ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1

Slides:



Advertisements
Similar presentations
Quick Start Guide for Flat Screen ~ March 2013 CASIO Dual Projection System XJ-SK600/SK650.
Advertisements

Tandberg MXP Training Version 1.1, By David Anstee, First Connections Ltd.
My Projector Doesnt Project!!! …and other problems…
Product Presentation. WHAT IS IT? Product Presentation.
How To Use The Podium Touch Panel. Volume Up Volume Down Volume Mute Microphone On/Off Power Off / Exit The touch panel can operate by touching anywhere.
Data Projector Setting Up/Connecting Laptop & Data Projector.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Agnes Varis Campus Center Auditorium Audio Visual Training.
IT workshop for Interschool Online Debate 2004 Date: 13 Dec 2003 Venue: St. Bonaventure College.
Remote set-up instructions Life is meant to be interactive!
Department of Environmental Conservation 1 DATAMAX PRINTER SETUP MODULE 1.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
ESI Phone System Training Adcom/Valentine Systems
- Product Overview – The LMD DEFLECTOMETER ® Series Inductive Loop Detector Why guess when you can know! © Copyright EDI 2013.
DAP-1520 FAQ’s Wireless AC750 Dual Band Range Extender.
MH 201, 203, 205 Classroom Technology University of Dayton Information Technology Classroom Support.
BACKEND MULTIMEDIA ROOM Home User Guide Computer Projector DVD/ VCR Remote Mouse Save tutorial on desktop to watch full screen. Click boxes to jump into.
Voic message indicator This will light up if you have a message in your voic box It will flash when you receive a call Line Buttons #22 is the.
Lecture Theatre User Guide – Using the AV Pod, Projector and Screens If the touch panel is blank, press firmly to wake up. Start up the Pod To turn on.
`SET-UP MANUAL SRM D248 PURPOSE:
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
The Handling Camera1 Trainer Training The Handling Camera.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
Bmd Crossvent 3.
TyreCheck TYRECHECK KIT & CONTENTS 2 KIT CONTENTS: TURN ON POWER HERE 3 Wireless Pressure Stick Flexi Gauge 2 Chucks & Calibration Block.
(Smart Loop System) Installation Guide. Rev B Shipping Box Contains Everything that is included in the box being shipped to a customer should contain.
Manual of AWA6228 II).Several Basic Setups Hangzhou Aihua Instruments Co., Ltd.
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
Version 4 Multimedia Podium User Guide Version 4 Multimedia Podium User Guide Revision Date: September 2014.
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
COBAE - Smart Classroom Technology Vic Catalasan For immediate in-class assistant please call X1500 or
DWR-113 FAQ’s 3G WiFi Router.
Basic Operation of the Scott Mini-SA Portable Gas Detector.
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
RCD 510 Specification&Installation (RCD ~ ) For your best convenience QDIS CO., LTD -. MODEL: QVL – RCD510-V0 -. P/N : AD
OSD MANUAL FOR 700TVL CAMERA. ■ LENS You can select AUTO or MANUAL mode, depending on the connected lens type. AUTO(TYPE, MODE, SPEED) : Select Auto Iris.
Removing and Replacing the Battery Cover 1. Ensure the phone is turned off. 2. Press the Battery cover locker; lift the battery cover up and away from.
COCOA Disassembly Manual CKT Technical Dept. 2013/04/01.
RPTCS Automatic Transfer Control System Low and Medium Voltage Power Transfer Control.
GCS 300 System Operation Application – Level 1.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Polycom 601/650 IP Phone Quick Reference Guide SURVIVABILITY MODE
Content  1 Component  2 repair instruction  3 How to define problem  4 How to repair  5 How to disassemble  6 PC part  7 Button and Ports.
Camera Parts. 1. Body - Made of high grade plastic or metal, this holds all the other parts together as well as provide protection to the delicate.
NetVu Console Product Training V2.0 US.
Using Equipment in the (GH1) Lecture Theatres Presenters Andre Daniels Bradley Knight Clint Braaf.
Confidentiel –Usage interne Presentation RayCAm CA 1884.
Service Section Technical Training December 2005.
The Complete Training/Knowledge Guide. Session 2: Phone Basics  Removing the Back Cover  Installing the Battery  Removing the Battery  Installing.
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
Saunders® I-VUE The Intelligent Valve Sensor – Interactive Guide Key Features and Benefits Programming the Saunders® I-VUE Alarm Code Definitions How to.
DIVISIONSPECIFICATION INPUT POWER DC 24V / 1.25A ※ Power supply from the floor distributor is not available. MAX POWER CONSUMPTION Max 30W VOICE CONVERSATION.
FEATURES USER’S MANUAL COLOR BOX CAMERA SDB-BAW SDB-BAW/T 1/3 " SONY 960H Dual Scan CCD High Resolution of 800TV Lines Min. Illumination of Lux at.
BASIC ELECTION TRAINING Presented by the DeSoto County Election Commission.
1Crypto AG / CN_M_HC-2650-Operation-e_0830_rd.PPT Training and Education HC-2650 Operation - Course Notes.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
FEATURES HD-SDI COLOR CCTV CAMERA USER’S MANUAL SDI-BS212 SDI-BS212T 1/3” Panasonic 2.1M Pixel Progressive Scan Color CMOS Sensor Video.
Quick Start Guide ST30/ST32 Series mobile computer.
How Kaspersky helps in recovering lost or stolen mobile device.
Camera Parts.
How to Set Up and Finish a Video Call on MXP880
Maintenance masterdrive siemens
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
HVI HIPOT TEST SET Pft sERIES.
Lamp Error reset Method to solve “Lamp Error” problem
Fix Bitdefender Antivirus Error 403 Give a Ring on: Bitdefender Support Number.
ABB Graphical display for UPS
Camera Parts.
Conference room user manual
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 1 You receive 2 boxes for each metal detector: Main Control & Display Unit Side Panels (Left&Right)

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan When you open the boxes: You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan When you open the boxes: Main Control & Display Unit Back Fixing Unit Left Side Panel Right Side Panel 2

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 3 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 3 Assembling Back Fixing Unit 4 Other side

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan Screw up the rear cover of the Main Control & Display Unit. 5

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 7 For the sockets: You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 7 For the sockets: ThruScan is designed to prevent false connector/socket connection. Left Panel – female D-Sub 25 Mains Socket - SRC- D-Sub 9 Right Panel – male D-Sub 25 6

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan Screw down the Main Control & Display Unit. Fix strongly to the side panels. 8 9

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 11 10 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 11 10 Lift up your ThruScan Fasten the black blind taps

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 12 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 12 Plug in the connectors.

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 13 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan Right Side Panel Connector Mains Connector (from left side panel) 13 Left Side Panel Connectors Impossible to make mistake… 14

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 15 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 15 Close the rear cover of Main Display & Control Unit.

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 16 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan Adjust the distance between side panels to 76 cms. 16

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 18 17 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 18 17 Mark the positions of side panel holders.

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 19 20 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 19 20 Drill & Fix the side panel holders to the ground – stable conditions. 21 22

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 23 You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr ASSEMBLING & MOUNTING ThruScan 23 Put your ThruScan into the side panel holders inside and screw the bolts. 25 24

ELEKTRAL A.S. CONTROL PANEL OF ThruScan Metal Detectors TOUCH PADS OFF BUTTON ON BUTTON BATTERY INDICATOR LCD DISPLAY 4*20 RUN BUTTON SEL UP DOWN ALARM LOCATOR LED VU DISPLAY TOUCH PADS PACING LIGHT INDICATOR

ELEKTRAL A.S. MULTI POINT INDICATOR LIGHTS ENTRANCE- Traffic Lights Led illuminated Warning Displays on Zones

ELEKTRAL A.S. RELAY CONTACT OUTPUTS RELAY CONTACT OUTPUTS Provides to control CCTV Cameras, Turnstiles, Gates…etc. SYNC & REMOTE CONTROL OUTPUTS For tandem operation or SRC- Scada Remote Control

ELEKTRAL A.S. PROGRAMMING & SETUP Normal Operating Screen IN OUT (When you swich on – the screen) IN OUT 01978 00027 SECURITY LEVEL 03 To enter the program menu Press ENTER PASSWORD [0---] If the correct password is entered display will change to: SECURITY LEVEL LEVEL 02 If the password is incorrect: SECURITY LEVEL PASSWORD ERROR

ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS ThruScan s9 has 10 seperate SECURITY LEVELS ThruScan sX has 20 seperate SECURITY LEVELS SECURITY LEVEL LEVEL 02 It is possible to adjust a total of 246 sensitivity levels from security level 000 (highest sensitivity) to 245 (lowest sensitivity) ThruScan s9 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL SENSITIVITY ADJUSTMENT Security Level (NC) NILECJ – Level 2 (factory fixed) Security Level 1 010 Security Level 2 020 Security Level 3 030 Security Level 4 050 Security Level 5 100 Security Level 6 140 Security Level 7 180 Security Level 8 220 Security Level 9 230

ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS ThruScan sX SECURITY LEVEL SENSITIVITY ADJUSTMENT Security Level (NC) NILECJ – Level 2 (factory fixed) Security Level 1 010 Security Level 2 020 Security Level 3 030 Security Level 4 040 Security Level 5 050 Security Level 6 060 Security Level 7 070 Security Level 8 080 Security Level 9 090 Security Level 10 100 Security Level 11 110 Security Level 12 Security Level 13 Security Level 14 Security Level 15 Security Level 16 Security Level 17 Security Level 18 Security Level AD 120 140 160 180 200 220 240 030 – Auto Designation/AD SECURITY LEVEL LEVEL 02 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL LEVEL [15]=180

ELEKTRAL A.S. You can make fine tunning here: 185 IN OUT Between 000(highest sebsitivity) – 245(lowest sensitivity) SECURITY LEVEL LEVEL [15]=180 IN OUT 01978 00027 SECURITY LEVEL 03 ENTER PASSWORD [0---] SECURITY LEVEL LEVEL [02] SECURITY LEVEL LEVEL 02 SECURITY LEVEL LEVEL [15]

ELEKTRAL A.S. Normal Operating Mode Other Menus SECURITY LEVEL

ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL, ZONE ADJUSTMENTS for ThruScan sX The sensitivity levels of zones can be adjusted separately. The sensitivity level of zone 2 in which there would more likely be keys, cell phones, belts etc. can be decreased while the other zones’ can be increased. * 5 IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL [02] SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL 02 * 1 Other Menus ZONE=2 ZONE=3 INDIVIDUAL ZONE SENS SECURITY LEVEL LEVEL [02] ZONE=[01] Normal Operating Mode ZONE [01]=20

ELEKTRAL A.S. AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN for ThruScan sX This menu is to help the user to decide and to assign the required sensitivity level very rapidly. * 5 * 2 AUTO DESIGNATE MODE IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL 3/2 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL 3/1 USED FOR AUTO DESIGNATE OF SECURITY LEVEL TO CONTINUE PRESS SEL 01 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL 3/3 DESIGNATE-DETECTMOD ALL ZONES 00 ZONE 01 [00] 00

ELEKTRAL A.S. AUTO DESIGNATION MODE - continue 01 IN OUT AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL ZONE [01] DESIGNATE-DETECTMOD ALL ZONES 00 ZONE 01 [53] SELECT THE ZONE AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL ZONE [01]=53 AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL LEVEL [AD]=53 AUTO DESIGNATE MODE IN OUT 01978 00027 SECURITY LEVEL 03

ELEKTRAL A.S. ALARM VOLUME ADJUSTMENT * 5 * 3 IN OUT ThruScan s9-sX has 10 separate alarm volume levels, 1 quietest – 10 loudest – 00 Mute If you want different tones, pls mention with your order. It has 10 different tones in the menu. * 5 * 3 ALARM VOLUME 0<=>10 IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 ALARM VOLUME 0<=>10 VOLUME=10 ALARM VOLUME 0<=>10 VOLUME=05

ELEKTRAL A.S. ALARM COUNTER * 5 * 4 IN OUT MENU SECURITY LEVEL 00012 IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE ALARM COUNTER 00012 RESET Y <=> N N MENU ALARM COUNTER 00000 ALARM COUNTER 00012 RESET Y <=> N Y

ELEKTRAL A.S. IN – OUT COUNTER (TRAFFIC COUNT) * 5 * 5 IN OUT MENU 99999………………….…01977 IN>-COUNTER-<OUT IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE 99999………………….…01977 IN>-COUNTER-<OUT ACTIVE =00 00 – Do not reset 01 – Reset In Count 02 – Reset Out Count 03 – Reset Both Counters MENU

ELEKTRAL A.S. FACTORY SETTINGS * 5 * 6 IN OUT MENU ThruScan s9-sX can be returned to factory setting by this menu. * 5 * 6 FACTORY SETTINGS Y<==>N IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE FACTORY SETTINGS Y<==>N ACTIVE =N Y – FACTORY RESET N – DO NOT RESET MENU

<===================> ELEKTRAL A.S. LANGUAGE SELECTION ThruScan s9-sX can be operated in 4 languages- EN-DE-SPA-TR * 5 * 7 LANGUAGE ENGLISH IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE LANGUAGE ENGLISH <===================> ENGLISH DEUTSCH TURKCE ESPANOL MENU

ELEKTRAL A.S. COUNTER VISIBILITY * 5 * 8 IN OUT IN OUT MENU ThruScan s9-sx’ Normal Operating Mode-Menu Displaycan be inhibited. * 5 * 8 COUNTER VISIBILITY Y<==>N IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE COUNTER VISIBILITY Y<==>N ACTIVE =Y N – DISPLAY OFF Y – DISPLAY ON MENU IN OUT ***** ***** SECURITY LEVEL 03

ELEKTRAL A.S. ENVIRONMENT NOISE LEVEL * 5 * 9 IN OUT MENU This menu is prepared to measure the electromagnetic noise level in the environment in which the ThruScan was placed and help the user with the sensitivity level assignment. * 5 * 9 ENVIRONMENTAL NOISE LEVEL IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE ENVIRONMENTAL NOISE LEVEL NOISE = 003 MENU

ELEKTRAL A.S. NEW PASSWORD * 5 * 10 IN OUT MENU You can change your 4 digit pin-code as follows: Let’s make password 1978 * 5 * 10 NEW PASSWORD [ ] IN OUT 01978 00027 SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NEW PASSWORD [ 1 9 7 8 ] NEW PASSWORD [ 1 * * * ] NEW PASSWORD [ 0 * * * ] 1 2 3………. 8 9 1 2 3………. 8 9 NORMAL OPERATING MODE MENU