Luminosity and beam calorimeter report E. Kouznetsova, DESY.

Slides:



Advertisements
Similar presentations
Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba October 07 Malá Skála.
Advertisements

March, 11, 2006 LCWS06, Bangalore, India Very Forward Calorimeters readout and machine interface Wojciech Wierba Institute of Nuclear Physics Polish Academy.
TESLA R&D: LCAL/LAT Achim Stahl DESY Zeuthen Cracow Tel Aviv Minsk Prague Colorado Protvino UCL London Dubna.
Angular resolution of LAT Agnieszka Kowal University of Science and Technology, Cracow TESLA Workshop on Forward Calorimetry Cracow, 10 October 2003.
Experimental Aspects of Precision Luminosity Measurement contributions from Forward Calorimetry Collaboration L.Suszycki AGH University of Science and.
1 Laser alignment system Status report Leszek Zawiejski INP PAN, Cracow EUDET Annual Meeting 2008, October 6-8, Amsterdam, Holland W. Wierba, K. Oliwa,
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
August 2005Snowmass Workshop Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Karsten Büßer Beam Induced Backgrounds at TESLA for Different Mask Geometries with and w/o a 2*10 mrad Crossing Angle HH-Zeuthen-LC-Meeting Zeuthen September.
Effect of the Shape of the Beampipe on the Luminosity Measurement September 2008 Iftach Sadeh Tel Aviv University DESY.
1 LumiCal Optimization and Design Takashi Maruyama SLAC SiD Workshop, Boulder, September 18, 2008.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Krakow2006.
Ronen Ingbir Collaboration High precision design Tel Aviv University HEP Experimental Group Cambridge ILC software tools meeting.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
Karsten Büßer Beam Induced Backgrounds at TESLA for Different Mask Geometries with and w/o a 2*10 mrad Crossing Angle LCWS 2004 Paris April 19 th 2004.
Analysis of Beamstrahlung Pairs ECFA Workshop Vienna, November 14-17, 2005 Christian Grah.
Calorimeter technologies for forward region instrumentation K. Afanaciev 2, R. Dollan 1 V. Drugakov 2, C. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
March 2004LCWS Stanford Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Instrumentation of the very forward region of the TESLA detector – summary of the Workshop on Forward Calorimetry and Luminosity Measurement, Zeuthen,
Simulation of physics background for luminosity calorimeter M.Pandurović I. Božović-Jelisavčić “Vinča“ Institute of Nuclear Sciences, Belgrade, SCG.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
2. December 2005Valencia Workshop Very Forward Region Instrumentation Wolfgang Lohmann, DESY Basic functions: - Hermeticity to small polar angles - Fast.
Ivan Smiljanić Vinča Institute of Nuclear Sciences, Belgrade, Serbia Energy resolution and scale requirements for luminosity measurement.
July 2006ALCWS Vancouver Very Forward Instrumentation of the Linear Collider Detector On behalf of the Wolfgang Lohmann, DESY.
September, 19 FCAL Worlshop in Tel Aviv W. Lohmann, DESY Physics Requirements Input From Theory Lessons from LEP LumiCal Simulations BeamCal.
Septembre SLAC BeamCal W. Lohmann, DESY BeamCal: ensures hermeticity of the detector to smallest polar angles -important for searches Serves as.
Karsten Büßer Instrumentation of the Forward Region of the TESLA Detector International Europhysics Conference on High Energy Physics Aachen, July 19th.
ILC-ECFA Workshop Valencia November 2006 Four-fermion processes as a background in the ILC luminosity calorimeter for the FCAL Collaboration I. Božović-Jelisavčić,
First results from silicon and diamond sensors K. Afanasiev 1, I. Emeliantchik 1, E. Kouznetsova 2, W. Lohmann 2, W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Optimization of the Design of the Forward Calorimeters ECFA LC Workshop Montpellier, 15 November 2003 *FC Collaboration: Colorado, Cracow, DESY(Zeuthen),
TESLA R&D: Forward Region Achim Stahl DESY Zeuthen Cracow Tel Aviv Minsk Prague Colorado Protvino UC London Dubna.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
A Clustering Algorithm for LumiCal Halina Abramowicz, Ronen Ingbir, Sergey Kananov, Aharon Levy, Iftach Sadeh Tel Aviv University DESY Collaboration High.
A Luminosity Detector for the Future Linear Collider Ronen Ingbir Prague Workshop HEP Tel Aviv University.
Silicon sensors for LumiCal Two possible options Wojciech Wierba Institute of Nuclear Physics PAN Cracow.
HEP Tel Aviv University LumiCal (pads design) Simulation Ronen Ingbir FCAL Simulation meeting, Zeuthen Tel Aviv University HEP experimental Group Collaboration.
Pad design present understanding Tel Aviv University HEP Experimental Group Ronen Ingbir Collaboration High precision design Tel-Aviv Sep.05 1.
1 Laser alignment system Status report Leszek Zawiejski Eryk Kielar, Krzystof Oliwa, Wojciech Wierba, INP PAN, Cracow, Poland Wojciech Slominski, Jagiellonian.
Integration with LDC & Push-pull impact on LumiCal Wojciech Wierba Institute of Nuclear Physics PAN Cracow, Poland FCAL Workshop, LAL Orsay,
1 Some results from LumiCal Monte Carlo Studies Michał Karbowiak, B. Pawlik, L. Zawiejski Michał Karbowiak (*), B. Pawlik, L. Zawiejski Institute of Nuclear.
August DESY-HH VFCAL Report W. Lohmann, DESY Infrastructure for sensor diagnostics FE Electronics Development Sensor test facilities Laser Alignment.
HEP Tel Aviv UniversityLumical - A Future Linear Collider detector Lumical R&D progress report Ronen Ingbir.
Status of Forward Calorimetry R&D: Report from the FCAL Collaboration Bruce A. Schumm Santa Cruz Institute for Particle Physics University of California,
The Luminosity Calorimeter Iftach Sadeh Tel Aviv University Desy ( On behalf of the FCAL collaboration ) June 11 th 2008.
1 LumiCal Optimization Simulations Iftach Sadeh Tel Aviv University Collaboration High precision design May 6 th 2008.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
October DESY PRC Instrumentation of the Very Forward Region of a Linear Collider Detector Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell.
Tungsten-Silicon Luminosity Detector with Flat Geometry Ronen Ingbir Tel Aviv University High Energy Physics Experimental Group.
September 2007SLAC IR WS Very Forward Instrumentation of the ILC Detector Wolfgang Lohmann, DESY Talks by M. Morse, W. Wierba, myself.
LumiCal background and systematics at CLIC energy I. Smiljanić, Vinča Institute of Nuclear Sciences.
1 LoI FCAL Takashi Maruyama SLAC SiD Workshop, SLAC, March 2-4, 2009 Contributors: SLAC M. BreidenbachFNALW. Cooper G. Haller K. Krempetz T. MarkiewiczBNLW.
HEP Tel Aviv University Lumical R&D progress report Ronen Ingbir ECFA - Durham2004 Lumical - A Future Linear Collider detector.
November, 7, 2006 ECFA06, Valencia, Spain LumiCal & BeamCal readout and DAQ for the Very Forward Region Wojciech Wierba Institute of Nuclear Physics Polish.
FCAL Krakow meeting, 6. May LumiCal concept including the tracker R. Ingbir, P.Růžička, V. Vrba.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
Very Forward Instrumentation: BeamCal Ch. Grah FCAL Collaboration ILD Workshop, Zeuthen Tuesday 15/01/2008.
LumiCal High density compact calorimeter at the ILC Wojciech Wierba Institute of Nuclear Physics PAS Cracow, Poland.
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
FCAL R&D towards a prototype of very compact calorimeter
Luminosity Measurement using BHABHA events
Summary of the FCAL Workshop Cracow, February 12-13
LumiCal mechanical design, integration with LDC and laser alignment
Wolfgang Lohmann DESY (Zeuthen)
LAT performance studies
Luminosity and beam calorimeter report E. Kouznetsova, DESY
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
Presentation transcript:

Luminosity and beam calorimeter report E. Kouznetsova, DESY

2 LAT calorimeter options L.Suszycki, Cracow Forward Calorimetry WG, Amsterdam, 31 March 2003

3 LAT luminosity measurement Essential for precise luminosity measurement is a precise angle measurement of the Bhabha scattered electrons.  L/L = needs  min = 1.4  rad The standard (TDR) setup enables only 0.2 – 0.3 mrad accuracy with the price of channels. We try The standard setup improvements and to consider alternative geometry setups: Flat LAT Stripped LAT L.Suszycki, CracowAmsterdam 31. March ‚03

4 Improved LAT geometry Improvements comparing to the Prague results: 1.Silicon sensors arranged in planes 2.Non-projective cylinders of equal height Angle reconstruction using All sensors :   =~0.9 mrad Every 4th sensor :   =~1.1 mrad Every 10th sensor :   =~1.5 mrad L.Suszycki, CracowAmsterdam 31. March ‚03 It is resonable to apply fine segmentation to a fraction of cylinders only

5 Leackage makes precision Lumi hard Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03

6 Flat LAT geometry All cylinders start at z=136 cm 7, 14, 18 or 56 cylinders assumed Conical projective geometry is kept (TDR) Sergey Kananov, Tel Aviv Angle reconstruction Gain in angle resolution = 2.5 at price of increasing of #channels of factor 56/14=4! L.Suszycki, CracowAmsterdam 31. March ‚03

7 Flat LAT shower maximum method Sergey Kananov, Tel Aviv Only rings near the shower maximum at ring #8 are significant for theta reconstruction: 1, 3, 5, 7, 10, 16 or 20 „active” rings One can reach better angular resolution with similar #channels: Uniform: 14 x 30 x 24 = => 0.18 mrad 5 rings 2-fold granulated: => 0.13 mrad 5 rings 4-fold granulated: => 0.09 mrad L.Suszycki, CracowAmsterdam 31. March ‚03

8 Silicon 1mm strips arranged in 20 cones to read r and z x 256 strips + 20 cones to read φ x 72 strips => 6560 channls in total Stripped LAT geometry Bogdan Pawlik, Cracow  =  gen -  rec (radians) vs. strip layer („cylinder”)  = ~0.9mrad at 9st layer L.Suszycki, CracowAmsterdam 31. March ‚03

9 LAT conclusions Preliminary results on alternative LAT geometry are obtained Much more MC work is necessary to get closer to the required acurracy of the angle measurement Still awaiting for the Flat Mask decision L.Suszycki, CracowAmsterdam 31. March ‚03

10 Challenges in Lumi Measurement Some studies of sensitivity to systematic uncertainties Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03

11 Method BHLUMI (Ver. 4.04) No Detector Simulation Generate an event  calculate coordinates on calorimeter  apply systematic shifts  recalculate coordinates  apply selection cuts  count events  Lumi E +, E - > 0.8 E beam Acol < 11.5 o 30 mrad < θ + < 75 mrad 30 mrad < θ - < 75 mrad Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03

12 Lin. Coeff. ≈ 0 Quadratic Coeff.: Δoffset < 200 μm Offset of Beams from Axis Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03

13 Inner Radius of Calorimeter : ΔL/L ≈ / μm Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03 Longitudinal Distance of Calorimeters : ΔL/L ≈ / mm z + - z - < 60 μm

14 Conclusions Beam Offsets: < 200 μm Inner Radius of Cal < 0.75 μm Distance of Cals < 60 μm Center-of-Mass Energy: process dependent To achieve ΔL / L ≈ : but that‘s not all yet Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03

LAT detector alignment Wojciech Wierba Institute of Nuclear Physics Cracow Poland Jerzy Zachorowski M. Smoluchowski Institute of Physics Jagiellonian University Photonics Group Cracow Poland Wojciech Wierba Cracow, PolandAmsterdam 31. March ‚03

16 LAT alignment The luminosity measurement requires precision alignment of the LAT detectors and stable, precision placement in reference to the interaction point. The beam pipe becomes as a suitable reference because the Beam Position Monitors are mounted inside the vacuum pipe. This allows us to correct the real LAT detectors position in respect to the beam position. There are four tasks: Measurement of the beam pipe dimensions in the lab. Radial metrology and mechanical design of the LAT detectors. Initial alignment of the LAT detectors in the forward region. On line system to measure displacement of the LAT detectors. Wojciech Wierba Cracow, PolandAmsterdam 31. March ‚03

17  The Photonic sensor for the z (along the beam) distance measurement: Small probe head, just end of the ~3mm fiber. Lightweight probe to be attached to the flange of the beam pipe. All electronics and laser can be placed outside the TESLA detector. Only fibers have to be feed near the LAT detector. Continuous laser beam is not necessary i.e. power fault, laser change/repair. On line system to measure displacement of the LAT detectors Wojciech Wierba Cracow, PolandAmsterdam 31. March ‚03

18 On line system to measure displacement of the LAT detectors Wojciech Wierba Cracow, PolandAmsterdam 31. March ‚03  Fine pixel CCD sensor to measure x, y and  position : The CCD detector should be glued to the rear face of the calorimeter. The laser beam can be distributed via optical fiber. The laser spot will be formed by collimator or optics. Advantages : Small and lightweight collimator/optics to be attached to the flange of the beam pipe. Laser can be placed outside the TESLA detector. Continuous laser beam is not necessary i.e. power fault, laser change/repair. Only some cables and fiber have to be feed near the LAT detector. Problems : Radiation hardness of the CCD sensor and electronics. The CCD will be placed between rear side of the LAT calorimeter and tungsten shield and probably the radiation dose will be not so high. Background from the particles. The position measurement can be done in the time slot between trains when beams are not present. The speed of the CCD sensor is sufficient to do that.

First results from silicon and diamond sensors K. Afanasiev 1, I. Emeliantchik 1, E. Kouznetsova 2, W. Lohmann 2, W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen

20 Test Set Up E. Kouznetsova DESY ZeuthenAmsterdam 31. March ‚03 discr delay in gate ADC PA diamond Sr or

21 Signals from 90 Sr – silicon and diamond : Si (mip) Diamond (noise) Diamond (whole  - spectra) Diamond E. Kouznetsova DESY ZeuthenAmsterdam 31. March ‚03

22 Noise level is not optimal for signal/noise separation (ENC ≈700 e) Possible solutions : Noise optimization of the existing preamplifier Switch to Amptek A250 (noise expected ≤ 350 e) New trigger scintillator matching the size of the sensor New diamond samples : Fraunhofer Institute (Freiburg) : (12 x 12 mm) 300 and 200  m Different surface treatments Prokhorov Institute (Moscow) - Dubna group Problems and further steps : E. Kouznetsova DESY ZeuthenAmsterdam 31. March ‚03

23 New Design of the Mask  For L* = 3 m performance of the mask calorimeters is doubtful  For larger L* things look easier  Question: How much L* do we need? Achim Stahl DESY Zeuthen

24 Leackage makes precision Lumi hard Fake Photons Too close to beamstrahlung Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03

25 Advantages  Luminosity: More likely to achieve 0.01 %  No fakes can scatter from mask into ECal  Vacuum much better, large orfice, bellow, valve  Space for electronics available  Better separation of outer Cal from beamstrahlung (5cm -> 8cm)  Hermetic to 3.9 mrad (was 5.5 with gaps)  Shintake monitor taken into account L* approx. 4 meters Achim Stahl DESY ZeuthenAmsterdam 31. March ‚03