1. Voltammetry AIT.

Slides:



Advertisements
Similar presentations
A galvanic cell is made from two half cells. In the first, a platinum electrode is immersed in a solution at pH = 2.00 that is M in both MnO 4 -
Advertisements

Electricity from Chemical Reactions
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
ELECTRICITY & CHEMISTRY
Lecture 6a Cyclic Voltammetry.
Chem. 133 – 2/19 Lecture. Announcements Lab Work –Turn in Electronics Lab –Starting Set 2 HW1.2 Due Today Quiz 2 Today Today’s Lecture –Noise –Electrochemistry.
Geiger-Muller detector and Ionization chamber
Introduction to Electroanalytical Chemistry
Lecture 15 CM1001.
Unit 2 B Voltammetry and Polarography
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Yat Li Department of Chemistry & Biochemistry University of California, Santa Cruz CHEM 146C_Experiment #8 Surface Electrochemistry: Adsorption of Polyoxometalate.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Polarography.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Voltammetry Nov 16, 2004 Lecture Date: March 27th, 2006.
INTRODUCTION TO ELECTROCHEMICAL CELLS AND BASIC ELECTROANALYTICAL MEASUREMENTS ANDREA MARDEGAN JAN 17th 2013.
Lecture 14 CM1001. Oxidation Numbers Positive or negative numbers decided using agreed rules. Help us work out whether a substance is oxidized or reduced.
Electroanalytical Chemistry
Voltaic Cells Chapter 20.
Lesson 2. Galvanic Cells In the reaction between Zn and CuSO 4, the zinc is oxidized by copper (II) ions. Zn 0 (s) + Cu 2+ (aq) + SO 4 2-  Cu 0 (s) +
Chapter 17 Electrochemistry 1. Voltaic Cells In spontaneous reduction-oxidation reactions, electrons are transferred and energy is released. The energy.
ELECTROCHEMISTRY CHEM 4700 CHAPTER 3
16-1 Voltammetry Electrochemistry techniques based on current (i) measurement as function of voltage (E appl ) Working electrode §(microelectrode) place.
Other Electrochemical Methods
Voltammetry: A Look at Theory and Application Bobby Diltz 14 March 2005.
Electrochemistry Introduction
CHAPTER 12 ELECTRODE POTENTIALS AND THEIR APPLICATIONS TO XIDATION/REDUCTION TITRATIONS Introduction to Analytical Chemistry.
6/2/20161 CHAPTER 2 CORROSION PRINCIPLES Chapter Outlines 2.1 Oxidation and Reduction Reactions 2.2 Standard Electrode Half- Cell Potentials 2.3 Standard.
Chapter 26 – Electricity from Chemical Reactions.
polaro- and voltamanalytical methods
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Chapter 5 – Analysing Oxidants & Reductants Week 3, Lesson 1.
Electricity from chemical reactions Galvanic Cells Chapter 14.
14 Redox Equilibria 14.1 Redox Equations (Review) 14.2 Electrode Potentials and the Electrochemical Series 14.3 Predicting the Direction of Redox Reactions.
Voltammetry 伏安分析法.
Chapter 16.  the chemical principles, half-equations and overall equations of simple electrolytic cells; comparison of electrolytic cells using molten.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Electrochemistry The Study of the Interchange of Chemical and Electrical Energy.
Chem. 133 – 3/3 Lecture. Announcements Homework Set 2 (pass out) Grading –Working to get the Electronics labs and exam 1 graded by next Tuesday Lab –today.
Ch. 21 Potentiometry 1. General principles
In the name of GOD.
Dr. Rasha Hanafi Lecture 8 Non- potentiometric methods of analysis: Amperometry and Voltammetry (Polarography) Dr. Rasha Hanafi Dr. Rasha Hanafi, GUC.
Bulk Electrolysis: Electrogravimetry and Coulometry
Instrumental Analysis Polarography and Voltammetry
Home Reading Skoog et al. Fundamentals of Analytical Chemistry. Sections 18A, 18C ( in chapter 18 ), Chapter 23.
Cd(s) ↔ Cd2+ + 2e- depends on [Cd2+]s and not [Cd2+]o
Electrochemistry. three principal sources for the analytical signal potential, current, charge a wide variety of experimental designs are possible.
Introduction to Electroanalytical Chemistry
ELECTROCHEMISTRY Voltaic and Electrolytic Cells
CH5715 Energy Conversion and Storage
Stripping Methods of Analysis
Voltammetry and Polarography
Ion Selective Electrode
Lecture 7a Cyclic Voltammetry.
Electrochemistry: Introduction Electrochemistry at your finger tips
Polarography and Voltammetry
Voltammetry and Polarography
Dnyanasadhana College, Thane.
Dnyanasadhana College, Thane.
Amperometric Titrations By
Chapter Fifteen VOLTAMMETRY AND ELECTROCHEMICAL SENSORS
Electrochemistry Lesson 3
Chapter 5 – Analysing Oxidants & Reductants
C. Some factors are: 1. pH 2. Temperature
S.M.Joshi College, Hadapsar, Pune
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Presentation transcript:

1. Voltammetry AIT

Basics a redox reaction transfers electrons between the reactant species and the electrode produces a measurable current the greater concentration of reactive species, the greater the current measurement of currents can be used to determine concentrations voltammetry - an electrical current is measured as a function of applied potential used to identify and quantify

M+ + e  M (s) reaction will only occur if both the following conditions apply: the ion is close enough to the electrode the voltage applied at the electrode is enough to allow the reaction to occur (the reduction potential) some ions will always be close to the electrode by sheer chance voltage as the controlling factor for whether reaction will occur

Applied potential Reduction potential Initial potential Too low, so no reaction can occur Current is zero As potential approaches redn V, some ions react Current is low and increasing Current As potential pass redn V, all ions near electrode react Current is high After redn V, ions newly arrived near electrode react Current is high and constant

a measurable change in current as a consequence of a voltage change this is known as a wave whole scan is a voltammogram

Exercise 1.1 an analogy between spectroscopy and voltammetry peak wave wavelength/frequency voltage intensity current

Uses of voltammetry for both quantitative and qualitative analysis: the wave position (voltage) is characteristic of a particular species the wave height (current) is proportional to concentration

Movement of ions diffusion (simple random motion), electrostatic attraction, and convection current-concentration only linear, if diffusion is the only mechanism minimise the other two processes as much as possible

Removing problems not stirring the solution controls convection not possible to prevent electrostatic attraction between the positive ions and the negative electrode reduced by addition of a high concentration of non-reactive ions, known as the supporting electrolyte KCl or KNO3 at concentrations around 0.1 M the very high level of other ions masks attraction to the electrode

diffusion electrostatic attraction

supporting electrolyte has two other functions: masks matrix interference due to different levels of background ions in different samples ensures that the solution will have enough electrical conductivity voltammetry only ever uses up a tiny fraction of the reducible species in the sample multiple scans can be run on the one sample without changing its overall concentration

1.2 Polarography the most commonly used form of voltammetry one of the electrodes is made from a capillary of mercury, forming a drop at the end known as a dropping mercury electrode (DME) scan is called a polarogram

Polarogram

Exercise 1.2 Measure the half-wave potential and diffusion current Applied potential: each scale division is equal to 0.5 V, becoming more negative from 0 V Current: each scale division is equal to 1 uA starting from 0. (a) -1.1 V (b) 7.5 uA

Polarographic cell Hg reservoir DME auxiliary electrode N2 bubbler auxiliary electrode DME reference electrode

Cell components Dropping mercury electrode – the electrode at which the analyte reaction occurs Reference electrode –an electrode which maintains a constant voltage regardless of the solution and reactions occurring Auxiliary electrode – provides a path through which current can flow and be measured; usually a platinum wire Nitrogen bubbler – dissolved oxygen produces two visible polarographic waves, at around –0.1 and –0.9 V bubbling nitrogen through the solution for 5 minutes removes the oxygen

Why 3 electrodes? one pair (DME & ref.) to control voltage one pair (DME & aux.) for current path and measurement Auxiliary DME Reference Current Voltage

Why a DME? does not seem like the most obvious choice one significant advantage: it presents a fresh surface to the solution every second or so allows a much more reproducible control of potential than a fixed electrode, where the reduced metal (for example) becomes coated to it Hg oxidised >+0.4 V, so a Pt or graphite working electrode must be used

Matrix effects presence of complexing agents (ligands) shifts E½ working voltage range of +0.4 to –1.8V >+0.4: the mercury drop will be oxidised < –1.8V (varies with pH) water is reduced to hydrogen gas

Improvements to polarography limited sensitivity – DC polarography is limited to about 5 mg/L for most species difficulty in measurement – due to the waveform shape and the oscillations improve the former and get rid of the latter by changing the way that: the voltage changes the current is measured

1. Sampled DC most obvious problem is the oscillations “digitise” the current measurement, so that a single measure per drop was taken measurement is timed at just before the drop falls off (knocker) slightly improved sensitivity polarogram output measurement point

2. Pulsed polarography sensitivity is limited by the relatively high level of background current it “hides” analyte response three causes: other species – apart from oxygen, not solvable voltage changes – the drop charges like a capacitor as the V changes drop growth – high bkgd current at start of drop growth

Solutions V changes – apply V increases in steps (pulses), since capacitor behaviour fades if V is constant drop growth – measure at end of drop life: bkgd current has faded away 10 x improvement in sensitivity time V continuous voltage change pulsed change

3. Differential pulse pulse still gives difficult to measure wave DP measures at two points (start and end of drop) current plotted is difference 20 x increase in sensitivity change of shape to peak (like 1st derivative titration curve)

Advantages sensitivity – realistic detection limits for differential pulse polarography are around 50 ug/L, multi-component analysis – provided the half-wave potentials are at least 100 mV apart, equipment that is relatively simple and not particularly expensive – typically $40,000 for a computer-controlled device capable of polarography and voltammetry, a wide range of analytes - metallic ions, non-metallic ions and organic species.

Disadvantages contaminated mercury – which can be purified by distillation with special apparatus, relatively slow – due to purging time matrix interference – due to complex formation, which can make a species not analysable because the half-wave potential is outside the measurable range

DO electrode an electrode which measures dissolved oxygen (DO) not an ion-selective electrode relies on current, not potential, measurement the oxygen is not an interference but the analyte non- scanning: V held at -0.8V current is proportional to the oxygen concentration calibrated using a saturated solution (9 mg/L at 25C)

Anodic stripping voltammetry the most sensitive form analyses much more of the sample than normal polarography requires stirring & longer reaction period cannot do a very slow scan Hg drop electrode still used Step 1 (slow) - fixed voltage, with stirring for 90s to 10 minutes M+ + e => M (Hg amalgam) Step 2 (normal speed) – scan M(Hg amalgam) => M+ + e

ASV not all analyte is reduced – time dependent can measure at ng/L (not ug/L) level limited to those which form an amalgam with Hg copper, lead, cadmium, zinc, indium and bismuth

Exercise 1.4 What is the problem with using a DME for this analysis? reduced analyte in step 1 falls to the bottom of the cell and is lost What could be done to get around this problem, still using a mercury drop as the electrode? both steps are done with a single drop called Hanging Drop Mercury Electrode (HDME)