1 Dr. Friedhelm Schneider Overview on Grimm Aerosol Spectrometer for IAQ Part 1 Part 1 Motivation (dust, health, regulations, …) Principle function (optical.

Slides:



Advertisements
Similar presentations
SPOTLIGHT ON THE LELAND LEGACY ® PUMP FROM THE LELAND LEGACY PUMP Provides answers to particulate sampling problems. High flow rates + 24-hr run times.
Advertisements

OhioLumex Co. RA915+ Mercury Joseph Siperstein Mercury Spill Response Workshop Lansing, Michigan.
MASS EMISSION RATES AND CHEMICAL CHARACTERIZATION OF PM 2.5 EMISSIONS FROM TWO MOTORCYCLES Deniz Karman and Colin Welburn Department of Civil and Environmental.
(IAQ). Introduction  A collective group of fine solid particles, aerosols, mist, smoke, dust, fibers and fumes are called Respirable particles  Particles.
Aerosol Optical Properties via Cavity Ring-Down Technology Virtual Impactor for Sub-micron Aerosol Particles A. A. Boľshakov, A. W. Strawa, A. G. Hallar.
Basic-08_1 Dust – definition, origin, dangers, particle distribution by Eng. Wolfgang Brunnhuber Grimm Aerosol-Technik.
12th U.S./North American MVS, Reno, Nevada, June 9-11, 2008 Effects of Sintered Metal Diesel Particulate Filter System on Diesel Aerosols and Nitric Oxides.
GRIMM Aerosol Technik Existing technologies and improvements Environmental Measurement Instruments by Eng. Wolfgang Brunnhuber.
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
Nanotechnology Health, Safety & Environment General Awareness Training.
Fundamentals of Industrial Hygiene 6 th Edition Chapter 8: Particulate Matter Compiled by Allen Sullivan, Assistant Professor, Safety and Health Management.
Nanosafety assessment methodology Kaarle Hämeri Professor in Aerosol physics University of Helsinki Finnish Institute for Occupational Health.
Soot Particle Aerosol Mass Spectrometer: Development, Validation, and Initial Application T. B. Onasch,A. Trimborn,E. C. Fortner,J. T. Jayne,G. L. Kok,L.
Department of Consumer and Employment Protection Resources Safety 1 Please read this before using presentation This presentation is based on content presented.
Industrial Ventilation - A major control measure Dr. AA, UTM.
IAQ Sampling Document a condition or state of the space –Adequate ventilation –Comfort Identify source of contamination –Leakage –Products.
Environmentally Conscious Design & Manufacturing (ME592) Date: March 29, 2000 Slide:1 Environmentally Conscious Design & Manufacturing Class 11: Air Quality.
Particle pollution is linked to adverse health effects ~350,000 premature deaths a year within the EU are related to exposure to particulate matter (PM)
VII. How might current analysis methods be enhanced or combined to obtain more information about the nature of OC, EC, and other carbon fractions in filter.
1 VACUUM ATMOSPHERES Co NEW PRODUCT ANNOUNCEMENT November 28, 2001.
Atmosphere Sciences Instrumentation Lab Organized by David Delene - November 20, 2008 Overview of Instruments – 3:00 Clifford Hall 470 Lab Demonstrations.
Detection of nanoparticles
1 Motivation Particles are generally regarded as one of the most serious indoor air quality concerns Increasing concern about ultrafine particles Very.
Triggers Targets Experimental realisation Metrological application of basic science & technology Enabling science & technology Dimensional.
MAOS (Mobile Aerosol Observing System) and the G1 Aircraft at Cape Cod Allie Marquardt Collow.
HYGIENE CONTROL IN THE BREWING INDUSTRY
Krakow Conference May 2006 From toxic emissions to health effects – case study in Krakow Overview – Overall results Jose M. Jimenez – (Project.
Occupational Exposure to Metalworking Fluids Occupational Exposure to Metalworking Fluids Presented at the Occupational Hygiene Association of Ontario.
Asbestos measurement techniques, monitoring ambient and indoor air using SEM, methods and results of a first international PT scheme.   Authors/presenter:
INDUSTRY HYGIENE MONITORING AT JB COCOA SDN BHD JB Cocoa Sdn. Bhd. Is a cocoa processing plant in the Port of Tanjung Pelepas (PTP), Johor that operated.
Simulation of European emissions impacts on particulate matter concentrations in 2010 using Models-3 Rob Lennard, Steve Griffiths and Paul Sutton (RWE.
New type of Add-on Monitor for Continuous PAH Nano Particles Surface SOOT by Hans Grimm International Sales Meeting 2008.
Classification of NYC Aerosols by X-Ray and Optical Methods By: John Sangobowale (Mount St. Michael Academy) and William Dennis ( John F. Kennedy H.S.)
Size-segregated analysis of PM10 at a tandem urban – rural site combination J. K. Gietl 1*, T. Tritscher 1,2, and O. Klemm 1 1 University of Münster, Institute.
CCN measurements at an urban location Julia Burkart University of Vienna Istitute of Aerosol Physics, Biophysics and Environmental Physics.
Measurement of total mass concentration. 1. Sampling probe - Isokinetic or sampling from still air 2. Flow rate - Rotameter or digital flowmeter 3. Filter.
Comparison of gravimetric PM data from the Harvard Impactors and Gent Stacked Unit PM 10 Samplers in Prague 2004 M. CIVIŠ 1, J. HOVORKA 1 and J. SCHWARZ.
Proposal for a Research Infrastructure for Advanced Aerosol Observations and Capacity Building in China Alfred WIEDENSOHLER Leibniz Institute for Tropospheric.
Continuous Particulate Monitoring Using Light Scatter Photometers.
Alex Cuclis Houston Advanced Research Center (HARC) Particulate Matter: What Floats in the Air?
PLANT DESIGN.
LOAC (Light Optical Aerosol Counter)
Properties of Particulate Matter Physical, Chemical and Optical Properties Size Range of Particulate Matter Mass Distribution of PM vs. Size: PM10, PM2.5.
Industrial Hygiene Indoor Particles: Technology Copyright © 2008 by DBS.
Controlled Airflow Inlets NatVent project,WP3/A3.2 Willem de Gids NatVent TNO Building and Construction Research Controlled inlets Controlled inlets Back.
Wet Stack Fine Particulate Method/CEMS Development Measurement Technology Workshop January 29, 2013.
Boundary Layer Profiling using various techniques for air quality assessments Dave DuBois Ilias Kavouras and George Nikolich Division of Atmospheric Sciences.
BAuA Nanosafety Research
The Theory of Near Light Scatter
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
Dr David Healy Professor John Sodeau Dr Stig Hellebust Dr Daniela Iacopino Professor Paul Kaye Dr Warren Stanley EPA (Ireland) for funding (STRIVE-CCRP)
A new method for first-principles calibration
EMPIR Workshop – TP Environment Matthias Richter Birte Mull
Institute for Atmospheric Science SCHOOL OF EARTH AND ENVIRONMENT UNIVERSITY OF LEEDS Tethered Soundings & Profiling Cathryn Birch Ian Brooks.
Observations at the Lampedusa supersite P. Formenti, A. G. di Sarra, and the ChArMex Lampedusa team.
Technical Analysis. 1500U Floor area 1500 cm P drawer style Floor area 2064 cm 2 LET’S FOCUS ON IT!
Tests performed on By Corporate Marketing Department - Tecniplast, Buguggiate -
Properties of Particulate Matter
Jeng K. Rongchai FETE Conference 21 July 2011.
Training Workshop on Household Air Pollution and Monitoring Paro, Bhutan Household Air Pollution Studies from Bhutan Tenzin Wangchuk Department of Environmental.
Update on USGBC LEED and Air Filtration NAFA 2008 Annual Convention San Francisco, CA September 19, 2008 by Francis (Bud) J. Offermann PE CIH Indoor.
SPOTLIGHT ON THE LELAND LEGACY® PUMP FROM
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Particle Physics and Particle Counting for IH&S and IAQ
Session 4: Air Pollution Measurements
Please read this before using presentation
In-Situ Filter Testing
FMI’S CONTRIBUTION TO THE ASCOS EXPEDITION IN 2008
Chapter 3B: INDOOR AIR QUALITY
Total Solution for Flue Gas Analyzer Series
Presentation transcript:

1 Dr. Friedhelm Schneider Overview on Grimm Aerosol Spectrometer for IAQ Part 1 Part 1 Motivation (dust, health, regulations, …) Principle function (optical light scattering) Models and specifications Part 2 Part 2 Applications Occupational Health/Research

2 Dr. Friedhelm Schneider The Hazard potential of airborne aerosols is not alone given by the total mass of the dust. A further danger proceeds from the size distribution of airborne particles. Therefore a system should be able to measure both mass and size (with high accuracy and time resolution)! Motivation: what‘s dust? PM10 Filter Lienz, Day-mean PM10: 57µg/m³ soot (0.1-1µm) raod traffic glas spheres (1.5-3µm) domestic combustion road salt (4µm) antropogenic mineral dust (3-10µm) wind erosion bacteria (app. 1.5µm) natural, wind erosion

3 Dr. Friedhelm Schneider Motivation: Effect on human health, Deposition of dust in the human lung Inhaled dust Inhalable Fraction Inhalable Fraction Fraction passing the larynx and getting into the thorax Thoracic Fraction The fine particles, entering the more than 300 Mio. alveolic bubbles Alveolic Fraction

4 Dr. Friedhelm Schneider Motivation: legal situation, outdoor and indoor (workplace, IAQ) Quelle: Fellner-et-al, Endbericht, Chemische Charakterisierung von PM10 in Graz 40µg/m³ guideline 1999/30/EG since limit value for PM10 (year): 40µg/m³ PM10 (day): 50µg/m³ (50µg/m³ allowed only for 35 days/year!) guideline for workplaces e.g. EN 481 limit values (MAK, PEL, OEL,...) mostly for 8h working time Indoor (IAQ) no limit values but recomended values only

5 Dr. Friedhelm Schneider Regulations: mass fractions PM x for environment (outdoor) PM2.5PM10

6 Dr. Friedhelm Schneider Regulations: mass fractions EN 481 for workplaces (indoor) alveolic inhalablethoracic

7 Dr. Friedhelm Schneider Regulations: mass fractions indoor and outdoor alveolic inhalablethoracicPM2.5PM10

8 Dr. Friedhelm Schneider Workplace: limit values The most important standards and rules for the workplaces are: EN 481 (inhalable, thoracic and respirable fraction) ISO 7708 (like EN 481) TRGS 900 (Technical Rules of Dangerous Materials) OSHA Standard No (Occupational Safety and Health Administration) DIN ISO 7708

9 Dr. Friedhelm Schneider Workplace: example TRGS limit valuesCAS No.material A = respirable E = inhalable gaseous ppmmg/m³ CAS-Nr. = Chemical Abstract Service Registry Number

10 Dr. Friedhelm Schneider Workplace: limit values The limit values are set up and published through: CEN (Europen Committee for Standardization) DIN (Deutsches Institut für Normung) BGIA (Occupational Institute for Industrial Safety) NIOSH (National Institute of Occupational Safety and Health) OSHA (Occupational Safety + Health Administration)

11 Dr. Friedhelm Schneider Applications: Grimm Aerosol Technik Indoor Air Monitor Instruments For all applications where particle number concentration or particle mass (according to EN 481, mass distribution or indoor vs. outdoor) is needed, with high time and size resolution and for battery powered portable use! This is the GRIMM Indoor Air Monitoring product line!

12 Dr. Friedhelm Schneider Principle: single particle light scattering, Grimm spectrometer principle

13 Dr. Friedhelm Schneider Principles of particle detection: Dual! high end spectrometry + gravimetric filter aerosol focusing in real time for particle number concentration and size distribution for gravimetric validation of particle mass Dual technology in one device! Grimm patent!

14 Dr. Friedhelm Schneider Principles of particle detection: Dual! high end spectrometry + gravimetric filter filter chamber, open with 47 mm PTFE filter particle number concentration and size distribution with high time resolution and size resolution

15 Dr. Friedhelm Schneider TSP WRAC (Wilson and Suh, 1996) Particle Size in (µm) TSP Hi-vol Mass/ log D (µg 3 /m 3 ) GRIMM AEROSOL SPECTROMETER RANGE – 31 channels Mass size distributions and size fractions PM10 PM2.5 PM1 DIFFUSIONSEDIMENTATION

16 Dr. Friedhelm Schneider specification: Grimm spectrometer with 31 size channels and integrated PFTE-filter Specifications #1.109 Particle counting up to P/l Dust range [µg/m³] 0.1…> Size Range [µm] 0.25…>32 Size channels [µm] 31 channels counts 32 channels mass (0.23)/0.25/0.28/0.3/0.35/0.4/0.45/0.5/0.58/ 0.65/0.7/0.8/1/1.3/1.6/2/2.5/3/3.5/4/5/6.5/ 7.5/8.5/10/12.5/15/17.5/20/25/30/32 µm Sample air flow rate 1.2 l/min, volume controlled Power supply battery 12VDC (up to 8h) or 110…230VAC Weight/Dimensions 2.4 kg (5.3lb) with battery / 24 x 13 x 7 cm Particle concentration in particles/litre, for all size channels or Particle mass in µg/m³, for all size channels Particle mass fractions in µg/m³, simultaneously according to EN 481 occupational (inhalable, thoracic, respirable) and environmental (PM 10, PM 2.5, PM 1 ) Data output via Windows ® software

17 Dr. Friedhelm Schneider specification: Sky-OPC with critical orifice, independent of ambient pressure Specifications #1.129 Particle counting up to P/l Dust range [µg/m³] 0.1…> Size Range [µm] 0.25…>32 Size channels [µm] 31 channels counts 32 channels mass (0.23)/0.25/0.28/0.3/0.35/0.4/0.45/0.5/0.58/ 0.65/0.7/0.8/1/1.3/1.6/2/2.5/3/3.5/4/5/6.5/ 7.5/8.5/10/12.5/15/17.5/20/25/30/32 µm Power supply 12 VDC external, only Sample air flow rate 1.2 l/min constant, with critical orifice Weight/Dimensions kg / 25.5 x 18.2 x 7.2 cm Particle concentration in particles/litre, for all size channels or Particle mass in µg/m³, for all size channels. No filter validation for Particle mass fractions according to EN 481 occupational (inhalable, thoracic, respirable) and environmental (PM 10, PM 2.5, PM 1 ) Data output via Windows ® software

18 Dr. Friedhelm Schneider specification: Bioaerosol spec. with particle sampling on glass slide (+ microscope) Specifications #1.109 Particle counting up to P/l Dust range [µg/m³] 0.1…> Size Range [µm] 0.25…>32 Size channels [µm] 31 channels counts 32 channels mass (0.23)/0.25/0.28/0.3/0.35/0.4/0.45/0.5/0.58/ 0.65/0.7/0.8/1/1.3/1.6/2/2.5/3/3.5/4/5/6.5/ 7.5/8.5/10/12.5/15/17.5/20/25/30/32 µm Sample air flow rate 1.2 l/min, volume controlled Power supply battery 12VDC (up to 8h) or 110…230VAC Weight/Dimensions 2.4 kg (5.3lb) with battery / 24 x 13 x 7 cm Particle concentration in particles/litre, for all size channels or Particle mass in µg/m³, for all size channels. No filter validation for Particle mass fractions according to EN 481 occupational (inhalable, thoracic, respirable) and environmental (PM 10, PM 2.5, PM 1 ) Data output via Windows ® software

19 Dr. Friedhelm Schneider specification: Nano attachment for 1.108/1.109 measures Nano counts and mean diameter Specifications #1.320 Size Range 25…300nm Size channels 1 accumulative Particle counting >500 P/ccm Sample air flow rate 1.2 l/min, via 1.10X volume controlled Power supply battery 12VDC (16h) or 110…230VAC Weight/Dimensions 1.4 kg / 12 x 7 x 7 cm Mean particle concentration in particles/ccm, for whole size range and mean particle diameter in nm. Data output via Windows ® software Portable, no butanol, no radioaktive source!

20 Dr. Friedhelm Schneider Applications: IAQ and Occupational model and model and Occupational workplace monitoring EN 481 monitoring and PTFE-filter analysis for heavy metal Nano Counter attachment for Indoor application, model 1320 IAQ (indoor air quality) monitoring laser printer emissions, IAQ mass fractions and counts ventilation efficiency control at workplaces IAQ-research passive smoking, comparison indoor and outdoor (PM, EN 481) emissions of laser printers, with high time resolution Industrial process control isokinetic in stack sampling droplet measurements, size distribution stationary and mobile monitoring of dust with alarm unit

21 Dr. Friedhelm Schneider Applications: Filter testing, ventilation control, Wide Range continuing model and continuing model and Atmospheric research measurements with airplanes, battery powered high time resolution vertical profiling of urban aerosols WRAS Wide Range Aerosol Spectrometer emission control and ambient air monitoring model Sky-OPC, Bioaerosol Spec. model 7.300, 7.309, an model Sky-OPC, Bioaerosol Spec. Atmospheric research Bioaerosol research and monitoring model 7.300, 7.309, an Filter-testing, ventilation control filter test systems, filter test rig online ventilation control

10th China Aerosol Conference Changchun, July 26-Aug. 1, /20 Measurement Results Measured along the highway from Graz to Linz in Austria. Austria is a mountainous country in central Europe and thus many highways often pass through many mountain tunnels Spectrometer A car (TDS BMW) ran in front of our car. Gleinalmtunnel (8.3km) Bolsrucktunnel (5.5km) Speringtunnel 2.8km and Klausertunnel 2.1km When we passed by some heavy duty trucks (LKW), the instrument showed several subpeaks.

23 Dr. Friedhelm Schneider Applications: Occupational work- place monitoring + PTFE filter for chemistry in indoor fibre- glass protection housing, model 164, with sensor for temperature and relative humidity. PTFE filter used for chemical analysis of heavy metal. Work place monitoring in production area, Ecoanalytic, Switzerland, 2008

24 Dr. Friedhelm Schneider Applications: Occupational work- place monitoring Nano attachment or with Nano attachment model 1320 for workplace monitoring of ultra fine particles and dust mass fractions (or counts), with one portable system. Grimm Aerosol Technik, 2008

25 Dr. Friedhelm Schneider Nanoparticle Exposure during Soldering background soldering combustion and decay

26 Dr. Friedhelm Schneider Applications: IAQ Indoor Air Quality monitoring of laser printer emissions online IAQ monitoring for fast results in offices. Emissions of laser printers (IAQ mass fractions and counts in 15 channels). IAQ measurement in office, Landesamt für Verbraucherschutz, Magdeburg, Germany, 2008 IAQ mass fractions counts (15 channels)

27 Dr. Friedhelm Schneider Applications: IAQ Indoor Air Quality, ventilation control with sampling inlet and sensor for humidity, temperature and velocity model Control of ventilation system at workplaces. IAQ measurement in production area, TECAN, Austria 2006

28 Dr. Friedhelm Schneider Applications: IAQ-research Indoor Air Quality, PM values in Pubs Online measurement outdoor and indoor with and sampling inlet model acc. to European guideline EN 481, measuring simultaneously inhalable, thoracic and alveolic mass fraction (or PM10, PM2.5 and PM1 for relative comparisons). Landeskrankenhaus Salzburg, Lungenabteilung, 2006

29 Dr. Friedhelm Schneider Applications: IAQ-research PM in offices, Scientific research Measuring particle emission from copy machines and laser printers in offices online with high time resolution with University of Gießen, Germany, 2006 Printing!

30 Dr. Friedhelm Schneider Applications: Industrial process control, isokinetic in stack sampling Model sampling probe for isokinetic in stack sampling with four changeable inlets for air speeds up to 25m/s and air recirculation with pipe in pipe technology to measure without exerting pressure!

31 Dr. Friedhelm Schneider Applications: Industrial process control for solid particles AND liquid droplets with model for isokinetic sampling and model sensor for humidity, temperature and velocity. Measuring of particle size distribution of droplets under various operation conditions. LUMI Michelbach, Germany and Grimm Aerosol Technik, 2008

32 Dr. Friedhelm Schneider Applications: Industrial process control, stationary and mobile with alarm unit with acoustical and visual alarm unit in indoor fibre-glass protection housing, model 164 with T and rH sensor. EADS, Augsburg, with acoustical and visual alarm unit (model 1.147C), if a dust threshold is exceeded. Specification: 110dB sound and flashing light.

33 Dr. Friedhelm Schneider Applications: atmospheric research, airborne particle distribution Airplane measurements with for particle size distribution, online and battery powered! Campaign in Australia, IMK-Garmisch-Partenkirchen, Germany, 2007

34 Dr. Friedhelm Schneider Applications: atmospheric research physical properties and chemistry Spectrometer mounted at a Cessna wing cross beam with a isokinetic inlet for particle sampling inlet during flight. University of Hohenheim and FU-Berlin, 1998 Engelhardt T., (2005): Lasermikrosonden-Massenspektrometrie atmosphärischer Aerosolpartikel. Dissertation, Universität Hohenheim, 2004, ISBN , Shaker Verlag GmbH, Aachen spectrometer mini-cascade impactors for aerosol particle sampling isokinetic sampling probe plexiglas wind protection

35 Dr. Friedhelm Schneider Applications: atmospheric research vertical aerosol profiling, Milano, Italy spectrometer for vertical aerosol profiling with a balloon With permission of Luca Ferrero, Milano Bicocca University, Italy, presented at EAC, Salzburg 2007

36 Dr. Friedhelm Schneider Applications: mobile WRAS for exhaust emissions, 3 locations, Bozen, Italy Background air Highway Sampling system, with permission of Dioxin Monitoring Systems, Kottingbrunn, Austria WRAS SMPS+C and Thermal waste combustion energy plant Exhaust air

37 Dr. Friedhelm Schneider Applications: atmospheric research in high altitudes, Sky-OPC model IfT Leipzig, Germany, 2008 Helicopter carried platform ACTOS with Sky-OPC for measuring submicron particles with 1 second time resolution up to 6km altitude, independent on air pressure.

38 Dr. Friedhelm Schneider Applications: Bioaerosol research, model Bioaerosol spectrometer In the lab: Bio-aerosol wind tunnel for testing emission and impaction of micro organisms. In the field: Bioaerosol particles sampled in a stable for animal husbandry. University of Hannover, Institute of Animal Science, Germany, 2007

39 Dr. Friedhelm Schneider Applications: Filter testing principles - volume controlled filter test, simultaneous upstream and downstream measurements - continuous filter testing for ventilation control - filter test according to ASHRAE - automobile filter test according to ISO and others

40 Dr. Friedhelm Schneider Applications: Filter tests, test rigs with Grimm technology inside Filter test system e.g. with Grimm Model (fine) or (coarse) for validation of air filters, e.g. used for cars and automotive industry. Mann + Hummel, Germany published in “Messen und Sensorik” 2008 Filter, used in Audi A8

41 Dr. Friedhelm Schneider Applications: Ventilation control with dual filter tester Electrostatic participator for 50 m³/sec Airflow Online efficiency control of ventilation systems (e.g. electrostatic participators in tunnels) with dual filter tester model Upstream and downstream simultaneously! Data output in counts (31 channels) or mass. Filtrontec, Germany (tunnel project Calle30, Madrid, Spain),

42 Dr. Friedhelm Schneider number size mass Grimm instruments measure particle number concentration and particle size and you can obtain particle mass with high time resolution and high accuracy! For indoor AND outdoor application!