WELCOME. UV Spectrophotometric Method Development And Estimation of Bicalutamide in Pharmaceutical Dosage Form.

Slides:



Advertisements
Similar presentations
Introduction to Spectrophotometry & Beer’s Law
Advertisements

Instrumental Analysis
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
UV / visible Spectroscopy
What is Spectroscopy? The study of molecular structure and dynamics through the absorption, emission and scattering of light.
Chapter Eleven Ultraviolet-Visible Spectrophotometry
Spectrophotometry Chapter 17, Harris
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
UV / visible Spectroscopy
Outline Final Comments on Titrations/Equilibria Titration of Base with a strong acid End-point detection Choice of indicators Titration Curve method Start.
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Scanning spectrophotometry and spectrophotometric determination of concentration BCH 333 [practical]
Scanning spectrophotometry and spectrophotometric determination of concentration BCH 333 [practical]
Chemometrics Method comparison
Introduction to Instrumental Analysis - Spectrophotometry
Instrumental Analysis
Validation of Analytical Method
Simultaneous quantification of bergenin, catechin, and gallic acid from Bergenia ciliata and Bergenia ligulata by using thin-layer chromatography 张 慧.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Chapter 26 Molecular Absorption Spectrometry Molecular spectroscopic methods are among the most widely used of all instrumental analytical methods. Molecular.
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
1 Spectroscopic ANALYSIS Part 5 – Spectroscopic Analysis using UV-Visible Absorption Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett.
SPECTROPHOTOMETRY IN BIOTECHNOLOGY
INTRODUCTION AND OBJECTIVES COMPARATIVE DETERMINATION OF ZINC IN PHARMACEUTICAL PRODUCTS CORCIOVĂ ANDREIA, CIOBANU CONSTANTIN “Grigore T. Popa” University.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Spectrophotometry.
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Outline Start Chapter 18 Spectroscopy and Quantitative Analysis.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Determination of Concentration Using Spectrophotometry
SPECTROPHOTOMETRY PRACTICAL 213 PHC INSTUMENTAL ANALYSIS.
Scanning spectrophotometry and spectrophotometric determination of concentration BCH 333 [practical]
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
SPECTROPHOTOMETRY IN BIOTECHNOLOGY. LIGHT IS A TYPE OF ELECTROMAGNETIC RADIATION Imagine electromagnetic radiation like waves on a pond – But instead.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
EQUIPMENT and METHOD VALIDATION
Absorption spectrum and spectrophotometric determination of concentration Experiment 1.
For routine use, the biuret procedure is simple to perform, producing a stable color that obeys Beer's Law. UV-Vis Spectroscopy is primarily used.
Introduction to Spectrophotometry
UV/VIS SPECTROSCOPY.
Quantitative tests for proteins
SwethaBhavani N, HimaBindu S, Venkateswara Rao A, Panikumar D Anumolu
Spectroscopy Techniques
Introduction to Spectrophotometry
Estimation of analyte concentration on the basis of light absorption
Introduction to Spectrophotometry
Spectroscopy Chem honors.
Analysis of Iron Experiments 3, 19 & 20.
Quantitative tests for proteins
Practical clinical chemistry
Analytical Method Validation
Chapter 5 Quality Assurance and Calibration Methods
Choice of Methods and Instruments
Light and Matter Main Concept:
Quantitative tests for proteins
SwethaBhavani N, HimaBindu S, Venkateswara Rao A, Panikumar D Anumolu
Lab# 1 Scanning spectrophotometry and spectrophotometric determination of concentration BCH 333 [practical]
Biopharmaceutics and pharmacokinetics
Beer's- Lambert Law and Standard Curves of concentrations
ANALYTICAL METHOD VALIDATION
Quantitative tests for proteins
Quantitative tests for proteins
Colourimetry The absorption of light by a coloured solution is directly related to the concentration of the solution. Colourimetry determines the concentration.
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Presentation transcript:

WELCOME

UV Spectrophotometric Method Development And Estimation of Bicalutamide in Pharmaceutical Dosage Form

Contents Introduction Aim & Objective Drug Profile Experimental Methods Validation Result & Discussion Conclusion

Introduction Q uality Control (QC) is a system of routine technical activities, to measure, ensure and control the quality in a product or service. The basic goal of quality control is to ensure that the products, services or processes provided meet specific requirements and are dependable, satisfactory and physically sound. Quality Control is the implementation of regular test procedures to satisfy consumer needs and to prevent drugs of lesser than claimed therapeutic value from entering into the market. the analytical studies are important to find out the exact amount of active pharmaceutical ingredients present in the dosage form.

Analytical methods are developed according to ICH guidelines Quality assurance is the process of verifying or determining whether products or services meet or exceed customer expectations. Quality assurance is a process-driven approach with specific steps to help define and attain goals. This process considers design, development, production and service. Quality assurance demonstrates that the drug is 'FIT FOR USE' and can satisfy its consumers by lessening its defects and improving its usability and performance. Analytical methods are developed according to ICH guidelines Quality assurance is the process of verifying or determining whether products or services meet or exceed customer expectations. Quality assurance is a process-driven approach with specific steps to help define and attain goals. This process considers design, development, production and service. Quality assurance demonstrates that the drug is 'FIT FOR USE' and can satisfy its consumers by lessening its defects and improving its usability and performance.

Aim & Objective The aim of our project is to develop UV Spectrophotometric method of Bicalutamide Under this method our objective is to 1.find λmax 2.Find calibration curve 3.Validation & 4.Quantification Through this project, an attempt is being made to develop and validate simple, sensitive methods which include spectrophotometry for quantitative monitoring of Bicalutamide in pure as well as pharmaceutical dosage forms.

Drug Profile Bicalutamide is in a class of medications called nonsteroidal antiandrogens which works by blocking the effect of androgen (a male hormone), to stop the growth and spread of cancer (Prostate Cancer ). Bicalutamide is a racemate and the (R)-enantiomer is primarily responsible for its anti-androgenic activity.

Molecular mass : g/mol Pka : Approx 12 Solubility : Practically insoluble in water, slightly soluble in chloroform, and absolute ethanol, sparingly soluble in methanol, and soluble in acetone and tetrahydrofuran. Bioavailability :well absorbed Routes :Oral

Methodology UV SPECTROPHOTOMETRIC METHOD Many molecules absorb ultraviolet light.Absorption methods based on ultraviolet (UV) radiation( nm) find wide spread application for the identification and determination of organic and inorganic species. Absorbance is directly proportional to the path length, b, and the concentration, c, of the absorbing species. Beer's Law states that A = abc, where a is a constant of proportionality, called the absorptivity By plotting absorbance, A, against concentration, a straight line will be obtained. This calibration line may then be used to determine unknown concentration of solutions of the same material after measurement of absorbance

The choice of solvent is governed by the solubility of the absorbing substance and by the absorption of the solvent at the given wavelengthThe choice of solvent is governed by the solubility of the absorbing substance and by the absorption of the solvent at the given wavelength The absorption of UV radiation corresponds to the excitation of outer electrons which involves transitions of π,σ and n electrons. σ to σ* Transitions : Requires high energy and shorter wavelength π to π* Transitions :Requires low energy and longer wavelength

Experimental Methods Instrument SYSTRONICS UV-VIS Double Beam Spectrophotometer 2201 Methodology Adopted Preparation of standard solution study of spectral characteristics of Bicalutamide R.S in THF Calibration curve of Bicalutamide R.S in THF by UV absorption method Development of an analytical method using this calibration plot Comparative study of commercially available dosage form with Bicalutamide R.S Statistical evaluation of the calibration plot stability profile Validation of the method

Spectral characteristics of Bicalutamide R.S Multiple wavelength analysis of Bicalutamide R.S from nm, shows maximum absorption at 276nm. ie. Λmax = 276nm

Calibration curve of Bicalutamide Prepared 10 sets of dilutions. Wavelength at 276nm was fixed. Absorbance were found by using single wavelength analysis. Calibration curve was plotted by taking Absorbance Vs Concentration

Sl No.Concentration of Bicalutamide ug/ml Absorbance at 276nm

The data reveals that Beer's law is obeyed between concentration range of 5-30 ug/ml. Above 45 ug/ml the absorbance value was found to be very high

Y = X Correlation coefficient =0.999 Correlation coefficient =0.999 standard deviation = standard error was

Validation of the proposed method Accuracy Repeatability LOD and LOQ Linearity Range

Accuracy It expresses the closeness of agreement between reference value and value found. Accuracy was evaluated by carrying out a recovery study. And the method was found to be accurate.

Repeatability Repeatability expresses the precision under same operating conditions over a short interval of time. It is usually expressed as the closeness of agreement between a series of measurements obtained. It is usually expressed as the standard deviation, variance, or relative standard deviation of a series of measurements.

LOD and LOQ The limit of detection (LOD) is defined as the lowest concentration of an analyte that can be detected. But not necessarily quantified as an exact value. LOD = 3s/m And was found to be 2µg/ml.

The limit of quantification (LOQ) is defined as the lowest concentration of the standard curve that can be measured with an acceptable accuracy, precision, and variability. LOQ = 10s/m And was found to be 7µg/ml

Linearity The linearity of an analytical procedure is its ability to obtain test results, which are directly proportional to the concentration of the analyte in the sample. The calibration curve of Bicalutamide by the proposed method was found to be linear over the range of 5-30 µg/ml