Joachim Schultes University of Wuppertal FIT Wiener DCS Training Session 2.1.

Slides:



Advertisements
Similar presentations
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Advertisements

QUICK GUIDE MANUAL GV-DVR System Organization 2. Specification.
CPV DCS STATUS REPORT Mikhail Bogolyubsky (IHEP, Protvino) Serguei Sadovsky (IHEP, Protvino) CERN, DCS meeting, 30 January, 2007.
Virtual LANs.
1 Dynamic DNS. 2 Module - Dynamic DNS ♦ Overview The domain names and IP addresses of hosts and the devices may change for many reasons. This module focuses.
CCNA2 Module 4. Discovering and Connecting to Neighbors Enable and disable CDP Use the show cdp neighbors command Determine which neighboring devices.
Joachim Schultes University of Wuppertal Interlock System DCS Training Session 2.3.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
MCDST : Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Chapter 13: Troubleshoot TCP/IP.
HV for SM surface testing 2 nd Workshop on the Detector Control System for TRD University of Tsukuba Kengo Watanabe.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 11: Monitoring Server Performance.
9.1 © 2004 Pearson Education, Inc. Exam Managing and Maintaining a Microsoft® Windows® Server 2003 Environment Lesson 9: Installing and Configuring.
IT:Network:Applications VIRTUAL DESKTOP INFRASTRUCTURE.
Internet Technologies Networking / Internet Protocols (TCP/IP) Server/Client Software Communication via Ports Web Page Technology Recipe of Web Page Development.
Copyright © Anviz Global Inc. USA Anviz Online Training Lesson 11 : Anviz product remote access Anviz International Technical Support Team.
Printer Installation Ben Wu A&S IT 09/18/2007. Outline  Preparation  Local Printer Installation  Network Printer Installation  Printer Sharing  Other.
R. Lange, M. Giacchini: Monitoring a Control System Using Nagios Monitoring a Control System Using Nagios Ralph Lange, BESSY – Mauro Giacchini, LNL.
RADIUS Server (Brocade Controller)
Basic Router Configuration Honolulu Community College Cisco Academy Training Center Semester 2 Version 2.1.
GeoVision Solutions Storage Management & Backup. ๏ RAID - Redundant Array of Independent (or Inexpensive) Disks ๏ Combines multiple disk drives into a.
Calo Piquet Training Session - Xvc1 ECS Overview Piquet Training Session Cuvée 2012 Xavier Vilasis.
ECS for Front-End crates MARATON. 2 Introduction Front-End crates are powered by MARATON power supplies, located on the platform, at the back of each.
Home Media Network Hard Drive Training for Update to 2.0 By Erik Collett Revised for Firmware Update.
Towards a Detector Control System for the ATLAS Pixeldetector Susanne Kersten, University of Wuppertal Pixel2002, Carmel September 2002 Overview of the.
SMACS Slow Monitor And Control System Developed system for CDF-TOF proposed for Atlas-MDT/RPC.
1 Chapter Overview Installing the TCP/IP Protocols Configuring TCP/IP.
1 Chapter Overview Using the New Connection Wizard to configure network and Internet connections Using the New Connection Wizard to configure outbound.
Configuring Network Connectivity Lesson 7. Skills Matrix Technology SkillObjective DomainObjective # Using the Network and Sharing Center Use the Network.
Network Management Tool Amy Auburger. 2 Product Overview Made by Ipswitch Affordable alternative to expensive & complicated Network Management Systems.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 11: Monitoring Server Performance.
Cisco S2 C4 Router Components. Configure a Router You can configure a router from –from the console terminal (a computer connected to the router –through.
Windows Small Business Server 2003 Setting up and Connecting David Overton Partner Technical Specialist.
LKr Calorimeter Control and monitoring R. Fantechi 19/02/2010 R. Fantechi.
XXVI Workshop on Recent Developments in High Energy Physics and Cosmology Theodoros Argyropoulos NTUA DCS group Ancient Olympia 2008 ATLAS Cathode Strip.
QuikTrac 5.5, a validated Motorola Software Solution, allows you to take your Host ERP screens and extend them out to fixed or mobile devices including.
Programming Software and Setting. if forget the IP address of SB-DN-1IP, programmer can press the reset button till the led goes red, then it is reset.
Module 5: Implementing Printing. Overview Introduction to Printing in the Windows Server 2003 Family Installing and Sharing Printers Managing Access to.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 11: Monitoring Server Performance.
1 ECS CALO HV Control CALO Piquet Training Session Anatoli Konoplyannikov /ITEP/ Outline  ECS HV control of the ECAL/HCAL sub-detectors.  Introduction.
1 Installation Training Everything you need to know to get up and running.
October 9th 2006ALICE WEEK - DCS WorkShop1 DEVICE USER SUPPORT OVERVIEW - Presentation - First Line Support - Reference System - Current Developpement.
19/05/10FV 1 HyTec crate – DCS integration issues.
GPRS functionality overview in Horner OCS. GPRS functionality – Peer to Peer communication over GPRS – CSCAPE connectivity over GPRS – Data exchange using.
Chamber Monitor Panel Emiliano Furfaro 16 october 2012.
Alice MTR DCS F.Jouve 15 th DCS workshop CERN 13/03/2006 UX-A,B,D Detector PVSS II Detector Ethernet Database(s) OPC client DIM client 1672 Detector ?
XXVI workshop on resent developments in High Energy Physics and Cosmology Ancient Olympia,16-19 April 2008 Tsarouchas Charilaos NTUA Detector Control System.
Source Controller software Ianos Schmidt The University of Iowa.
Alice DCS workshop S.Popescu ISEG Crate controller + HV modules ISEG HV modules 12 Can bus PVSS OPC Client 1 Generic OPC Client Iseg OPC.
A guide to file sharing on Windows XP Peer to Peer File Sharing.
60kW Thermosiphon control system
5th March 0718th DCS Workshop1 News on ISEG & WIENER Lionel Wallet, CERN High Voltage, Low Voltage & VME Crate control.
Programming Software and Setting. Default IP Add : , also can be changed via Programming Software, if forget IP address, Programmer can.
1 ECS CALO HV Control CALO Piquet Training Session Anatoli Konoplyannikov /ITEP/ Outline  ECS HV control of the ECAL/HCAL sub-detectors.  Introduction.
S.Sergeev (JINR). Tracker consists of  4 stations of 4 views (planes) each In total ~7200 drift tubes (~450 per view) To be controlled/monitored 
T0 DCS Status DCS Workshop March 2006 T.Karavicheva on behalf of T0 team.
E Ethernet C CAN bus P Profibus HV HV cables LV LV cables (+busbar) S Serial (RS232) Signal cable Other/Unknown Liquid or Gas Cable and/or Bus PCI-XYZ.
1 LHCb CALO Anatoli Konoplyannikov Introduction Short recipe of the calorimeter Marathon crates control Step by step explanation Marathon power.
Chapter 5. An IP address is simply a series of binary bits (ones and zeros). How many binary bits are used? 32.
1 Top Level of CSC DCS UI 2nd PRIORITY ERRORS 3rd PRIORITY ERRORS LV Primary - MaratonsHV Primary 1 st PRIORITY ERRORS CSC_COOLING CSC_GAS CSC – Any Single.
Joachim Schultes University of Wuppertal FIT Iseg DCS Training Session 2.2.
20OCT2009Calo Piquet Training Session - Xvc1 ECS Overview Piquet Training Session Cuvée 2009 Xavier Vilasis.
Windows Vista Configuration MCTS : Advanced Networking.
The Maraton LV system Michela Lenzi INFN Firenze Thanks to V. Bocci, P. Ciambrone, A. Sciubba LV Power Supply RCM AC/DC converter.
UC Pro Troubleshooting Guide
Wireless 4 Buttons Touch Panel
G.Thomas & D.Davids (CERN) & O.Holme (ETH Zurich)
Radiation- and Magnet field- Tolerant Power Supply System
Radoslaw Jedynak, PhD Poland, Technical University of Radom
Gurpreet Singh CSE/IT.
Presentation transcript:

Joachim Schultes University of Wuppertal FIT Wiener DCS Training Session 2.1

DCS Training 2007: FIT WienerJoachim Schultes Overview Hardware Crates Wiener PL 512Crates Wiener PL 512 ConnectivityConnectivitySoftware Muhse (communication via USB)Muhse (communication via USB) OPC (communication via TCP/IP)OPC (communication via TCP/IP) FIT WienerFIT Wiener IntegrationIntegration ControlControl WatchdogWatchdog

DCS Training 2007: FIT WienerJoachim Schultes Crates Wiener PL 512 Two power supply crates are mounted in between two LV_PP4 in a common frameTwo power supply crates are mounted in between two LV_PP4 in a common frame Each power supply crate consists of 12 Channel with outputs on the back, cables are fixed on the frames (crates are easy to exchange)Each power supply crate consists of 12 Channel with outputs on the back, cables are fixed on the frames (crates are easy to exchange) Communication is realized via two ports on the front panelCommunication is realized via two ports on the front panel USB (MUHSE) for configuration and debuggingUSB (MUHSE) for configuration and debugging TCP/IP (OPC) for operationTCP/IP (OPC) for operation TCP/IPUSB LV for the modules VDD and VDDALV for the modules VDD and VDDA max 12 V / 15 Amax 12 V / 15 A floatingfloating protections:protections: over-voltageover-voltage over-currentover-current

DCS Training 2007: FIT WienerJoachim Schultes MUHSE Communication via USBCommunication via USB Low level tool for configuration and debugging (operating) of Wiener cratesLow level tool for configuration and debugging (operating) of Wiener crates TCP/IP address (be aware of possibly different subnets for US and USA side)TCP/IP address (be aware of possibly different subnets for US and USA side) Interlock behaviour Maximum valuesMaximum values Parallel operation with OPC server possibleParallel operation with OPC server possible

DCS Training 2007: FIT WienerJoachim Schultes OPC server and User Interface OPC Server Communication via TCP/IPCommunication via TCP/IP Configuration managed by.XML files created by FIT WienerConfiguration managed by.XML files created by FIT Wiener NamespaceNamespace DevicesDevices User Interface Shortcut on desktop (preferred)Shortcut on desktop (preferred) Additional manager inside the PVSS consoleAdditional manager inside the PVSS console

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener integration: access control FIT Wiener uses access control (see manual)FIT Wiener uses access control (see manual) Reason for disabled buttonsReason for disabled buttons

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener integration: managing crates “add crates”“add crates” Crate name has to be uniqueCrate name has to be unique TCP/IP address as defined inside MUHSETCP/IP address as defined inside MUHSE “OPC setup”“OPC setup” Creation of OPC configuration fileCreation of OPC configuration file “connect to OPC”“connect to OPC” definition of OPC communication (PVSS OPC client  OPC serverdefinition of OPC communication (PVSS OPC client  OPC server Modifications to entries (select device with click)Modifications to entries (select device with click) “change IP(s)”“change IP(s)” “delete crate(s)”“delete crate(s)”

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener control: selecting device Select crate with click and open control panel with right click or double clickSelect crate with click and open control panel with right click or double click Status of crate can beStatus of crate can be “OFF”, “ON”, “unknown”“OFF”, “ON”, “unknown”

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener control: crate control panel Displays main information of the 12 channelsDisplays main information of the 12 channels Channel groups are tagged by blue numbers (right click operates on groups)Channel groups are tagged by blue numbers (right click operates on groups) Status of channel can beStatus of channel can be “OFF”, “ON”, “?” (unknown)“OFF”, “ON”, “?” (unknown) “Inhibit” corresponds to an hardware interlock“Inhibit” corresponds to an hardware interlock Black value corresponds to a bad valueBlack value corresponds to a bad value

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener control: channel control panel “group settings”: assign a group number to a channel“group settings”: assign a group number to a channel “alerts”: five different reasons for an alert can be distinguished“alerts”: five different reasons for an alert can be distinguished “supervision”: specifies the behavior of the channel / group or even crate under 6 different detectable error conditions“supervision”: specifies the behavior of the channel / group or even crate under 6 different detectable error conditions Be especially careful with the “ignore the failure” option!

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener watchdog: all OK Separate process monitoringSeparate process monitoring Wiener Control Manager (self monitoring)Wiener Control Manager (self monitoring) Wiener OPC DA Client, sends and receives data from and to the OPC server and communicates them to PVSS.Wiener OPC DA Client, sends and receives data from and to the OPC server and communicates them to PVSS. Wiener OPCS, which is the OPC server communicating with the crates.Wiener OPCS, which is the OPC server communicating with the crates. Wiener crates themselvesWiener crates themselves Monitoring of devices can be disabledMonitoring of devices can be disabled

DCS Training 2007: FIT WienerJoachim Schultes FIT Wiener watchdog: pending alert OPC client not running (OPC server status unknown)  start OPC client (-num 14)OPC client not running (OPC server status unknown)  start OPC client (-num 14) OPC server not running (OPC client running)  check configuration file, start OPC serverOPC server not running (OPC client running)  check configuration file, start OPC server Device not responding (status unknown)  check connections and power  ping to IP  check IPDevice not responding (status unknown)  check connections and power  ping to IP  check IP