1 INPUT & OUTPUT ■ INPUT * Voltage Side ( PT side ) Operational range : 0-110% Permissible over range : 150% for 10 seconds 120% continuously * Current.

Slides:



Advertisements
Similar presentations
MEGATRON. Privately owned shares company founded at The company is engaged in manufacturing Measu- rement, Monitoring and Control equipment. Megatron's.
Advertisements

SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
Transformer Coupling.
1 ■ RTD INPUT 2 or 3 wire RTD ’ S input sensing : 2mA DC(pt) MODEL & SUFFIX CODE HD-GPMA MODEL ORDERING INFORMATION Specify code number and variables *

1 5A 200A 6600V HOW TO DETERMINE LIE WATTAGE... WATT The standard voltage rating is 110V, the standard current rating is 5A, the transducer range is 1000W.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Troubleshoot The AC Circuitry
TRANSFORMERS. TRANSFORMER PARAMETERS Turns Ratio (n) It is defined as the ratio of the number of turns in the secondary winding (N sec ) to the number.
Lecture II: Linear Applications of Opamp
BASIC ELECTRONICS.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Common Equipment 2 : DC power Supply Common Equipment 2 : DC power Supply ---MODEL LPS-305 Motech.
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Calibration of I/P (current/Pressure) Honeywell Chapter 8 InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer.
1 Chang Shuan Eletronics Co., Ltd
Transistor Amplifiers
Regal Beloit Proprietary & Confidential What do I get? The X13 motor is a permanent magnet, three phase,brushless DC motor. A single phase drive is attached.
DUAL POWER SUPPLY MODULE
Controls and Electrical Preferred Technologies Steve Pavis PH-DT-DI CERN Advel Power Supplies and ABB Circuit Breakers.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
Biomedical Instrumentation I
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
1 SPECIFICATION Power : DC 24V ± 5% Input Signal : RS – 485 SERIAL Display: 4 DIGIT LED (H:10.16mm) Address Selection : POWER TO INPUT Isolation: POWER.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Remote AI (Add 6 inputs/units, Max 48 inputs/recorder) VM7000A RS-485(Max 1200m) Remote AI (Max: 6 units) Recorder 12 CH Remote AI 6CH x 6units TTL: 48.
ISA CIRCUIT BREAKERS TEST SETS
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
7 Programmable DC Power Supply EPS Series ■ Features & Benefits * Linear type power supply * Easy to control voltage & current with jog shuttle * 4-Digit.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
7. Design of BJT, Op. Amp., IC Regulated Power Supplies
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Done by: Khalid Hijjawi Mohammad Massad.  Is an electrical instrument that measures electrical resistance, the opposition to an electric current. The.
D.C. Machine & Transformer Topic: Instrument Transformer Electrical:-1 presented by: Jill Chauhan ( ) Chirag Agarawal ( )
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
SPECIFICATION FOR APPROVAL ( PB-FREE APPLICATION ) CUSTOMER:BERESEE Co., Ltd ITEM: POWER SUPPLY UNIT (for 37” ~ 42 ” HD MNT) DESCRIPTION:260W BUILT-IN.
1 5A 200A 6600V HOW TO DETERMINE LIE WATTAGE... WATT The standard voltage rating is 110V, the standard current rating is 5A, the transducer range is 1000W.
Part Three – Relay Input Sources
1/10 1. General Description 1.1 Product Description This Specification defines the input, output, performance characteristics. Environment, noise and safety.
SWITCH-MODE POWER SUPPLY or SMPS SMPS are power supplies that operate on a switching basis.
Bevochtigen Ontvochtigen Temperatuur Timer / Fan AC 220V / DC 12V
Training on Power Monitoring and Management Solution
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
ECE 445 Smart Window Responding System
HD POWER TRANSDUCER SERIES
ABB i-bus® KNX Valve Drive Actuator VAA/A
HD POWER TRANSDUCER SERIES VOLT-DEMAND TRANSDUCER
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
(a) Find the value of average charging current,
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
HD SIGNAL CONDITIONER SERIES
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
HD POWER TRANSDUCER SERIES
HD POWER TRANSDUCER SERIES
FEEDER PROTECTION UNIT
Unit 3 – Fundamentals of Electronics Examination Specifications
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Unit 3 – Fundamentals of Electronics Examination Specifications
Lesson 11: Transducer Electrical Interfaces
Electronic relay ER/U 1.1 contact TU/W 1.1 US/U 4.1 ER/U 1.1
HD POWER TRANSDUCER SERIES
HD SIGNAL CONDITIONER SERIES
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Series 5300 Lithium Cell Formation System
PowerLogic™ offer for the basic metering market
easYgen-3000XT Series Training
Presentation transcript:

1 INPUT & OUTPUT ■ INPUT * Voltage Side ( PT side ) Operational range : 0-110% Permissible over range : 150% for 10 seconds 120% continuously * Current Side ( CT side ) Operational range : 0-120% Permissible over range : 1000% for 5 seconds 150% for 10 seconds 120% continuously Frequency : 60 or 50Hz HDWWH MODEL ■ PHASE & WIRE ■ VOLTAGE & AMPERE ORDERING INFORMATION Specify code number and variables * Code number : HDWWH-phase/wire-voltage/ampere -Analog output-pulse mode-pulse range ex : HDWWH-4AAA1 * special output range : code 0 A = -10~20mA, V = -10~12V Pulse range : Hz GENERAL SPECIFICATIONS Construction : DIN housings Terminal access on front face Housing materiel : plastic(black) Wiring : 3.0M screw terminals Isolation : AC input/DC output/power PERFORMANCE Accuracy : 0.1% or 0.25% Temp.coefficient : 0.03%/C Insulation resistance : 100Mohm or more with 500V DC Response time : 0.4sec(400ms) Line Voltage effect : 0.1% with 10% change Ripple : 0.25% p-p max. (100/120Hz) Dielectric strength : 2000V AC 1minute input/output/power Surge withstand Voltage : 1.2/50  sec,  5KV (INPUT to OUTPUT to GROUND) INSTALLATION Operating temperature : -5 to +55C Operating humidity : 20-80%RH(non-condensing) Mounting : Wall or DIN rail Power supply : AC 110V or 220V (-15/+10%) 50/60Hz,2VA Size : W75 H150 D113mm Weight : The W&Watthour transducer Model HDWWH provides a DC signal output and PULSE proportional to AC active power * Little ropple : stable output * Input - output isolated * Frequency output available for totalizing ■ OUTPUT * PULSE OUTPUT * PULSE MODE * PULSE RANGE * ANALOG OUTPUT HD POWER TRANSDUCER SERIES W&WATTHOUR TRANSDUCER MODEL HDWWH - MODEL & SUFFIX CODE SELECTION Adjustments : zero and span  5% Over-range output = 0-120% 1P2W 3P3W 3P4W

2 ■ INPUT RANGE 1-PHASE/2-WIRE1-PHASE/3-WIRE 3-PHASE/3-WIRE 3-PHASE/4-WIRE  pulse ratio = Calibration WATT range / 1hour [example] 3-phase / 3-wire 110V. 5A. 1000W pulse range = 1000 pulse / 1hour ■ HOW TO DETERMINE PULSE WATTHOUR PULSE RATIO RANGE Measuring Wattage Calibration Range [W] = PT ratio x CT ratio Check that the required calibration range is within the available range in the table WATTHOUR PULSE RANGE 1 pulse ratio = PT ratio x CT ratio x Wh [example] 3-phase / 3-wire 110V. 5A PT : 3300V/110V CT : 250A/5A 1 pulse ratio = 30 (PT ratio) x 50 (CT ratio) x Wh = 1500Wh ■ OUTPUT DC Current : 0-20mA DC Minimum span : 1mA zero bias : max. 1.5 Times of span LOAD resistance OUTPUT LOAD RESISTANCE IMPEDANCE 4-20mA Ω 5M Ω or more 0-20mA Ω 0-16mA Ω 0-10mA Ω 0-1mA 0-12k Ω 0-5mA Ω DC Voltage : 0-12V DC Minimum span : 5mV zero bias : max. 1.5 Times of span OUTPUT LOAD RESISTANCE IMPEDANCE 0-10mV 10k Ω or more 1 Ω or less 0-100mV 100k Ω or more 0-1V 1k Ω or more 0-10V 10k Ω or more 0-5V 1-5V 5k Ω or more 10 Ω 100 Ω * for other ranges within 0-12V, use equation R = E/I where : R = load resistance ( Ω ) E = full-scale output (V) I = 1 mA HOW TO DETERMINE WATTAGE RANGE Measuring Wattage(W) = PT ratio  CT ratio  STANDARD RANGE[W] Check that the required calibration range is within the available range in the table, specify this range when ordering. [example] 3-phase/3-wire, PT 3300/110V, CT 250/5A Measuring wattage = 3300/110  250/5  1000w = 150KW

3 CONNECTION DIAGRAM DIMENSION & INSTRUCTIONS * MODE A. Open collector B. Relay contact C. Voltage pulse Min 1 V DC 100mA Relay Capacity High + 15V 5mA Max 20V DC 100mA 100V, 0.1 A Low 0V * ON duration : 250 msec. [ min, 50msec., max. wattinput range/1hour  1/2 sec * Frequency range : 0 - 2,777Hz ■ OUTPUT