The ventilation of the future.. What is EC? AC – Asynchronous motor.

Slides:



Advertisements
Similar presentations
December 2005 EuP Directive : A Framework for setting eco-design requirements for energy-using products European Commission.
Advertisements

Energy Using Products Directive Mark Shayler. Why? ? Rising level of electrical waste Shift in legislation Waste disposal and clean-up costs Resource.
The European Lighting Industry Position on How to Maximise the Potential Benefits of European Policy on Energy Efficiency in Lighting January 2008.
COPYRIGHT © 2014 MITSUBISHI ELECTRIC EUROPE B.V. ALL RIGHTS RESERVED.
Fans and Blowers.
Compliance With Resolution 0859 – Safety of Persons Underwriters Laboratories Inc. March 2008 Refrigerators, Freezers and Combination of Refrigerator-Freezers.
Sustainable Road Transport Upcoming legislative proposals from the EU Antje Fiehn Federation of German Industries.
Avril 2013 Super crédits CO2 – argumentaire FGMM 1 CO2 Regulation for cars 2020 targets Meeting of IndustriAll Europe Trade Unions Automotive – April 8th,
EU Tire Label. April 2011 Tire Performance Label: A Global TrendTrend 2 EU World wide introduction of a tire label EU-Label for the performance in Rolling.
BC 3722 HVAC Engineering Semester A 2003/04 Dr. Richard K K Yuen Department of Building & Construction.
ME 2205 ELECTRICAL DRIVES AND CONTROL UNIT I INTRODUCTION BY B.DURAI BABU A.P/EEE.
Enterprise and Industry Directorate-General Agnieszka Kozakiewicz Automotive Industry Unit (F1) Enterprise and Industry Directorate-General European Commission.
4 good reasons why Energy Efficiency is Important.
DATA ONE, EUROPEAN OPERATIONS CENTRE, ST. PETERSBURG, RUSSIA Presentation of Design Proposal.
Condensation Solutions “Breathe easy…”. Cost effective solutions for condensation and mould.
Short Summary from second Meeting of the Ecodesign CF Subgroup on Large Power Transformers Brussels Distribution Transformers (medium PT) Power.
Dr. Lajos CSEPI (State Secretary for Transport ) Hungary CLIMATE CHANGE: ENERGY AND TRANSPORT Issues, challenges and strategies in Hungary.
Part 2 - Dilution Ventilation (General Ventilation)
Europump's Pump Efficiency Program HI Annual Meeting 2012 St. Petersburg, Fl.
Management and Organisation of Electricity Use Variable Speed Drives Belgrade November 2003.
ROAD TRANSPORT SECTOR IMPLEMENTATION OF SELECTED MEASURES AND INTERNATIONAL AGREEMENTS Chişinău 2011.
Fans.
European Commission Enterprise and Industry New EU Regulation for the approval of 2-3 wheel vehicles and UNECE Regulations on sound level Working party.
A joint initiative of Australian, State and Territory and New Zealand Governments. Overview of the Non-Domestic Fan Product Profile Ian McNicol, Sustainability.
European Commission Enterprise and Industry GRPE meeting - 08/06/2012 | ‹#› Workshop - stakeholder consultation International environmental and propulsion.
A joint initiative of Australian, State and Territory and New Zealand Governments. Overview of the Non-Domestic Fan Product Profile Ian McNicol, Sustainability.
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
Partner for progress Safety and quality requirements for mCHP products Falco Thuis Kiwa Gastec Certification May 2008.
Overview of EU Regulations affecting the use of Fluorinated Greenhouse Gases Tim G.A. Vink Director Regulatory Affairs, Compliance & QA Honeywell Fluorine.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Energy Efficient Motors. Upgrading even one, 0.75 kW motor to a Premium Efficient motor gives double benefit of Energy Savings and Carbon credits....
General Safety Regulation ACEA discussion paper Renzo Cicilloni Director Safety Paris, June 2009 AEBS/LDWS
Ecodesign Directive and Its Impact on Product Development Iain Notman Sustainable Energy Using Products 16 March 2011.
Global Ventilation Equipment Market Share, Global Trends, Analysis, Research, Report, Opportunities, Segmentation and Forecast,
Energy Ecodesign and Energy Labelling of Heaters.
Waste Electrical & Electronic Equipment (WEEE). Waste Electrical and Electronic Equipment (WEEE) Directive Work started in the year 1994 To device a strategy.
June SURVEY OF EUROPEAN DIRECTIVES European directives are based on the new approach in order to provide free movement of goods in the single market.
Metso - Slurry Pumping.
Administrative Burden in Impact Assessments for Commission proposals August 2013 – February 2014 Dr. Marianne Klingbeil Deputy Secretary-General European.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
EXECUTIVE ROUNDTABLE SERIES Aviation in the EU Emission Trading Scheme Sophie Hagège, M&A Partner June 3, 2010 KEY LEGAL CONSIDERATIONS GOVERNING THE NEXT.
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 28/7/2009 Already presented by C. Martel/ J Inigo Golfin on15 th October 2008 CLIC WORKSHOP.
Energy Efficiency Climate Change Emission Control Workshop in Prague, 20 November 2008 Opening by Friedrich P. Busch Director General EPEE, Brussels.
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
PRESENTATION TITLE GOES HERE Cooling Trends Data Center Storage.
The IED/ELVs as seen through the Eyes of a User of Combustion Plant Dr Tim Rotheray.
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL CERN TS/CV Wednesday 9 th July 2008 CLIC.
Electric safety requirements in European Community vehicle type-approval legislation GRSP ELSA sub-group – 6 th meeting Brussels, Belgium, April.
Theoretical Consideration Choose the best design Study the efficiency of energy conversion at specific speed. Power Coefficient Tip Speed Ratio Conversion.
L.J.INSTITUTE OF ENGINEERING AND TECHNOLOGY compressors Shah Aadishkumar Aileshbhai (enrollment no ) (div A roll no. 55) Guided by Mr.hemangsir.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Ventilation for buildings - Calculation methods for the determination.
Testing Room Heaters Fired by Solid Fuels for CE Marking and DEFRA Smoke Tests By allan wilson Senior Test Engineer BSRIA TEST.
Energy Meeting with the NGOs Taipei, 25 September 2013 Christian Kirchsteiger European Commission, Directorate-General for Energy (DG ENER) EU Policy Context.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Ventilation for buildings Energy performance of buildings Guidelines.
Conference “Experience of Conformity Assessment (Notified) Bodies in the EU and Slovenia” Ljubljana, April 19, 2016   TCL Experience as a Conformity.
Subsidizing High Efficient electric motors in the Netherlands October 2010.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 How does ventilation impact global energy consumption- EN
EC Regulation N. 640/2009 and its effects on the induction motors energy efficiency test methods with … EC Regulation N. 640/2009 and its effects.
Power Electronics and Control in Wind Energy Conversion Systems
Energy Efficient Building Components
EET 422 EMC & COMPLIANCE ENGINEERING
Energy Saving Concepts with Variable Speed Drives
EC Fan Basics. Electronically Commutated (EC) Motor Plug Fan Technology and Application.
Ecodesign and Energy Labelling In Europe
SCP in the 7th Environmental Action Programme
Energy efficiency in buildings
Potential Benefits for Market Transformation to Inverter A/C
Presentation transcript:

The ventilation of the future.

What is EC? AC – Asynchronous motor

EC – Electronically commutated motor

EC motor-driven fans The use of energy efficient, EC-motor driven, fans results in higher efficiencies. Easy control: CO 2 Humidity Temperature Pressure Constant air volume Stepless speed control EC on average uses 30% less power than AC In some applications in excess of 50%

Energy consumption

Speed control

Efficiency

Legislation EU adopts The Kyoto Protocol Aim: Reduce emissions by 20% by 2020 Directive: Mandatory for all 27 EU countries All fans sold or imported in Europe

EuP/ErP Lot 6Lot 10Lot 11 Roof and box fans Fans < 125 W Fans 125 W to 500 kW EuP / ErP Motors 0.75 kW to 500 kW

EuP/ErP – Lot 11 Lot 6 Lot 10 Lot 11 Roof and box fans Ventilatoren < 125 W Fans 125 W to 500 kW EuP / ErP IE2 Motors 0.75 kW to 500 kW IE3

Lot 11 - Motors How does Lot 11 impact motors? IE3 > 7.5 KW IE2 IE3 > 0.75 KW

Legislation – Motors Implemented 16 th June IE2 IEC - International Electrotechnical Commission IEC : 2007 IEC : 1996 (EFF) EXP Nov 1 st 2010

Motor efficiencies High Efficiency Low Efficiency EFF 1 EFF 2 IE4 Super Premium (Proposed) IE3 Premium Efficiency IE2 High Efficiency IE1 Standard Efficiency

Exceptions

Lot 11 - Fans Lot 6Lot 10Lot 11 Roof and box fansFans < 125 W Fans 125 W to 500 kW EuP / ErP ? ? Efficiency requriement 1 Efficiency requirement 2

EuP directive – Lot 11 Between 0.125KW and 500KW input Applies to: Fans integrated in a unit Stand alone units

What fans are affected? All fan types Axial fans Forward curved centrifugal/radial bladed Backward curved centrifugal without housing Backward curved centrifugal with housing Cross flow Mixed flow

Exceptions Atex fans Emergency smoke extract Railways (Transportation) Kitchen hoods - Less than 280W Laundry dryers - Less than 3KW Box fans

Exceptions Brussels, XXX C(2010) YYY final Article 1 Subject matter and scope 1.This Regulation establishes ecodesign requirements for the placing on the market or putting into service of fans, including those integrated in other energy-related products as covered by Directive 2009/125/EC. 2.The Regulation shall not apply to fans integrated in: (i)products with a sole electric motor of 3 kW or less where the fan is fixed on the same shaft used for driving the main functionality; (ii)laundry and washer dryers ≤ 3 kW maximum electrical input power; (iii)kitchen hoods < 280 W total maximum electrical input power attributable to the fan(s). 3.This Regulation shall not apply to fans which are: (a)designed specifically to operate in potentially explosive atmospheres as defined in Directive 94/9/EC (b)designed for emergency use only, at short-time duty, with regard to fire safety requirements set out in Directive 89/106/EC (c)designed specifically to operate: (i)a.where operating temperatures of the gas being moved exceed 100ºC; b.where operating ambient temperature for the motor, if located outside the gas stream, driving the fan exceeds 65°C; (ii)where the annual average temperature of the gas being moved and/or the operating ambient temperature for the motor, if located outside the gas stream, are lower than -40ºC; (iii)with a supply voltage >1 000 V AC or >1 500 V DC; (iv)in toxic, highly corrosive or flammable environments or in environments with abrasive substances.

Existing systems Do not have to replace or modify before the ErP start date. ErP non-compliant fans can be retrofitted up to 31 st Dec After 1 st Jan 2015 these fans will also have to comply with the then current ErP directive.

What now? Fans will have to adhere to the minimum efficiency levels. Defined at the best operating point based on electrical power input. Efficiency of the complete fan is assessed.

Fan typesMeasureme nt category Efficiency category Power range P in kW Target energy efficiencyEfficiency grade (N) ab Efficiency grade (N) ab Axial fanA, Cstatic0.125 ≤ P ≤ 10η target = 2.74 ∙ ln(P) – N < P ≤ 500η target = 0.78 ∙ ln(P) – N B, Dtotal0.125 ≤ P ≤ 10η target = 2.74 ∙ ln(P) – N < P ≤ 500η target = 0.78 ∙ ln(P) – N Centrifugal forward curved fan and centrifugal radial bladed fan A, Cstatic0.125 ≤ P ≤ 10η target = 2.74 ∙ ln(P) – N < P ≤ 500η target = 0.78 ∙ ln(P) – N B, Dtotal0.125 ≤ P ≤ 10η target = 2.74 ∙ ln(P) – N < P ≤ 500η target = 0.78 ∙ ln(P) – N Centrifugal backward curved fan without housing A, Cstatic0.125 ≤ P ≤ 10η target = 4.56 ∙ ln(P) – N < P ≤ 500η target = 1.1 ∙ ln(P) – N Centrifugal backward curved fan with housing A, Cstatic0.125 ≤ P ≤ 10η target = 4.56 ∙ ln(P) – N < P ≤ 500η target = 1.1 ∙ ln(P) – N B, Dtotal0.125 ≤ P ≤ 10η target = 4.56 ∙ ln(P) – N < P ≤ 500η target = 1.1 ∙ ln(P) – N Mixed flow fanA, Cstatic0.125 ≤ P ≤ 10η target = 4.56 ∙ ln(P) – N < P ≤ 500η target = 1.1 ∙ ln(P) – N B, Dtotal0.125 ≤ P ≤ 10η target = 4.56 ∙ ln(P) – N < P ≤ 500η target = 1.1 ∙ ln(P) – N Cross flow fanB, Dtotal0.125 ≤ P ≤ 10η target = 1.14 ∙ ln(P) – N < P ≤ 500η target = N

Regulation enforcement UK Market Surveillance Authority (MSA) Eco-design directive National Measurement Office For more information:

End of presentation Thank you for listening.