International technical training July China Mr.Zeng 2010-11-9.

Slides:



Advertisements
Similar presentations
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Advertisements

Basic Jens Neigaard.
Supervisory Control & Data Acquisition DAQ Networking.
Ethernet “dominant” LAN technology: cheap $20 for 100Mbs!
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.

Digital Adressable Lighting Interface (Basic information)
PICNIC Demo Module 2 IP-based utility outlets 陳育瑋、方煒 台大生機系.
EUT 1040 Lecture 10: Programmable Logic Controllers.
Communication Links Communication Link = Physical connection or Physical Medium Types: Wire Pair or Twisted Pair Coaxial Cable Fiber Optics Bandwidth,
Computer Control. Computer Control Basics Input – (Sensors) Processing – (Black Box) Output – (Actuators)
EUT 1040 PLC Timers and Motor Protection. Industrial Communications RS-422 (EIA 422): Asynchronous Serial Communications, similar in many respects to.
Chapter 8 Output Modules.
COMPUTER NETWORKS.
ZIGBEE Network Introduction Integrated with Zigbee or Bluetooth products Operation voltage : DC 7V ~ 40V. RS232 Interface Meets or Exceeds TIA/EIA-232-F.
TRIAC Dimmable Ac-Dc LED Drivers VLED 15 Series. © 2012 CUI Inc Introduction Purpose To provide an overview of the VLED15 Ac-Dc LED power supply and its.
1 Computer Networks Course: CIS 3003 Fundamental of Information Technology.
Controller Wiring.
Technology Training that Works Hands of Data Communications, Networking & TCP/IP Troubleshooting.
USART Communication using the RS standard ETEC6416.
EMBEDDED WEB SERVER. CONTENT: 1.ABSTRACT 2.INTRODUCTION TO EMBEDDED SYSTEMS 3.INTRODUCTION TO EMBEDDED WEB SERVER 4.BLOCK DIAGRAM 5.POER SUPPLY 6.COMPONENT.
0 RS-485 MODBUS COMM. D. Digital Trip Relay 6. IO (Input-Output) Port Profibus -DP COMM. Digital Trip Relay - P and S type are equipped with RS- 485 communication.
Laudon & Laudon: Canadian Edition
Communications and Networks Chapter 8 in Discovering Computers Fundamentals.
Chapter 2 The Infrastructure. Copyright © 2003, Addison Wesley Understand the structure & elements As a business student, it is important that you understand.
PROFIBUS wiring/installation can be done with:
© Paradigm Publishing Inc. 6-1 Chapter 6 Telecommunications and Networks.
Arctic RS-485 / RS-422. RS- 485 Also known as RS-485 Half Duplex, RS wire same pair is used to transmit and receive data only one device can transmit.
AS Computing F451 F451 Data Transmission. What data is transmitted? Phone SMS Radio TV Internet.
ITED 328 Lecture 4 12 Feb 2004 Loosely covering Chapter 5 Internet and LAN Technology.
Chapter 7 Networking: Computer Connections. Networks n Network - a computer system that uses communications equipment to connect two or more computers.
Application Protocol for Veris E30 Panel-board Monitoring System Jaein Jeong UC Berkeley LoCal Workshop Oct 5 th, 2009.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
Front-end Product Training Program –Speed Dome. Table of Contents  Speed dome classification  Speed dome basic information  FAQ  Upgrade.
Thaksalawa Web Site Group Project Transmission of data from one place to another place is called Data Communication.
DLP LCD PANEL Programming
UNIT -1. DATA COMMUNICATIONS The term telecommunication means communication at a distance. The word data refers to information presented in whatever form.
Chapter 4 Telecommunications and Networking The McGraw-Hill Companies, Inc All rights reserved. Irwin/McGraw-Hill.
Summary - Part 2 - Objectives The purpose of this basic IP technology training is to explain video over IP network. This training describes how video can.
McGraw-Hill©The McGraw-Hill Companies, Inc., 2004 Connecting Devices CORPORATE INSTITUTE OF SCIENCE & TECHNOLOGY, BHOPAL Department of Electronics and.
3/20: Telecommunications & Networking What is telecommunications? The hardware: physical components of telecommunications, inc. channels Standards: agreements.
Ethernet Chapter 4.
Programmable Logic Controllers
HDL-Bus International Technical Training Mr. Zeng Last revision: Aug 28, 2013.
System Frame and Protocols
Unit 3 Physical Layer.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
MRDA Wiring diagram S-BUS Module ID setting button ballast L N DC0-10V dimming voltage Control DC Maximum current :100mA 6 relay switch 16A 6 channel.
Data Communication and Networks Chapter 5. What’s a Network? a network consists of two or more computers that are connected together to share information.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
Lecture 2 unit 1.
Buspro system introduction program preparation important notes
1. PIC ADC  PIC18F877 has 8 analog input channels i.e. port A pins(RA0 to RA5) and port E pins(RE1 and RE2). These pins are used as Analog input pins.
Buspro system introduction program preparation important notes
Lecture 10: Programmable Logic Controllers
System Important Points for Wiring
Industrial communication networks
Wireless Power Interface
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
Site Controller Unit and Trunk Interface Unit
Wireless 4 Buttons Touch Panel
Wireless 3 Buttons Touch Panel
Connections Topology of Apollo ACS.
A Patented Product.
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
A Patented Product.
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
LED Driver Training.
Presentation transcript:

International technical training July China Mr.Zeng

单击添加标题 structure of network Connect to Core Network DMX512 RS48 5 Ethernet DC Power AC Power 0-230VAC AC230 Input DMX5 12 Cable resistance Device ConnectDevice Connection Standard of Bus power supply Net/IP Sending data via cable IP interface Protocol of S-Bus structure of middle and large network Usb Structure of special network medium of IP core network 16A relay 10A relay dimmer with leading edge dimmer with trailing edge ballast LED Driver motion sensor IR learnIR learner IR Code for Air conditioner Z-audio SMS

Cable Type of Bus: * Twisted-pair, better with shielding. * Twisted-pair wire can avoid and reduce the noise in the Bus * The Regulation of Connection in S-Bus: Orange + Brown : DC24V Blue + Green : DATA+ Blue White + Green White : DATA- Orange White + Brown White: COM Return

Resistance of Cable Per 100m With two wire connect to together: 5 ohm * Please confirm the rate of resistance of Cable, the typical rate of CAT5 cable in China about 5 Ohm * Different brand cable have different rate of resistance,some less some more Return

Method of connection Devices in Bus * recommend to use hand by hand * In some projects can use star network topology within limits Return Device 1Device 2Device 3DeviceN

* Standard of Bus in use: RS485 Two way communication, has two signal which is one Data+ and another is Data-,named differential signal * Total length of Cable in Bus: 1.2Km Note: need consider, the drop of voltage on the end of Cable, power supply, method of connection which is hand by hand or Star network topology * Max. Devices No. on one twisted pair Bus:64 consider power supply via Bus and high efficiency communication, recommend less 64 devices on one Bus even our driver can drive 256 device on the bus * S-Bus serial baud rate for twisted pair: 9600bps 11 bit serial data: 1bit start,8 bit data, 1 bit even, 1 bit stop Return

* DC power supply in Bus : DC24V calculate all power consumption in Bus,according to the voltage drop of cable, select the power supply and cable length. * Max. drop of voltage in Bus acceptable magnetic latching relay require more then 15V, other device require more then 8V, the standard of voltage is used DC24V, the max. voltage up to DC 30V * Safety for safety reason,the protection current of power supply must under the current which is when the Bus has circuit short happened, so we need to calculate the resistance on the Bus,calculate total the power consumption in Bus, then select the correct power supply Return

* S-Bus Net/IP Network UDP protocol in detail Use group broadcast and use 6000 port as default and C, B class used for UDP communication on IP network. UDP protocol packing and unpacking the data stream which come from the twisted pair(RS485) or the data get to RS485 Return

* Sending data stream in twisted pair Busy checking, sending serial data,receiving data stream, comparing the data which sent same with received, so in system no master or slave device, any of devices in Bus can send command by needs. * Collision Detection,Carrier Sense Return

* S-Bus IP interface IP interface used for fast intelligent data exchange (router) between the Subnet, big network, integrate with other system, managing and monitoring the system, program for the device on the bus. * Regulation of Net/IP route 1,all of message come from RS485 Bus will be send to Net/IP network by IP interface, 2, the message come from Net/IP network will be send to RS485 Bus if the destination Subnet ID of the message match IP interface’ Subnet ID or the destination ID is a broadcast Subnet ID,this mechanism can improve the efficiency of communication Return

* Protocol of S-Bus in detail Subnet ID:0-254(255 for broadcast),DeviceID:0-254 (255 for broadcast), Max. data size in a data pckage:80 byte, CRC standard for data package: 16bit, two byte for CMD. Total devices in Bus: 255 x 255 = 65025, data package in the twisted pair(RS485) same contents with in the IP network, the method of communication: point to point and broadcast. The protocol show as below: Return

* Ethernet HUB + 2 to 8 IP interface + 2 to 8 twisted pair Cable middle system like a small building, park,museum ect., strong recommend each IP interface with different Subnet ID, one twisted pair cable for less then 64 devices Return Ethernet HUB IP Interface Core network individual Twisted pair S-Bus, Max. 64 devices Subnet ID 1, device ID 0 Subnet ID 2, device ID 0 Subnet ID 4, device ID 0 Subnet ID 4, device ID Subnet ID 1, device ID OPC Server

* Structure of special network many device with IP interface combination one network in one twisted pair Bus show as first page, only one of IP devices can be used as gateway, otherwise the network will be a ring and blocked Return

* Medium of Ethernet in core network S-Bus system can use many medium to communication base on the standard network IP network such as CAT5, WiFi, Fiber optical, microwave, Bluetooth etc. Return

* integrate with other system many kind of protocol and interface can be used to integrate with other system: 1,OPC server 2,UDP protocol 3,EIB gateway 4,RS232 gateway 5,DALI gateway 6,DMX gateway, 7,IR code 8, BackNet 9,lonworks ……. Return

* Using 50A magnetic latching relay have high capability for ON/OFF control, 230VAC Motors: 4HP Incandescent lamp load: 3500W Inductive transformer : 1800 W Electronic transformer: 2000 W Halogen lamp 230 V : 3500 W Mercury-vapour lamp * Uncompensated luminaire: 2800 W * Parallel compensated : 2800 W Fluorescent lamp T5 / T8 * Uncompensated luminaire: 3500 W * Parallel compensated : 2000 W * DUO lamp : 2000 W Dulux lamp * Uncompensated luminaire : 1500 W * Parallel compensated : 1500 W Return

* Using 16 A relay High capability for ON/OFF control, 230VAC Motors: 1HP Incandescent lamp load: 800 W Inductive transformer : 500 W Electronic transformer: 400 W Halogen lamp 230 V : 800 W Mercury-vapour lamp * Uncompensated luminaire: 500 W * Parallel compensated : 350 W Fluorescent lamp T5 / T8 * Uncompensated luminaire: 500 W * Parallel compensated : 350 W * DUO lamp : 400 W Dulux lamp * Uncompensated luminaire: 500 W * Parallel compensated : 350 W Return

* pay attention to the dimmer with leading edge, using TRIAC for dimming 1,Keep the environmental temperature lower than 45 centigrade, because it bring heat when have output active, 2, High power dimmer will make a little noise when it is dimming so make sure the place fit for install the dimmer. 3,Make sure the Loads have no circuit shorted otherwise it will be burning. 4, Suitable for incandescent lamp, Induction transformer, some of electronic transformer, motor load 5, Can not used for electricity-saving lamp, none dimming load,some of electronic transformer. 6, Minimal load 30w Output Waveform Return

* pay attention to the dimmer with trailing edge, using MOSFET for dimming 1,keep the environmental temperature lower than 45 centigrade, because it bring heat when have output active. 2, suitable for incandescent lamp, all of electronic transformer. 3, also good used for electricity-saving lamp, none dimming load for ON/OFF control. 4,not good for inductive load, maybe lead the protector of dimmer burning Output Waveform Return

* pay attention to the ballast dimmer with ON/OFF switch and DC 0-10 voltage control 1, dimmable ballast need ON/OFF control even it has 1-10V voltage for dimming. 2,Each channel ON/OFF for 2000w load. 3, DC 0-10V terminal designed for get the current in from ballast,can not output current to the ballast 4, Output DC current of ballast is less 1mA each ballast normal. 5,DC control terminal have capability of 100mA by each channel Return

* Pay attention to the LED Driver 1,DMX512 protocol for dimming. 2,Constant voltage drive for RGB LED. 3, Constant Current drive for RGB LED (planning to do ) Return

* Pay attention to the motion sensor 1,The sensitivity of motion sensor depend on the temperature, the higher of temperature lead the lower of sensitivity, recommend the temperature of environment lower than 35 deg. 2, In door using, the wind maybe lead the sensor wrong operation when using out door. 3,Avoid to install nearby the air outlet, the reason same using out door. Return

* Pay attention to the IR learn 1,keep the IR learner with IR remote control in same straight line. 2,the IR learner close to remote control Return

* Pay attention to the IR Code for Air conditioner 1,all of remote control combine many parameter into a IR code, so only one of function like temperature can be used, means other function can not be changed 2, using gateway to integrate like RS232,RS485,ethernet,lonworks or put the IR protocol into the IR transmitter directly or develop another kind of IR Return

* Pay attention to the Z-audio 1, need DC +24V and DC -24V power supply. 2, need to connect RJ45 for manage software Return

75% Output AC Input Leading Edge Trailing Edge TRIAC MOSFET

50% Output AC Input Leading Edge Trailing Edge TRIAC MOSFET

25% Output TRIACTRIAC MOSFETMOSFET AC Input Leading Edge Trailing Edge TRIAC MOSFET

* Pay attention to SMS 1, Support four frequency (Siemens MC55i now used ) : 850MHz/900MHz/1800MHz/1900 MHz Support two frequency (Siemens MC52i before used) : 900MHz/1800MHz 2, SMS service center Number for send SMS 3, the LCD display will show status at Mail box when receive a message 4, need to connect RJ45 for manage software Return