfide contamination resulting in excessive TEG and amine filter element changes. n The system’s inlet gas 0.3 micron coalescer was tested and found to be allowing iron sulfide contamination to pass downstream. Field Experiences Example 5

n Conclusion –The standard 0.3 micron element technology was not sufficient to remove the system’s iron sulfide contaminant. –Dry pipeline conditions and high velocities worked to shear the iron sulfide contaminant size distribution to be partially under 0.3 microns in size. n The Solution –An iron sulfide removing element technology was installed in the existing coalescer. –An upstream water wash system was also installed. Field Experiences Example 5

n The result –Down stream element life was extended by 7 times. –The water wash system worked with the iron sulfide element technology to wash the contaminant off of the coalescer elements extending their life to over a year and counting. Field Experiences Example 5

n Gather information on your system’s contaminant species before entering the bidding process. n Have liquid samples from the system or at least a nearby system analyzed for identification, surface tension, viscosity, pH, density, total suspended solids loading, and solid particle size. n If possible, have the system on-line tested for contaminant loading and size. Testing done on-site will provide important contaminant content data that is not available from laboratory tests. A New Approach

Field Testing Protocols DCM (Direct Contaminant Measurement Laser Testing) CCM (Coalescer Contaminant Measurement Testing) SCM(Solids Contaminant Measurement Filter Disk Testing)

A New Approach DCM Direct Contaminant Measurement

A New Approach DCM Direct Contaminant Measurement DCM Specifications The DCM protocol utilizes a high pressure laser particle counter to measure and quantify aerosol contaminant in a gas stream. The protocol is used for testing down stream of coalescers, Gemini Purasep units, and filter separators. n Measurement range micron n Operating pressure range psi n Operating temperature range deg. F n Maximum aerosol content 30 ppm n Maximum gas velocity 30 ft/sec

A New Approach CCM Coalescer Contaminant Measurement

A New Approach CCM Coalescer Contaminant Measurement CCM Specifications The CCM test coalescer system is designed to measure free liquids and aerosols in almost any application. The CCM unit is commonly used for testing gas separators and scrubbers. The unit can also be used to quantify the inlet gas streams to coalescers, Gemini Purasep units, and filter separators. n Liquid collection range 0.3 micron - free liquid n Operating pressure range psi n Operating temperature range deg F n Testing sample line size 1/2” - 1”

A New Approach SCM Solids Contaminant Measurement

A New Approach SCM Particle Sizing Laboratory Equipment

A New Approach SCM Solids Contaminant Measurement SCM Specifications The SCM testing protocol is used to quantify solid or semi-solid contaminant content in a gas stream. Microscopic analysis can be added to provide a particle size distribution. n Operating pressure range psi n Operating temperature range deg f

n Provide the contaminant data on filtration separation specification data sheets for E&C’s to include during the bidding process. n Performance verify new and existing filtration and separation equipment. Include performance verification in initial equipment scope of supply. n Have process optimization studies done for your plant or facility’s contaminant control equipment. A New Approach

n The Result –Scientific contaminant data provided on RFQ data sheets will result in the purchase of filtration separation systems that will provide optimum operational performance at an optimum capital and operational cost. –Performance verification of new and existing equipment will identify problems before additional damage to expensive downstream equipment occurs. –Process optimization studies of contaminant control systems will lower overall plant operational cost. A New Approach

Thank you for your kind attention.