Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.

Slides:



Advertisements
Similar presentations
DESIGN LAYOUT OF DISTRIBUTION SYSTEMS
Advertisements

Modern pipe network models
City of Black Hawk Water HammerSeptember 2002 Arber Water Hammer Travis Meyer, P.E. Richard P. Arber Associates.
Automatic Nozzles. 1960’s & 70’s  Automatic pressure regulating nozzles invented 1960’s & 70’s  Automatic pressure regulating nozzles invented Hand.

BS9990 : 2015 Updates and/or Changes
Expect More. World’s leader in pressure technology NA Sales Training Rev B – 10/10/13.
1 Expertly Engineering Safety From Fire NFPA 25 As A Means to Improve Sprinkler System Reliability William E. Koffel, P.E., FSFPE President Koffel Associates,
N.F.P.A. 13R Justin Bohlmann FIR-204.
London, 21 May 2014 Alan Brinson A European Residential Sprinkler System Design, Installation and Maintenance Standard.
Rule Change Update MPCA 1/13/ Mid-Sized ISTS (MSTS)
Pumping Apparatus Driver/Operator
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Residential Fire Sprinklers Building Codes Plan PreparationPlan Preparation The sprinkler contractor should be required to submit a set of complete, detailed.
Presented by: Blaine W. Rabe’ Division Manager for the Property Insurance Association of Louisiana.
STANDARD ON WATER SUPPLIES FOR SUBURBAN AND RURAL FIRE FIGHTING
Development Services Branch Building Services Section Kevin Kannis – 12 November 2014.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
Characteristics of Water
Purpose of Standpipe and Hose Systems
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
C L A S #4 Driver Operator Refresher Training.
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
BLM National Training Center HYDRAULIC DESIGN PART 2.
1 Pipe2000 Campus Facilities Modeling by Dr. Don J Wood Pipe2000 Modules.
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
NFPA 13: Installation of Sprinkler Systems
Water Systems for Livestock Joe Zulovich Extension Agricultural Engineer Commercial Agriculture Program.
Proposed Improvements to the Water System Infrastructure in the Anacostia Area of Washington, D.C. November 20, 2002 Prepared by Prepared for Our Customers,
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
EPANET FOR PRESSURIZED PIPE SYSTEMS
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Distribution System Control Strategies.  Tank Management/Operations  Flushing  Rerouting Water  Others  optimizing existing booster chlorination.
Water Supply.
Fresno County Fire Protection District. Fire Sprinklers Systems Residential – 13D October 30, 2007.
Wareham Fire District Water Department Glen Charlie Road Water Storage Tank Special District Meeting June 23, 2009.
Improving Service to Customers by Decommissioning an Elevated Water Storage Tank Jon C. Ford P.E. – Seattle Public Utilities AWWA-PNWS Conference April.
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
Water Distribution Systems. Distribution systems Designed to adequately satisfy water requirements for combination of: Domestic use Commercial Use Industrial.
Imagine the result Impact Study on MSD Rate Payers of Proposed Consolidation/Merger Phase II – Towns of Biltmore Forest, Montreat and Weaverville Presentation.
Pre Incident Planning and Related Loss Reduction Strategies
Lecture 1 Water Distribution Systems
Residential Fire Sprinkler Concerns. Water Supplier Reliability Issues Water Supply Water Facilities Water Quality Cost.
Safe Drinking Water Permit and Capacity Requirements Developer Services Summit November 16, 2010 Engineering - Asset Planning Vince Monaco.
VisiMix Pipe Line VisiMix Ltd, PO Box 45170, Jerusalem, 91450, Israel Tel: Fax:
10 Frequently Asked Questions about Center Pivots Gulf Coast Irrigation Conference Sinton, November 18, 2008 Guy Fipps Professor and Extension Agricultural.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
HVACR116 – Trade Skills Longest length method.
Network Appurtenances Major operations within a water transport and distribution systems are: 1. Transmission. 2. Storage. 3. Pumping.
Infrastructure management system Managers and engineers need clear guidelines for life-cycle management of infrastructure systems for water, sewer, and.
Recycled Water Distribution System Challenges Lee Cesario, P. E. Denver Water
April 21, 2015 Presented by: Heidi Springer, P.E. Brian Ginter, P.E.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Borrego Water District Revenue Workshop. Potential Revenue Sources  Background  Service Area Relatively Small  Largely Undeveloped  Absentee Owners.
Components of Water Networks Eng. Mona Al-Gharbawi Eng. Ayman Al-Afifi
Sprinkler Loads on Trusses
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
CarolloTemplateWaterWave.pptx City of Bainbridge Island Water System Plan Policy Discussion April 21, 2015.
Water System Master Plan & Rate Study City of DeKalb, Illinois City Council Presentation May 16, 2015.
Washington Surveying & Rating Bureau  Who Are We?  What Do We Do?  How Does Insurance Rating Promote Sprinkler System Installations and What Obstacles.
Coachella Valley Water District Water Service and Water Meter Sizing Criteria Workshop April 13th from 10:30-11:30am April 19th from 1:30-2:30pm 1 CVWD.
Irrigation Management Practices Cropping A*Syst Katie L. Droscha 01/14/ /15/2013.
Water System Infrastructure
Lecture (11): Water Distribution Systems
Water Booster Station Improvement Study
Plumbing system fundamental and design course
Infrastructure & Safety
Presentation transcript:

Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE

2 Water System Design Public water systems are generally designed and analyzed hydraulically based on: 1.Peak hour domestic demands 2.Emergency condition purposes (typically fire fighting and or power outage)

3 Service Application Process: Who Does What?  Developer: Procures Design Professional to calculate domestic and fire flow demands. Ensures that Fire Official signs Needed Fire Flow (NFF) Worksheet.  Design Professional: Calculates expected domestic demands and building’s NFF. Typically will prepare and sign the NFF Worksheet on behalf of Developer.  Water Company: Evaluates system hydraulic and storage capabilities based on Design Professionals demand calculations. If necessary, identifies system improvements to adequately deliver NFF.

4 What Water Company Does Not Do  Prepares or reviews any Automatic Fire Suppression System (AFSS) calculations  Requests Fire Official to sign NFF Worksheet  Requires existing customer base to finance system improvements to be used for applicant’s benefit.

5 Water Company “Behind the Scenes” Analyses  Performs regulated Supply Capacity review to ensure system can add new customer demand.  Performs Hydraulic Modeling analyses using applicant’s projected demands. Extended Period Simulation identifies if new demands will create any service pressure, excessive velocity, or storage impact(s) to existing system.

6 Water Supply Essentials for Fire Fighting  Rate of flow (gpm)  Residual pressure at that flow (psi)  Expected duration to contain a fire (hours)  Total quantity of supply needed (gallons)

7 1,000 feet, 6-inch Diameter, C= feet, 6-inch Diameter, C= feet, 8-inch Diameter, C= psi 29 psi 17 psi 48 psi 750 gpm Existing System + New Demands gpm NFF OK NG Example: NFF creates <20 psi residual pressure Existing System + New Demands gpm NFF

8 Existing System with 500 gpm NFF Existing System + New Demands & 750 gpm NFF 75,000 gallons 15,000 gallons 0 gallons 500 gpm x 120 mins = 60,000 gallons 750 gpm x 120 mins = 90,000 gallons OK NG Example: NFF could drain existing storage volume

9 American Water Planning Criteria DISTRIBUTION PIPING, PUMP AND STORAGE EVALUATION The ability of distribution system facilities to provide safe, adequate and reliable service to customers is analyzed based on: forecasted customer demands, and fire protection requirements

10 Analysis of Facilities  Pipelines  Storage tanks  Booster stations  Emergency power Under peak demand conditions, a number of minimum standards should be met for each of these facilities.

11 Pipelines  Distribution system mains are considered adequate if they can meet customer demands at a minimum system pressure of 20 psi.  Fire protection requirements should be met while maintaining a minimum pressure of 20 psi in the distribution system.  Note: State and local guidelines may require that higher pressures be maintained.

12 Distribution Storage  Storage facilities are considered adequate if the effective volume of the facility, or groups of facilities acting together, provide sufficient volume to meet equalization needs and a fire protection reserve (if necessary) during maximum day demand events.  State regulations are also considered as they relate to a particular distribution system.

13

14 Calculating Fire Flow Rates: ISO Guide For Determination of Needed Fire Flow Chapter 6 – Determining Recognition of Automatic Sprinkler Systems. ISO uses Specific Commercial Property Evaluation Schedule (SCOPES) to determine credit reduction of NFF for automatic sprinkler system protection. Must be installed and maintained in accordance to NFPA. Potential NFF credit reduction is not given until an ISO field inspection is conducted.

15 Calculating Fire Flow Rates What NFF should be requested on an application for service to New Jersey American Water?  ISO Non-Sprinklered  NFPA Sprinklered  Somewhere in between

16

17

18 AWWA Manual of Water Supply Practices M31: Preface  Addresses the planning, design, and maintenance of distribution systems that supply water for fire protection and suppression.  The emphasis is on public water systems and not on water systems exclusively designed for fire protection.  The adequacy of a water distribution system for fire protection depends on the fire flows required.

19 AWWA Manual of Water Supply Practices M31  Water Supply Requirements for Sprinklered Properties (p. 40)  A fire can occasionally overcome the capacity of a sprinkler system.  Required fire flow for sprinklered properties consists of the flow required for sprinklers, including a hose- stream allowance or 500 gpm, whichever is greater.

20 Calculating Fire Flow Rates  Based on the initial capital cost and operational expense incurred by building owners for installing an AFSS, American Water believes that some credit could be provided at the time of a service request. The NFF Calculation Worksheet was developed to ascertain NFFs at both ends of the spectrum.  It also is used to provide the local fire official an opportunity to acknowledge the building plans and provide experienced input for additional allowances for “outside” hose streams and adjacent structure exposure.

21 Calculating Fire Flow Rates  NFF Calculation Worksheet  Developed by New Jersey American Water as a screening tool  Although the higher NFF value is based on ISO’s “non- sprinklered” formulas, the worksheet is not endorsed or sanctioned by the ISO  The NFPA 13 Automatic Sprinkler System value is not checked or approved by the water company or the local Fire Official  Should be used as a guide in determining the “water system” NFF

22 Calculating Fire Flow Rates: Commercial and Multi-Family Buildings  New Jersey American Water is not responsible for operating and maintaining an AFSS. With an agreement from a building or property owner to be diligent in the AFSS maintenance, the company will consider recognizing an AFSS reduction for commercial or multi-family buildings or structures to a minimum of 1,000 gpm, should the NFPA 13 automatic sprinkler system flow, and requested fire official hose stream allowances be equal to or lower than 1,000 gpm.

23 Calculating Fire Flow Rates: Residential One- and Small Two-Family Dwellings  If a new one- and small two-family dwelling is proposed with individual AFSSs, New Jersey American Water will recognize a NFF credit. In lieu of using ISO’s “non- sprinklered” NFF determinations (Table 7, Guide For Determination of NFF), the company will reduce the small residential dwelling NFF to a minimum of 500 gpm, provided the NFPA 13D automatic sprinkler system flow and requested fire official hose stream allowances are equal to or lower than 500 gpm.  If the proposed development does not include AFSS, ISO’s Table 7 NFF will then govern.

24 Thank You. Questions? Lets now review the NFF Calculation Worksheet. Emphasize Residential vs. Commercial/Industrial